I i L 1 11 1� <br />GENERAL NOTES: <br />1. BEFORE STARTING THE WORK ON THE PROJECT, THE CONTRACTOR WILL HAVE TO VERIFY THE EXISTING <br />CONDITIONS & DIMENSIONS. <br />2. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER. <br />3. THE CONTRACTOR NEEDS TO COMPLY NTH ALL CONSTRUCTION CODES AND REGULATIONS ESTABLISHED <br />BY FLORIDA STATE. <br />4. THE CONTRACTOR NEEDS TO APPLY A GROUND TERMITE TREATMENT ACCORDING TO FLORIDA BUILDING <br />CODE. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING TO ORIGINAL CONDITIONS, ANY DAMAGES TO <br />BUILDING SURFACESt EQUIPMENT, ETC. CAUSED DURING THE CONSTRUCTION. <br />6. THE CONTRACTOR SHALL KEEP ALL AREAS WHERE WORK IS BEING PERFORMED FREE FROM DEBRIS AT <br />ALL TIMES. AREA SHALL BE LEFT BROOM CLEAN AT THE END OF EACH WORKING DAY. <br />7. ALL LUMBER (INTERIOR) SHALL BE COVERED WITH GYPSUM BOARD, r THICKNESS. <br />8. THE CONTRACTOR NEEDS TO COORDINATE WITH THE ELECTRICIAN FOR THE ELECTRICAL WORKS. <br />9. THE CONTRACTOR NEEDS TO COORDINATE WITH THE PLUMBER FOR THE PLUMBING WORKS. <br />10.THE CONTRACTOR NEEDS TO COORDINATE WITH HIS CONSULTANTS FOR THE A/C SYSTEM, ENERGY <br />CALCULATION, ETC. <br />11. THE CONTRACTOR NEEDS TO COORDINATE WITH THE OWNER THE FINISHED FLOOR PRODUCT OF HOUSE. <br />12. THE CONTRACTOR NEEDS TO COORDINATE WITH THE OWNER FOR THE CABINET DIMENSIONS, LAYOUT, OR <br />OTHER INFORMATION. THE CONTRACTOR HAS TO RELOCATE THE HOT & COLD WATER PIPE, THE <br />DISCHARGE PIPES AND THE ELECTRICAL RECEPTACLES ACCORDING TO THE OWNERS LAYOUT. THE <br />CONTRACTOR WILL HAVE TO VERIFY THE EQUIPMENTS (REFRIGERATOR, SINK, DRYER/WASHER) THAT THE <br />OWNER WILL PROVIDE TO DETERMINE THE EXACT LOCATION OF WATER SUPPLY, DISCHARGE PIPE OR <br />ENERGY SUPPLY. <br />13. THE CONTRACTOR NEEDS TO INSTALL IN THE WALL A FIBERGLASS INSULATION R-19 <br />14. THE ROOF CEILING WILL BE 1/2"GYPSUM BOARD AND INSULATED WITH FIBERGLASS INSULATION R-30 <br />(FLAT ROOF). <br />15. ANY LUMBER IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED OR SHALL NEED A SILL <br />GASKET TO AVOID MOISTURE INTRUSION. <br />STRENGTH OF MATERIALS <br />1. <br />CONCRETE FOOTINGS, SLAB & BEAM <br />f c <br />3,000 psi <br />2. <br />REINFORCING STEEL <br />fy <br />60,000 psi <br />3. <br />REINFORCED MASONRY <br />fm <br />1,500 psi <br />4. <br />MASONRY GROUT <br />fc <br />3,000 psi <br />5. <br />SOIL BEARING (ASSUMED, TO BE VERIFIED) <br />2,000 <br />psf <br />6. <br />BOLTS FOR STEEL & WOOD CONNEC11ONS <br />A307 <br />7. <br />FRAMING LUMBER <br />#2 SYP <br />8. SHEATHING DIAPHRAGM (ROOF) <br />8.1. UNBLOCKED DIAPHRAGM <br />9. SHEATHING DIAPHRAGM (WALLS) <br />9.1. UNBLOCKED DIAPHRAGM <br />10. DECK DIAPHRAGM (FLOORS) <br />10.1. UNBLOCKED DIAPHRAGM <br />B APA RATED SHEATHING <br />ALLOWABLE SHEAR=285 POUNDS PER FOOT 10d <br />DEFORMED NAILS 06" O.C. AT ALL ENDS, EDGES, <br />CUTS & TERMINATIONS & 0 12" O.C. AT INTERIOR <br />SUPPORTS. <br />!j APA RATED SHEATHING <br />ALLOWABLE SHEAR=310 POUNDS PER FOOT 10d <br />DEFORMED NAILS 06" O.C. AT ALL ENDS, EDGES, <br />CUTS & TERMINATIONS & 0 12" O.C. AT INTERIOR <br />SUPPORTS. <br />!a APA RATED SHEATHING <br />ALLOWABLE SHEAR=825 POUNDS PER FOOT <br />CONSTRUCT10N ADHESIVE & (2) ROWS OF 10d <br />DEFORMED NAILS 06" O.C. AT ALL ENDS, EDGES, <br />CUTS & TERMINA11ONS & 0 12" O.C. AT INTERIOR <br />SUPPORTS. <br />COMPONENTS & CLADDING WIND PRESSURE CHART <br />TERMITE NOTES.- <br />1. A PERMANENT SIGN WHICH IDEN11FIES THE TERMITE TREATMENT PROVIDER AND NEED FOR <br />RE-INSPEC11ON & TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE <br />POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL. <br />2. CONDENSATE AND ROOF DOWN SPOUTS SHALL DISCHARGE V-0" AWAY FROM BUILDING SIDE WALLS. <br />3. IRRIGATION/SPRINKLER SYSTEM INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED <br />WITHIN V-0" OF THE BUILDING SIDE WALLS. <br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION THE DISTANCE BETWEEN WALL COVERING & <br />FINAL EARTH GRADE SHALL NOT BE LESS THAN 6". EXCEPTION: PAINT OR DECORA11VE CONTEN11OUS <br />FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY TO THE FOUNDATION WALL. <br />5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVA11ON AND BACKFILL IS COMPLETE. IN <br />ACCORDANCE WITH FLORIDA BUILDING CODE 7th ED111ON 2020 SECTION 1816.1.1 <br />6. SOIL DISTRIBUTED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED INCLUDING SPACES BOXED <br />& FORMED. IN ACCORDANCE WITH FLORIDA BUILDING CODE 7th EDITION 2020 SECTION 1816.1.2 <br />7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATIONS OF TRAPS, ETC., SHALL BE <br />MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE THE SIZE AND <br />DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE IN111AL TREATMENT. IN <br />ACCORDANCE WITH FLORIDA BUILDING CODE 7th EDITION 2020 SECTION 2304.11 <br />8. MINIMUM 6 MIL RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF <br />RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. IN <br />ACCORDANCE WITH FLORIDA BUILDING CODE 7th EDIT10N 2020 SECTION 2304.11. <br />9. CONCRETE OVER POUR AND MORTAR ALONG THE FOUNDA11ON PERIMETER MUST BE REMOVED <br />BEFORE EXTERIOR SOIL TREATMENT. IN ACCORDANCE WITH FLORIDA BUILDING CODE 7th ED11ION <br />2020 SEC11ON 2304.11. <br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN V-0" OF <br />THE STRUCTURE SIDEWALLS. IN ACCORDANCE WITH FLORIDA BUILDING CODE 7th ED111ON 2020 <br />SECTION 2304.11. <br />11. AN EXTERIOR VER11CAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUC11ON IS COMPLETE <br />INCLUDING LANDSCAPING & IRRIGATION ANY SOIL DISTRIBUTED AFTER THE VERTICAL BARRIER IS <br />APPLIED, SHALL BE RETREATED. IN ACCORDANCE WITH FLORIDA BUILDING CODE 7th EDITION 2020 <br />SECT1 ON 2304.11. <br />12. ALL BUILDING ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT. IN ACCORDANCE WITH <br />FLORIDA BUILDING CODE 7th ED11ION 2020 SEC11ON 2304.11. <br />13. A CER11FICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE <br />OF COMPLIANCE SHALL STATE: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE <br />PREVENTION OF SUBTERRANEAN TERMITES THE TREATMENT IS IN ACCORDANCE WITH THE RULES & <br />LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE & CONSUMER SERVICES." IN ACCORDANCE <br />WITH FLORIDA BUILDING CODE 7th EDITION 2020 SECTION 2304.11. <br />14. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND <br />WITHIN V-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, TUB TRAP BOXES, FORMS, <br />SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />15. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED WITHIN 15'-0" OF <br />ANY BUILDING OR PROPOSED BUILDING. <br />COMPONENTS & CLADDING ULTIMATE PRESSURE SCHEDULE <br />WALLS, DOORS & WINDOWS ENCLOSE BUILDING <br />GCp, = +/- 0.18 <br />INDICATES OUTWARD; (+) INDICATES INWARD <br />COMPONENTS & CLADDING ULTIMATE PRESSURE SCHEDULE <br />ROOFS & WINDOWS ENCLOSE BUILDING <br />GCpj = +/- 0.18 <br />INDICATES OUTWARD; (+) INDICATES INWARD <br />EFFEC11VE AREA <br />COMPONENT <br />4' OF EAVE OR <br />TRANSITION <br />WITHIN 4! <br />CORNER <br />TRANSITION <br />NOT WITHIN 4' <br />CORNER <br />EFFECTIVE AREA OF <br />COMPONENT <br />WITHIN 4' <br />CORNER <br />NOT WITHIN 4' OF <br />CORNER BUT WITHIN <br />NOT WITHIN 4' OF <br />CORNER, EAVE OR <br />0 SF<AREA<20 SF <br />+36.2 -48.5 <br />+36.2 -39.3 <br />0 SF<AREA<20 SF <br />+20.9 -57.7 <br />+20.9 -57.7 <br />+20.9 -33.2 <br />2U_7ZQMW<7U_7_ <br />+34.7 --45.7 <br />+34.7 -37Y.- <br />20 SF<AREAZU_9F_ <br />+19.0 <br />+19.0 <br />+19.0 -32.2 <br />30 SF<AREA<-40 SF <br />+33.8 -43.3 <br />+33.8 -36.8 <br />30 SF<AREA<40 SF <br />+17' .8 -50.3 <br />+17.8 -50.3 <br />-31.6 <br />40 SF<AREA<50 SF <br />+32.8 -42.1 <br />+32.8 -35.9 <br />40 SF<AREA<50 SF <br />+17.2 -48.5 <br />+17.2 -48.5 <br />_+17.8 <br />+17.2 <br />-31.3 <br />50 SF<AREA<75 SF <br />+32.5 -40.8 <br />+32.5 -35.6 <br />50 SF<AREA<75 SF <br />+16.6 -47.0 <br />+16.6 -47.0 <br />+16.6 <br />-31.0 <br />75 SF<ARF-A<100 SF <br />+31.6 -N.7U- <br />+31.6 -34.7 <br />75 SF<AREA<100 SF <br />+15.4 - <br />+15.4 - <br />+15.4 -30.4 <br />. <br />100 SF<AREA<125 SF <br />+30.7 -37.8 <br />+30.7 -33.8 <br />100 SF<AREA<125 SF <br />+14.7 -42.4 <br />+14.7 -42.4 <br />+14.7 -30.1 <br />125 SF<AREA<150 SF <br />+30.4 -36.5 <br />+30.4 -33.5 <br />125 SF<AREA<150 SF <br />+14.7 -42.4 <br />+14.7 -42.4 <br />+14.7 -30.1 <br />AREA>150 SF <br />+29.8 -35.6 <br />+29.8 -32.8 <br />AREA>150 SF <br />+14.7 -42.4 <br />+14.7 -42.4 <br />+14.7 -30.1 <br />NOTE: ALL BUILDING ELEMENTS EXPOSED TO WIND SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS TO RESIST THE WIND <br />PRESSURES INDICATED & TO MEET OTHER CODE REQUIREMENTS FOR AIR & WATER INTRUSION. WIND LOADS ABOVE ARE ULTIMATE LOADS. <br />USE UL11MATE WIND PRESSURE W/ ASCE-7/16 LOAD COMBINATIONS. MULTIPLY LOADS BY 0.6 TO OBTAIN NOMINAL LOADS. <br />PRODUCT APPROVAL LIST HARDWARE <br />11EM <br />PRODUCT <br />mnnFl <br />SUB <br />CATEGM <br />MANUFACTURER <br />FLORIDA <br />APPROVAL <br />EXPIRATION <br />DATE <br />- <br />1 <br />HUCQ412 <br />FACE -MOUNT HANGER <br />SIMPSON STRONG TIE <br />I <br />FLF10531.1-R5 <br />12-23-23 <br />2 <br />MSTA12/MSTA24 <br />STRAIGHT STRAP <br />SIMPSON STRONG TIE <br />FLfI3872.9-R4 <br />12-31-21 <br />3 <br />ABU44Z/ABU66Z <br />ADJUSTABLE POST BASE <br />I SIMPSON STRONG TIE <br />FL#10860.2-R5 <br />12-17-23 <br />STRUCTURAL NOTES: <br />1. BEFORE STARTING CONSTRUCTION, THE CONTRACTOR NEEDS TO VERIFY THE <br />EXIS11NG COND111ON & DIMENSIONS. <br />2. ALL VERTICAL, HORIZONTACOR DIAGONAL MEMBERS SHALL BE CONNECTED <br />USING STRAP CONNECTORS. <br />3. ALL CONCRETE WORK SHOULD COMPLY NTH ACI 301, ACI 318, ACI 315 <br />LATEST EDITION <br />4. THE REINFORCING STEEL SHALL BE GRADE 60, ASTM A-615 <br />5. THE CONCRETE MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI & W/C <br />0.55 FOR 28 DAYS FOR REINFORCE CONCRETE WALLS <br />6. CONCRETE MASONRY BLOCKS SHALL COMPLY WITH THE REQUIREMENTS OF <br />ASTM C90. MORTAR FOR MASONRY CONSTRUCTION SHALL CONFORM TO THE <br />REQUIREMENTS OF ASTM C270. FILL ALL MASONRY CELLS WITH CONCRETE. <br />7. CONSTRUCTION JOINTS SHALL BE SPACED NO GREATER THAN 20' O.C. <br />8. ALL JOINT REINFORCEMENT, TIES & OTHER ACCESSORIES SHALL BE <br />RESISTANT TO CORROSION. <br />9. THE CONTRACTOR SHALL USE A HOT -DIPPED ZINC -COATED GALVANIZED <br />STEEL BOLTS FOR PRESSURE TREATED WOOD. <br />10. GLUE J" THICK RIGID FOAM PANELS DIRECTLY TO THE INSIDE FACE OF <br />THE CMU. USE FLASHING TAPE TO SEAL ALL JOINTS. THEN FASTEN <br />1"xl" WOOD FURRING STRIPS TO THE CMU AT 16" CENTERS & <br />FASTEN SHEET ROCK <br />11. THE CONTRACTOR NEEDS TO INSTALL A "365 BENT GRIPSTAY CHANNEL SLOT <br />ANCHOR TIES" (OR EQUAL), GA 16 WITH A "362 GRIPSTAY CHANNEL SLOr <br />(OR EQUAL) ON BOTH SIDES OF THE OPENINGS. THE WALL TIES WILL BE <br />INSTALL ON EACH LINE OF THE CMU BLOCKS. <br />12. THE BATHROOM SIDE WALL NEEDS BE COVERED WITH HARDIEBACKER 500 <br />CEMENT BOARD WITH INSULATION. ALWAYS LAY THE HARDIEBACKER BOARD <br />IN A STAGGERED PATTERN. FILL ALL JOINTS WITH THIN SET CEMENT, THEN IN <br />BED 2" WIDE HIGH STRENGTH ALKALI RESISTANT GLASS FIBER TAPE. <br />13. 8"x8" LINTEL BY CAST-CRETE CORP, ADD A #5 REBAR (HORIZONTAL) & <br />#4012- (VERTICAL), FILL WITH CONCRETE & VIBRATE. FILL & VIBRATE ALL <br />CELLS ABOVE LINTEL 'NTH CONCRETE. (EQUAL OR SIMILAR) <br />14. THE CONTRACTOR SHALL PLACE CONCRETE ON THE BATHROOM & <br />DINING ROOM FLOOR UNTIL THEY REACH THE SAME LEVEL OF THE <br />HOUSE. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER <br />THE FINISHED FLOOR PRODUCT/HARDWARE BEFORE PLACING THE <br />CONCRETE TOPPING IN THE LIVING ROOM AREA. THE CONTRACTOR <br />NEEDS TO USE "SIKALATEX R" AS A BOUNDING AGENT BEFORE <br />PLACING CONCRETE TOPPING. <br />15. THE CONTRACTOR SHALL DRILL A J"O HOLE (5") AND FILL WITH <br />EPDXY TYPE HILTY. <br />DESIGN CRITERIA <br />CODE <br />APPLIED = FLORIDA BUILDING CODE 7th EDITION (2020) <br />1. <br />LI VE LOAD <br />ROOF <br />20 PSF <br />FLOOR <br />40 PSF <br />2. <br />DEAD LOAD <br />ROOF <br />15 PSF <br />3. <br />WIND LOADS <br />140 MPH (ULTIMATE) <br />RISK CATEGORY <br />11 <br />EXPOSURECATEGORY <br />wB" <br />INTERNAL PRESSURE <br />COEFFICIENTS; GC <br />*±0.18, ENCLOSED <br />STRUCTURE <br />*0.55, PARTIALLY <br />ENCLOSED STRUCTURE <br />*0.0 OPEN STRUCTURE <br />BASIC WIND PRESSURE <br />q=50.1 PSF <br />4. <br />SOIL BEARING <br />(ASSUMED TO BE VERIFIED) <br />Sb=2000 PSF <br />5. <br />CLASSIFICATION OF WORK <br />ALTERA11ON LEVEL 2 <br />6. <br />TYPE OF CONSTRUCTION: <br />TYPE V-B <br />APPLICABLE CODES <br />FLORIDA BUILDING CODE 7TH EDITION (2020) <br />2020 <br />FLORIDA BUILDING CODE, PLUMBING <br />2020 <br />FLORIDA BUILDING CODE, MECHANICAL <br />2020 <br />FLORIDA BUILDING CODE FOR <br />BUILDING CONSTRUCTION <br />2020 <br />FLORIDA BUILDING CODE EXISTING <br />BUILDING <br />2020 <br />FLORIDA ENERGY EFFICIENCY <br />CODE FOR BUILDING <br />CONSTRUC11ON <br />2017 <br />NATIONAL ELECTRICAL CODE <br />0 <br />oil MR$ <br />Eli i <br />1Y ii L, # =� 0, �: L A <br />2810 NORTH 10TH STREET <br />I TAMPA, FL 33605 1 <br />Office: (813) 616-3301 <br />Mobile (970) 703-3284 <br />Leo@Ber�ProjectEngineering.com <br />IFE'VKNONS <br />No. DESCRIPTION DATE <br />Ak I - - - - <br />N <br />0 <br />LC) <br />Lj <br />n <br />< <br />LLJ <br />LLJ <br />> <br />3: <br />0:� <br />0 <br />0 <br />z <br />n <br />Ld <br />ry <br />z <br />0 <br />00 <br />_j <br />ry <br />0 <br />(.0 <br />ry <br />< <br />0)'__ <br />LLJ <br />ry <br />0 <br />m <br />In <br />N <br />BUILD IN ACCORDANCE NTH: <br />FLORIDA BUILDING CODE, <br />7TH EDITION, 2020 <br />(CURRENT EDITION) <br />DESCRIPTION <br />NOTES <br />L EP/V <br />kC E N <br />% <br />No. 65994 <br />STATE OF <br />10 <br />0 <br />pe $ 44 <br />OXN (4 <br />�Z <br />to <br />0 R <br />0 NA L <br />8888111112111,01 <br />Richard Leon Cannyn, PMP, P.E. <br />P.E. # 65994 <br />SCALE 0. <br />AS -SHOWN N-1 <br />PROJECT No. DRAFTER: BRM DESIGNER: LG <br />15558 REVIEWER: LV <br />To BE CHECKED BY- LC <br />DATE SHUT No. <br />8/18/2021 1 4 OF 4 <br />