BUSINESS GROUP B <br />1,776 GSF <br />RESIDENTIAL <br />LOW -HAZARD STORAGE GROUP S-2 <br />2,619 GSF (EXISTING) <br />BUILDING CODE ANALYSIS: RENOVATION OF EXISTING FIRE STATION <br />JURISDICTIONAL CODES: <br />Florida Building Code (FBC) 2010 - Existing Building <br />Florida Building Code 2010 - Building <br />Florida Building Code 2010 - Accessibility <br />2010 Florida Fire Prevention Code (includes NFPA I - Uniform Fire Code and <br />NFPA 101 - Life Safety Code, 2010 Editions) <br />ALTERATIONS - LEVEL 2 <br />404.1 Scope. Level 2 Alterations include the r000nfiguration of space, the addition or elimination ofany door or window, the <br />reconfiguarion or extension of any system, or the Installation of any additional equipment <br />701.3 Complisance. All now construction elements, components, systems, and spaces shall comply with the requirements of the <br />Florida Building Code, Building. <br />703.1 Scope. The requirements of this section are limited to work areas In which Level 2 alterations are being perliormed, and <br />shall apply beyond the work area wherespecifled. <br />PROJECT SCOPE OF WORK: Reconfigure 1,529 GSF (20%) of building area into office space, replace exterior doors and <br />windows with Impact -resistant doom and windows, and re -roof flat roof areas. <br />EXISTING FIRE STATION: <br />The original building was constructed In 1960. There was a first addition. The second addition was completed In 1983. <br />Mixed Occupancy: Business Group B <br />Residential Group R-2 <br />Low -Hazard Storage Group S-2 <br />CONSTRUCTION TYPES (FBC Construction Classification -Table 601, pg 6.1): <br />Conversion to current <br />FBC, 2010 Edition: TYPE II-B, Unprotected, Sprinklered <br />Structural Frame: 0 <br />Exterior Bearing Walls 0 <br />Interior Bearing Walls 0 <br />Nonbearing Walls and Partitions 0 <br />Floor Construction 0 <br />Roof Construction 0 <br />Sprinkler System: Fully sprInklered <br />Fire Alarm: Existing <br />Existing Bldg. Area: 7,671 GSF <br />Existing Bldg. Height +/- I W-0" (Building), +/- 37-00 (Tower) <br />FBC 603.1 (4): Roof coverings shall have an A, B or C classification. <br />Check Allowable Area for Existing Fire Station: Type II-B, Sprinklered (Table 503, pg 5.2) <br />Group B <br />3 Stories Allowable: Complies <br />551 High Building Allowable: Compiles <br />23,000 SF Allowable Area (w/o sprinkler system): Compiles <br />Check Allowable Area with Automatic Sprinkler System Increase (FBC; 506.3, pg 5.4) = 300% for buildings with no more than one <br />story above grade plans. <br />Allowable Area (sprinkler system) = 23,000 GSF x 300% m 69,000 GSF <br />Actual Area = 7,671 GSF (Compiles) <br />Arrangement and Number of Exits: <br />705.4.1.1 Occupant load and travel distance: In any work area, all rooms and spaces having an occupant load greater than 50 or <br />In which the travel distance to an exit exceed 75 feet shall have a minimum of two egress doorways. <br />Required Number of Exits for Occupant Load (Persons per Story) per FBC 1019. 1: <br />1-50 Persons: 1 ExIt <br />50-500 Persons: 2 Exits <br />501 - 1,000 Persons: 3 Exits <br />More than 1,000 Persons: 4 Exits <br />Exit Access Travel Distance <br />Work Area: 300'fbr Business, Sprinklered per FBC Table 1016.1 <br />Common Path of Travel: 100, <br />(NFPA, Table A7.6 & 7.12.1) <br />FIRE SEPARATIONS <br />FBC SECTION 508 MIXED USE AND OCCUPANCY <br />Business Group B <br />508.4 Separated occupancies. Buildings or portions of buildings that comply with the provisions of this section shall be <br />considered as separated occupancies. <br />Business Group B <br />Residential Group R-2 <br />Low -Hazard Storage, Group S-2 (Apparatus Bays) <br />FBC Table 508.4 - REQUIRED SEPARATION OF OCCUPANCIES thours <br />Residential Group R-2 / Business Group B: 1 hour fire separation required. <br />Low -Hazard Storage Group S-2 / Business Group B: I hour fire separation required. <br />Residential Group R-2 / Low -Hazard Storage Group S-2: 1 hour fire separation required. <br />FBC Table 508 . 2.5 - INCIDENTAL ACCESSORY OCCUPANCIES <br />Provide a one -hour fire separation or an automatic fire-extingulshing system for storage rooms over 100 SF, furnace rooms <br />(where any piece of equipment Is over 400,000 BTU per hour Input), rooms with boilers (where the largest piece of equipment Is <br />over 15 psi and 10 horsepower) and refrigerant machinery rooms. <br />Calculate FBC Occupant Load of the Building <br />Minimum Occupant Load - Table 1004.1.1 <br />Per FBC Section 1002: Gross Floor Area = Floor area within the Inside perimeter of the exterior wells of the building, <br />exclusive of vent shaft and courts, without deduction for corridors, stairways, closets, to thickness of interior wells, <br />columns or other features. The floor area of a building, or portion thereof, not provided with surrounding exterior walls <br />shall be the usable area under the horizontal projection of the roof or floor above. The gross floor area shall not <br />include shaft with no openings or Interior courts. Not Floor Area = the actual occupied area not Including unocupled <br />accessory areas such as corridors, stairways, toilet rooms, mechanical rooms and closets. <br />W.W=01001do <br />plens <br />Review <br />122 SIF <br />Tower <br />69 SF <br />I L — — — — — — L <br />F- — — — — — — — — — — — — — — — — — <br />I <br />office <br />96 SF <br />103 :1 <br />169sp- <br />Reception <br />Ej-007] FE <br />229 SF <br />1117�0' <br />Bath 3,276 GSF (EXISTING) <br />LIL2A h <br />— — — — — 50 S—F —1 — — — — — — — — — — — — — — — <br />Future officees <br />office office Bunk <br />112 <br />Lobby <br />91 SF 93SF 106 SF <br />�j [ 110 <br />3:F� 1 97 SF <br />74 FT TRAVEL DISTANCE <br />i4mor <br />C <br />EMME 0M ME . . ME <br />mEN'mSR `70 <br />ME ME ME ME E <br />(F; rO MmM M) <br />FEC <br />ES <br />1,01me <br />Conference <br />Z <br />0 <br />21 <br />\\,44 <br />300 SF <br />21 <br />0 <br />SF� <br />0 <br />tZ <br />01 <br />ce) <br />looticlor' <br />F <br />F_ <br />E3 <br />_j <br />,SF <br />*Jftn <br />- 49 SF" <br />L <br />Reports <br />0111108 <br />108 SF <br />115 <br />32 SF Room <br />lie <br />110SF <br />corrid" <br />71 <br />117 <br />FireMarshal's <br />75 SF <br />011fice <br />253 SF <br />0 <br />OFE Corrklor <br />JL ME ME ME <br />#*(-_— <br />Kitchen Ell M <br />F-12-17 ......... / ........... <br />256 SF Decontarril <br />85 SIF <br />Dayroorn <br />417 8F <br />108 SIF <br />_�o <br />If a07 <br />E)08T. TO <br />REMAIN <br />,/0 0 <br />r1K <br />154 FT Bunk <br />Room <br />Broakroorn (FROM MEN'S ROOM) F 122 <br />313 SF <br />610 SF <br />SOLAR PUMP STATION <br />�POLAR WATER HEATER <br />1 HR <br />L <br />1 HR <br />IE <br />I <br />Equipment ..... .... Generator <br />Storep Wall Room <br />IL 164 SF 268 SF 189 SF <br />LIFE SAFETY FLOOR PLAN <br />/A VI/I <br />��i 1/8' = V-0, <br />storage <br />L 125 <br />L <br />21 SF <br />FBC TABLE 1004.1.1 - MAX. FLOOR AREA ALLOWANCES PER OCCUPANT <br />Business <br />1 Person/ 100 GSF <br />Assembly (UnconoenftW) <br />1 Person/ 15 NSF <br />Dormitories <br />1 Person/ 50 GSF <br />Parking Garages <br />I Person / 200 GSF <br />Storage <br />1 Person / 300 GSF <br />Calculate FBC Occupant Load of the Building: <br />Room No. & Room Name <br />Area <br />Factor <br />Occupants <br />(for <br />Exiting & Fixture Count) <br />Now Construction: <br />Reception <br />229 NSF <br />1 Person/ 100 GSF <br />2 <br />Tower <br />64 NSF <br />I Person/ 100 GSF <br />1 <br />Plans Review <br />122 NSF <br />I Person / 100 GSF <br />2 <br />Office <br />96 NSF <br />I Person / 100 GSF <br />I <br />Office <br />91 NSF <br />I Person/ 100 GSF <br />I <br />Future Office <br />93 NSF <br />I Person/ 100 GSF <br />I <br />Women <br />47 NSF <br />1 Person /100 GSF <br />1 <br />Men <br />53 NSF <br />1 Person/ 100 GSF <br />1 <br />Conference Room 300 NSF I Person/ 15 NSF 20 <br />30 Persons <br />Existina Construction: <br />Lobby <br />97 NSF <br />1 Person/ 100 GSF <br />1 <br />Reports Office <br />108 NSF <br />I Person/ 100 GSF <br />I <br />Fire Marshal's Office <br />253 NSF <br />1 Person/ 100 GSF <br />1 <br />Gear Room <br />110 NSF <br />I Person /100 GSF <br />1 <br />Decontamination <br />85 NSF <br />1 Person/ 100 GSF <br />1 <br />Restroom <br />106 NSF <br />1 Person/ 100 GSF <br />I <br />Dayroom <br />417 NSF <br />I Person/ 100 GSF <br />4 <br />Kitchen <br />286 NSF <br />1 Person/ 100 GSF <br />3 <br />Breakroom <br />615 NSF <br />1 Person/ 100 GSF <br />6 <br />Bunk Room <br />313 NSF <br />I Person/ 50 GSF <br />6 <br />Officer's Bunk <br />106 NSF <br />I Person/ 50 GSF <br />2 <br />Bath <br />50 NSF <br />I Person/ 50 GSF <br />I <br />Apparatus Bay <br />480 NSF <br />1 Person / 200 GSF <br />2 <br />Apparatus Bay <br />476 NSF <br />1 Person / 200 GSF <br />2 <br />Apparatus Bay <br />478 NSF <br />I Person / 200 GSF <br />2 <br />Apparatus Bay <br />478 NSF <br />1 Person / 200 GSF <br />2 <br />Equipment Storage <br />164 NSF <br />1 Person / 300 GSF <br />1 <br />Well <br />272 NSF <br />I Person 1300 GSF <br />I <br />Generator Room <br />192 NSF <br />1 Person / 300 GSF <br />1 <br />Storaos <br />75 NSF <br />I Person / 300 GSF <br />I <br />43 Persons <br />TOTAL OCCUPANCY 73Persons <br />Required Egress width for Doors: <br />Factor 020 per occupant for Door Opening a (FBC Table 1005, Pg 10.5) <br />73 Persons (Xfilerson) - 14.6- Door WIM <br />Exist Capacity: Sr Wide Door Opening + .2"/Person 170 Persons <br />W Wide Door Opening + 2"lPerson 340 Poisons <br />Portable Fire Extinguishers: <br />Re* to NFPA 10 - Standard for ftrtohlb Rm Wnyukhers, 2010 EdWon lbr portable fire extingul" requiremerits. <br />Class A Hazards (Typical): <br />Maxlrnurn Travel Distance to Ex*VuWw - 717 <br />Apparatus Apparatus <br />Bay Bay <br />128 129 <br />480 SF 478 SF <br />170 <br />131 FT <br />ME M5 ME M0 ME ME ME SEE ME ME <br />(FROM MEN'S ROOM) <br />Apparatus ApparAn <br />Bay B" <br />130 131 <br />478 SF 478 SF <br />4 <br />4 <br />4 <br />Plumbing Fixture Calculations: <br />Plumbing fixtures shall be provided .... as per FBC-P Table 403.1. The number of Occupants <br />shall be determined by the Florida Building Code - Building. <br />The occupant load content shall be composed of 50 percent of each sex (FBC-P 403.1.1 Pg 4.4) <br />FBC-P 403.1.1 Fixture Calculations - Exception: the total occupant load shall not be required to be divided In half where <br />approved statistical data indicates a distribution of ft sexes of other than 50 percent of each sex. <br />73 PERSONS: 70% MALES + 30% FEMALES = 51 MALES + 22 FEMALES <br />PLUMBING FIXTURE REQUIREMENTS <br />WATER CLOSETS <br />LAVATORIES <br />DRINKING <br />FOUNTAIN <br />MALE <br />I FEMALE <br />MALE __]_ <br />FEMALE <br />I PER 25 FOR THE FIRST 50 AND I PER 50 <br />FOR THE REMAINDER EXCEEDING 50 <br />1 PER 40 FOR THE FIRST 80 AND I PER 80 <br />FOR THE REMAINDER EXCEEDING 80 <br />1 PER 100 <br />2 REQUIRED <br />I REQUIRED <br />I REQUIRED <br />I REQUIRED <br />I REQUIRED <br />3 EXISTING <br />3 EXISTING <br />I EXISTING <br />NEW CONSTRUCTION: <br />3 PROVIDED <br />1 PROVIDED <br />3 PROVIDED <br />I PROVIDED <br />2 PROVIDED <br />FBC PLUMBING <br />SECTION 419 URINALS: URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 50 <br />PERCENT OF THE REQUIRED WATER CLOSETS IN BUSINESS OCCUPANCIES. <br />URINALS PROVIDED: 0 REQUIRED / 0 PROVIDED <br />SERVICE SINKS: 0 REQUIRED / I PROVIDED <br />M-0 <br />ILIFE &AFEW LEGEND (SEE ELECTRICAL SYMBOL LEGENID) <br />PRIMARY EXrr <br />IM1116INCY UWff FDCrURE <br />Eu <br />ampummusiffrKME <br />SECONDARY E)ff <br />EMERGENCY FLUORESCENT FDCrURE <br />MOT S*N <br />E)ffCAPACrrY <br />MA�OFPWWONM <br />FIRE ALARM MANUAL PULL STATION <br />FE <br />FIRM EXT94OUNHOM <br />14AM ALARM HORNN%ASHINQ 8 IRONS LXW <br />WAXETWITID. <br />FEC <br />FRE EXTV49UNIM CANDMIT <br />AND FIRE EXTHRODMIL <br />FIRE ALARM HORN <br />FIRE RATED PARTMONS <br />FIRE ALARM Wini RAMON 87MM LOU <br />AS PER PLANS <br />EXISTING CONSTRUCTION <br />FACP <br />FIRE EXTINGUISHERS <br />PROVIDE MULTI -PURPOSE, DRY CHEMICAL TYPE FIRE EXTINGUISHERS FOR <br />CLASS A. B AND C FIRES. MINIMUM RATING IS 2A 10 BC. <br />LEANDRO A. ARROYO <br />FL. REG. NO. 12326 <br />CITY OF ZEPHYRHILLS <br />RENOVATION <br />OF <br />FIRE RESCUE <br />STATION NO. 2 <br />CONSTRUCTION <br />DOCUMENTS <br />12-07-2012 N <br />CB+A #1202 <br />CANERDAY <br />BELFSKY <br />ARROYO <br />ARCHITECTS <br />800 SECOND AVENUE SOUTH <br />ST. PETERSBURG, Fl. 33701 <br />(727)823-0675 <br />AA2WM7 <br />0 N <br />LIFE SAFETY FLOOR PLAN Al A <br />SCALE: 1/8"= V-0" m 0 <br />