Laserfiche WebLink
PROPOBED ELECTRICAL PLAN <br />ELECTRICAL LEGEND : <br />ELECTRICAL WIRING <br />LIGHT FIXTURE <br />ARC, -FAULT CIRCUIT INTERRUPTER <br />DUPLEX OUTLET <br />WALL SWITCH <br />NOTE: <br />ELECTRICAL LAYOUT 15 A 5CHEMATIG ONLY. <br />GON5ULT LICENSED ELECTRICAL CONTRACTOR, <br />GENERAL CONTRACTOR AND/OR OWNER BEFORE <br />INSTALLING ANY ELECTRICAL FIXTURE <br />MAKE NEW ELECTRICAL CONNECTIONS TO <br />EXISTING MAIN PANEL AT EXI5TINC SPARE <br />CIRCUITS AND VERIFY ALL RESULTANT LOAD5. <br />NEC, 2017 210.12 ALL 120-VOLT, <br />SINGLE PHASE,15- AND 20 AMPERE <br />BRANCH CIRCUITS 5UPPLYING OUTLETS <br />INSTALLED IN DWELLING UNIT FAMILY, <br />DINING, LIVING, BEDROOMS, LIBRARIES, <br />PARLOURS, DENS, SUNROOMS, CLOSETS, <br />RECREATION RMS., CLOSET, HALL104AY5 <br />OR SIMILAR ROOMS OR AREAS SHALL <br />BE PROTECTED BY A LISTED (AFCI)- <br />ARC-FAULT CIRCUIT INTERRUPTER <br />NOTE: <br />SUNROOM "A" HAS <br />EXISTING MECHANICAL. <br />SUNROOM "B" WILL NOT <br />BE CONDITIONED. <br />DEN AREA WILL NOT BE <br />CONDTIONED. <br />GENERAL NOTE5: <br />ALL WORK SHALL CONFORM WITH THE LATEST ADOPTED EDITION <br />OF THE FLORIDA BUILDING GORE, MECHANICAL CODE, PLUMBING <br />CODE, THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE <br />CODES AND REGULATIONS, LOCAL, CITY, STATE, FEDERAL, SAFETY <br />BOARD OF FIRE UNDERWRITERS AND FIRE DEPARTMENT. <br />WORKMANSHIP SHALL BE EQUAL TO THE BEST TRADE PRACTICES <br />ALL INSTALLATIONS OF MANUFACTURE'5 SPECIFICATIONS SHALL BE <br />IN EXACT COMPLIANCE WITH MANUFACTURE'S PRINTED <br />INSTRUCTIONS. <br />CONTRACTOR AND/OR OWNER SHALL VERIFY ALL EXISTING <br />CONDITIONS AND DIMENSIONS BEFORE ANY PHASE OF <br />CONSTRUCTION 15 TO COMMENCE. <br />CONTRACTOR AND/OR OWNER SHALL COORDINATE ALL WORK <br />BETWEEN SITE, BUILDING, ELECTRICAL, MECHANICAL AND <br />PLUMBING BEFORE EACH PHASE OF CONSTRUCTION BEGINS. <br />DO NOT 5CALE PLANS. <br />STANDARD 90 HOOK <br />GONT. 12" WIDE x 16" DEEP _ <br />MONOLITHIC SLAB EDGE/FTG. <br />W/ (2) #5's CONT. LAP <br />SPLICES MIN. 24" 8 TIE <br />w / WIRE. TYP. @ PERIMETER <br />0" <br />LAP SPLICE <br />10' <br />4"THICK GONG. SLAB w / bxb <br />10/10 W.W.F OR FIBERME5H <br />REINF. ON b MIL. POLYETHYLENE <br />VAPOR BARRIER ON GLEAN <br />COMPACTED SAND FILL w / SOIL <br />POISONING (TYP.) <br />NEW 5UNROOM FIN. FL. <br />SLAB ELEV = 85.25' <br />5LA9 To MAl" EXI5TIN& <br />EXISTING FIN. FL. <br />SLAB ELEV = 85.25' <br />NOTE: <br />2' CONTRACTOR TO SAWGUT UNDER EXISTING <br />SLAB TO ADD 12x16 FOOTER TO THI5 AREA. <br />_A_ AP UP EXIST <br />. 5 . SLAB TO <br />MATCH HOUSE FF 3"t <br />NEW SUNROOM FIN. F� <br />SLAB ELEV = 85.25' <br />BOND NEW FTC. TO EXISTING FTC. <br />BY DOWELING (2) NEW #5's REINF. <br />STEEL INTO EXIST. FTC. MIN. 7" AND <br />SET w / EPDXY GROUT (TYP. <br />EXISTING 5LAB AND <br />FOOTER TO REMAIN <br />4X12 <br />GONG. <br />STOOP <br />ELEV = 85 <br />WHERE NEW SLAB MEET EXIST. SLAB <br />ALL THE WAY AROUND ... TIE NEW <br />SLAB. REINF. STEEL INTO EXISTING. <br />BY DOWELING NEW (1)#5 @ 5' 0.6 <br />INTO EXIST. FTC. MIN. 7" AND SET W/ <br />EPDXY GROUT (TYP.) / <br />3. <br />4' <br />PROP05ED FOUNDATION PLAN <br />CONCRETE: <br />3.1 CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS: 3000 P51 (NORMAL WEIGHT). <br />3.2 REINFORCING BARS: A5TM A615 (GRADE 40). <br />3.3 WELDED WIRE FABRIC, (WWF): A5TM A185. <br />5.4 DETAIL REINFORCEMENT IN ACCORDANCE WITH AGI 315. <br />3.5 CONCRETE COVERAGE OF REINFORCEMENT: FOOTINC75 3" BOTTOM AND SIDES. <br />3.6 EARTH SUPPORTED SLABS: (INCLUDING EXTERIOR WALK AND DRIVE 5LA55) 3 <br />%s" THICK, REINFORCED WITH 6X6 MESH MAY BE USED IN LIEU OF WWF AT <br />CONTRACTOR'S OPTION. <br />3.7 CONCRETING OPERATORS SHALL COMPLY WITH AGI STANDARDS. <br />3.8 LAP SPLICE SHALL BE AS FOLLOW5: #7 BAR 35", #b BAR 30", #5 BAR 25", <br />#4 BAR 20", #3 BAR 15". <br />0\��p`►t'A. GO <br />LICENSE <br />No 4743 <br />-Q <br />i 7�, STATE OF <br />FLORIDA <br />This Item has been electronically signed and <br />sealed by Dr. Ram A. Goel using a Digital <br />Signature and date. Printed copies of this <br />document are not considered signed and <br />sealed and signature must be verified on any <br />electronic copies <br />Digitally signed by Ram Goal <br />DN: <br />E-SoneykiW@ tehoo.com, <br />Ram Goal OUNEm Goal, <br />OI�NGINEERING, <br />O■Sonay FM LLC, <br />L"Tampa, SAFINkle, C=US <br />Date: 2022.0&11 <br />10:13:20-04'00' <br />I HEREBY CERTIFY THAT I HAVE REVIEWED <br />AND SUPERVISED THE ATTACHED DE516N <br />AND FOUND IT TO BE IN COMPLIANCE WITH <br />THE 2020 F.B.G. RESIDENTIAL 7TH EDITION <br />DR. RAM A. GOEL, P.E.(#47431) <br />SONEY FM LLC, GA # 9746 <br />GORY LAKE PROFESSIONAL CENTER <br />10329 CROSS CREEK BLVD., SUITE P <br />TAM PA, FL 33647 Ph: 613-293-1865 <br />LU <br />J <br />< <br />w <br />kn <br />:�t <br />n <br />< <br />Q <br />Cw <br />ul <br />z <br />ztu <br />w <br />OQ <br />zW, <br />_ m <br />tf) <br />WE -j <br />VQ <br />JU <br />z <br />O <br />wm <br />In <br />In <br />z_ <br />O <br />z <br />O <br />lti <br />LU <br />} <br />7— <br />O <br />V <br />0 <br />O <br />Q <br />w <br />N <br />Ln <br />�m <br />o� U_ <br />o <br />O� <br />Q <br />x <br />OW <br />QN <br />w< <br />Q <br />3 z <br />Q O <br />wWE <br />� <br />} N <br />O%Z <br />z Ln <br />LU <br />z <br />:5 <br />WE <br />w <br />} <br />O <br />V <br />to <br />X <br />w <br />n <br />A-2 <br />