- . - - - - I I I I - _I - - - - I I I __L_ - - - I I I _L - , I larw 1 11 ! _____j - ___ _L I __ - __ - - I - __ _I <br />A, .1, <br />ELECTRICAL SPECIFICATIONS <br />GENERAL ELECTRICAL SPECIFICATIONS <br />1 . THE ELECTRICAL CONTRACTOR REFERRED TO HEREAFTER, AS THE <br />"CONTRACTOR" SHALL PROVIDE COMPLETE ELECTRICAL SYSTEMS AS <br />INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN. <br />2. CONTRACTOR SHALL PROVIDE PROTECTIVE DEVICES, CONDUCTORS, <br />SUPPORTS, RACEWAYS, AND MISCELLANEOUS MATERIALS TO SERVE <br />ALL DEVICES REQUIRING ELECTRICAL POWER. <br />3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, FEES, AND <br />INSPECTIONS REQUIRED TO COMMENCE AND COMPLETE ELECTRICAL <br />WORK. <br />4. CONTRACTOR SHALL CONDUCT A THOROUGH SITE INSPECTION TO <br />FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS AND ALL ASPECTS OF <br />HIS SCOPE OF WORK. SUCH AN INSPECTION SHALL BE CONDUCTED <br />PRIOR TO SUBMITTING A BID. <br />5. CONTRACTOR SHALL REFER TO INTERIOR ARCHITECTURAL CASE WORK <br />ELEVATIONS FOR EXACT MOUNTING HEIGHTS AND/OR LOCATIONS OF <br />SWITCHES, OUTLETS, AND WIRING DEVICES. <br />6. CONTRACTOR SHALL MAINTAIN A COMPLETE TEMPORARY POWER AND <br />LIGHTING SYSTEM DURING CONSTRUCTION. <br />7. THE CONTRACTOR SHALL PROVIDE, DROP CLOTH, RUBBER MATS AND, <br />PLYWOOD COVERS FOR OWNERS EQUIPMENT SUSCEPTIBLE TO DAMAGE <br />DURING CONSTRUCTION. VERIFY SPECIFIC LOCATIONS WITH OWNER'S <br />REPRESENTATIVE. <br />8. ALL WORK SHALL BE PERFORMED DURING PERIODS ACCEPTABLE TO <br />THE OWNER. SCHEDULE ALL WORK WITH THE OWNER'S <br />REPRESENTATIVE BEFORE PROCEEDING. <br />9. THE CONTRACTOR SHALL PERFORM TEMPORARY WORK NECESSARY TO <br />MAINTAIN CONTINUITY OF ELECTRICAL SERVICE WHEN CONNECTION IS <br />MADE TO EXISTING SYSTEMS AND FACILITIES. EXISTING SERVICE SHALL <br />NOT BE INTERRUPTED WITHOUT PRIOR CONSENT OF THE OWNER'S <br />REPRESENTATIVE. <br />10. AT PROJECT COMPLETION, THE CONTRACTOR SHALL INSURE THAT ALL <br />ELECTRICAL SYSTEMS OPERATE PROPERLY. CONTRACTOR SHALL <br />DEMONSTRATE OPERATION OF EACH SYSTEM WITH THE OWNER'S <br />REPRESENTATIVE. <br />11. CONTRACTOR IS TO PROVIDE THE OWNER WITH AS -BUILT DRAWINGS OF <br />THE SINGLE LINE DIAGRAM OF THE ELECTRICAL DISTRIBUTION SYSTEM <br />AND FLOOR PLANS INDICATING LOCATIONS OF EQUIPMENT SERVED. <br />PROVIDE OPERATIONS AND MAINTENANCE MANUALS FOR EQUIPMENT <br />REQUIRING MAINTENANCE AND THE CONTACT INFORMATION FOR A <br />QUALIFIED SERVICE AGENCY. <br />12. CONTRACTOR SHALL COORDINATE AND VERIFY WITH LOCAL POWER <br />COMPANY THE FOLLOWING: <br />- EXACT LOCATION OF SERVICE CONNECTION <br />- ELECTRICAL CHARACTERISTICS (VOLTAGE AND PHASING) <br />- AVAILABLE FAULT CURRENT <br />- METERING REQUIREMENTS <br />12. "PROVIDE" SHALL MEAN "FURNISH AND INSTALL". <br />CODES AND STANDARDS <br />1 . ELECTRICAL WORK HAS BEEN DESIGNED TO AND SHALL COMPLY WITH: <br />- NFPA 70 2017 (NATIONAL ELECTRICAL CODE) <br />- NFPA 72 2016 (NATIONAL FIRE ALARM & SIGNALING CODE) <br />- FBC 2020 7TH EDITION <br />- NFPA 101 (LIFE SAFETY CODE) <br />- FLORIDA FIRE PREVENTION CODE. <br />- CODES SPECIFIC TO OTHER SECTIONS HEREIN <br />2. ELECTRICAL WORK SHALL COMPLY WITH ALL LOCAL AND STATE <br />ELECTRICAL CODES AND IN ACCORDANCE WITH REQUIREMENTS OF THE <br />AUTHORITY HAVING JURISDICTION (AHJ). <br />QUALITY <br />1 . WORKMANSHIP SHALL BE HIGH QUALITY AND FOLLOW INDUSTRY <br />STANDARDS. SUBSTANDARD WORK WILL BE REJECTED. THE <br />CONTRACTOR IS RESPONSIBLE FOR REPAIR AND REWORK TO RECTIFY <br />SUBSTANDARD WORK. QUALITY OF WORK SHALL BE DETERMINED BY <br />THE OWNER'S REPRESENTATIVE AND/OR ENGINEER OF RECORD. <br />INTERFERENCES <br />1 . PLANS ARE GENERALLY DIAGRAMMATIC. THE CONTRACTOR SHALL <br />COORDINATE WITH THE OTHER TRADES SO THAT INTERFERENCES <br />BETWEEN CONDUITS, PIPING, EQUIPMENT, DUCTS, AND STRUCTURAL <br />WORK WILL BE AVOIDED. IN SUCH CASE, IF THE CONTRACTOR FAILS TO <br />COORDINATE WITH OTHER TRADES AND INTERFERENCES ARE ALLOWED <br />TO DEVELOP, THE OWNER'S AUTHORIZED REPRESENTATIVE WILL DECIDE <br />WHICH EQUIPMENT, DUCT, CONDUIT, ETC., MUST BE RELOCATED, <br />REGARDLESS OF WHICH WAS INSTALLED FIRST. ELECTRICAL REWORK <br />REQUIRED TO CORRECT INTERFERENCES WILL BE AT THE <br />CONTRACTORS EXPENSE. <br />MATERIALS, <br />1 . ALL ELECTRICAL EQUIPMENT AND MATERIALS SHALL BE NEW AND <br />APPROVED BY UNDERWRITERS LABORATORY FOR THE APPLICATION <br />AND SHALL BEAR A UL LABEL. <br />2. ELECTRICAL ENCLOSURES SHALL BE NEMA RATED. UNLESS OTHERWISE <br />NOTED, ENCLOSURE RATINGS SHALL ADHERE TO THE FOLLOWING: <br />- NEMAl INDOOR <br />- NEMA 3R OUTDOOR <br />- NEMA4 CORROSIVE ENVIRONMENT <br />GUARANTEE <br />1. CONTRACTOR SHALL GUARANTEE ALL WORK FOR A PERIOD OF ONE <br />YEAR FROM DATE OF OWNER'S ACCEPTANCE. THE CONTRACTOR SHALL <br />RECTIFY ANY DEFECTS DUE TO FAULTY MATERIALS OR WORKMANSHIP <br />AND PAY FOR DAMAGE CAUSED BY FAILURE AND REWORK. THE OWNER <br />WILL GIVE NOTICE OF DEFECTS WITH REASONABLE PROMPTNESS AFTER <br />DISCOVERY. THE CONTRACTOR SHALL START REWORK WITHIN TEN (10) <br />WORKING DAYS OF NOTIFICATION AND COMPLETE REPAIRS IN A TIMELY <br />MANNER. <br />IDENTIFICATION OF EQUIPMENT <br />1 . LABEL ALL ELECTRICAL EQUIPMENT WITH ENGRAVED LAMINATED <br />PLASTIC NAMEPLATE THAT CLEARLY DESCRIBES THE EQUIPMENT NAME, <br />VOLTAGE, AMPERAGE RATING, AND FUNCTION. NAMEPLATES SHALL BE <br />BLACK BACKGROUND WITH WHITE STENCILED UPPER CASE LETTERING A <br />MINIMUM OF 3/16" IN HEIGHT. USE RED BACKGROUND FOR EMERGENCY <br />SYSTEMS. <br />2. INSTALL VINYL CLOTH SELF-ADHESIVE CIRCUIT LABELS ON ALL WIRE <br />AND CABLE IN JUNCTION BOXES, WIRE TROUGHS, AND PANELBOARD <br />WIRING GUTTERS. <br />3. IDENTIFY JUNCTION BOXES WITH PERMANENT MARKER INDICATING <br />PANELBOARD AND CIRCUIT NUMBERS OF WIRING CONTAINED WITHIN. <br />4. PROVIDE TYPEWRITTEN PANELBOARD DIRECTORIES WITH ACCURATE AS <br />BUILT INFORMATION. DIRECTORIES SHALL REFLECT TYPE OF LOAD AND <br />AREA SERVED FOR EACH BREAKER. <br />RACEWAYS AND FITTINGS <br />1 . CONDUIT SHALL BE PROPERLY ALIGNED, GROUPED AND SUPPORTED. <br />EXPOSED CONDUIT SHALL BE INSTALLED AT RIGHT ANGLES TO OR <br />PARALLEL TO THE PRINCIPAL STRUCTURAL MEMBERS. CONDUIT SHALL <br />BE SUPPORTED AT INTERVALS NOT EXCEEDING 8 FEET. CONDUIT SHALL <br />BE SUPPORTED FROM STRUCTURE AND NOT FROM CEILING SUPPORT <br />SYSTEM. <br />2. CONDUITS SHALL BE INSTALLED CONCEALED WHERE POSSIBLE EXCEPT <br />IN ELECTRICAL AND MECHANICAL ROOMS UNLESS NOTED OTHERWISE <br />ON THESE PLANS. <br />3. ELECTRICAL METAL TUBING (EMT) SHALL BE GALVANIZED STEEL FOR ALL <br />INSTALLATIONS. COUPLINGS AND CONNECTORS SHALL BE <br />COMPRESSION TYPE. <br />4. FLEXIBLE METALLIC CONDUIT IN DRY LOCATIONS SHALL BE <br />UNDERWRITERS'APPROVED, STEEL, ZINC COATED, SINGLE STRIP TYPE. <br />FITTINGS SHALL BE AS MANUFACTURED BY THOMAS AND BETTS <br />"TITE-BITE", OR APPROVED EQUAL. <br />5. CONDUIT AND WIRING PENETRATING RATED FLOORS AND WALLS SHALL <br />BE SEALED WITH A UL RATED ASSEMBLY TO MAINTAIN FIRE RATING AND <br />INTEGRITY OF SEPARATION IN ACCORDANCE WITH FBC 713. REFER TO <br />ARCHITECTURAL DOCUMENTS FOR ALL FLOOR AND WALL RATINGS AS <br />WELL AS DETAILS IDENTIFYING THRU-WALL, FLOOR AND CEILING <br />PENETRATIONS. <br />BOXES <br />1. BOXES SHALL BE RIGIDLY MOUNTED AND COVERED WITH MATCHING <br />PLATE. OPEN KNOCK -OUTS OR HOLES IN BOXES SHALL BE PLUGGED <br />WITH A SUITABLE BLANKING DEVICE. <br />CONDUCTORS <br />1 . ALL LIGHTING BRANCH CIRCUIT CONDUCTORS AND BRANCH CIRCUIT <br />CONDUCTORS OVER 75'IN LENGTH SHALL BE SOLID NO. 10 AWG COPPER <br />UNLESS NOTED OTHERWISE. ALL BRANCH CIRCUIT CONDUCTORS UNDER <br />761N LENGTH SHALL BE SOLID NO. 12 AWG COPPER UNLESS NOTED <br />OTHERWISE. <br />2. ALLOW SUFFICIENT CABLE SLACK IN BOXES, OUTLETS AND CABINETS TO <br />MAKE CONNECTION AND INSURE THERE IS NO BINDING AT THE <br />SPLICE/TAP. <br />3. THE USE OF METAL CLAD CABLE (MC -CABLE), AS DEFINED BY NEC 330.2, <br />SHALL BE PERMISSABLE FOR THIS APPLICATION. INSTALLATION MUST <br />COMPLY WITH ALL REQUIREMENTS SET FORTH IN NEC ARTICLE 330. <br />4. CONDUCTORS SHALL BE COPPER. UNLESS OTHERWISE NOTED, <br />INSULATION SHALL BE DUAL TYPE THHNrrHWN 75'C. CONDUCTORS <br />SHALL BE COLOR CODED IN ACCORDANCE WITH NFC 70. COLOR CODING <br />SHALL BE BY MEANS OF COLORED INSULATING MATERIAL, COLORED <br />BRAID OR JACKET OVER THE INSULATION OR BY MEANS OF SUITABLE <br />COLORED, PERMANENT, NON -AGING, INSULATING TAPE APPLIED TO <br />CONDUCTORS AT EACH CABINET OR JUNCTION POINT. THE FOLLOWING <br />SYSTEM OF COLOR CODING SHALL BE ADHERED TO: <br />- GROUND LEADS: GREEN <br />- 120/208 NEUTRAL CONDUCTOR: WHITE <br />- 120/208 VOLT, PHASE CONDUCTORS: BLACK, RED, BLUE <br />6. EXISTING FACILITIES: WHERE EXISTING COLOR CODING SCHEME <br />DIFFERS FROM THAT SPECIFIED HEREIN, CONTRACTOR SHALL ADHERE <br />TO ESTABLISHED BUILDING STANDARD. ADVISE PROJECT <br />ADMINISTRATOR IN WRITING OF COLOR CODING SCHEME BEING USED. <br />7. THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE <br />CONSISTENTLY FOLLOWED THROUGHOUT. <br />GROUNDING <br />1 . ALL INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND <br />EFFECTIVELY GROUNDED AS REQUIRED BY NFPA 70 AND AS SPECIFIED <br />HEREIN. <br />2. METALLIC RACEWAYS SHALL BE MECHANICALLY AND ELECTRICALLY <br />SECURE AT ALL JOINTS AND AT ALL BOXES, CABINETS, FITTINGS, AND <br />EQUIPMENT. METALLIC RACEWAYS SHALL BE CONNECTED TO A DIRECT <br />GROUND AT POINT OF ELECTRICAL SERVICE ENTRANCE AND SHALL BE <br />ELECTRICALLY CONTINUOUS THROUGHOUT THE ENTIRE SYSTEM. <br />3. ALL GROUND CONDUCTORS SHALL BE INSULATED COPPER UNLESS <br />OTHERWISE NOTED. <br />4. RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR <br />RECEPTACLES, LIGHT FIXTURES AND SIMILAR CIRCUITS (NEW BRANCH <br />CIRCUITS) SHALL BE PROVIDED WITH A PARITY SIZED GREEN EQUIPMENT <br />GROUND CONDUCTOR. GROUND CONDUCTOR SHALL BE INSTALLED IN <br />ENTIRE RACEWAY SYSTEM INCLUDING WALL SWITCHES AND FLEXIBLE <br />CONDUIT TO LIGHT FIXTURES. EQUIPMENT GROUND CONDUCTOR SIZES <br />FOR CIRCUITS WITH PHASE CONDUCTORS LARGER THAN NO. 12 AWG <br />ARE INDICATED ON DRAWINGS. <br />LIGHTING <br />1 . CONTRACTOR SHALL PROVIDE ALL MOUNTING HARDWARE AND LIGHTING <br />OPTIONS TO PROVIDE A PROPER LIGHTING INSTALLATION. <br />2. FIXTURES SHALL BE PROPERLY SUPPORTED AND ALIGNED. LIGHTING <br />FIXTURES SHALL BE CLEANED AND LAMPED IMMEDIATELY PRIOR TO <br />FINAL INSPECTION. <br />WIRING DEVICES <br />1. LIGHTING TOGGLE SWITCHES SHALL BE 20 AMP, SPECIFICATION GRADE <br />TOGGLE TYPE SWITCHES. ALL SWITCHES AND COVERPLATES SHALL BE <br />GRAY. ALL COVER PLATES SHALL BE STAINLESS STEEL. ALL ADJACENT <br />SWITCHES SHALL BE GANGED IN ONE COMMON COVERPLATE/BOX. <br />LOCATIONS AND HEIGHTS SHALL BE COORDINATED WITH DOOR SWINGS <br />AND COUNTER HEIGHTS. <br />2. DUPLEX AND DOUBLE DUPLEX RECEPTACLES SHALL BE 20 AMP, 125 <br />VOLT RATED, SPECIFICATION GRADE. RECEPTACLES SHALL HAVE A <br />GREEN GROUNDING SCREW TERMINAL AND A SELF GROUNDING CLIP. <br />ALL RECEPTACLES SHALL BE GRAY WITH STAINLESS STEEL COVER <br />PLATES. EXACT LOCATIONS AND MOUNTING HEIGHTS SHALL BE <br />COORDINATED WITH THE COUNTER HEIGHTS AND ALL LOCATIONS SHALL <br />BE VERIFIED WITH THE OWNER PRIOR TO ROUGH -IN. GFCI TYPE <br />RECEPTACLES SHALL BE 20 AMP 125V, NON FEED-THRU TYPE. <br />GENERAL NOTES <br />I . THE CONTRACTOR SHALL REFER TO THE ELECTRICAL SPECIFICATIONS <br />FOR ADDITIONAL DESIGN STANDARDS. THE ELECTRICAL SPECIFICATIONS <br />ARE A BINDING PART OF THE CONSTRUCTION DOCUMENTS. <br />2. ALL MATERIALS USED FOR CONSTRUCTION SHALL BE INSTALLED IN A <br />NEAT AND WORKMANLIKE MANNER. RACEWAY AND CABLES SHALL RUN <br />PARALLEL OR PERPENDICULAR TO WALL AND CEILING STRUCTURES FOR <br />A NEAT APPEARANCE. ALL MATERIAL AND INSTALLATION WILL BE <br />SUBJECT TO OWNER'S APPROVAL. COORDINATE AND SCHEDULE <br />INSPECTIONS WITH THE AHJ AND THE OWNER ACCORDINGLY. <br />3. PRIOR TO ROUGH -IN FOR LIGHTING SWITCHES, VERIFY ALL DOOR <br />SWINGS WITH ARCHITECTURAL PLANS. <br />4. ARRANGE LIGHTING FIXTURES IN ACCORDANCE WITH THE <br />ARCHITECTURAL REFLECTED CEILING PLANS. <br />5. COORDINATE LIGHTING FIXTURES INSTALLATION WITH GRILLES, <br />DIFFUSERS, SPRINKLER HEADS, AND ACCESS PANELS, PROVIDE FIXTURE <br />MOUNTING BRACKETS, ACCESSORIES, PLASTER FRAMES, ETC. SUITABLE <br />FOR THE CEILING TYPES INDICATED ON THE ARCHITECTURAL PLANS. <br />6. SYMBOLS NOT LISTED IN THE LEGEND ARE IDENTIFIED WHERE THEY <br />OCCUR ON THE DRAWINGS. <br />7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING FIRE STOPPING <br />AT WALL, FLOOR AND CEILING PENETRATIONS WHERE CONDUIT <br />PENETRATIONS OCCUR IN FIRE RATED CONSTRUCTION. FIRE STOPPING <br />AT CONDUIT PENETRATIONS SHALL BE Ul. LISTED. <br />8. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC ONLY. FURNISH ALL <br />REQUIRED JUNCTION BOXES, PULL BOXES, FITTINGS, CONDUIT BODIES, <br />SUPPORT, ACCESS DOORS, HARDWARE, ACCESSORIES, ETC. REQUIRED <br />FOR A COMPLETE AND WORKING ELECTRICAL SYSTEM, WHETHER OR <br />NOT SUCH EQUIPMENT IS INDICATED ON THE DRAWINGS. <br />9. THE CONTRACTOR SHALL COORDINATE WITH ALL CONTRACT <br />DOCUMENTS AND EQUIPMENT SHOP DRAWINGS. <br />10. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER <br />TRADES BEFORE INSTALLATION OF HIS WORK IN CHASES, CEILING <br />SPACES AND OTHER AREAS WHERE CONFLICT MAY OCCUR. <br />11. REFER TO MECHANICAL, PLUMBING AND FIRE PROTECTION DRAWINGS <br />FOR EXACT LOCATION AND REQUIREMENTS OF MECHANICAL, PLUMBING <br />AND FIRE PROTECTION EQUIPMENT. <br />12. ALL ELECTRICAL EQUIPMENT AND MATERIAL SHALL BE NEW AND FREE <br />FROM DEFECT EXCEPT WHERE SPECIFICALLY SHOWN TO REUSE <br />EXISTING MATERIAL. ALL EQUIPMENT AND MATERIAL USED SHALL BE <br />LISTED AND LABELED UNDERWRITER'S LABORATORY (U.L.). <br />13. ALL WORK SHALL BE SUITABLE FOR THE ENVIRONMENT THAT IT IS <br />INSTALLED. <br />14. COORDINATE THE INSTALLATION OF THE UTILITY TRANSFORMER WITH <br />THE APPROPRIATE POWER COMPANY. CONFIRM WITHIN 10 DAYS OF THE <br />AWARD OF CONTRACT THAT THE AVAILABLE FAULT CURRENT AT THE <br />TRANSFORMER SECONDARY BUSHINGS DOES NOT EXCEED THE <br />DESIGNED FAULT CURRENT AT THE SERVICE ENTRANCE EQUIPMENT. <br />NOTIFY THE ENGINEER IMMEDIATELY IF THE DESIGNED FAULT CURRENT <br />IS EXCEEDED. <br />15. VISIT THE SITE OF THE PROPOSED PROJECT TO BECOME FAMILIAR WITH <br />CONDITIONS AND NATURE OF THE WORK PRIOR TO SUBMITTING BIDS. <br />NOTIFY THE ENGINEER OF DISCREPANCIES OR OMISSIONS FOR <br />INTERPRETATION OR DECISION PRIOR TO SUBMITTING BIDS. SUBMISSION <br />OF A PROPOSAL WILL BE EVIDENCE THAT SUCH FAMILIARIZATION HAS <br />BEEN ATTAINED. <br />16. WHERE CONTRACTOR PROPOSES ALTERNATE SOLUTIONS, DIFFERENT <br />ROUTINGS OF CONDUIT, DIFFERENT LOCATIONS OF EQUIPMENT, ETC. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OF THE <br />RAMIFICATIONS OF THE PROPOSED CHANGE THAT ARE NOT INCLUDED IN <br />HIS PROPOSAL, BUT BECOME APPARENT AT A LATER DATE, AND SHALL <br />BE RESPONSIBLE FOR ALL COST AND CONSEQUENCES OF CORRECTING <br />ANY AND ALL CONFLICTS, DEFICIENCIES OR PROBLEMS THAT INCREASE <br />COST, INCREASE CONSTRUCTION TIME OR CREATE CODE VIOLATIONS. <br />17. INFORMATION SHOWN ON THE DRAWINGS AS TO THE LOCATION OF <br />EXISTING UTILITIES HAS BEEN PREPARED FROM THE MOST RELIABLE <br />DATA AVAILABLE TO THE ENGINEER. IT IS TO BE UNDERSTOOD THAT <br />UNFORESEEN CONDITIONS PROBABLY EXIST AND NEW WORK MAY NOT <br />BE LOCATED EXACTLY AS SHOWN ON THE DRAWINGS. COORDINATION <br />WITH OTHER TRADES FOR LOCATION AND BURIAL DEPTHS WILL BE <br />REQUIRED AND ANY SUCH REQUIRED DEVIATIONS SHALL BE <br />CONSIDERED PART OF THIS SCOPE OF WORK. SITE UTILITY <br />INFORMATION IS NOT GUARANTEED, THEREFORE THE CONTRACTOR <br />SHALL FIELD VERIFY THE EXACT LOCATIONS AND DEPTHS OF EXISTING <br />UTILITIES PRIOR TO BEGINNING WORK. PROTECT ANY EXISTING UTILITIES <br />TO REMAIN FROM DAMAGE DURING THE COURSE OF CONSTRUCTION <br />18. PROVIDE DEDICATED NEUTRAL WIRES FOR ALL BRANCH CIRCUITS U.N.O. <br />19. WHERE THE WORD -PROVIDE" IS USED, THIS SHALL MEAN -FURNISH AND <br />INSTALL". <br />20. COMPLY WITH SAFETY REGULATIONS INCLUDING BUT NOT LIMITED TO <br />OSHA, NFPA-70E AND ALL ELECTRICAL SAFETY REGULATIONS. <br />21. PROVIDE GROUNDING AND BONDING OF ALL METALLIC RACEWAY, <br />BOXES, WIREWAY, DEVICES AND EQUIPMENT IN ACCORDANCE WITH THE <br />NEC. PROVIDE GROUNDING CONDUCTOR IN ALL POWER CONDUITS. <br />22. INSTALL ALL DEVICES AND EQUIPMENT IN ACCORDANCE TO THE <br />MANUFACTURER'S RECOMMENDATIONS AND U.L. REQUIREMENTS. <br />23. WHERE THE SIZE OF A JUNCTION BOX. PULL BOX OR WIREWAY IS NOT <br />INDICATED ON THE DRAWINGS, THE SIZE SHALL BE SELECTED IN <br />ACCORDANCE WITH THE NEC. WHERE THE ENCLOSURE TYPE OF THE <br />JUNCTION BOX, PULL BOX OR WIREWAY IS NOT INDICATED ON THE <br />DRAWINGS, THE ENCLOSURE TYPE SHALL BE SUITABLE FOR THE <br />ENVIRONMENT WHERE IT IS BEING INSTALLED IN ACCORDANCE THE NEC. <br />24. VOLTAGE DROP FOR FEEDERS AND BRANCH CIRCUITS HAVE BEEN <br />INCLUDED IN THE DESIGN OF THE ELECTRICAL SYSTEM TO MEET A <br />MAXIMUM OF 5% VOLTAGE DROP PERMITTED BY 2020 FBC ENERGY <br />CONSERVATION CODE C405.5.3. <br />25. PROVIDE LABELS FOR ALL PANELBOARDS, CABINETS, SAFETY SWITCHES <br />AND MOTOR CONTROLLERS, LABELS SHALL BE MACHINE ENGRAVED, <br />LAMINATED PLASTIC, PERMANENTLY ATTACHED WITH SELF -TAPPING <br />SCREWS OR RIVETS. <br />26. PROVIDE TYPE WRITTEN PANELBOARD DIRECTORY CARD IN EACH <br />PANELBOARD WITH CIRCUIT LOAD INFORMATION AND ROOM <br />NUMBER -LOAD DESCRIPTION CLEARLY IDENTIFIED. USE ACTUAL ROOM <br />NUMBERS IN THE BUILDING WHEN DIFFER FROM ROOM NUMBERS <br />SHOWN ON THE CONTRACT DOCUMENTS. HAND WRITTEN DIRECTORIES <br />ARE NOT ACCEPTABLE. <br />27. LABEL ALL JUNCTION BOXES WITH PERMANENT MARKER IDENTIFYING <br />PANEL'S NAME AND CIRCUIT NUMBERS WITHIN. <br />28. ALL MOTORS SHALL HAVE DISCONNECTING MEANS. <br />29. WHERE FUSE PROTECTION IS SPECIFICALLY REQUIRED BY THE <br />EQUIPMENT MANUFACTURER, PROVIDE FUSED SWITCHES IN LIEU OF <br />NON -FUSED SWITCHES OR ENCLOSED CIRCUIT BREAKERS, OR OTHER <br />DEVICES INDICATED. <br />30. SECURE APPROVED SHOP DRAWINGS SHOWING WIRING DIAGRAMS, <br />ROUGH -IN AND ELECTRICAL INSTALLATION DETAILS FROM OTHER <br />INVOLVED CONTRACTORS FOR EQUIPMENT WHICH MUST BE <br />CONNECTED ELECTRICALLY. <br />31. MECHANICAL EQUIPMENT WILL BE PROVIDED BY MECHANICAL <br />CONTRACTOR. THE LOCATIONS SHOWN ON THE ELECTRICAL DRAWINGS <br />ARE APPROXIMATE. COORDINATE WITH MECHANICAL CONTRACTOR TO <br />DETERMINE THE EXACT LOCATION OF EACH PIECE OF EQUIPMENT AND <br />DETERMINE THE EXACT ROUGH -IN AND CONNECTION REQUIREMENTS. <br />32. HVAC DAMPERS AND CONTROLS. CONTRACTORS SHALL COORDINATE <br />WITH THE EQUIPMENT AND SYSTEM BEING PROVIDED AND PROVIDE <br />POWER CONNECTIONS ACCORDINGLY. THESE CONNECTIONS SHALL BE <br />FOR FIRE/SMOKE DAMPERS, DDC CONTROL DEVICES, ETC. CONTRACTOR <br />SHALL COORDINATE THE VOLTAGE REQUIREMENTS AND PROVIDE ALL <br />NECESSARY CONNECTIONS, COMPONENTS, ETC. INCLUDING <br />TRANSFORMERS, BOXES, ETC. <br />33. COORDINATE FINAL LOCATIONS OF ELECTRICAL EQUIPMENT WITH <br />MECHANICAL DUCTWORK, PIPING, ETC. AND ASSURE WORKING <br />CLEARANCE REQUIRED BY NEC WILL BE MET. SUFFICIENT ACCESS AND <br />WORKING SPACE SHALL BE PROVIDED AND MAINTAINED AROUND <br />ELECTRICAL EQUIPMENT AS REQUIRED BY NEC. <br />34. THOROUGHLY REVIEW AND COORDINATE ALL CASEWORK AND CABINETS <br />DRAWINGS AND ARCHITECTURAL ELEVATIONS WITH DEVICE LOCATIONS <br />PRIOR TO ROUGH -IN OF OUTLET BOXES. <br />35. ALL SYSTEMS SHALL BE TESTED FOR PERFORMANCE VERIFICATION IN <br />THE PRESENCE OF THE INSPECTOR, AT THE COMPLETION OF THE <br />PROJECT. ALLOW 6 HOURS FOR TRAINING OWNER'S PERSONNEL ON ALL <br />SYSTEMS. <br />36. WHERE CONDUIT CROSS BUILDING EXPANSION JOINTS, USE SUITABLE <br />SLIDING EXPANSION FITTINGS. <br />LIGHTS LEGEND <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />WALL MOUNT FIXTURE ON FLUSH 4" SQUARE J-BOX, LETTER INDICATES TYPE <br />SURFACE <br />B <br />WALLBRACKET FIXTURE ON 4"SQUARE FLUSH J-BOX, LENGTH: 2% <br />SURFACE <br />T, OR 4'- AS SHOWN ON PLANS, LETTER INDICATES TYPE <br />TROFFER FIXTURE, LETTER INDICATES TYPE <br />RECESSED <br />RECESSED DOWNLIGHT WITH TRIM AND REQUIRED CEILING ADAPTERS. LETTER <br />A <br />INDICATES TYPE. <br />A <br />E-0 <br />SURFACE MOUNT DOWNLIGHT, ROUND HOUSING, WITH TRIM AND MOUNTING <br />SEE FIXTURE SCHEDULE <br />HARDWARE. LETTER INDICATES TYPE. <br />LIGHTING CONTROLS LEGEND. <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />$ <br />SWITCH, SINGLE POLE, 20 A, 120/277 VAC. REFER TO SPECIFICATIONS FOR DEVICE <br />COLOR, WALL PLATE COLOR AND MATERIAL, AND DEVICE MODEL NUMBER. <br />48" AFF TO TOP UNLESS <br />NOTED OTHERWISE <br />$3 <br />SWITCH, THREE-WAY, 20 A, 120/277 VAC. REFER TO SPECIFICATIONS FOR DEVICE <br />COLOR, WALL PLATE COLOR AND MATERIAL, AND DEVICE MODEL NUMBER. <br />48" AFF TO TOP <br />UNLESS NOTED OTHERWISE <br />POWER LEGEND. <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />Im <br />NON -FUSED DISCONNECT SWITCH, <br />60" AFF TO TOP <br />CURRENT RATING/FUSING/NUMBER OF POLES/ENCLOSURE <br />UNLESS NOTED OTHERWISE <br />LM <br />FUSED DISCONNECT SWITCH, <br />60" AFF TO TOP <br />CURRENT RATING/FUSING/NUMBER OF POLES/ENCLOSURE <br />UNLESS NOTED OTHERWISE <br />72" AFF TO TOP <br />BRANCH CIRCUIT PANELBOARD, 120/208 V OR 120/240 V, FLUSH MOUNT <br />UNLESS NOTED OTHERWISE <br />ELECTRIC METER <br />60" AFF TO TOP <br />UNLESS NOTED OTHERWISE <br />RECEPTACLE LEGEND. <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />(P <br />DUPLEX RECEPTACLE, 20 A, 120 VAC. REFER TO SPECIFICATIONS FOR DEVICE <br />REQUIREMENTS, AND DEVICE MODEL NUMBER. <br />18" AFF TO CENTERLINE <br />COLOR, WALL PLATE <br />UNLESS NOTED OTHERWISE <br />DUPLEX RECEPTACLE, 20 A, 120 VAC. REFER TO SPECIFICATIONS FOR DEVICE <br />DEVICE <br />ABOVE COUNTER <br />UNLESS NOTED OTHERWISE <br />COLOR, WALL PLATE REQUIREMENTS, AND MODEL NUMBER. <br />DUPLEX RECEPTACLE, 20 A, 120 VAC. REFER TO SPECIFICATIONS FOR DEVICE <br />COLOR, AND DEVICE MODEL NUMBER. <br />BELOW COUNTER <br />UNLESS NOTED OTHERWISE <br />WALL PLATE REQUIREMENTS, <br />SIMPLEX RECEPTACLE, RANGE OUTLET, 50 A, 125/250 VAC, 3P, 4W, NEMA 14-50, <br />AS NOTED <br />WITH MATCHING COVER PLATE. LEVITON: 279 <br />SIMPLEX RECEPTACLE, DRYER OUTLET, 30 A, 125/250 VAC, 3P, 4W, NEMA 14-30, <br />AS NOTED <br />WITH MATCHING COVER PLATE. LEVITON: 278 <br />HOME RUN TO PANEL. LABEL INDICATES PANEL NAME AND CIRCUIT NUMBER(S). <br />SEE SPECIFICATIONS <br />rLlA-1,3 <br />ALL CONDUCTORS ARE #12 AWG Cu UNLESS NOTED OTHERWISE. <br />RACEWAY CONCEALED IN WALL OR ABOVE CEILINGS <br />SEE SPECIFICATIONS <br />RACEWAY CONCEALED UNDER FLOOR OR BELOW GRADE <br />SEE SPECIFICATIONS <br />RACEWAY EXPOSED ON WALL OR CEILING <br />SEE SPECIFICATIONS <br />SYSTEMS LEGEND. <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />v <br />COMMUNICATIONS OUTLET <br />18" AFF TO CENTERLINE <br />UNLESS NOTED OTHERWISE <br />9 <br />TELEVISION OUTLET <br />18" AFF TO CENTERLINE <br />UNLESS NOTED OTHERWISE <br />AC ABOVE COUNTER <br />AFF ABOVE FINISHED FLOOR <br />AFG ABOVE FINISHED GRADE <br />AHJ AUTHORITY HAVING JURISDICTION <br />BFG BELOW FINISHED GRADE <br />CLG CEILING MOUNTED <br />ABBREVIATIONS <br />CTE CONNECT TO EXISTING <br />EX EXISTING <br />GFI GROUND FAULT CURRENT INTERRUPTER <br />IAW IN ACCORDANCE WITH <br />IG ISOLATED GROUND <br />N NEW <br />RL RELOCATED <br />UG UNDERGROUND <br />UNO UNLESS NOTED OTHERWISE <br />WP WEATHER PROOF <br />U-) <br />00 <br />c:1 <br />cl) <br />Lo <br />cl) U-) <br />Ln <br />-i C? <br />C? <br />u- r- <br />:r <br />cli c� <br />co <br />c� <br />CL m <br />c) M 0 <br />z <br />E - <br />cc cc) <br />>, Lo U) <br />M .t co <br />�: 64 <br />E <br />0 <br />x <br />0) Cc <br />r M X <br />CD m <br />0 <br />LL. <br />1 _j LL. <br />u_ <br />c� <br />co <br />Ln <br />r,_ <br />2, u <br />.2) <br />C-4 <br />9 <br />L) C�l <br />o cc c� <br />42 <br />'a <br />>,,n <br />co <br />"t <br />0) <br />() co c) <br />4) <br />000 <br />LIU <br />C� <br />m cl) <br />0 CD C� <br />> > 'n <br />c) <br />T <br />Lu , <br />CL 00 <br />0 Lu o US <br />1- Lo - co <br />0) cm <br />CD <br />U <br />00 <br />E CN -5 <br />m C%4 <br />to w M <br />0 cf) 0 75 <br />U) Lo U) <br />INFO <br />wIt I I I <br />ce-, <br />0% STXrE OF <br />.p <br />0 <br />Abb'I PE <br />FL 73853 <br />SEAL <br />EMERALD <br />ENGINEERING INM <br />9942 CURRIE DAVIS DR. STE H., TAMPA, FL 33619 <br />TEL (813) 995-0300 FLORIDA EB*27845 <br />WWW.EMERALDMEP.COM EEI PROJECr* 210807 <br />CLIENT <br />c\l <br />It <br />Lo <br />cv) <br />cf) <br />_j <br />LL <br />cl) <br />z <br />cl a- <br />D Lu <br />N <br />z <br />< <br />0 <br />Lo <br />cf) <br />Lf) <br />It <br />00 <br />cy) <br />17 <br />PROJECT <br />@ CHANCEY DESIGN PARTNERSHIP <br />THIS DRAWING AND ALL GRAPHIC AND WRITTEN MATERIAL CONTAINED HEREIN CONSTITUTES ORIGINAL <br />AND UNPU13LISHED WORK AND IS NOT TO BE COPIED. DtSTROUTED. OR USED IN WHOLE OR IN PART. <br />WITHOUT EXPRESSED WRITTEN PERMISSION OF CHANCEY DESIGN PARTNERSW. THIS DRAWING IS <br />PROTECTED UNDER THE 'ARCHITECTURAL WORKS COF�RIGHT PROTECTION ACT OF 19W�' <br />PROJECT# 21-250 <br />PROJASSUED 8-24-2021 <br />SHEET ISSUED <br />DIESCRIP-wok <br />ELECTRICAL <br />LEGEND AND <br />SHEET TITLEGENERAL NOTES <br />E-001 <br />