c�
<br />REVAO. DESCRIFTIONS DATE
<br />REMSIONS j
<br />SEAL)
<br />) - 13--2-6 1 L
<br />ARTHUR L, ANCHORS, P.E.
<br />No. 39804
<br />SEAL)
<br />I GENERAL ELECTRICAL SYMBOLS I
<br />CONDUIT HOMERUN TO EQUIPMENT SHOWN. LINE TYPE DESIGNATES
<br />LP-3 CONCEALED, EXPOSED, ETC. NUMBERS/TEXT DESIGNATE HOMERUN
<br />EQUIPMENT (I.E. PANEL BOARD CIRCUIT NUMBER).
<br />GENERAL CONDUIT RUN CONCEALED IN FURRED WALLS AND CEILINGS,
<br />EXPOSED ELSEWHERE UNLESS OTHERWISE NOTED OR SPECIFIED.
<br />CONCEALED CONDUIT IN FLOOR SLAB, UNDERGROUND, ETC.
<br />EXISTING CABLE OR CONDUIT
<br />CONDUIT TURNED DOWN
<br />CONDUIT TURNED UP
<br />E
<br />SITE ELECTRICAL
<br />E
<br />E
<br />EXISTING SITE ELECTRICAL
<br />T
<br />SITE TELEPHONE
<br />T
<br />- - T
<br />EXISTING SITE TELEPHONE
<br />OHE
<br />OVERHEAD ELECTRICAL UTILITY
<br />OHT
<br />OVERHEAD TELEPHONE UTILITY
<br />UGE
<br />UNDERGROUND ELECTRICAL UTILITY
<br />UGT
<br />UNDERGROUND TELEPHONE UTILITY
<br />G
<br />SITE GROUND
<br />C
<br />- - G
<br />EXISTING SITE GROUND
<br />@
<br />LIMIT SWITCH
<br />FLPI
<br />LIGHTING PROTECTION
<br />0
<br />THERMOSTAT
<br />PULL BOX, SIZE PER NEC UNLESS OTHERWISE NOTED
<br />JUNCTION BOX, SIZE PER NEC UNLESS OTHERWISE NOTED
<br />ELECTRICAL EQUIPMENT CONNECTION
<br />(HARDWIRED)
<br />GROUND ROD
<br />STOP/START PUSH-BUTTON STATION
<br />19
<br />LOCAL/REMOTE OR LOCK -OUT -STOP
<br />STATION
<br />0
<br />OPERATION INDICATION PANEL LIGHT
<br />0
<br />FUSE
<br />CIRCUIT BREAKER (80% CURRENT RATED UNLESS OTHERWISE NOTED)
<br />0
<br />aMOTOR
<br />(HP=RATED HORSEPOWER)
<br />OA DISCONNECT SWITCH. TOP NUMBER DENOTES FUSE SIZE
<br />n OF 3R (NF=NON-FUSED). BOTTOM NUMBER DENOTES FRAME SIZE. RIGHT
<br />NUMBER DENOTES NEMA ENCLOSURE RATING.
<br />OA CIRCUIT BREAKER. TOP NUMBER DENOTES TRIP. BOTTOM NUMBER
<br />UOF DENOTES FRAME SIZE. RIGHT NUMBER DENOTES NEMA ENCLOSURE
<br />h 3R RATING.
<br />OA COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECT SWITCH OR
<br />OF MOTOR CIRCUIT PROTECTOR. LEFT NUMBER DENOTES NEMA STARTER
<br />2 "�7 3R SIZE. TOP NUMBER DENOTES FUSE SIZE OR MCP. BOTTOM NUMBER
<br />L_^sn DENOTES FRAME SIZE. RIGHT NUMBER DENOTES NEMA ENCLOSURE.
<br />FULL VOLTAGE NON -REVERSING MOTOR STARTER. LEFT NUMBER
<br />3 DENOTES NEMA STARTER SIZE.
<br />HREDUCED VOLTAGE SOLID-STATE MOTOR STARTER.
<br />VARIABLE FREQUENCY MOTOR CONTROLLER.
<br />a
<br />$ LIGHTING CONTROL SWITCH:
<br />4 ILOWERCASE LETTERI - CONTROL SWITCHING
<br />M - MOTOR RATED SWITCH 3 - THREE-WAY SWITCHING
<br />D - DIMMER CONTROL 4 - FOUR-WAY SWITCHING
<br />OS - OCCUPANCY SENSOR
<br />OUTLETS: NUMBER DENOTES PANEL BOARD CIRCUIT FOR POWER OUTLETS. IF SHOWN,
<br />LOWERCASE LETTER DENOTES CONTROL SWITCHING FOR POWER OUTLETS.
<br />(P SIMPLEX RECEPTACLE. VOICE (PHONE) OUTLET,
<br />(P DUPLEX RECEPTACLE, V DATA OUTLET.
<br />QUADRAPLEX RECEPTACLE. 7 VOICEIDATA COMBINATION OUTLET.
<br />LIGHTING SYMBOLS '
<br />Al a LIGHT FIXTURES (VARIOUS TYPES) - UPPERCASE LETTER DENOTES
<br />LP- 1 FIXTURE TYPE, REFER TO LIGHTING SCHEDULI� OR NOTES. NUMBER
<br />C] K DENOTES LIGHTING PANEL CIRCUIT. LOWERCASE LETTER DENOTES
<br />CONTROL SWITCH. DUAL SWITCHING INDICATED BY PAIRS OF
<br />LOWERCASE LETTERS. -NL- DENOTES NIGHT'(IGHT, CIRCUIT AHEAD
<br />OF CONTROL SWITCHES.
<br />V 4r::p EMERGENCY LIGHT - BATTERY EQUIPPED EMERGENCY LIGHT, CIRCUIT
<br />AHEAD OF CONTROL SWITCHES. ADDITIONAL FIXTURE HEADS MAY BE
<br />SHOWN CONNECTED TO UNIT. IF SHOWN, UPPERCASE LEITER
<br />DENOTES FIXTURE TYPE, REFER TO LIGHTING SCHEDULE OR NOTES.
<br />NUMBER DENOTES LIGHTING PANEL CIRCUIT.
<br />Eg PHOTOELECTRIC CONTROL DEVICE
<br />ED LIGHTING CONTACTOR
<br />A
<br />4" MCM& CREED
<br />3802 Ehrlich Road, Suite 306
<br />Tampa, Florida 33624
<br />Phone: (813)549-3740, Fax: (813)549-3744
<br />EB0006691
<br />www. m ckim creed. com
<br />TYPICAL ABBREVIATIONS
<br />A, AM P
<br />AMPERE
<br />AFD
<br />ADJUSTABLE FREQUENCY DRIVE
<br />AFG
<br />ABOVE FINISHED GRADE
<br />AIT
<br />ANALYTICAL INDICATION TRANSMITTER
<br />AHU
<br />AIR HANDLING UNIT
<br />AIC
<br />AMPERE INTERRUPTING CAPACITY
<br />AL
<br />ALUMINUM
<br />ATS
<br />AUTOMATIC TRANSFER SWITCH
<br />BKR
<br />BREAKER
<br />C
<br />CONDUIT
<br />CAB
<br />CABINET
<br />CAT
<br />CATALOG
<br />CL
<br />CHLORINE
<br />CB
<br />CIRCUIT BREAKER
<br />CCTV
<br />CLOSED CIRCUIT TELEVISION
<br />CKT
<br />CIRCUIT
<br />CLG
<br />CEILING
<br />CID
<br />CONTROL PANEL
<br />CR
<br />CONTROL RELAY, CORROSION RESISTANT
<br />CS
<br />CONTROL SWITCH
<br />Cv
<br />CONTROL VALVE
<br />CT
<br />CURRENT TRANSFORMER
<br />CU
<br />COPPER
<br />EF
<br />EXHAUST FAN
<br />EMER
<br />EMERGENCY
<br />EMT
<br />ELECTRICAL METALLIC TUBING
<br />ENCL
<br />ENCLOSURE
<br />EQUIP
<br />EQUIPMENT
<br />EWC
<br />ELECTRIC WATER COOLER
<br />EWH
<br />ELECTRIC WATER HEATER
<br />EPRF
<br />EXPLOSION PROOF
<br />FA
<br />FIRE ALARM
<br />FAAP
<br />FIRE ALARM ANNUNCIATOR PANEL
<br />FACP
<br />FIRE ALARM CONTROL PANEL
<br />FBO
<br />FURNISHED BY OTHERS
<br />FLA
<br />FULL LOAD AMPS
<br />FVNR
<br />FULL VOLTAGE NON -REVERSING STARTER
<br />FLOUR
<br />FLUORESCENT
<br />FLR
<br />FLOOR
<br />FMC
<br />FLEXIBLE METALLIC CONDUIT
<br />FWE
<br />FURNISHED WITH EQUIPMENT
<br />GEN
<br />GENERATOR
<br />G, GND
<br />GROUND
<br />GFIC
<br />GROUND FAULT CIRCUIT INTERRUPTER
<br />HH
<br />HANDHOLE
<br />HID
<br />HIGH INTENSITY DISCHARGE
<br />HOA
<br />HAND -OFF -AUTO
<br />HP
<br />HORSE POWER
<br />HPF
<br />HIGH POWER FACTOR
<br />HPS
<br />HIGH PRESSURE SODIUM
<br />HTR
<br />HEATER
<br />HV
<br />HIGH VOLTAGE
<br />Hz
<br />HERTZ
<br />IMC
<br />INTERMEDIATE METALLIC CONDUIT (GALVANIZED)
<br />INCAND
<br />INCANDESCENT
<br />JB
<br />JUNCTION BOX
<br />k
<br />THOUSAND
<br />kCMIL
<br />THOUSAND CIRCULAR MILLS
<br />kA
<br />KILOVOLT AMPERE
<br />kW
<br />KILOWATTS
<br />kWH
<br />KILOWATT-HOURS
<br />LED
<br />LIGHT -EMITTING DIODE
<br />LFMC
<br />LIQUIDTIGHT FLEXIBLE METAL CONDUIT
<br />LFNC
<br />LIQUIDTIGHT FLEXIBLE NONMETALLIC CONDUIT
<br />LIT
<br />LEVEL INDICATION TRANSMITTER
<br />LP
<br />LIGHTING PANEL, LIGHT POLE
<br />LTG
<br />LIGHTING
<br />MCB
<br />MAIN CIRCUIT BREAKER
<br />MCC
<br />MOTOR CONTROL CENTER
<br />MCP
<br />MOTOR CIRCUIT PROTECTOR
<br />MDP
<br />MAIN DISTRIBUTION PANEL
<br />MFR
<br />MANUFACTURER
<br />MH
<br />MANHOLE
<br />MLO
<br />MAIN LUGS ONLY
<br />MSB
<br />MAIN SWITCHBOARD
<br />MTD
<br />MOUNTED/MOUNTING
<br />MTS
<br />MANUAL TRANSFER SWITCH
<br />mv
<br />MEDIUM VOLTAGE
<br />NEC
<br />NATIONAL ELECTRIC CODE
<br />N, NEU
<br />NEUTRAL
<br />NA
<br />NOT APPLICABLE
<br />NC
<br />NORMALLY CLOSE
<br />NO
<br />NORMALLY OPEN
<br />NIC
<br />NOT IN CONTRACT
<br />NTS
<br />NOT TO SCALE
<br />P
<br />POLE
<br />PA
<br />PUBLIC ADDRESS
<br />PB
<br />PULL BOX, PUSH-BUTTON
<br />PCP
<br />PUMP CONTROL PANEL
<br />PF
<br />POWER FACTOR
<br />�, PH
<br />PHASE
<br />PIT
<br />PRESSURE INDICATION TRANSMITTER
<br />PLC
<br />PROGRAMMABLE LOGIC CONTROLLER
<br />PNL
<br />PANEL
<br />PID
<br />POWER PANEL, POWER POLE
<br />PT
<br />POTENTIAL TRANSFORMER
<br />PWR
<br />POWER
<br />RECEP
<br />RECEPTACLE
<br />RVSS
<br />REDUCED VOLTAGE SOFT STARTER
<br />REQ
<br />REQUIRED
<br />RM
<br />ROOM
<br />RMC
<br />RIGID METAL CONDUIT (GALVANIZED)
<br />RTU
<br />REMOTE TELEMETRY UNIT
<br />SCADA
<br />SUPERVISORY CONTROL AND DATA ACQUISITION
<br />SCR
<br />DC MOTOR DRIVE
<br />SH
<br />SHEET
<br />SPEC
<br />SPECIFICATION
<br />SS
<br />SELECTOR SWITCH
<br />SST.
<br />STAINLESS STEEL
<br />STP
<br />SHIELDED TWISTED PAIR
<br />SW
<br />SWITCH
<br />SWBD
<br />SWITCHBOARD
<br />SWGR
<br />SWITCH GEAR
<br />TEL
<br />TELEPHONE
<br />TVSS
<br />TRANSIENT VOLTAGE SURGE SUPPRESSER
<br />TYP
<br />TYPICAL
<br />UG
<br />UNDERGROUND
<br />UH
<br />UNIT HEATER
<br />LION
<br />UNLESS OTHERWISE NOTED
<br />UTIL
<br />UTILITY
<br />UTP
<br />UNSHIELDED TWISTED PAIR
<br />V
<br />VOLTS
<br />VFD
<br />VARIABLE FREQUENCY DRIVE
<br />W
<br />WIRE, WATT
<br />WH
<br />WATT-HOUR
<br />WP
<br />WEATHERPROOF
<br />XFMR
<br />TRANSFORMER
<br />CITY OF'-ZEPHYRHILLS
<br />I GENERAL NOTES I
<br />1. THE CONTRACTOR SHALL REFERENCE ALL SPECIFICATIONS AND CONTRACT DRAWINGS FOR
<br />ADDITIONAL REQUIREMENTS AND RESPONSIBILITIES PRIOR TO COMMENCING WORK.
<br />2. THE GENERAL NOTES STATED ON THIS DRAWING ARE APPLICABLE TO ALL ELECTRICAL WORK
<br />UNLESS NOTED OTHERWISE.
<br />3. THE ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT NEC, NESC AND LOCAL CODES
<br />INCLUDING OWNERS STANDARDS AND REQUIREMENTS.
<br />4. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF NECA-1 2006:
<br />(STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONSTRUCTION).
<br />5. THE SCHEDULING AND DURATION OF ANY SHUTDOWN OF ANY PLANT PROCESS FOR THE
<br />REMOVAL OF EXISTING EQUIPMENT OR INSTALLATION OF NEW EQUIPMENT SHALL BE
<br />COORDINATED IN ADVANCE WITH THE ENGINEER AND OWNER.
<br />6. ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE UTILIZED FOR THIS PROJECT.
<br />7. ADDITIONAL SYMBOLS NOT SHOWN ON THIS DRAWING MAY BE SHOWN ELSEWHERE ON THE
<br />ELECTRICAL DRAWINGS.
<br />8. ALL 480V SUPPLIED ELECTRICAL EQUIPMENT SHALL HAVE A MINIMUM RATING OF 25K AIC.
<br />9. THE ELECTRICAL DRAWINGS SHOW MAJOR CONDUIT AND CABLE REQUIREMENTS. REFERENCE
<br />ALL EQUIPMENT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
<br />10. THE CONTRACTOR SHALL PROVIDE ELECTRICAL EQUIPMENT WHICH MEETS THE SPACE
<br />REQUIREMENTS. ALL EQUIPMENT SHALL BE INSTALLED SO THAT ALL CODE -REQUIRED AND
<br />MAN U FACTURER- RECOM MENDED CLEARANCES ARE MAINTAINED. ALL INSTALLATIONS SHALL
<br />COMPLY WITH NEC 110-26.
<br />11. ALL CONDUCTOR AMPACITIES ARE BASED ON 75C RATING. THE CONTRACTOR IS RESPONSIBLE
<br />FOR INCREASING THE CONDUCTOR SIZE AS NECESSARY TO MEET THE REQUIREMENTS OF NEC
<br />110-14(C) WHERE TERMINATIONS ARE NOT LISTED AND LABELED FOR USE AT 75-C. THIS
<br />REQUIREMENT APPLIES TO TERMINATIONS IN BOTH NEW AND EXISTING EQUIPMENT TO WHICH
<br />TERMINATIONS ARE MADE AS PART OF THIS CONTRACT.
<br />12. NO SPLICES OR JUNCTIONS TO FEEDER CONDUCTORS OR CABLES SHALL BE MADE WITHOUT
<br />PRIOR APPROVAL OF THE ENGINEER.
<br />13. THE CONTRACTOR SHALL PROVIDE PERMANENT IDENTIFICATION AT BOTH ENDS OF POWER,
<br />CONTROL AND DATA WIRING PER SPECIFICATIONS.
<br />14. CONDUITS SHALL RUN PARALLEL TO LANDSCAPE, MECHANICAL OR STRUCTURAL FEATURES AND
<br />THE BENDS SHALL BE MADE BY LARGE RADIUS CONDUIT FITTINGS. MOST CONDUIT LAYOUTS
<br />ARE NOT AS SHOWN ON THE PLANS. THE CONTRACTOR SHALL PROPOSE LOGICAL GROUPINGS,
<br />MARSHALLING AND ROUTING OF CONDUITS AND WIRING FOR APPROVAL BY ENGINEER PRIOR
<br />TO INSTALLATION.
<br />15. ALL EXPOSED CONDUIT SHALL BE PVC COATED GALVANIZED STEEL CONDUIT UNLESS
<br />OTHERWISE NOTED OR SHOWN. EXPOSED CONDUIT SHALL BE INSTALLED PARALLEL TO
<br />ARCHITECTURAL AND/OR STRUCTURAL FEATURES UTILIZING CONCENTRIC BENDS AND CONDUIT
<br />FITTINGS.
<br />16. CONDUITS INSTALLED BELOW GRADE SHALL BE DIRECT BURIED DUCTBANK. DUCTBANKS SHALL
<br />CROSS PROCESS PIPING AT 90* ANGLE WHERE POSSIBLE.
<br />17. THE CONTRACTOR SHALL INSTALL CONDUITS AS REQUIRED FOR DIRECT CONNECTION TO
<br />EQUIPMENT. PROVIDE FLEXIBLE CONNECTIONS TO ALL EQUIPMENT AND IN ACCORDANCE WITH
<br />THE EQUIPMENT SPECIFICATIONS.
<br />18. THE QUANTITY AND SIZE OF WIRES AND CONDUITS ARE BASED UPON SELECTED STANDARD
<br />COMPONENTS OF ELECTRICAL EQUIPMENT. MODIFICATIONS WITH PRIOR APPROVAL BY THE
<br />ENGINEER AND WITHOUT ADDITIONAL COST TO THE CONTRACT MAY BE MADE BY THE
<br />CONTRACTOR TO ACCOMMODATE ELECTRICAL EQUIPMENT.
<br />19. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS REQUIRED FOR MAKING FINAL
<br />CONNECTION OF ALL EQUIPMENT INSTALLED OR MODIFIED AS PART OF THIS CONTRACT.
<br />20. THE CONTRACTOR SHALL PROVIDE ALL PULL BOXES, TERMINAL BOXES AND JUNCTION BOXES
<br />AS REQUIRED FOR THE INSTALLATION OF WIRING IN ACCORDANCE WITH THE CONTRACT
<br />SPECIFICATIONS THOUGH BOXES MAY NOT BE INDICATED ON THE DRAWINGS.
<br />21. CONDUIT AND WIRING FOR LIGHTING, RECEPTACLES AND OTHER SINGLE PHASE POWERED
<br />DEVICES ARE GENERALLY NOT SHOWN BUT SHALL BE PROVIDED AS REQUIRED FOR
<br />CONTRACTUAL COMPLIANCE. MULTI -PHASE CIRCUITS SHALL BE PROVIDED WITH DEDICATED
<br />NEUTRAL CONDUCTOR.
<br />22. THE CONTRACTOR SHALL VERIFY AND CONFIRM THE LOCATION OF ALL MOISTURE AND
<br />HAZARDOUS AREA CONDUIT SEALS.
<br />23. ALL SPARE CONDUITS SHALL BE CAPPED AND SHALL INCLUDE 200# TEST POLYPROPYLENE
<br />PULL STRING.
<br />24. STRUT -CHANNEL SHALL NOT BE BENT, DRILLED, CUT OR OTHERWISE MODIFIED TO PRODUCE
<br />FITTINGS, BRACES OR BRACKETS FOR CONDUIT AND EQUIPMENT SUPPORTS.
<br />25. MANUFACTURED STRUT -CHANNEL BRACES, BRACKETS, FITTINGS OR POST BASES SHALL BE
<br />PROVIDED AND INSTALLED WITH ASSOCIATED HARDWARE AND FASTENERS FOR CONDUIT AND
<br />EQUIPMENT SUPPORTS.
<br />26. THE CONTRACTOR SHALL PROVIDE AND INSTALL CONCRETE EMBEDDED LEVELING CHANNEL
<br />SUPPORTS FOR FLOOR MOUNTED EQUIPMENT INCLUDING AUXILIARY SUPPORTS FOR
<br />SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, CONTROL PANELS, ETC., AS REQUIRED.
<br />27. STRUCTURAL MEMBERS SHALL NOT BE DRILLED, CUT, WELDED OR OTHERWISE MODIFIED
<br />WITHOUT PRIOR APPROVAL OF THE ENGINEER OF RECORD.
<br />28. ALL RECEPTACLES SHALL BE GROUND FAULT CURRENT INTERRUPTING (GFCI) RECEPTACLES:
<br />A. SHALL BE RATED FOR 20A AT 120V WITH LED POWER INDICATOR
<br />B. INSTALLED OUTDOORS OR IN PROCESS AREAS, ALL RECEPTACLES SHALL BE
<br />WEATHER PROOF, CORROSION RESISTANT, AND SHALL BE INDIVIDUAL GFCI
<br />DEVICES.
<br />TYPICAL DEVICE MOUNTING HEIGHTS
<br />RECEPTACLES (INTERIOR PROCESS AREAS)
<br />RECEPTACLES (EXTERIOR PROCESS AREAS)
<br />LIGHT SWITCHES
<br />NOTE: DIMENSIONS ARE TO DEVICE TOP UNLESS NOTED OTHERWISE.
<br />PRODUCTION WELLS
<br />No. 11 AND No. 12
<br />WELL SITE IMPROVEMENTS
<br />GENERAL NOTES, SYMBOLS
<br />AND LEGENDS
<br />F,
<br />DATE:
<br />_1qN
<br />FEBRUARY 2012
<br />IVICE PROJ.
<br /># 4584-0003
<br />DRAWN
<br />BMW
<br />DESIGNED
<br />BMW
<br />CHECKED
<br />ALA
<br />PROJ. IVIGR.
<br />MSL
<br />SCALE
<br />HORIZONTAL:
<br />NA
<br />VERTICAL:
<br />NA
<br />24" AFF
<br />48" AFF
<br />48" AFF
<br />C NUM
<br />El
<br />STATUS: RPOSION
<br />ISSUE FOR BID