Laserfiche WebLink
EQUIPMENT SCHEDULE <br />UNITS <br />TONS <br />MIN, REQ'D CAP <br />C;OND.ENT.EVAf= <br />C;,F,M. <br />BEER <br />MANUFACTURER <br />MODEL NUMBER <br />TOT.MBH <br />HTG, KW <br />DB OF <br />1115 OF <br />1-5 <br />r;"O <br />5-1.0 <br />10 <br />50 <br />lo-1 <br />Ic300 <br />14.0 <br />CARRIER OR EQV. <br />CH14N5OroO1FX4DNFOroIL <br />r0--1 <br />4,o <br />46.0 <br />10 <br />50 <br />ro-1 <br />1533 <br />14,0 <br />CARf;RIER OR EQV. <br />CH14N5O4&/FV4GNOOro <br />AIR BALANCE SCHEDULE <br />AHU I <br />OUTSIDE AIR INTAKE C;FM <br />+151 <br />SUFFILY AIR CFM <br />+11300 <br />RETURN AIR-C:FM <br />-1143 <br />TOTAL BUILDING FREBSURE <br />11011 cf=m <br />AHU 2 <br />OUTSIDE AIR INTAKE C:FM <br />+352 <br />SUPPLY AIR CFM <br />+11300 <br />RETURN AIR C:FM <br />-1510 <br />EXHAUST C:FM <br />-200 <br />TOTAL BUILDING FRE55URE <br />11011 GFM <br />AHU 3 <br />OUT51DE AIR INTAKE C:FM <br />+211 <br />6UPPLY AIR C:FM <br />+11300 <br />RETURN AIR C:FM <br />-IrOBC3 <br />TOTAL BUILDING PRESSURE <br />11011 GFM <br />AHU 4 <br />OUTSIDE AIR INTAKE C:FM <br />+102 <br />SUPPLY AIR CFM <br />+11300 <br />RETURN AIR CFM <br />-Mie <br />TOTAL BUILDING PRESSURE <br />11011 cf:m <br />A14U 5 <br />OUTSIDE AIR INTAKE CFM <br />+162 <br />SUPPLY AIR C:FM <br />+11300 <br />RETURN AIR C-FM <br />-1-1315 <br />TOTAL BUILDING PRESSURE <br />11011 cf:m <br />AHU ro <br />OUTSIDE AIR INTAKE C:FM <br />+3roa <br />6UPPLY AIR CFM <br />+1533 <br />RETURN AIR CFM <br />-11(05 <br />EXHAUST C:FM <br />-150 <br />TOTAL BUILDING PRESSURE <br />11011 CFM <br />AHU 7 <br />OUTSIDE AIR INTAKE C-F-M <br />+208 <br />6UPPLY AIR CFM <br />+1533 <br />RETURN AIR CFM <br />-1325 <br />TOTAL BUILDING PRESSURE <br />11011 CFM <br />FAN SCHEDULE <br />FAN* <br />MFG/MODEL <br />TYPE <br />C:FM <br />VOLTS <br />AHU <br />2 <br />EF-1(4) <br />NUTONE / QT50 or Eqv. <br />CEILING EXH. <br />I E0 <br />120 <br />ro <br />EF-1(3) <br />NUTONE / QT50 or Eqv. <br />CEILING EXH, <br />50 <br />120 <br />OUTSIDE AIR CALCULATION <br />AHU <br />MFG AREA <br />SQ. FT. AREA <br />CFM/F`RSN + CFM/FT 2 <br />MIN, <br />O'A. CIPM <br />1 <br />2612 <br />0,0 X ro + O(o X 2612 <br />151 <br />AHU <br />MFC-4 AREA <br />5Q, FT, AREA <br />CPM/FR8N + CFM/FT 2 <br />MIN, <br />O,A, CFM <br />3030 <br />0,0 X ro +'Oro X 3030 <br />182 <br />—2 <br />AHU <br />MFC:S AREA <br />5Q. FT. AREA <br />CFM/FRSN + CFM/FT 2 <br />MIN, <br />O,A, CFM <br />3510 <br />0,0 X ro + 'Oro X 3510 <br />211 <br />—3 <br />AHU <br />MFG AREA <br />5Q. FT. AREA <br />CFM/F'RSN + CFM/FT 2 <br />MI <br />O,A, CFM <br />4 <br />3030 <br />0'0 X (0 + '0(0 X 3030 <br />182 <br />AHU <br />MFG AREA <br />6Q. FT. AREA <br />C:FM/FRSN + CFM/FT 2 <br />MIN, <br />O'A' CFM <br />5 <br />2100 <br />0,0 X ro + 06 X 2100 <br />162 <br />AHU <br />OFFICE AREA <br />SQ, FT, AREA <br />CFM/F`RSN + CF-M/FT 2 <br />MIN, <br />O,A. CFM <br />ro <br />3110 <br />5,0 X 13 +'Oro X 3110 <br />210 <br />AHU <br />OFFICE AREA <br />SQ, FT. AREA <br />C:FM/FR5N + CFM/FT 2 <br />MIN, <br />O,A. CFM <br />1 <br />24ro& <br />5.0 X 12 + 06 X 2465 <br />200 <br />MECHANICAL GENERAL NOTES <br />1. DUCT SHALL BE SECURELY SUPPORTED, HUNG OR SUSPENDED IN ACCORDANCE WITH THE LATEST SMACNA EDITION AND <br />FLORIDA BUILDING CODE MECHANICAL CODE 2014. <br />2, PROVIDE ALL MECHANICAL EQUIPMENT WITH MANUFACTURER'S RECOMMENDED SERVICE AREA CLEARANCES. <br />3, IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC: ONLY AND SHOULD NOT BE SCALED. <br />4, AIR DEVICE LOCATIONS MAY BE ADJUSTED IN COORDINATION WITH LIGHT FIXTURES. <br />5, DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. DUCTWORK DIFFUSERS REGISTERS, GRILLES AND <br />OTHER ITEMS OF T14E AIR HANDLING SYSTEM SHALL NOT BE SUPPORTED BY THE CEILING OR COILING SUSPENSION SYSTEM. <br />(o, PROVIDE A TRAP IN ALL CONDENSATE PIPING LOCATED AT AIR HANDLING UNITS. SLOPE CONDENSATE LINES 1/&" PER FOOT, <br />CONDENSATE LINES SHALL BE PVC 5CH 40. ALL CONDENSATE DRAIN TRAP DETAIL. <br />1, ALL MECHANICAL WORK SHALL MEET ALL THE REQUIREMENTS OF THE 2014"FLORIDA BUILDING CODE MECHANICAL <br />MECHANICAL NOTES: <br />1, PROVIDE MANUAL DAMPER AT ALL BRANCH CONNECTIONS, SEE DETAIL, <br />2. ALL MECHANICAL WORKS AND INSTALLATIONS SHALL COMPLY WITH FLORIDA MECHANICAL CODE, ASHRAE AND SMACNA STANDARDS <br />3, COORDINATE DIFFUSERS AND GRILLE LOCATIONS WITH OTHER TRADES. <br />4, ALL FLEX FIBERGLASS INSULATION R-6, INSTALL PER LATEST SMACNA STANDARDS. <br />5. OUT61DE AIR INTAKES EXISTINGI CONFIRM ARE MIN, 10 FEET FROM ANY EXHAUST OR PLUMBING VENTS. <br />(o, COORDINATE ALL MECHANICAL WORK INCLUDING EQUIPMENT DUCT WORK OR PIPING WITH ARCHITECT AND OTHER TRADES PRIOR TO WORK. <br />1, ALL INSULATION, MATERIAL, COVERINGS, ADHESIVES, VAPOR BARRIERS NOT TO EXCEED 25 AND SMOKE DEVELOPMENT NOT TO EXCEED 50 <br />5. DUCT TAPES SHALL CONFORM TO NFPA c3OA, FLAME5FREAD CLASSIFICATION. <br />S. EXHAUST DUCTS MUST TERMINATE IO'HORIZONTALLY FROM OR 3'ABOVE ALL AIR INTAKES. <br />10, T-STAT LOCATION(S) TO BE DETERMINED BY INSTALLING HVAC CONTRACTOR. <br />11. CONTRACTOR TEST AND BALANCE AIR DISTRIBUTION CFM AS LISTED. <br />HVAC <br />6FECIFICATIONS: <br />EXHAUST FANS: <br />FURNISH EXHAUST FAN WITH PERFORMANCE AND CAPACITIES AS LISTEI-D ON THE DESIGN DRAWINGS, <br />AIR DISTRIBUTION EQUIPMENT. FURNISH SUPPLY AIR DIFFUSERS AND RETURN AIR REGISTER WITH MANUAL BALANCING DAMPERS <br />DUCTWORK: PROVIDE AND INSTALL AIR DISTRIBUTION SYSTEM AS INDICATED IN DESIGN DRAWINGS. <br />ALL PLENUM RIGID SUPPLY AIR AND RETURN AIR DUCTWORK SHAH BE D54xlOxl/2-8O0 DUCTWORK EXTERNALLY <br />WRAPPED WITH 2" THCK R-ro FIBROUS GLASS DUCT WRAP WITH AND FSX VAPOR BARRIER. ALL FLEXIBLE SUPPLY <br />AIR AND RETURN AIR DUCTWORK SHALL BE CONSTRUCTED TO R-ro REQUIREMENTS. ALL EXHAUST AIR DUCTWORK SHALL BE FLEXIBLE <br />ALUMNIZED DUCT. ALL OUTDOOR AIR DUCTWORK SHALL BE GALV STEEL SNAPLOCK. ALL DUCT AND INSULATION JOINTS SHALL BE WITH <br />GLASS FAB AND APPROVED MASTIC FABRICATED AND SUPPORT ALL DUCTWORK IN ACCORDANCE WITH SMACNA. DUCT DIMENSIONS <br />REFERENCED ARE CLEAR INSIDE DIMENSIONS. FLEXIBLE DUCT 15 THE SAME AS THE NECK SIZE. <br />APPLY 2" THICK 0,15 FOUND DENSITY F15ERGLASS INSULATION WITHAN FSX VAPOR BARRIER AND GLASS FA5 AND MASTIC TO THE <br />TOPS OF ALL SUPPLY AIR DIFFUSER AND REGISTERS. <br />ALL DUCT BRACES SHALL BE EQUIPPED WITH MANUAL VOLUME DAMPERS WITH THE REGULATORS ACCESSIBLE. <br />CONDENSATE PIPING - ALL CONDENSATE PIPING SHALL BE WHITE SCHEDULE 40 PVC ALL HORIZONTAL PIPE SHAH <br />BE INSULATED WITH SOLVENT WELDED OR THREADED FITTINGS. <br />SPRING 4 NEOPRENE <br />TYPE VIBRATION <br />ISOLATORS <br />TYP, 3/8" HANGING <br />ROD'6 (THREADED) <br />COORDINATE W1 <br />STRUCTURAL ENGINEER <br />AND OR ARCH, ON <br />HOW TO FASTEN <br />TO STRUCTURE <br />MOUNTING CLIPS OR <br />UNITS CONNECTION TO <br />5UPPORT RODS AS <br />RECOMMENDED BY MFG, <br />ELECTRIC: HEAT <br />ASSEMBLY <br />FLEXIBLE DUCT <br />CONNECTOR <br />SUPPLY <br />AIR DUCT <br />TRANSITION AS REQUIRED <br />PzRoviDE 24" SERVICE <br />CLEARANCE FOR ALL <br />ACCESS PANELS <br />A,H,U, HANGING DETAIL <br />N.T.8, AHU-CH <br />TRANSITION AS REQ'D, <br />RETURN AIR DUCTWORK <br />OUTSIDE AIR DUCT W1 <br />OPPOSED BLADE DAMPER <br />FILTER 4 RACK ASSEMBLY <br />2" DEEP GALV, DRAIN PAN 2" <br />LARGER THAN UNIT ON ALL 4 <br />SIDES. STRAPPED TO A,H.U. <br />CONDESATE DRAIN AND TRAP <br />REFRIGERANT LINES TO <br />CONDENSING UNITS <br />INSULATE SUCTION LINE) <br />AUX, DRAIN <br />TURNING VANES, <br />(TYPICAL) <br />RUSKIN OR---/ <br />EQUIVALENT <br />180' OR 90* SUPPLY THROUGH <br />THROUGH ROOF <br />LOOR OR WALL, W/TURNING <br />OA INTAKE GRILL <br />VANES, <br />W/SITE <br />(TYPICAL) <br />F1 Qr-, <br />FABRICATED <br />-FLEXIBLE <br />CONNECTION <br />CONNECTOR, <br />(T <br />1 YPICAL) <br />METAL WALL CAP <br />W/ BACKDRAFT DAMPER <br />AND BIRD SCREEN <br />L-j <br />-j <br />FLASHING ANDJ <br />SEAL WALL CAP fy- <br />0 <br />r w <br />W <br />l`-- <br />x <br />W <br />12 ga. HANGER WIRE <br />ME L SUPPO T <br />STRAP MIN. 1\" WIDE <br />-- BACK DRAFT <br />DAMPER <br />FAN <br />HOUSING <br />WALL z <br />OPENING CEILING <br />/RRFEMOVABLE GRILL <br />EXHAUST FAN DETAIL <br />IN SUSPENDED CEILING <br />SCALE: N.T.S. <br />U <br />CV) <br />C%j <br />Lf) <br />ce) <br />Cl) <br />C) <br />C� <br />0 [,- <br />J to <br />U- L9 <br />C14 <br />L0 <br />C") <br />L) <br />W <br />Cl) C) <br />C� <br />Cr) <br />C%4 <br />L0 <br />co C� <br />L0 <br />W <br />0 <br />LL <br />x LL <br />0 <br />C14 <br />cc) <br />CV) <br />>- <br />N <br />W> <br />LLI <br />U) <br />ir- <br />U) <br />LU <br />Z <br />< LL N <br />LU <br />2,6P) <br />U.) C20 <br />z <br />wo <br />0 <br />LO <br />z C14 <br />C6 <br />W <br />LU <br />z <br />It <br />(0 <br />M <br />C) 04 <br />> <br />z <br />W <br />LU <br />LO <br />b <br />z <br />I <br /><U) <br />z <br />W <br />z <br />U) <br />D <br />co <br />z <br />0 <br />Lij <br />z <br />Of <br />cl) <br />Lu <br />LL <br />LU <br />LU <br />!Z- <br />(0 <br />04 <br />L0 <br />0 <br />(D <br />z <br />Cl) <br />C0 <br />Z <br />—j 00 <br />co <br />X 0 <br />0 L'j <br />M 0 04 <br />0 < U') <br />UNIT CONDENSATE DRAIN <br />PAN: INCLUDES FLOAT <br />0 CD SWITCH WIRED FOR UNIT <br />0 0 HUT DOWN, PROVIDE CLEAN <br />U HUT DOW N P' <br />0 <br />0 OUT, TO CONDENSATE WELL <br />OUT ' To CO D <br />STEEL FRAME W/G90 <br />STEEL FRAME <br />< 0 SHEET METAL AND 1 - EXTERIOR 5UILGING WALL <br />SHEET METAL '4 <br />E— ---� INTERIOR I" PVC CONDENSATE PIPE <br />_I <br />121NSULATED <br />INSULATED <br />di <br />0 <br />z <br />0 <br />2 <br />OPTIONAL > PLENUM FRAME W FROM A.P.U., VERTICAL PIPE <br />PLENUM <br />CO <br />— — — — SUPPORTED MIN. 10'-0" O.C. <br />LOCATION x <br />> <br />i n <br />LU <br />0 FLOOR JOIST, SEE I I <br />12 <br />FLOOR JOIST, SEE FRAMING FOR SPECIFIC MIN. <br />FRAMING FOR SPECIFIC ------------ LOCATION, UNIT IS <br />L7 <br />LOCATION, UNIT IS LOCATED UPSTAIRS ON <br />7 TURNED EL50W <br />LOCATED UPSTAIRS ON MEZZANINE FINISH FLOOR rA5OvE GRADE <br />MEZZANINE <br />SUPPLY OR RETURN THROUGH FLOOR, <br />TURNING VANES, RETURN SPECIFIC TYPE INSTALLATION, <br />WITH DIVIDER DAMPER GRADE AT <br />5UILr <br />CONSULT WITH FRAMING LANSCAPS <br />(LOCATION MAY VARY) CONTRACTOR FOR REQUIRED FRAMED FOUNDATION <br />OPENINGS THROUGH BEARING WALL <br />TO ACCOMADATE DUCT WORK CONDENSATE DISF'OSAL <br />(TYPICAL SECTION, UPFLOW UNIT ON STAND) AT EXTERIOR GRADE <br />VERTICAL AHU DETAIL: ON FLOOR OR MEZZANINE SCALE: N.T.S. <br />U) CV) <br />N.T.S. <br />L6 <br />M L6 <br />z C) C; <br />Lii z <br />< 0 <br />Provide 4" pvc sleeve at <br />pennetration and seal ends <br />watertight <br />Refrigerant lines metal <br />straps secured to <br />Building wall <br />Install as )Der F5CM <br />Secure condensing unit to Protective metal jacket <br />concrete pad with I" wide paint to match Arch. <br />cIalvanized shestmetal straps Condensing unit -N <br />min. 22 gauge, *10 screws <br />3/4" lone with gasketed <br />washers/ TaL--pm 114" x 1 <br />1/2" , <br />For units between 24" and <br />36", three screws shall be <br />used per side. <br />I <br />\�Neoprene vibration isolators - optional <br />4" concrete housekeeping pad <br />C,ondensing Unit 'Mounting [)Stail <br />N,T,S. <br />(2) 2X6 F.T. BOLTED TO TOP <br />OF- BRACKET WITH (2) 1/4",<2" rrPICAL UNIT WITH (1) 1/4"Xf" <br />BOLTS AT EACH END LAG BOLT MOM BASE OF UNIT <br />INTO 2Xro P,T. BELOW AT <br />EACH COR14ER <br />RU55ER VIBRATION PAD <br />RP 3/4' - 2'W <br />RP 3/8" - 2"X2" <br />ALL BRACKETS TO BE 3/I6'X3"X3" <br />ALUMINUM C14ANNEL MAIERIAL WELOW --------- ------------- SECURE BRACKETS TO BLOCK <br />1\ EXPANSION BOLTS OR TO WOOD <br />AT ALL JOINTS WALL WITH (2) /2"X4" REDHEAD <br />0 <br />0 <br />WALL WITH (2) 1/2"x3l' LArs BOLTS <br />-.4- <br />ALUMINUM WALL MOUNT CONDENSER UNIT BRACKET <br />NOT TO SCALE <br />W <br />0 <br />LL <br />0 <br />TYPICAL SPIN -IN FITTING W/DAMPER LL Z <br />DRAW BAND FOR INTERIOR LINER <br />SUPPORTS 5 ft. MAX. DISTANCE co <br />2 In. WIDE MIN, z W <br />TYPICAL DIFFUSER <br />EXTERIOR LINER, SEAL AND FASTEN TO DUCT TRUNK W <br />AS PER 2014 FLORIDA MECHANICAL CODE SECTION roO3 a — <br />DUCT TRUNK 0 <br />TYPICAL FLEX DUCT INSTALLATION LL <br />NO SCALE 0 <br />z W <br />W <br />W <br />Z <br />W <br />U) <br />0 <br />a. <br />0 <br />VAAN,90 <br />0 <br />"P <br />AU77 <br />M <br />% <br />10 F10r.' M 2 <br />FL 33526 <br />T 1L., 38654 <br />P 0. B /1/742 <br />111111111111"W" <br />