My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38410 6th Ave (2)
Zephyrhills
>
Building Department
>
Building Plans
>
38410 6th Ave (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 7:27:44 PM
Creation date
2/18/2025 4:19:27 PM
Metadata
Fields
Template:
Building Plans
Street #
38410
Location
6th Ave
Contractor
Pillar Construction Group
Building Plans - Permit #
14813
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AIR HANDLING UNIT <br />REFER TO CHART BELOW FOR SIZES <br />CLEAN —OUT PLUG <br />CLEAN —OUT PLUG <br />CLEAN —OUT PLUG <br />UNION I, PIPE TO DRAIN <br />H (1" FOR EACH 1" OF MAXIMUM NEGATIVE STATIC PRESSURE) + 1- <br />J HALF OF H <br />L H + J + PIPE DIAMETER + INSULATION <br />THIS DETAIL IS FOR DIAGRAMMATIC PURPOSES ONLY. REFER TO MANUFACTURER'S <br />SPECIFICATIONS FOR PROPER TRAPPING AND INSULATION. <br />CONDENSATE PIPE SIZE <br />COOLING COIL MBH/TON <br />0 (INCH) <br />UP TO 24/2 <br />V4 <br />UP TO 60/5 <br />1 <br />UP TO 360/30 <br />1% <br />/r'A <br />UP TO 600/50 <br />lh <br />NOTE-7 <br />NOTE <br />0 REFER TO AIR HANDLER SCHEDULE FOR COOLING COIL MBH/TON. <br />TYPICAL CONDENSATE DRAIN/TRAP DETAIL <br />NO SCALE <br />FASTEN SUPPORT STEEL TO <br />EXISTING STRUCTURE <br />ALL THREAD ROD---\ <br />PLACEMENT SHALL NOT <br />PROHIBIT ANY SERVICING <br />AND/OR MAINTAINING OF <br />AIR HANDLER <br />RA <br />===—ALL THREAD ROD <br />W/VIBRATION <br />ISOLATOR (TYPICAL) <br />r FLEXIBLE <br />AIR HANDLER CANVAS <br />(TYP-) <br />CD <br />SA <br />r-F /---CONEDENSATE <br />I PUMP <br />RUN ALL THREAD ROD ---J REFRIGERANT PIPING---J " TRAPPED <br />THROUGH UNISTRUT TO CONDENSING UNIT CONDENSATE DRAIN <br />UNDERNEATH UNIT AND OUTSIDE <br />FASTEN SECURELY WITH <br />NUT AND WASHER. <br />(TIT? - ) <br />KEYED NOTES <br />(DAUXILIARY DRAIN PAN, NTH FLOAT SWITCH. PAN TO EXTEND 13EYOND AIR HANDLER, <br />VALVE PACKAGE, AND CONDENSATE PUMP. <br />QREFER TO FLOOR PLANS FOR CONTINUATION OF CONDENSATE PIPE ROUTING. <br />AIR HANDLER DETAIL <br />NO SCALE TYP. OF AH-3 <br />BUCKLEY MODEL 3300D <br />45* BRANCH CONNECTION <br />NO SCALE (TYPICAL) <br />VOLUME DAMPER NTH EXTENDED STEM IS REQUIRED <br />WHEN DUCT IS EXTERNALLY WRAPPED. PROVIDE NTH <br />STAMPED, INDICATING LOCKING QUADRANT HANDLE. <br />45' BRANCH CONNECTION <br />NO SCALE (TYPICAET <br />0 L = 1/4- W OR 4-MINIMUM <br />(D TO BRANCH DUCT <br />4g) CAULK AIR —JOINT AIR—TiGHT <br />IPER NTH EXTENDED STEM IS REQUIRED <br />WHEN DUCT SERVING SIDEWALL AIR DEVICE. PROVIDE <br />NTH STAMPED, INDICATING LOCKING QUADRANT <br />HANDLE. <br />SUPPLY DUCT (SEE DUCT SEALER AT SPIN —IN COLLAR CONNECTION TO MAIN <br />PLANS FOR SIZES) VOLUME DAMPER W/LOCKING QUADRANT AND 2- STANDOFF <br />MAX. SAG 1/2- PER FOOT BETWEEN SUPPORT POINTS <br />ADJ. S.S. CLAMP <br />UPPER ATTACHMENT PER SMACNA <br />FLEXIBLE DU CT 6'-0" MIN. TO 10'-0" <br />LLA .. LL uU <br />MAX. LENGTH MAX. D/8 OFFSET <br />ALLOWED IN'LAST D INCHES TO DEVICE <br />WHERE D IS THE INTERNAL FLEX <br />D I M T <br />IAMETER <br />NECK SIZE TO MATCH FLEX <br />DUCT SIZE INDICATED <br />DUCT SEALER <br />NYLON CABLE TIE <br />INSULATE TOP PANEL <br />OF LAY —IN DIFFUSER <br />CEILING FLEXRIGHT FLEXIBLE <br />DUCT ELBOW OR AIR DISTRIBUTION DEVICE, SEE <br />EQUIVALENT SCHEDULE. LAY —IN SHOWN, <br />SURFACE MOUNT SIMILAR <br />CEILING T—BAR SHOWN HARD CLG. SIMILAR <br />FLEXIBLE DUCT NOTES <br />1. FLEXIBLE DUCTS SHALL BE ONE—PIECE AND SHALL NOT BE SPUCED TOGETHER. <br />2. EXTEND FLEXIBLE DUCT INSULATION TO DUCT/DIFFUSER PANEL INSULATION AND SEAL <br />NTH MASTIC. <br />3. MIN. 1" WIDE 22 GALV. STRAP HANGER NTH HEMMED EDGES PER SMACNA FIGURE 3-10. <br />4. FLEXIBLE AIR DUCT SHALL BE FULLY EXTENDED AND NOT COMPRESSED WITH ELBOW <br />RADIUS NO LESS THAN R/D — 1.0 <br />TYPICAL SUPPLY FLEXIBLE DUCT DETAIL <br />NO SCALE flename: MD91 <br />disk no.: #02 <br />RETURN DUCT (SEE DUCT SEALER AT SPIN —IN COLLAR CONNECTION TO MAIN <br />PLANS FOR SIZES) VOLUME DAMPER W&OCKING QUADRANT AND 2m STANDOFF <br />MAX. SAG 1/2- PER FOOT BETWEEN SUPPORT POINTS <br />- --------- ........ EXTERIOR WALL <br />UPPER ATTACHMENT PER SMACNA <br />INSULATE L CAULK JOINTS AIR TIGHT <br />REFRIGERANT PIPING FLEXIBLE DUCT 6'-0" MINIMUM <br />INSIDE FACE OF WALL—\ PER SPECIFICATIONS. TO 10'—Om MAXIMUM LENGTH <br />NUMBER AND SIZE ADJ S S MAX i D/8 OFFSET ALLOWED IN <br />PER MANUFACTURER SLEEVE <br />WATER RESISTANT FIRE RECOMMENDATION. ECCENTRIC TRANSITION CLAM P' LAST D INCHES TO DEVICE <br />—PROVIDE NTH ALUMINUM NO SCALE (TYPICAL) WHERE D IS THE INTERNAL <br />CAULK (TYPICAL) m JACKET PER 15260 FLEX DIAMETER. <br />7,77 77 777'�Z'�z zz;z'�zj A NECK SIZE TO MATCH FLEX <br />REFRIGERANT PIPING DUCT SIZE INDICATED <br />UP ALONG WALL TO DUCT SEALER <br />UNIT. 40 CONCRETE PAD CEILING T—BAR SHOWN <br />HARD CLG. SIMILAR NYLON CABLE TIE <br />FLEXRIGHT FLEXIBLE <br />FINISHED FLOOR TYPICAL CONICAL TAP FOR BRANCH DUCTS, REQUIRES DUCT ELBOW OR SQUARE TO ROUND <br />FINISHED ACCURATE HOLE CUT EQUIVALENT TRANSITION <br />GRADE 311 <br />/lz TYPICAL BELLMOUTH TAP FOR BRANCH DUCTS, <br />INSULATED PIPE <br />*3 <br />PIPE REQUIRES ACCURATE HOLE CUT Mil ING ZAIR DISTRIBU71ON DEVICE, SEE SCHEDULE. <br />3 ST LAY —IN SHOWN, SURFACE MOUNT SIMILAR <br />SCHEDULE 40 STEEL FLEXIBLE DUCT NOTES <br />PIPE SLEEVE OUTSIDE WALL VOLUME DAMPER NTH EXTENDED STEM IS REQUIRED 1. FLEXIBLE DUCTS SHALL BE ONE—PIECE AND SHALL NOT BE SPLICED TOGETHER. <br />WHEN DUCT IS EXTERNALLY WRAPPED. PROVIDE WITH <br />EXTEND FLEXIBLE DUCT INSULATION TO DUCT/DIFFUSER PANEL INSULATION AND SEAL <br />MINERAL WOOL PACKING STAMPED, INDICATING LOCKING QUADRANT. 2. NTH MASTIC. <br />3. MIN. 1" WIDE 22 GALV. STRAP HANGER NTH HEMMED EDGES PER SMACNA FIGURE 3-10. <br />ALTERNATE FITTINGS TO BE USED WHEN DUCT HEIGHT 4. FLEXIBLE AIR DUCT SHALL BE FULLY EXTENDED AND NOT COMPRESSED WITH ELBOW <br />DOES NOT PERMIT THE USE OF THE FULL SIZE RADIUS NO LESS THAN R/D = 1.0 <br />—BELLMOUTH <br />BELLMOUTH/CONICAL TAP INCLUDE: MINI 5. HANGERS, SADDLES AND OTHER SUPPORTS SHALL MEET THE DUCT MANUFAUFACTURE'S <br />NOTE: (M—BMD), OVAL—BELLMOUTH (FOBMD) AND STD 45- RECOMMENDATIONS AND SHALL BE OF SUFFICIENT WIDTH TO PREVENT RESTRICTION OF <br />CONTRACTOR SHALL SUBMIT U.L. APPROVED PENETRATION DETAIL FOR PENETRATIONS IN RECTANGULAR TO ROUND (3300D) THE INTERNAL DUCT DIAMETER. IN NO CASE SHALL THE MATERIAL SUPPORTING <br />RATED WALLS AND FLOORS. FLEXIBLE DUCT <br />THAT IN DIRECT CONTACT NTH IT BE LESS THAN 11 INCHES (38mm) WIDE. <br />TYPICAL WALL S VE DETAIL TYPICAL REFRIGERANT PIPING DETAL TYPICAL BRANCH TAKE -OFF DETAILS RETURN FLEXIBLE DUCT DETAIL <br />NO SCALE filen.m.; MM NO SCALE filename: MD124 NO SCALE NO SCALE <br />disk no.: #02 <br />ANGLED VALVE SOLENOID EXPANSION BUILDING <br />LIQUID SITE GLASS VALVE LIQUID DIST. <br />(TYP'.) .. ... ... ...... ... <br />DRYER SHUTOFF 18 G.A. 1-1/4 WIDE SLEEVE AND SEAL-\ <br />ANGLED, PRE —DRILLED, WATER TIGHT CLEANOUT — DURA—COATED CAST IRON FERRULE WITH <br />S.S. HURRICANE STRAP. THREADED BRONZE COUNTER SUNK CLEANOUT PLUG. <br />PRESSURE TAP 2 PER SIDE. TYPICAL rl REFER TO PLANS FOR SIZES. <br />CONDENSING UNIT S.S. REFRIGERANT ZURN Z-1 440—BP <br />JOSAM 58500-22 <br />J.R. SMITH 4031—PB 12" x 12* x 4" THICK FIBER <br />SUCTION C 7 NUT, BOLT AND LOCK WASHER NEOPRENE ISOLATION MATCH EXISTING REINFORCED CONCRETE PAD <br />COOUNG COIL 46" GALVANIZED STEEL DOUBLE DEFLECTION COVER PAINTED T <br />NTH FENDER WASHERS PAD (ONE AT EACH DOWNSPOUT <br />%9MLE CFKM ON EACH SIDE. CORNER). <br />SIMPSON 6" PROVIDE CLEANOUT IN UNDERGROUND CONDENSATE DRAIN. <br />WEDGE —ALL THICK CONCRETE REFER TO EXTERIOR CONDENSATE CLEANOUT DETAIL. GRADE OR <br />EXPANSION VALVE PAD (MIN. 2000 PSI PAVING <br />LIQUID LIQUID DIST. (TYP.) COVER TO BE FLUSH ABOVE GRADE . A A.. <br />'A* <br />A <br />.4 ....... ......... ..... <br />8" PVC TEE FITTING <br />LIQUID <br />KEY NOTE: EXTENSION SAME SIZE <br />AS CONDENSATE LINE <br />.......... <br />W S.S. WEDGE —ALL ANCHOR (BY SIMPSON OR EQUAL) EMBEDDED DEPTH sm 2V4- ......... <br />.......... .......... <br />MIN., AT MIN. 50 FROM CONCRETE EDGE,IN MIN. 2000 PSI CONCRETE. ALLOWABLE <br />SUCTION <br />LOAD 740 LBS. BASED ON 4.0 SAFETY FACTOR. . ....... <br />3/4-0 CONDENSATE DRAIN (SEE ANS) <br />COOUNG COIL 36" ...... PL <br />ASHER <br />S�ITEGLASS L <br />DR R SHUTOFF <br />8- <br />nkjnrkjCATr n0AW tCrC 01 AMCI <br />... ..... <br />EQUALIZER LINE (TYP.) MIN <br />TO DRYWELL FROM AH <br />SUCTIONa <br />2400 VIT. CLAY PIPE FILLED W/2- STONES <br />DUAL CRCUT <br />NOTE: PROVIDE SUCTION AND LIQUID LINES PER CU MANUFACTURER RECOMMENDATION <br />TYPICAL DX COIL PIPING DIAGRAM CU ANCHOR STRAP TYPICAL DRYWELL DETAL EXTERIOR CONDENSATE CLEANOUT DETAIL <br />NO SCALE filename: MD38 NO SCALE filename: MD111A NO SCALE NO SCALE <br />21 <br />z 14 <br />1_4 off, <br />% <br />6, tf. a " , 4. <br />r nel'77� <br />cn 0 <br />Z z <br />z0 cc) B; z <br />U ce 0 <br />1-4 <br />z <br />c k 2 0 <br />' 0 <br />0 0 LLI <br />. 04 <br />E- FD <br />WN <br />L)@ <br />LEANDRO A. ARROYO <br />FL. REG. NO. 12326 <br />CITY OF ZEPHYRHILLS <br />RENOVATION <br />OF <br />FIRE RESCUE <br />STATION NO. 2 <br />CONSTRUCTION <br />DOCUMENTS <br />12-07-2012 <br />CB+A #1202 <br />CANERDAY <br />BELFSKY <br />ARROYO <br />ARCHITECTS <br />800 SECOND AVENUE SOUTH <br />ST. PETERSBURG, FL 33701 <br />(727) 823-0675 <br />AA26000587 <br />MEnHANIeSAL IDETAILS 1'vZ�.l <br />1/81, = r-oll 0 m <br />