PLUMBING FIXTURE SCHEDULE
<br />BRANCH CONNECTIONS (D
<br />DESCRIPTION
<br />MANUFACTURER
<br />MODEL NO.
<br />WASTE
<br />C.W.
<br />H.W.
<br />WATER CLOSET — TANK/BOWL COUPLING SYSTEM, VITREOUS
<br />AMERICAN STANDARD
<br />2002.014
<br />CHINA, FLOOR MOUNTED 1.6 GPF, ELONGATED BOWL, SIPHON
<br />KOHLER
<br />K-3979
<br />ACTION JETTED BOWL, SIDE LEVER HANDLE, 2 BOLT CAPS.
<br />CRANE
<br />31372
<br />16 1/2- RIM HEIGHT.
<br />wc—i_
<br />SUPPLIES — 12 X 3/8" O.D., FLEXIBLE RISER, WALL
<br />CHICAGO
<br />1017
<br />3
<br />1/21
<br />FLANGE, LOOSE KEY HANDLE, LOCK—SHEILD CAP, 1/2-
<br />MCGUIRE
<br />H2166LKC
<br />INLET.
<br />BRASSCRAFT
<br />OR3512DL C
<br />aEAI — FINISH WHITE, HEAVY DUTY PLASTIC. ELONGATED
<br />BEMIS
<br />1655—SS/C
<br />BOWL, OPEN FRONT LESS COVER, STAINLESS STEEL HINGE
<br />OLSONITE
<br />95
<br />POSTS.
<br />CHURCH
<br />9500C
<br />I
<br />LAVATORI — WALL MOUNTED 20 1/2" X 18 1/4" SIZE,
<br />AMERICAN STANDARD
<br />0355.012
<br />VITREOUS CHINA, 4" CENTERS, SELF —DRAINING DECK,
<br />CRANE
<br />KOHLER
<br />1412—V
<br />K-2005
<br />FAUCET LEDGE, FRONT OVERFLOW, CONCEALED ARM
<br />SUPPORT, INSTALL WITH 29" CLEAR FROM FLOOR TO
<br />UNDERSIDE OF LAVATORY.
<br />TRIM — FAUCET, 4" COVER PLATE. SINGLE CONTROL
<br />CHICAGO
<br />2200-4
<br />HANDLE, LESS POP—UP, 4 3/4- SPOUT, 3/8" O.D. COPPER
<br />T&S BRASS
<br />B-2711
<br />INLET TUBES, 1/2 GPM AERATOR, SOFT —CLOSING VALVES,
<br />ZURN
<br />Z82200—CPU
<br />ADJUSTABLE LIMIT STOP, INTEGRAL FLOW CONTROL,
<br />POLISHED CHROME FINISH, INTEGRAL PERFORATED GRID
<br />L-1
<br />DRAIN, 1 1/4- TAILPIECE.
<br />SUPPLIES — ANGLE STOPS (1/2- I.P.S.) LOOSE KEY, C.P
<br />CHICAGO
<br />1017
<br />11/4
<br />1/2
<br />1/2
<br />F&
<br />NIPPLES, ESCUTCHEONS, 12- X 3/8- FLEX RISER,
<br />MCGUIRE
<br />ZURN
<br />H2165LKC
<br />ZH-8822—LR—LK
<br />HCI
<br />TRAP — CHROME PLATED CAST BRASS NTH CLEANOUT,
<br />MCGUIRE
<br />8872
<br />17 GAUGE SEAMLESS TUBULAR WALL BEAND, CAST
<br />ZURN
<br />Z8700
<br />BRASS SLIP NUTS, RUBBER WASHER, STEEL WALL
<br />SANITARY DASH
<br />R867-8
<br />FLANGE WITH SET SCREW. 1 1/4- O.D., OFFSET GRID
<br />DRAIN.
<br />CARRIER. — DURA—COATED CAST IRON, STEEL UPRIGHTS,
<br />ZURN
<br />ZR-1231
<br />CONCEALED ARMS AND SLEEVES, HEAVY CAST IRON
<br />JOSAM
<br />17100
<br />FEET, ADJUSTABLE HEADERS, ALIGNMENT TRUSS,
<br />J.R. SMITH
<br />0700
<br />MOUNTING FASTENERS, LESS ESCUTCHEONS.
<br />P—TRAP AND ANGLE VALVE ASSEMBLIES SHALL BE
<br />MCGUIRE
<br />PW 2000 WC
<br />INSULATED NTH MOLDED SEAMLESS ANTIMICROBIAL
<br />TRUEBRO
<br />MATERIAL. MINIMUM 3/16- THICKNESS, COLOR WHITE.
<br />OR EQUAL
<br />ELECTRIC WATER COOLER — DUAL HEIGHT, FULLY RECESSED
<br />ELKAY
<br />LRPBM28K
<br />IN WALL REFRIGERATION UNIT, 18# GAUGE TYPE 304 NICKEL
<br />HAWS
<br />BEARING POLISHED STAINLESS STEEL, FLEXI—GUIARD BUBBLER,
<br />OASIS
<br />"LIGHT' TOUCH" PUSH BAR, BUILT—IN FLOW REGULATOR,
<br />STAINLESS STEEL GRILLE, REMOVABLE LOUVERED FRONT
<br />VENTILATING GRILLE, STAINLESS STEEL BOTTOM COVER
<br />PLATE. STAINLESS STEEL GRILLE, REMOVABLE LOUVERED
<br />FRONT, MOUNTING FRAME.
<br />CAPACITIES: 7.5 GPH, 370 WATTS, 4.0 AMPS, 115V, 60HZ,
<br />SINGLE PHASE.
<br />EWC-1
<br />SUPPLIES — STRAIGHT STOP FITTING WITH LOOSE
<br />CHICAGO
<br />45—LKCP
<br />KEY, POLISHED CHROME PLATED SOLID BRASS
<br />MCGUIRE
<br />ST1 55LKSB
<br />11/4
<br />1/2
<br />CONSTRUCTION, METAL TEE HANDLE, J" NPT INLET &
<br />BRASSCRAFT
<br />SCR39 C
<br />Ej
<br />OUTLET, MOUNTING HARDWARE.
<br />J&�P — 1 1/4- X 1 1/4- CHROME PLATED, CAST BRASS,
<br />MCGUIRE
<br />8088
<br />ONE PIECE P—TRAP, CLEANOUT PLUG, NIPPLE AND CAST
<br />ZURN
<br />Z8710
<br />BRASS FLANGE, POLISHED CHROME THREADED BOTH ENDS.
<br />MOUNTING HEIGHT — COOLER SHALL BE INSTALLED WITH THE
<br />(HC) SPOUT A MAXIMUM OF 34' A.F.F. AND PROVIDE A MIN.
<br />OF 27" BETWEEN BOTTOM OF SUPPORT ARM AND FLOOR.
<br />MINIMUM MOUNTING REQUIREMENTS — 12" MINIMUM DEPTH
<br />REQUIRED BEHIND UNIT. REFER TO MANUFACTURERS WRITTEN
<br />SPECIFICATIONS PRIOR TO ROUGH —IN
<br />WATER HAMMER ARRESTOR — WROUGHT COPPER SHELL,
<br />JOSAM
<br />75000—S SERIES
<br />HYDRO —PNEUMATIC AIR CUSHION, TRIPLE O—RING SEALED
<br />SIOUX CHIEF
<br />"HYDRA —RESTER"
<br />PISTON, WROUGHT COPPER ADAPTER AND MALE THREADED
<br />ZURN—WILKINS
<br />1250 SERIES
<br />CONNECTION. SIZED PER STANDARD P.D.I. — WH201.
<br />WHA
<br />TYPE A = 'P.D.I.' SIZE A = 1-11 FIX. UNITS, 1/2- CONN.
<br />TYPE B = 'P.D.I.' SIZE B = 12-32 FIX. UNITS, 314" CONN.
<br />TYPE C = 'P.D.l.' SIZE C = 33-60 FIX. UNITS, 1 CONN.
<br />TYPE D = 'P.D.I.' SIZE D = 61-113 FIX. UNITS, 1" CONN.
<br />WASHING MACHINE FITTING — CENTER DRAIN GALVANIZED
<br />GUYGREYOR
<br />BB200TS
<br />OUTLET BOX, TOP SUPPLIES, lh- MIP/SWEAT CONX. VALVES,
<br />APPROVED EQUAL
<br />WMF
<br />2" THREADED DRAIN, QUARTER TURN VALVES.
<br />2
<br />N
<br />N
<br />PROVIDE IN —LINE WATER HAMMER ARRESTORS
<br />SIOUX CHIEF
<br />660—H
<br />FLOOR DRAIN — COATED CAST IRON BODY NTH NEOPRENE
<br />ZURN
<br />Z-415-1
<br />GASKET, COMBINA-nON INVERTIBLE MEM13RANE CLAMP &
<br />JOSAM
<br />PROVIDE DEEP SEAL TRAPS
<br />FD-1
<br />ADJUSTABLE COLLAR NTH SEEPAGE SLOTS, POLISHED NICKEL
<br />WATTS DRAINAGE
<br />WERE TRAP PRIMERS ARE
<br />BRONZE STRAINER NTH RAISED FLANGE. (REFER TO PLANS
<br />NOT INDICATED.
<br />FOR PIPE SIZES)
<br />PLUMBING
<br />SYMBOL LEGEND
<br />SYMBOL
<br />DESCRIPTION
<br />ABBREV.
<br />—CD— — —
<br />CONDENSATE DRAIN
<br />CID
<br />—ST— — —
<br />STORM DRAINAGE
<br />ST
<br />—SD— — —
<br />SECONDARY EMERGENCY
<br />ROOF DRAINAGE
<br />SID
<br />—S— — —
<br />SANITARY DRAINAGE
<br />S
<br />—AW— — —
<br />ACID WASTE
<br />AW
<br />—GW— — —
<br />GREASE WASTE
<br />GW
<br />V— — — —
<br />VENT PIPING
<br />V
<br />COLD WATER PIPING
<br />C.W.
<br />HOT WATER PIPING
<br />H.W.
<br />HOT WATER RECIRULATING
<br />H.W.R.
<br />_G
<br />GAS PIPING
<br />G
<br />—A
<br />COMPRESSED AIR PIPING
<br />>
<br />DIRECTION OF FLOW
<br />SWING CHECK VALVE
<br />SHUTOFF VALVE
<br />SOLENOID VALVE
<br />BALANCING VALVE
<br />PRESSURE REGULATING VALVE
<br />G
<br />ELBOW TURNEDDOWN
<br />(>--
<br />ELBOW TURNED UP
<br />0
<br />TEE TURNED UP
<br />8 -
<br />TEE TURNED DOWN
<br />oc—
<br />P-TRAP
<br />F.D.
<br />0
<br />FLOOR DRAIN
<br />F.D.
<br />0
<br />HUB DRAIN
<br />H.D.
<br />--H
<br />HOSE BIB
<br />H.B.
<br />El
<br />FLOOR SINK
<br />F.S.
<br />�ON
<br />ROOF DRAIN ABOVE
<br />R.D.
<br />T&P RELIEF VALVE (AGA RATED)
<br />CONNECT TO EXISTING UTILITIES
<br />WATER HAMMER ARRESTOR
<br />INSERT INDICATES DETAIL NUMBER
<br />INSERT INDICATES SHEET NUMBER
<br />INSERT INDICATES RISER NUMBER
<br />INSERT INDICATES SHEET NUMBER
<br />INSERT INDICATES ENLARGED PLAN NUMBER
<br />INSERT INDICATES SHEET NUMBER
<br />C3
<br />BY PLUMBING CONTRACTOR
<br />REFER TO CIVIL PLANS FOR CONTINUATION
<br />SHUT-OFF VALVE IN VALVE BOX
<br />INSERT INDICATES INVERT ELEVATION
<br />I.E.
<br />TRAP PRIMER
<br />TP
<br />ABOVE FINISHED FLOOR
<br />A.F.F.
<br />CONTINUATIONE
<br />CONT.
<br />DISHWASHER
<br />DW
<br />WASHER
<br />W
<br />DRAWING
<br />DWG
<br />NOT TO SCALE
<br />N.T.S.
<br />RAIN WATER LEADER
<br />RWL
<br />VENT THROUGH ROOF
<br />VTR
<br />FROM BELOW
<br />FB
<br />FROM ABOVE
<br />FA
<br />BELOW FLOOR
<br />BF
<br />BELOW GRADE
<br />BG
<br />WATER FIXTURE UNIT
<br />W.F.U.
<br />DRAINAGE FIXTURE UNIT
<br />D.F.U.
<br />EXISTING CONDITION
<br />(E)
<br />WALL CLEANOUT
<br />Wco
<br />FLOOR CLEANOUT
<br />FCO
<br />EXTERIOR CLEANOUT
<br />co
<br />VENT THROUGH ROOF
<br />VTR
<br />PLUMBING GENERAL NOTES
<br />1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY
<br />FITTINGS AS REQUIRED BY ALL APPLICABLE CODES AND GOVERNING
<br />AUTHORITIES.
<br />2. CONTRACTOR SHALL VERIFY AND CORRECT AS REQUIRED TO MEET ALL
<br />CODES AND REGULATIONS ANY POSSIBLE DISCREPANCIES BETWEEN TYPE
<br />AND SIZE OF CONNECTION SPECIFIED IN PLUMBING FIXTURE SCHEDULE
<br />AND FIXTURES ACTUALLY INSTALLED ON THE SITE.
<br />3. SANITARY PIPING 2- SHALL HAVE A 1/4- PER FT. SLOPE. PIPING 3- &
<br />LARGER SHALL HAVE A 1/8- PER FT. SLOPE MINIMUM.
<br />4. COORDINATE SANITARY VENTS NTH HVAC O.A. INTAKES. PROVIDE AT
<br />LEAST 10'—Om DISTANCE FROM VENT STACKS AND INTAKE VENTS.
<br />5. VALVES AND FITTINGS SHALL BE OF SAME SIZE OF LINE ON WHICH THEY
<br />ARE LOCATED, UNLESS OTHERWISE INDICATED ON DRAWINGS.
<br />6. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES.
<br />7. CONTRACTOR SHALL FIELD VERIFY ALL GIVEN MEASUREMENTS PRIOR TO
<br />LAYING AND CONNECTING ALL SANITARY AND WASTE PIPING AND NOTIFY
<br />ARCHITECT OF ANY DISCREPANCIES.
<br />8. AIR CHAMBERS SHALL NOT BE CONSIDERED AN EQUAL TO WATER HAMMER
<br />ARRESTORS. WATER HAMMER ARRESTORS (WHA) SHALL BE INSTALLED ON
<br />ALL GROUP TOILETS AND ON THE BRANCH LINES TO INDIVIDUAL FIXTURES.
<br />ALL APPLICATIONS SHAH BE INSTALLED AS PER STANDARD PDI—M201.
<br />REFER TO PLUMBING FIXTURES SCHEDULE FOR SPECIFICATIONS. PROVIDE
<br />ACCESS PANELS IN THE CEILING AS REQUIRED FOR ACCESSIBILITY AND
<br />MAINTENANCE. PROVIDE & INSTALL TYPE "A" ON ALL INDIVIDUAL FIXTURES
<br />THAT ARE NOT LOCATED IN GROUP TOILETS OR NOT NOTED ON RISER
<br />DIAGRAMS.
<br />9. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE RATING AND
<br />WEATHERPROOFING INTEGRITY OF ALL PIPING AND PENETRATIONS. REFER
<br />TO DETAILS.
<br />10. ALL WATER SUPPLY AND SANITARY LINES SHALL BE RUN AS CLOSE TO
<br />PLANS AS POSSIBLE NTH NO CHANGES IN SIZING.
<br />11. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY
<br />SUPPORTING DEVICES FOR ALL FIXTURES INCLUDED IN CONTRACT OR
<br />HEREIN SPECIFIED OR OTHERWISE.
<br />12. ALL DRAINAGE PIPING SHALL BE MARKED WITH THE SEAL OF APPROVAL
<br />OF THE NATIONAL SANITATION FOUNDATION.
<br />13. ROUTE ALL PIPING CONCEALED ABOVE CEILINGS, WITHIN WALLS, OR IN
<br />CHASES EXCEPT AS SPECIFICALLY NOTED, OR IN MECHANICAL ROOMS.
<br />14. PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE
<br />NON— ACCESSIBLE CEILINGS. REFER TO ARCHITECTURAL DRAWINGS FOR
<br />CEILING TYPES.
<br />15. SEE ARCHITECTURAL DRAWINGS FOR EXACT ROUGH —IN LOCATION OF
<br />PLUMBING FIXTURES.
<br />16. PROVIDE A PRE MANUFACTURED DRAIN INSULATING COVER ON ALL SINKS
<br />AND LAVATORIES DESIGNATED AS A HANDICAP FIXTURE. REFER TO
<br />PLUMBING DRAWINGS AND THE ARCHITECTS DRAWINGS FOR DESIGNATIONS.
<br />17. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO MICH
<br />NEW SEWER LINES ARE TO BE CONNECTED BEFORE INSTALLATION OF NEW
<br />SEWER LINE.
<br />18. CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT CONNECTIONS OF
<br />DISSIMILAR METALS.
<br />19. CONTRACTOR SHALL ROUGH —IN ALL WASTES AND SUPPLIES TO SPECIAL
<br />EQUIPMENT ACCORDING TO MANUFACTURER'S SHOP DRAWINGS AND MAKE
<br />FINAL CONNECTIONS. ALL SUPPLIES SHALL BE VALVED. INSTALL VACUUM
<br />BREAKERS WHERE REQUIRED BY CODE.
<br />20. PROVIDE REDUCED PRESSURE BACKFLOW PREVENTERS FOR DOMESTIC
<br />WATER SUPPLIES AS REQUIRED BY LOCAL WATER PURVEYORS.
<br />21. DO NOT PENETRATE WALL FOOTINGS NTH PIPING, COORDINATE NTH
<br />GENERAL CONTRACTOR TO DROP FOOTINGS AS REQUIRED TO CLEAR
<br />PLUMBING SERVICES WHERE ABSOLUTELY NECESSARY. ANY PIPING
<br />PENETRATING A BEARING WALL OR FOOTING MUST BE SLEEVED AND
<br />LOCATION APPROVED BY STRUCTURAL ENGINEER.
<br />22. THE CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO FIXTURES.
<br />23. ASSEMBLE ALL FIXTURES AND EQUIPMENT SHIPPED LOOSE MICH YOU ARE
<br />REQUIRED TO MAKE FINAL CONNECTIONS TO, WHETHER FURNISHED BY YOU
<br />OR BY OTHERS, (I.E. WATER FAUCETS, TRIM OR TAILPIECE ETC.)
<br />24. ALL INSTALLATIONS OF FLOOR DRAINS AND HUB DRAINS (LOCATED IN
<br />MECHANICAL ROOMS) SHALL BE COORDINATED WITH THE MECHANICAL
<br />EQUIPMENT AND HOUSEKEEPING PADS PRIOR TO ROUGH —IN OF DRAINS.
<br />25. PLUMBER SHALL BE LICENSED BY STATE AND LOCAL AUTHORITIES TO
<br />INSTALL GAS PIPING.
<br />0
<br />to
<br />R_
<br />03
<br />cm
<br />NZ
<br />C;
<br />Z
<br />z 0
<br />u
<br />co
<br />CQ
<br />ul:l Zs
<br />0
<br />m
<br />z
<br />0 c
<br />c
<br />0 LU
<br />cli
<br />C14
<br />LEANDRO A. ARROYO
<br />FL. REG. NO. 12326
<br />CITY OF ZEPHYRHILLS
<br />RENOVATION
<br />OF
<br />FIRE RESCUE
<br />STATION NO. 2
<br />CONSTRUCTION
<br />DOCUMENTS
<br />12-07-2012
<br />CB+A #1202
<br />CANERDAY
<br />BELFSKY
<br />ARROYO
<br />ARCHITECTS
<br />800 SECOND AVENUE SOUTH
<br />ST. PETERSBURG, FL 33701
<br />(727) 823-0675
<br />AA26000587
<br />'10LUMBIN(S LE(SEND AND SCHEDULE