Laserfiche WebLink
8 7 1 6 <br />NOTES "FAT" TRACK TYPE SHOWN BELOW <br />NOTES' 13 CA ROLLER SLIDE ATTACHED TO <br />1. IMPACT RESISTANT GLAZING OPTION- IMPACT 13 GA HORIZ ANGLE BRACKET NTH 5/16-18 BOLT & NUT <br />RESISTANT GLAZING SYSTEM MAY BE INSTALLED <br />IN TOP OR INTERMEDIATE SECTION (WITH OR IN CENTER SLOT AND 1/4-20xg/16* <br />WITHOUT DECORATIVE INSERTS). GLAZING SHALL TRACK BOLT & 1/4-20 HEX NUT <br />THROUGH ANY TWO ALIGNING HOLES--�_) <br />13E 1/4' POLYCARBONATE. MAXIMUM GLAZING 13 CA FLAG ANGLE <br />DIMENSIONS SHALL BE 12.41" x 18.53' CUTOUT, 13 CA COMMERCIAL 'A' FRAME <br />FASTENED WTH #8 X 1- SMS: 3X ALONG THE 16 CA MIN HORIZ TOP 13RACKET ATTACHED WITH <br />D HORIZONTAL AND 2X ALONG THE VERTICAL. SEE TRACK (5) 1/4-14x7/8' SELF <br />DETAIL A ON SHEET 2 FOR ASSEMBLY DETAILS. DRILLING CRIMPTITE SCREWS� <br />2. NON -IMPACT REISTANT GLAZING OPTION - 5/16xl-5/8" <br />-090" MINIMUM SS9 GLAZING IN MOLDED FRAMES LAG SCREW (MIN 4 <br />SCREWED TOGETHER WITH A MINIMUM OF (10) AS SHOWN) <br />#8xl" SCREWS INSTALLED IN TOP OR (4) 1 /4-20x9/16" LARGE ADD (2) 1/4-14�7/8" <br />INTERMEDIATE SECTION (WITH OR WTHOUT HEAD TRACK BOLTS OR SELF DRILLING CRIMPTITE SCREWS <br />DECORATIVE INSERTS) MEETS UNIFORM STATIC 1/4-20 STUDS WITH (INSIDE OF EACH END HINGE) IS CA END STILE <br />WIND PRESSURES SHOWN ON THIS DRAWING. 1/4-20 HEX NUTS <br />1 2" NYLON WINDLOAD ROLLER <br />GLAZING SHALL HAVE A MAXIMUM HEIGHT OF 5 CA MIN VERT S;TFM <br />10-69" AND A MAXIMUM LENGTH OF 16-94'. TRACK <br />GLAZING IS NOT IMPACT RESISTANT AND DOES NTH 4-1/2" STEM <br />NOT MEET THE REQUIREMENTS FOR WIND-BORNE <br />DEBRIS REGIONS. 1/4-20xg/16" TRACK <br />BOLT AND 1/4-ZU HEX <br />� 1— 1. ­11 1— ­­ — Al -- <br />A I <br />MAXIMUM OF 6" O,C. MUST OVERLAP TOP AND JAMB BRACKET LOCATION <br />BOTH ENDS OF PANELS MINIMUM 7/16- TO MEET -J 14 CA WIDE BODY END <br />NEGATIVE PRESSURES- 'HINGE ATTACHED NTH <br />5/16 1 5/8" LAG <br />(4) 1/4-14x5/8" SELF <br />Si "& AT EACH TAPPING SCRE <br />4. KEY LOCK, SLIDE LOCK, OR OPERATOR ORE <br />REQUIRED, JAMB BRACKET <br />5� LOUVER OPTION - .040" MINIMUM LOUVERS IN <br />MOLDED FRAMES SCREWED TOGETHER NTH A <br />MINIMVIV OF (10) #Bxl" SCREWS INSTALLED IN <br />THE BOTTOM SECTION, LOUVERS ARE NOT IMPACT <br />REQUIREMENTS FOR WIND-BORNE ULt3HIS 15 CA STIFFENED-/ <br />RESISTANT AND DO NOT MEET THE <br />ODY <br />REGIONS. JAMB BRACKETS 18 GA NARROW BODY <br />SEE SCHELDULE FOR INTERMEDIATE HIN GE <br />OUANITY, LOCATION, ATTACHED NTH (4) <br />6. SECTION STEEL TO HAVE A MINIMUM 26 GA 1/4-14x5/8- SELF <br />THICKNESS. AND TYPE TAPPING SCREWS <br />7 THE DESIGN OF THE SUPPORTING STRUCTURAL KEY LOCK OR SLIDE-/-/ <br />ELEMENTS SHALL BE THE RESPONSIBILITY OF THE LOCK ONE END (NOT <br />PROFESSIONAL OF RECORD FOR THE BUILDING OR REQUIRED WITH 14 GA BOTTOM BRACKET <br />STRUCTURE AND IN ACCORDANCE WITH CURRENT OPERATOR - SEE ATTACHED WITH (2) <br />P" <br />BUILDING CODES FOR THE LOADS LISTED ON THIS NOTE 4). SLIDE LOCK 1/4-14x7/8" SELF DRILLING <br />DRAWING. SHOWN FOR CLARITY CRIMPTITE SCRM AND (1) <br />1/4-144/8" SELF DRILLING <br />8 DOOR JAMB TO BE MINIMUM 2x5 STRUCTURAL TAMPER RESISTANT SORE <br />GRADE LUMBER. REFER TO JAMB CONNECTION <br />SUPPLEMENT FOR ATTACHMENT TO SUPPORTING NOTE, (4) SECTION SOLID <br />S <br />TRUCTURE. DOOR SHOWN, SEE SHEET <br />2 FOR U-BAR LOCATIONS <br />9. FOR LOW HEAD ROOM LIFT CONDITIONS, TOP ON DOORS NTH OTHER <br />13RACKET SHALL BE A 13 CA LHR 7/4 TOP SECTION QUANTITIES AND <br />BRACKET WTH A MINIMUM OF (3) 1/4-140/8" SEE NOTES 1 AND 2 THIS <br />SELF DRILLING CRIMP71TE SCREWS IN JEU OF THE SHEET FOR GLA21NG <br />BRACKET SHOWN ON THIS DRAWING. U-SAR ON OPTIONS. <br />TOP SECT10N SHALL BE INSTALLED ON TOP OF <br />LHR TOP BRACKETS. <br />10, IN LIEU OF THE SHORT PANEL FMBCSSMENT JAMB BRACKET SCHEDULE <br />SHOWN, LONG PANNEL EMBOSSMENT. V12 PANNEL OF JAMB LOCATION OF CENILHUNE U <br />EMBOSSEMENT OR NO EMBOSSMENT MAY BE DOOR NO OF BRACKETS BRACKETS MEASURED FROM <br />USED. HEIGHT SECTIONS (EACH JAMB) OF TRACK (ALL DIMENSIONS <br />FAT-7 2' (JI3-US), 17 (J9-US), 21-3/4" (JE3-US), 29-3/4' (JB-US), 39" (JB-US), <br />14 CA MIN <br />HEADPLATE <br />16 CA HORIZONTAL <br />TRACK <br />ri <br />LAG <br />SCREW <br />15 CA MIN <br />AT EACH <br />JAMB <br />BRACKET <br />"NGR` TRACK <br />TRANSITION ELLIPSE <br />16 CA MIN VERT <br />TRACK <br />12 CA JAMB <br />3RACKETS SEE <br />SCHEDULE FOR <br />QUANTITY, <br />LOCATION AND <br />TYPE <br />TYPE <br />7 <br />3 <br />20 GA CENTER STILE COR I <br />F JAMB <br />BOTTOM <br />± 2") <br />4 <br />443" (JE-US), 57-1/4" (JB-US) <br />6_6 <br />NGR-6 <br />5" (STD), 22" (STO), 35 3/4" (STD), 54-3L4- (STD), 67- (Sri)), 73- (STE) <br />FAT-7 <br />2- (JB-US), 10- (JB-US), 21-3/4" (JB-US), 29-3/4- (J3-US), 42- (JI3-US), 52-1/2" (J8-US), 63-1/4- (JB-US) <br />7'-0' <br />4 <br />NGR-6 <br />. <br />5 STD , 22 ($TD). 35 3 4 STD). 54-3 4 (STD . 67 STD 73 STD) <br />FAT-8 <br />10- (JB-US). 18-3/4" (,B-US�, 26-341" 013 - USL6245' <br />2, U <br />JJIB-US). 54-1/4- (JB-US), 74-1/2- (��US <br />7'-6" <br />5 <br />NGR -7 <br />�S�BjUS), <br />(t;IU2. 6t) J/,q (t510). t�4-444 <br />:> (tjlv�. til FS% 3 TD�l <br />F&Tm��2 <br />10 �J8-US), 21-5/4 (JU-US), 29-J44 �Jhf-Ut,�, 5�1 (JH-Ub), 4,b <br />�JH-US), 57-1/2- (JB-U <br />NGR-7 <br />M-L15), <br />1 5 STD), 22 (STD), 35 3/4' (STD), 54-5/4- (STD). 67" (STD), 73- (STD), 82- (STD) <br />8 _0 <br />SEE NOTE BELOW <br />2 <br />STATIC PRESSURE RATI.\GS <br />APPROVED SIZES <br />DESIGN PRESSURE(PSF): 46/-52 <br />MAX W0 H: 9' <br />��A 14' <br />INIPACT/CY--LIC RATED YES <br />_�_IIEIGHT: <br />.: 21 <br />�MAX SECTION HEIGHT <br />III <br />I <br />I Z <br />1 2 <br />1 t <br />7 S I'N <br />o /�Z/ L L <br />DNOrl 'A <br />. �w <br />�INON <br />38ASV3vi <br />AD iiNn I <br />.9 :S%W <br />oto T <br />�13 . T Xx <br />I T -, <br />31111�11N <br />rLLL, _ <br />9L/L T <br />'SAW <br />3W SM <br />ss� <br />1,t _G <br />0 1 /gZ/O I. <br />MYS <br />Nol �� .'N <br />SNOILDVHA <br />L9Z, <br />-/"Do + L�6p-O Nn <br />301M XVN 6 '6SM <br />IM09L 'OL� SM]IS <br />OL/gL/ot <br />80-1XVi <br />4,AAN%,jSV <br />V/N <br />.)a _ <br />-1 <br />1. � "I I .1�1­ �' I ­. <br />HSINIA <br />'NOLLMOcI803 SOOD CrV]1463�0 AO iN39NOD WILLIHM OU103dS 3HI ifiGH1,1M <br />.40 3MISGI)�IO ON HOUV�JOISOD LIODU JU14040 A0443�1,100 141-11SM <br />3somm MV 60J U 3SA 01 NOINZISDAIN SO :IS9on v sy im3do 01 OIGN]UNI SI NOILVV480ANI <br />NOISd M InOHIA 2NOMV 0.1. C125013SIC 60 S3NNVA ANY NI 031dO3 32 ION AIM 'J.�Vd NI aQ 3 <br />ONVAVUO SJH� 'S31NY.IN03 Q31VnJAV S.0 (INV I4CI1VaOddOD ?JOO(I <br />OU083AC AD Ald3dOdd A6VI31WOUJI GNV _WUf00IJNW 3HI 3iJV 1,113831-1 03NIVJNOD NOLLVIN60JINI U3H <br />, siNna NoLionaisNoD avoi aNiA jo Nouvouldm <br />V <br />dOJ ATNO 03CIA08d IV3S S,031,1101,13 -WNOISS3AOdd <br />1.6Z901. 3d Xi <br />L909L X1 '3-T11ASIM31 <br />OOZ 311ns LzL mH 3ivis *s Los�7 <br />:3� (Aolffivs V "ViN <br />C 9 � <br />13 0 <br />NOTE <br />(J9 AND NrR) FOLLOWING DIMENSION DENOTES SLOTTED JAMB 8RAGKET ATTACHED TO TRACK NTH 1/4-20�9/15" TRACK BOLT AND NUT AS SHOWN ABOVE. <br />MARK A. SAWICKI, PE <br />ALL DOORS GREATER THAN 8' IN HEIGHT REQUIRE USE OF CONTINUOUS WALL ANGLE. SEE SUPPLEMENT TRACK CHART FOR DETAILS. 2501 S. STATE HWY 121, SUITE 200 <br />LEWISVILLE, TX 75067 <br />FL PE 72613 <br />TX PE 106291 <br />SERIES 170-177, 180-187 PROFESSIONAL ENGINEER'S SEAL PROVIDED ONLY FOR A <br />SUPERIMPOSED DESIGN PRESSURE <br />LOADS ON SUPPORTING STRUCTURE <br />DOOR <br />WIDTH <br />DOOR <br />HEIGHT <br />UNIFORM LOAD EACH JAMB (FILE) <br />S.-O. <br />ALL <br />+184.0/-208.0 <br />+20 A /-234.0 <br />VERIFICATION OF WIND LOAD CONSTRUCTION DETAILS. <br />THE DRAWINGS AND ALL OTHER INFORMATION CONTAINED HERON ARE THE CONFIDENTIAL AND PROPRIERRY PROPE91Y OF OVERflEAD DOOR CORPORATION AND rTs AFFILIATED COMPANIES. THIS DRAWING <br />AND INFORMATION, IN WHOLE OR IN PART, MAY NOT BE COPIED IN ANY MANNER OR DISCLOSED TO MVONE WTTHOUT THE PRIOR WRITTEN CONSENT OF OVERHEAD DOOR CORPORATION, NO DISCLOSURE OF <br />ANY OF TIHIS DRAWING OR INFORMATION 15 INTENDED TO OPERATE AS A LICENSE OR AUTHORIZATION TO USE ff FOR ANY PURPOSE WITHM THE SPECIFIC WRITTEN CONSENT OF OVD;�W DOOR CORPORATION. <br />FINISH 11�, - - — - <br />, �Rrm SERIES 17D, 18OWL <br />,;W4 G. TAYLOR <br />HOLE DIAMETER WHOLE N/A 1W 10/15/10 <br />UNDER .251 +,004/--003 NUMBERS: .25 WS9, 9' W WIDE <br />_25 1 TO .500 +.006/-.003 A UNIT OF <br />OVER .500 1.005/-.00,3 M. SAWICKI 10/25/10 <br />�Xx 03 MEASURE <br />—0 D-41 1043 <br />. — C_ � — FRARONS Xxx :k .010 EACH NONE � W; 11/23/10 <br />REF DWG USED ON 1 1/16 ANGLES. _+ .9 F. TJONG N.T.S_ I - 2 <br />6 5 1 4 1 3 2 1 1 <br />I <br />—M I M� 1 0 <br />SNOISIA38 <br />9 <br />I <br />�Jki 'SNOLLVOOI TUS TIV iV <br />SM380S 3iUdININD 0NI_nI8G <br />A13S i31LXtl--1,11 (Z) <br />Him swo-in Hoviiv <br />13 Q Q NMOHS SV 011VOO1 <br />save-n is>i os vo o�,s7 (so <br />13 Q Q HIIM S8000 NOLLD3S (0) <br />C Q L NMOHS SV 031VOO] <br />s8ve-n IS>i 02 Vo oZ �c (Z) <br />C H.LIM S�1000 NOLL33S (9) <br />NMOHS SV 03LVDOI <br />says-n isA o@ vo oz c (9) <br />13 HIVA S4000 NOLL03S (9) <br />I <br />LWOHS SY C131VO01 <br />S8V@-n ISA 09 VO OZ C (6) <br />H__6M SHOOO NOUO3S <br />NMOHS EV 03iV301 <br />sdvs-n S>i oB vo oz s (m) <br />HLIM SdOOO NOLL03S (8) <br />�Zl <br />31VN088VDA10d ., <br />M�HOS IVI�Iftl_3 <br />31"IYUJ dOW7 <br />(�a <br />L <br />V-Fv-fTcl <br />I�IA <br />'I-E-11 <br />I <br />7Lm�l <br />I <br />He. <br />3NVNJ <br />IIa31X3 <br /><1 <br />My <br />3 <br />% <br />P, A <br />The Genuine. The Original. <br />-S� 0, <br />E N <br />Q Cli <br />3 <br />C 2 <br />0 <br />4 <br />.0 <br />NP 26 3 <br />�Iv k 7" <br />V &V <br />X <br />OverheaciI Door Corporation <br />2501 S. State Hwy 121, Suite 200 <br />Lewisville, TX 75067 <br />)VIV <br />STA-i-E OF <br />Phone 4695497100 <br />Fax 469 49 72B! <br />w .10 S1 - A <br />AT <br />-.4 OR\V <br />�MW.Merhoaddoor.corn <br />Jamb Attachment .... <br />;�` <br />Mefthod of securing the door to the mounting surface is detailed in th In upplement, P/N <br />201 and TAS-203 for large missile impact and cyclic resistance by Certified Testing Laboratories, 7252 <br />Narcoossee Rd. Orlando, F1 32822. <br />4112411. <br />3. Test 85948.02-801-18, <br />November 13'h 2012 <br />It %'% <br />reports 85948.04-801-18, and 8594-&06-801-18 tested in accordance with ASTM <br />2. SCOPE OF EVALUATION iiiiall <br />I E 1886, ASTM E 1996 and ASTM E330 by ATI. <br />Structural Transverse Wind Loads and Large Missile Impact and Cyclic Wind Pressure Resistance. Since every <br />6. INSTALLATION <br />4. Installation instructions and supplemental data sheets prepared by Overhead Door Corporation. <br />door size cannot be tested, engineering analysis using a comparative analysis, as permitted per the Florida <br />All drawings listed in this report are to be installed in accordance with the most recent manufacturer's published <br />9. CODE REFERENCES <br />Subject: Evaluation Report for Models 170-177, 180-187 <br />Product approval 9N-3, were used to analyze the doors and make the wind load designs. <br />installation instructions/drawings and this report. <br />The most recent manufacturer's installation instructions/drawings shall be strictly adhered to and a copy of these <br />Florida Building Code 2010 Edition and/or Standards <br />Section 1609 Wind Loads <br />3. USES <br />instructions/drawings shall be available at -all times on the job site during installation. <br />Section 1715.5.3 TAS 202 <br />To Whom It May Concern: <br />The series number garage doors listed in Table 1 are used for residential and commercial applications with <br />For information about the mounting of the door to the building structure surface, please reference drawing <br />Section 1715.5.3.1 ANSUDASMA 108 <br />specified allowable design pressures, <br />411060. <br />ANSI/DASMA 115 <br />TAS 201,2403 <br />4. DESCRIPTION <br />7. ALLOWABLE TRANSVERSE WIND LOADS <br />SUBMITTED BY: <br />General <br />Design wind load pressures for garage doors shall be determined in accordance with section 1609 of the 2010 <br />10. REPORT SUMMARY <br />Overhead Door Corporation <br />2501 S. State Hwy 121, Suite 200 <br />The series number garage doors listed in Table 1 are sectional overhead garage doors and are constructed of <br />Florida Building Code and shall not exceed the allowable transverse wind loads shown in the following tables: <br />Upon review of the data submitted by Overhead Door Gorporation, it is my opinion that the models as described <br />Lewisville, TX 75067 <br />galvanized steel sections with a two coat polyester finish. The doors are two-inch thick, raised panel or flush, <br />in this report conform with or are a suitable alternative to the code standards and sections In the Florida Building <br />with tongue and groove sections. See table 2 for door designs and corresponding panel thicknesses. The <br />Table 2: Models 170/180 Allowable Transverse Wind Loads and Impact Rating <br />Code 2010 edition listed in section 9 of this report. <br />1. PRODUCT NAME <br />panels are 24 and 25 gage ASTM A653-00 galvanized FS Type B steel, and finished with an ASTIM A525 made <br />For Series Number Shown in Table 1 <br />Reference Table 1 for product names <br />up of G-30 coating, covered with two coats of polyester paint. Each section is reinforced with 16 or 20 gage end <br />INI A on �f I + NI <br />11. LIMITATIONS <br />A IF I ll; <br />Section Type <br />Exterior <br />Steel <br />Thickness <br />Panel Design <br />Series <br />Number <br />Pan <br />25 Ga <br />Short Panel <br />170 <br />Long Panel <br />171 <br />V12 <br />172 <br />V5 <br />175 <br />24 Ga <br />Short Panel <br />173 <br />Long Panel <br />174 <br />V5 <br />176 <br />1 V12 <br />177 <br />Insulated <br />25 Ga <br />Short Panel, 1-5/8" Insul— <br />180 <br />Long Panel, 1-5/8" Insul <br />181 <br />V12, 1-5/8" Insul <br />182 <br />V5, 1-5/8" Insul <br />185 <br />24 Ga <br />Short Panel, 1-5/8" Insul <br />183 <br />Long Panel, 1-5/8" Insul <br />184 <br />V5, 1-5/8" Insul <br />186 <br />V12, 1-5/8" Insul <br />187 <br />Door Tracks <br />All door assemblies listed in this report have both vertical and horizontal tracks ranging from a minimum 16 gage <br />to minimum 15 gage, 33 ksi steel and finished with an ASTM A525 G-40 galvanized coating. The vertical tracks <br />are attached to the supporting structure with jamb brackets as specified on the most recent manufacturer's <br />installation instructions/drawings. <br />Glazed Sections <br />The drawings listed in Table 2 of this report with glazed openings that meet the requirements for impact <br />resistance have glazing that is made of I/V polycarbonate constructed per drawing 410776 or an equivalent <br />product approved for use in Florida, and can be installed in the top or intermediate sections of the garage door. <br />These assemblies are available for use with the glaAng option in wind-borne debris regions and are indicated so <br />in Table 2. The maximum glazing dimensions shall be 18.56" x 12.26," <br />The drawings that are not indicated for use in wind-borne debris regions with the glazing option are available <br />with a minimum of 0.090-inch thick standard SSB glass windows that are installed in frames and inserted in the <br />k-, E AV s� - <br />top or intermediate section of the door. The glazing is not impact resistant and does not meet the requirements <br />for <br />windborne debris regions, Refer to the most recent manufacturer's installation instructions/drawings for glass <br />41 <br />N <br />size limitations. <br />Wind Load Bracincl <br />All drawinas listed in Table 2 of this renort are braced on the inside of the doors with three inch horizontal <br />"y , u e, as ce n I s repo, I Lo 11 a manufacturer s M06L reGenL inlormation is a direct reterence to the most <br />recent information submitted by Overhead Door Corporation to the Florida Building Commission as part of their <br />Florida Product Approval application for the drawings listed in Table 2 of this report. <br />This evaluation report and the most recent installation instructions, when required by the building official, shall <br />be submitted at the time of permit application. <br />The design of the supporting structural elements shall be the responsibility of the design professional for the <br />building structure and in accordance with current building codes for the loads listed in Table 2 of this report. <br />The doors shall not be located in areas where the transverse wind loads exceed the allowable loads shown in <br />Table 2 of this report. <br />The garage door assemblies listed in Table 2 of this report are not approved for use in the "High Velocity <br />Hurricane Zone" as defined in the Florida Building Code- <br />12. IDENTIFICATION <br />Each Model series covered by this report shall be labeled with the manufacturer's name and/or trademark for <br />field identification. <br />Please feel free to contact me if you need any additional information. <br />A S A <br />% <br />% E IV <br />Note 1: The option code assemblies indicated in Table I have optional glazing that has been tested for impact -z <br />E 40 spanning U-bArs. Each U-bar is made of either 1 8-gage or 20-gage ASTM A653-00 steel with a minimum yield Sincerely, <br />STAT 44, — � N' 726 <br />,�o - resistance, and therefore may be used with optional glazing in the wind borne debris region. Z <br />A% 44,/ <br />strength of 80 ksJ and are finished with an ASTM A525 minimum (3-40 galvanized coating. The gage and <br />quantity of U-bar braces varles depending on the amount of wirldload resistance required and the height of the <br />8. SUBSTANTIATING DATA cc <br />41�r * /0NA1, 1�,oN door. OF; <br />1 . Test Report Numbers ETC-06-976-18504.0 and ETC-06-976-18504,1 in accordance with ANSUDASMA 108- S <br />"'lolio m0% In addition to three-inch horizontal spanning U-bars, some of the assemblies listed in Tables 2 of this report are <br />-2005 for lar. <br />hrnr,,zt­1 imith xtnrfi�nl sah imim sm ­fc —1. or, �f n I 9r-i-In fhi,k 911P14-TV h.mi­­ .11- Th. —1- 2002 for transverse wind load.and ANSI/DASMA 115 qe missile impact resistance bv ETC RA-L, A Q­.A,1,i <br />Windload <br />Specification <br />Option Code <br />Maximum Size <br />Positive <br />Design <br />PSF <br />Negative <br />Design <br />PSF <br />Reinforcement <br />Glazing <br />Available <br />(Yes/No) <br />Door Impact <br />Resistant <br />(YerlNo) <br />Width <br />He!-qht <br />411039 <br />91-01, <br />14'-0" <br />15.90 <br />18.20 <br />3", 20 gage U-bars <br />Yes <br />No <br />411040 <br />91-01, <br />14'-0" <br />22-90 <br />26.30 <br />20 gage U-bars <br />Yes <br />No <br />411041 <br />91 -01, <br />14'-0" <br />26.90 <br />30.80 <br />3", 20 gage U-bars <br />Yes <br />No <br />411042 <br />91-0. <br />14'-0" <br />35.70 <br />41.00 <br />3", 20 gage U-bars <br />Yes <br />No <br />411043(') <br />91-01. <br />14'-0" <br />46.00 <br />52.00 <br />3', 20 gage U-bars <br />Yes <br />Yes <br />411044 <br />1 IST-0" <br />1 4�W <br />12.40 <br />13,80 <br />3", 20 gage U-bars <br />Yes <br />No <br />411045 <br />16-0" <br />14'-0" <br />15.30 <br />17.00 <br />3", 20 gage U-bars <br />Yes <br />No <br />411046 <br />16'-0" <br />14'-0" <br />23.00 <br />25.00 <br />3-, 20.9age U-bars <br />Yes <br />No <br />411047") . <br />16'4- <br />14'-0" <br />30.00 <br />33.50 <br />3", 18 gage U-bars <br />Yes <br />Yes <br />411048oT­ <br />16'-0" <br />14'-0" <br />34.40 <br />38.30 <br />3", 18 gage U-bars <br />Yes <br />Yes <br />411049") <br />16'-0" <br />14'-0" <br />46.00 <br />52.00 <br />3", 18 gage U-bars <br />Yes <br />Yes <br />411050 <br />181-0.1 <br />14--0- <br />12.40 <br />13.80 <br />�3", 20 gage U-bars <br />Yes <br />No <br />411051 <br />___41 _1052�) <br />18'-0" <br />14'-0" <br />18.50 <br />20.70 <br />3", 18 gage U-bars <br />es <br />No <br />18'-0" <br />14'-0" <br />34.40 <br />38.30 <br />3", 18 gage U-bars <br />Yes <br />as <br />41 ii)-53(') <br />1&-0" <br />8'-0" <br />34.40 <br />38-30 <br />3", 20 gage U-bars + (1) Aluminiun <br />E <br />Yes <br />411054") <br />18'-0' <br />8'-0" <br />46.00 <br />52.00 1 <br />3", 20 gage U-bars + (1) Aluminium Post I <br />Yes <br />__I <br />ff I <br />Cn <br />IMM� <br />SA <br />