Laserfiche WebLink
REPAIR/RESTORATION OF PORCII <br />APPLICABLE CODES AND STANDARDS <br />2017 FLORIDA <br />BUILDING CODE - RESIDENTIAL, SIXTH EDITION <br />2017 FLORIDA <br />BUILDING CODE - BUILDING, SIXTH EDITION <br />2017 FLORIDA <br />BUILDING CODE - ENERGY CONSERVATION, SIXTH EDITION <br />NFPA 70 - NATIONAL ELECTRICAL CODE, 2014 EDITION <br />2017 FBC BUILDING CODE - EXISTING BUILDING, SIXTH EDITION <br />CHAPTER 6 - <br />REPAIRS <br />SECTION 601 <br />- GENERAL <br />SECTION 602 <br />- BUILDING ELEMENTS AND MATERIALS <br />SECTION 606 <br />- STRUCTURAL <br />SECTION 706 <br />- EXISTING ROOFING <br />SCOPE: THE EXISTING SCREENED PORCH WAS DAMAGED BY A VEHICLE <br />CRASHING INTO IT. THE REPAIR / RESTORATION OF THE PORCH WILL <br />CONSIST OF MATCHING ORIGINAL CONFIGURATION, HEIGHT, SIZE, LIKE <br />MATERIALS, ROOF SLOPE AND ORIGINAL METHOD OF CONSTRUCTION. <br />BUILDING CODE ANALYSIS <br />OCCUPANCY TYPE: <br />GROUP R <br />CLIMATE ZONE: 2A PASCO <br />REQUIRED: <br />INSULATION IN ATTIC: R-38 <br />MASS (CMU WALL): R-7.6 <br />WOOD FRAME: R-13 + R-3.8 OR R-20 <br />PROVIDED: <br />NOT APPLICABLE, OPEN SPACE NON -HEATED AREA. <br />CONSTRUCTION TYPE: VB <br />TABLE 504.3; ALLOWABLE BUILDING HEIGHT = 40 FEET <br />TABLE 504.4; ALLOWABLE NUMBER OF STORIES = 3 <br />TABLE 506.2; ALLOWABLE AREA = UNLIMITED SF <br />TABLE 601 - BUILDING ELEMENT <br />FIRE -RESISTANCE RATING REQUIREMENTS (HOURS) <br />TYP E V <br />8 <br />PRIMARY STRUCTURAL FRAME <br />0 <br />BEARING WALLS <br />EXTERIOR <br />INTERIOR <br />0 <br />0 <br />NONBEARING WALLS AND PARTITIONS TABLE 602 <br />EXTERIOR 10 < X < 30 <br />0 <br />NONBEARING WALLS AND PARTITIONS <br />INTERIOR <br />0 <br />FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS <br />0 <br />ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS <br />0 <br />SQUARE FOOTAGE BREAKDOWN <br />RESIDENCE: <br />FLOOR (LIVING AREA) HEATED - A/C SPACE: 1,488 SF <br />GARAGE: 528 SF <br />PATIO: 240 SF <br />SCREENED PORCH: (RECONSTRUCTED) 200 SF <br />TOTAL SQUARE FOOTAGE: 2,456 SF <br />PRODUCT APPROVAL <br />PRODUCT <br />CATEGORY <br />MANUFACTURER <br />SUB CATEGORY <br />MATERIAL <br />FLORIDA <br />APPROVAL # <br />ROOFING <br />GAF <br />ASPHALT SHINGLES <br />ASPHALT <br />FL1 0124.1 <br />ROOFING <br />CERTAINTEED CORP. <br />ASPHALT SHINGLES <br />ASPHALT <br />FL5444 <br />NOTE: <br />IF OWNER OR CONTRACTOR WANTS TO USE A DIFFERENT PRODUCT, CONTRACTOR SHALL <br />SUBMIT COPY OF PRODUCT APPROVAL DOCUMENTATION TO BUILDING DEPARTMENT. <br />5315 5TH STR T, <br />PHYRHI S, F ORIDA 33542 <br />chul, Christ <br />Subway Restau rw <br />AutoZane Auto Parts Zephyrhil <br />The Broach School Public Libra <br />(7-EPHYR,H ILLS-) <br />r I <br />_61P IF531-15 5th Street <br />Greut Starl <br />'D <br />Learning Center <br />Gc-In" Po <br />Mike Keys <br />'all'i Ave Locks m ith Servi c4-, <br />hllyne�" i ._.L:ount <br />mo�� Home <br />First Baptisst Chui <br />Tenney's, Custom A% <br />Saddlepyy U:-j (:54) <br />C3- <br />PROJECT LOCATION MAP: 5315 5TH STREET, ZEPHYRHILLS, FL 33542 <br />PARCEL ID: 11-26-21-0010-12400-0070 <br />CLASSIFICATION: 00100 - SINGLE FAMILY <br />LEGAL DESCRIPTION: <br />CITY OF ZEPHYRHILLS PB 1 PC 54 <br />LOTS 7, 8 & NORTH 10.00 FT LOT 9 <br />BLOCK 124 OR 7753 PC 1561 <br />YEAR BUILT: 1979 <br />GENERAL NOTES: <br />1. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONAL INFORMATION. <br />2. PLUMBER TO INFORM GENERAL CONTRACTOR OF ANY VENTING, WHICH UTILIZES <br />A MASONRY WALL TO RESOLVE ANY POSSIBLE STRUCTURAL INTEGRITY ISSUES. <br />3. NOTES, TYPICAL DETAILS AND SCHEDULES APPLY TO ALL STRUCTURAL <br />WORK UNLESS OTHERWISE NOTED. FOR CONDITIONS NOT SPECIFICALLY <br />SHOWN, PROVIDE DETAILS OF A SIMILAR NATURE. VERIFY <br />APPLICABILITY BY SUBMITTING SHOP DRAWINGS FOR REVIEW. <br />4. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE <br />SPECIFICATIONS, ARCHITECTURAL, ELECTRICAL, PLUMBING AND MECHANICAL <br />DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS IT IS THE CONTRACTOR'S <br />RESPONSIBILITY TO NOTIFY THE ENGINEER PRIOR TO PERFORMING WORK. <br />5. TOP OF CONCRETE SLABS ARE AT FLOOR REFERENCE ELEVATIONS <br />EXCEPT AS NOTED. <br />6. AT ALL TIMES THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR <br />THE CONDITIONS OF THE JOBSITE INCLUDING SAFETY OF PERSONS <br />AND PROPERTY. THE ARCHITECT'S OR ENGINEER'S PRESENCE OR <br />REVIEW OF WORK DOES NOT INCLUDE THE ADEQUACY OF THE <br />CONTRACTOR'S MEANS OR METHODS OF CONSTRUCTION, <br />7. INTERIOR WALL AND CEILING FINISH. <br />FINISH MATERIALS SHALL BE CLASS A, CLASS B OR CLASS C. <br />V11-111 RjEVAlLjjVG <br />000j5p, <br />7 - <br />DRAWINGS INDEX <br />SHEET DESCRIPTION <br />A-0 <br />COVER SHEET - CODE ANALYSIS <br />A-1 <br />GENERAL NOTES <br />A-2 <br />DEMOLITION PLAN <br />A-3 <br />FLOOR AND FOUNDATION PLANS <br />A-4 <br />ELECTRICAL PLAN <br />A-5 <br />ROOFPLAN <br />A-6 <br />ROOF FRAMING PLAN <br />A-7 <br />EXTERIOR ELEVATIONS <br />A-8 <br />TYPICAL DETAILS <br />ENGINEER'S EXCLUSION TABLE: <br />1. EXISTING CONNECTIONS OUTSIDE OF SCOPE OF WORK, <br />2. FIREPROOFING. <br />3. ENVELOPE / WATERPROOFING. <br />4. M.E.P. DESIGN. <br />5. EXISTING FOUNDATION ANALYSIS. <br />6. FLOOR / WALL FRAME AND WEATHER PROTECTION SYSTEM OUTSIDE OF <br />SCOPE OF WORK. <br />7. FINISH MATERIALS. <br />8. TERMITE INSPECTION / REMEDIATION. <br />9. MEANS AND METHODS. <br />10. CONSTRUCTION SAFETY. <br />THE ENGINEER IS RESPONSIBLE FOR ELEMENTS OF THE SIGNED AND SEALED <br />DRAWINGS. ITEMS LISTED IN THE ENGINEER EXCLUSION TABLE ARE EXCLUSIONS <br />OF THE ENGINEER'S RESPONSIBILITY AND ARE NOT EXCLUSIONS OF RETROFIT <br />RELATED TO OR NEEDED TO COMPLETE THE PROJECT. ALL RETROFIT WORK <br />WILL BE THE RESPONSIBILITY OF A LICENSED CONTRACTOR. <br />SCOPE OF WORK <br />THE EXISTING SCREENED PORCH WAS DAMAGED BY A VEHICLE <br />CRASHING INTO IT. THE REPAIR / RESTORATION OF THE PORCH WILL <br />CONSIST OF MATCHING ORIGINAL CONFIGURATION, HEIGHT, SIZE, <br />LIKE MATERIALS, ROOF SLOPE AND ORIGINAL METHOD OF <br />CONSTRUCTION. THE PROPERTY IS A 1-STORY SINGLE FAMILY HOME <br />LOCATED IN ZEPHYRHILLS, FLORIDA <br />ARCHITECT'S OR ENGINEER'S AFFIDAVIT STATEMENT <br />TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS <br />AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES <br />AND THE APPLICABLE FIRE SAFETY STANDARDS AS DETERMINDED BY LOCAL <br />AUTHORITY IN ACCORDANCE WITH THIS SECTION AND CHAPTER 633, FLORIDA STATUTES. <br />2 <br />0 <br />y <br />11:4w� <br />z <br />Ln <br />r2 z zi <br />1­4 0 <br />P41-4 <br />w C/) <br />P4 P4 <br />z C:) <br />LAz Z <br />MP4 <� <br />Issued for: <br />Date: <br />El PRELIMINARY <br />El PRICING <br />El BIDDING <br />0 PERMIT <br />12/27/2019 <br />E REVISION #1 <br />Ln <br />66 <br />Ln <br />PEN"I <br />'p" <br />Ln <br />P= <br />Ln <br />Feel <br />License Number: 73539 <br />[ rawn by: A=O SE, PE <br />D FRANK DE-JO, <br />