0 � <br />"I <br />A <br />00 <br />ZI; <br />E <br />D G H <br />0 Notes: <br />1. FIELD COORDINATE FLOW AND TAMPER DUAL MONITOR MODULE WITH SPRINKLER CONTRACTOR. <br />General Notes: <br />1. WIRING, RACEWAYS, AND DEVICES SHALL BE INSTALLED IN ACCORDANCE WITH <br />ALL APPLICABLE CITY CODES, FLORIDA FIRE PREVENTION CODE-2010, & NFPA-72 2007 EDITION. <br />2. CONDUIT, CONDUIT STUBS, AND CONNECTORS SHALL BE FURNISHED AND INSTALLED <br />BY ELECTRICAL CONTRACTOR. AS-BUILTS SHALL REFLECT EXACT CONDUIT ROUTING. <br />3. RTU SHUTDOWN RELAYS MUST BE LOCATED WITHIN 36" OF RTU CONTROLS. <br />4. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 36" OF ANY BUILDING COLUMN <br />OR SUPPLY AIR GRILLE, <br />5. ALL DUCT DETECTOR INSTALLATION AND SHUT DOWN WIRING TO AC UNIT SHALL BE <br />DONE BY MECHANICAL AND/OR CONTROL CONTRACTOR. <br />6. CABLE PATHWAYS ARE DIAGRAMMATIC. ACTUAL CONDUIT LAYOUT WILL BE BASED ON SITE CONDITIONS, <br />AND WILL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR <br />7. FIRE PANEL 120VAC SURGE SUPPRESSORS SHALL BE INSTALLED ACCORDING MANUFACTURES <br />RECOMMENDATIONS. ALLOW UNIT REACTION TIME BY ALLOWING NO LESS THAN 3'OF CONDUCTOR BETWEEN <br />THE DTK-1 20HW AND THE PANEL ITS PROTECTING. <br />Circuit Legend <br />Abbreviation <br />Type <br />Name <br />A <br />Signaling Line <br />18/2 AWG FPLR <br />N <br />Notification <br />(2) #14 AWG THHN (Blue & Yellow) <br />S <br />Annun. <br />(2)#1 4AWG TH HN , & (2) #16/2 FPLR <br />Y <br />Power <br />(2)#14AWG THHN (Red & Black) <br />Fire Alarm Symbol Legend <br />SYMBOL <br />DESCRIPTION <br />MODELNUMBER <br />F ___j <br />IACI <br />Fire Warden Fire Alarm Control Panel <br />NFW2-100 <br />ENI <br />Remote LCD Annunciator (black) <br />N-ANN-80 <br />12 <br />Fire Alarm Strobe <br />SIR <br />Em <br />Fire Alarm Horn / Strobe <br />P2R <br />NEK <br />Fire Alarm Horn / Strobe (ceiling mount) <br />PC2W <br />El <br />Addressable Pull Station <br />NBG-12LX <br />Addressable Dual Monitor Module <br />NDM-100 <br />Addressable Relay Module <br />NC-10OR <br />@ <br />Addressable Thermal Detector <br />NH-100 <br />Addressable Photo Detector <br />NP-100 <br />Addressable Duct Detector <br />DNR <br />Remote Test Station <br />RTS-151 <br />120VAC Surge Suppressor <br />DTK-120HW <br />DITEK SURGE <br />SUPPRE SSOR <br />I DTK-120HW I <br />120VAC FROM 9 N�11 (D <br />DEDICATED 120VAC TO FACP <br />BRANCH CIRCUIT <br />,e <br />4 SQUARE JUNCTION BOX SHALL BEA MINIMUM <br />3'FROM FACP (SEE GENERAL NOTE 7) <br />120VAC SURGE SUPPRESSION <br />NO SCALE <br />CEILING MOUNTED <br />5MO&ICTEA T__-, <br />M N) <br />N(FPIA <br />R <br />CQUNG <br />vl�l <br />T <br />A/C SUPPLY DIFFUSER ACCEPTABLE HERE <br />4 <br />AUDIO —ONLY <br />'0' MIN TO TO TOP NOT <br />DO NOT INSTA <br />DEVICES <br />LESS THAN 6" FROM <br />I EA <br />IN THIS AREA <br />CEILING PER NFPA 72 2007 CE]UNG MOUNTED <br />EDITION (SECTION 7.7.7.1) <br />NOTIFICATION DEVICE <br />WALL MOUNTED <br />SEE PLAN FOR LOCATION. <br />r <br />HEAT DIETECTO <br />BOTT <br />TO THE BOTTOM. <br />AUDIO/VISUAL <br />WALL MOUNTED <br />& VISUAL —ONLY <br />5' —0— <br />SMOKE DETECTO <br />DEVICES <br />MAX FROM EXIT DOOR <br />TO THE TOP. <br />SPEAKER STROBES <br />.4 <br />R�QUIRE A <br />4 DEEP BOX <br />(TYPICAL DISTANCE) <br />REh <br />/_AN1 <br />MANUAL <br />PULL <br />STATION <br />80" MIN <br />96'MAX <br />NFPA 72 2007 <br />EDITION <br />(SECTION 7 . 5.4) <br />(UNLESS OTHIERWISE NOTED) <br />0 <br />46" TO THE WORKING MECHANISM <br />iL <br />< <br />FINISHE 2 <br />12" <br />DEVICE MOUNTING ELEVATION GUIDE MOUNT ALL DETECTORS 0 A 4 - SO BOX <br />MOUNT SPEAKER/STROBES ON A 4� SQ DEEP 13OX <br />NO SCALE MOUNT HORN/STROBES ON A 4- SO BOX WITH A SINGLE GANG P-RING <br />MOUNT PULL STATIONS ON A 4" SQ BOX WITH A SINGLE GANG P-RING <br />FIRE ALARM FLOOR PLAN <br />SCALE: 1/8" 1'4' <br />0 41 & 24' <br />z <br />0 <br />U) <br />LO <br />U <br />z <br />0 <br />0') <br />0 <br />(D 00 LO <br />CA r- <br />co (N <br />0 <br />I? <br />LL <br />_j <br />0 <br />U) <br />a) M d) <br />-FV -0 1,- <br />0 > r- (N <br />F_ -2 <br />LU <br />(D <br />ucl: <br />>1 <br />"� <br />0 LL 0 <br />(D <br />0 <br />-0 U) Lo -'0 , <br />__j <br />(0 0 C C <br />0 -t-- _T 0 <br />(D <br />76 <br />Uj <br />4-; <br />LL <br />Z) <br />LO Z3 - _,- <br />0 CS U) 0 0- <br />U) <br />M <br />0 <br />70 <br />z M <br />0 7= <br />0 <br />W CU <br />DO <br />C) co <br />> co LID <br />cc" 0� <br />w E <br />M <br />< 'D <br />c') <br />C�) <br />W <br />> <br />L) S2 M co <br />> <br />P_ <br />0.2 <br />0� 0(o 00 <br />LL �; <br />M <br />0 <br />0 i> bi LL <br />z <br />z <br />0- 0) C <br />CO E o = <br />0— CU I-Z 0 <br />Q) <br />0 Lo F a. i­- <br />< <br />LL <br />0 <br />U <br />.j <br />< <br />0 <br />0 <br />LU <br />LU <br />LL <br />]z <br />00 <br />LU <br />N <br />LU <br />Lr) <br />N <br />26, 2014 <br />ZLMay <br />Additional Smoke Devices <br />August <br />4, 2014 <br />Removal of Smoke Devices <br />Quality Control <br />SYSTEM ENGINEER: <br />Date Signed: <br />M.A.N <br />REVIEWED BY: <br />M.E.S <br />INDEPENDENT REVIEWER: <br />DATE ISSUED: <br />August 04, 2014 <br />CONTRACT SHEET <br />NO. <br />E5.0 - FIRE ALARM PLAN <br />DRAWING NO. <br />FALK <br />