24$-0)' <br />EXISTING PORCH CONCRETE <br />EXISTING EXTERIOR WALL AND SLAB TO REMAIN <br />TRUSS FRAMING TO BE REVIEWED <br />0 <br />TO ENSURE DAMAGE MEMBERS I SCREENED PORCH <br />ARE IDEN11FIED AND REMOVED. <br />NOTIFY ENGINEER OF ANY <br />DAMAGE MATERIALS. EXISTING ALUMINUM SCREEN DOOR <br />TO BE REMOVED <br />EXISTING SCREENING, WOOD <br />FRAMING AND CMU WALL <br />TO BE REMOVED <br />DEMOLITION <br />CALE: 1/4 )1 = 1 <br />24'—Op$ <br />EXISTING SCREENING, WOOD <br />FRAMING AND CMU WALL <br />TO BE REMOVED <br />GENERAL DEMOLITION NOTES: <br />1. THE CONTRACTOR SHALL BE FAMILIAR WITH AND PERFORM ALL REMOVAL WORK IN ACCORDANCE WTH <br />FLORIDA BUILDING CODE CHAPTER 33, "SAFEGUARDS DURING CONSTRUCTION" . <br />2. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND SAFETY PROTECTION DURING DEMOLITION <br />PERIOD AS REQUIRED BY BUILDING CODE CHAPTER 33 TO PROPERLY PERFORM THE WORK. <br />3. SHORING, BRACING AND PROTECTION OF EXISTING AND ADJACENT STRUCTURES DURING CONSTRUCTION <br />IS THE SOLE RESPONSIBLE OR THE CONTRACTOR. PROTECT AND MAINTAIN THE INTEGRITY OF <br />ADJACENT BUILDING AND STRUCTURES. <br />ALTER OR DAMAGE THE FLOOR OR CEILING SLABS, EXCEPT AT AREAS NOTED ON PLAN, <br />5. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR AND PATCH ALL LOCATIONS ASSOCIATED <br />WITH DEMOLITION AND REMOVAL OF ADJACENT FINISHES, FRAMING, ETC.. <br />ALL MATERIALS, DOORS & FRAMES, FINISHES THAT ARE TO REMAIN AT COMPLETION. <br />7. ALL ITEMS TO BE REMOVED ARE SHOWN WITH DASHED / HIDING LINES. REMOVE ENTIRE PARTITIONS; <br />INCLUDING BUT NOT LIMITED TO GYPSUM BOARD, STUDS, FASTENERS, FINISHES AND BUILDING UTILITIES <br />WITHIN PARTITION. RE—ROUTE, CUT AND CAP OFF UTILITIES WITHIN WALLS AS REQUIRED. <br />8. REMOVE ALL FLOOR FINISHES IN THEIR ENTIRELY, DOWN TO THE ORIGINAL FLOOR SLAB / DECK; <br />INCLUDING BUT NOT LIMITED TO CERAMIC TILES, CARPETS OR VINYL COMPOSITION TILES, <br />9. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONTRACTOR'S MEANS OR METHODS OF <br />CONSTRUCTION AND CONDITIONS OF THE JOBSITE INCLUDING SAFETY OF PERSONS AND PROPERTY. <br />10. ALL EXISTING DIMENSIONS AND LOCATIONS OF EXISTING STRUCTURES SHOWN ON THE DRAWINGS <br />SHALL BE FIELD VERIFIED, ANY DISCREPANCIES SHALL BE REPORTED THE DESIGNER OF RECORD. <br />11. DRAWINGS HAVE BEEN PREPARED BASED ON AVAILABLE KNOWLEDGE OF EXISTING CONDITIONS. IF <br />DURING DEMOLITION OR CONSTRUCTION, ACTUAL CONDITIONS ARE DISCOVERED TO DIFFER FROM THOSE <br />INDICATED ON DRAWINGS, THE DESIGNER OF RECORD SHALL BE NOTIFIED. <br />r2zz <br />P-4 (.9 <br />P4 P-4 <br />W(/) <br />P4 P4 <br />z <br />LL: <br />Issued for: <br />Date: <br />El PRELIMINARY <br />El PRICING_ <br />El BIDDING <br />0 PERMIT <br />12/27/2019 <br />El REVISION #1 <br />