4 <br />r <br />ENGINEER'S NOTES <br />ALL WORK TO BE DONE ACC❑RDING TO FLORIDA BUILDING CODES, <br />BUILDINGS OR STRUCTURES SHALL CONFORM TO <br />2020 FBC 7th, EDITI❑N BUILDING. <br />AN ADDITI❑N TO A BUILDING OR STRUCTURE SHALL COMPLY WITH THE FBC'S AS <br />FOR NEW C❑NSTRUCTI❑N WITH❑UT REQUIRING THE EXISTING BUILDING OR STRUCTURE <br />TO COMPLY WITH ANY REQUIREMENTS OF THOSE CODES OR OF THESE PR❑VISI❑NS <br />EXCEPT AS REQUIRED BY CHAPTER 10, WHERE AN ADDITI❑N IMPACTS THE EXISTING <br />BUILDING OR STRUCTURE, THAT P❑RTI❑N SHALL COMPLY WITH THIS CODE. <br />CREATI❑N OR EXTENSI❑N OF N❑NC❑NF❑RMITY, AN ADDITI❑N SHALL NOT CREATE OR <br />EXTEND ANY N❑NC❑NFORMITY IN THE EXISTING BUILDING TO WHICH THE ADDITI❑N IS <br />BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY, <br />MEANS OF EGRESS, OR THE CAPACITY OF MECHANICAL, PLUMBING, OR ELECTRICAL <br />SYSTEMS, <br />ASSUMED S❑IL BEARING CAPACITY TO BE 2000 PSF, S❑IL CAPACITY TO BE VERIFIED <br />BY CONTRACTOR PRI❑R TO C❑NSTRUCTI❑N, INF❑RM ENGINEER OF VARIATI❑NS. <br />F❑❑TINGS TO BE EXCAVATED TO CLEAN S❑IL, FREE OF VEGETATI❑N AND <br />DELETERI❑US MATTER. CONCRETE SHALL BE PLACED ON AN UNDISTURBED BASE. <br />CONCRETE ; <br />MINIMUM C❑MPRESSIVE CONCRETE STRENGTH TO BE 2500 PSI IN 28 DAYS. ALL <br />CONCRETE SHALL BE 'READY MIXED" AND IN ACCORDANCE WITH A,S.T,M. <br />SPECIFICATI❑N C-94. <br />SLAB ON FILL ; <br />INTERI❑R CONCRETE SLABS POURED ON FILL TO BE POURED OVER WATERPROOF <br />MEMBRANES, ALL SLABS TO BE REINF❑RCED WITH 6X6 10/10 WELDED WIRE MESH, <br />LUMBER G <br />1. STORE LUMBER OFF GROUND. KEEP WELL VENTILATED AND COVERED, <br />2. CURRENT EDITI❑N, ASS❑CIATI❑N GRADING RULES GOVERN, <br />3. ALL LUMBER SHALL BEAR GRADE MARK OF AN ASIC BOARD OF REVIEW AGENCY, <br />4. ANY SPECIES ALLOWED UNLESS ❑THERWISE NOTED. <br />5. SIZES ARE N❑MINAL, ACTUAL SIZES SHALL CONFORM TO AMERICAN <br />LUMBER STANDARD PS 20-70, <br />6. M❑ISTURE CONTENT OF LUMBER 2' OR LESS IN THICKNESS SHALL BE <br />19% OR LESS AT THE TIME OF INSTALLATI❑N, <br />STRUCTURAL LUMBER TO HAVE 1120 PSI FIBER STRESS IN CONFORMANCE TO <br />AMERICAN INSTITUTE OF TIMBER C❑NSTRUCTI❑N (AITC) SPECIFICATI❑NS, ALL <br />LUMBER AGAINST MASONRY OR CONCRETE TO BE PRESSURE TREATED, <br />TERMITE TREATING ; <br />S❑IL BELOW STRUCTURE TO BE TERMITE TREATED TO A DISTANCE OF 5'-0' <br />BEYOND THE PERIMETER LINES OF THE BUILDING, <br />ALL STEEL SHALL BE 40 K-SI WITH A MINIMUM CLEAR COVER OF 3' AGAINST <br />S❑IL, AND SHALL HAVE A MINIMUM LAP OF 40 TIMES THE DIAMETER OF THE REBAR, <br />HEADERS SHALL BE DBL, 2X MEMBERS AND LAMINATED W/1/2' PLYWOOD <br />GLUED W/C❑NSTRUCTI❑N ADHESIVE AND NAILED W/#16D COMMONS 16, ❑,C. <br />ALL FASTENERS SHALL COMPLY WITH THE DESIGN LOADS. <br />CONTRACTOR SHALL HAVE MANUFACTURERS SPECIFICATI❑NS (CUT SHEETS) ON SITE <br />AT THE TIME OF INSPECTI❑N, FOR REVIEW BY THE BUILDING INSPECT❑R, <br />TO MEET LOADS AS INDICATED. <br />DOORS & WIND❑WS <br />ENGINEERS NOTES; <br />DESIGN LOADS, <br />A. WIND LOADS, PERT <br />1) RISK CATEGORY 11 - PER (TABLE 1604.5/TABLE 1,5-1) <br />2) EXP, 'B', PER TABLE 1609.4.5/SECTI❑N 26.7,5 <br />3) THE BASIC ULTIMATE DESIGN WIND SPEED, V (ULT) = 130 MPH ult 3 SEC GUST <br />4) N❑MINAL DESIGN WIND SPEED, V (ASD) = 101 MPH asol 3 SEC GUST <br />5) INTERNAL PRESSURE C❑❑FFICIENT, GCPI = 18 ENCLOSED PER TABLE 26.11.1 <br />6) COMP, & CLADDING PRESSURES PER TABLE R301,2(2), UNLESS SPECIFICALLY LABELED ON PLAN <br />B, LIVE LOADS, PER 1607, INCLUSIVE BUT NOT LIMITED TO: <br />1) ROOF LIVE LOAD = 20 PSF <br />2) FLOOR LIVE LOAD = 40 PSF <br />3) UNINHABITTABLE ATTIC LIVE LOAD = 10 PSF <br />4) HABITTABLE ATTIC LIVE LOAD = 20 PSF <br />C, DEAD LOADS, PER 1606, INCLUSIVE BUT NOT LIMITED T❑; <br />1) ROOF DEAD LOAD (TOP CHORD) = 25 PSF <br />2) ROOF DEAD LOAD (BOTTOM CHORD) = 10 PSF <br />3) FLOOR DEAD LOAD = 20 PSF <br />APPLICABLE CODES: <br />7th, EDITI❑N, 2020 FLORIDA BUILDING CODE, BUILDING. PLUMBING, <br />MECHANICAL, FUEL GAS, AND/OR EXISTING BUILDING <br />DATA SUMMARYG <br />BUILDING USE; RESIDENCE GROUP WITH MORE THAN TWO DWELLING UNITS, TYPE R2, <br />C❑NSTRUCTI❑N TYPE V, UNNOTECTED, UNSPRINKLED <br />Residential Group R-2 occupancies containing sleeping units or more than two dwelling <br />units where the occupants are primarily permanent in nature. <br />ALL BEDROOMS REQUIRE AN ❑UTSIDE WIND❑W OR DOOR OPERABLE FROM INSIDE WITH❑UT THE <br />USE OF TOOLS AND PR❑VIDING A CLEAR ❑PENING OF NOT LESS THAN 20" WIDTH, 24' IN HEIGHT <br />& 5,7 SQ. FT, IN AREA, THE BOTTOM OF THE ❑PENING SHALL NOT BE MORE THAN 44' OFF THE <br />FLOOR AND NO PART OF THE ❑PERATING MECHANISM SHALL BE PLACED HIGHER THAN 54, A,F,F. <br />WIND❑WS GREATER THAN 72' ABOVE 72' FINISHED GRADE SHALL HAVE THW WIND❑W SILL HEIGHT <br />GREATER THAN 24' OR PR❑VIDE AN FALL PREVENTIVE DEVICE PER R6162. <br />DOORS & WIND❑WS <br />THE ❑PERATING MECHANISM FOR SINGLE HUNG WIND❑WS SHALL BE AT OR NEAR THE SILL, <br />WIND❑WS INDICATED WITH (E) OR EGRESS MUST BE MANUFACTURED TO CONFORM To THE BLDG, <br />CODE W/ RESPECT TO MIN, EMERGENCY EGRESS REQUIREMENTS PER N.F.P,A. 101 CHAPTER 24, <br />ALL GLASS WITHIN 24' OF ANY DOOR, SLIDING GLASS DOOR, ALL GLAZING AT TUB AND <br />SHOWER ENCLOSURES AND WIND❑WS WITHIN LESS THAN 60' AV❑VE STAIR LANDINGS OR TREADS SHALL BE <br />TEMPERED SAFETY GLASS, SEE ADDITI❑NAL SAFETY GLAZING REQUIREMENTS PER 2010 FBCR R308, <br />SINGLE SWING EXTERI❑R DOORS C❑NNECTING GARAGE TO LIVING AREAS SHALL BE EQUIPPED WITH <br />S❑LID WOOD DOORS NOT LESS THAN 1 3/8' (35 MM) THICKNESS, S❑LID OR HONEYCOMB CORE <br />STEEL DOORS NOT LESS THAN 1 3/8' (35 MM) THICK, OR 20 MINUTE FIRE -RATED D❑❑RS, <br />WHERE MASONRY ❑PENINGS REQUIRE WOOD FRAMING, TO FIT WIND❑W OR DOOR SIZES, PRESSURE <br />TREATED 2x8 STUDS MAY BE SECURED TO THE MASONRY WITH 1/4' DIA, x 3 1/2' TAPC❑N SCREWS, 6- <br />FROM EACH END AND 12' C/C, ADDITI❑NAL FRAMING MEMBERS SHALL BE NAILED To PRI❑R STUD W/ <br />(2) ROWS OF 2d NAILS AT 10' C/C. <br />GYPSUM WALLBOARD <br />PROVIDE -172' NO SAG GYP. BOARD ON ALL CEILINGS, PR❑VIDE 5/8" TYPE 'X' GYP. BP❑ARD ON ALL <br />GARAGE CEILINGS WHERE HABITABLE SPACE EXISTS ABOVE, GARAGE SHALL BE SEPARATED FROM THE <br />RESIDENCE AND IT'S ATTIC AREA BY NO LESS THAN 1/2' GYP, BOARD APPLIED TO THE GARAGE SIDE. <br />HARDIE BACKER TO BE USED AT ALL SHOWER AND TUB L❑CATI❑NS, UP TO 8' A,F.F. <br />N❑N-BEARING INTERI❑R PARTITI❑NS <br />ALL INTERI❑R NON BEARING PARTITI❑NS SHALL BE 2X4 SPF 2 16' ❑,C, MAX, SPACING WITH SINGLE TOP <br />AND BOTTOM PLATE W/ 1/2' GYP. DRYWALL EACH SIDE, <br />FBCR 2020 - COMPONENTS <br />AND CLADDING - EXP. 'B' PER <br />FBCR <br />R301.2 <br />130 <br />Ult - DESIGN WIND PRESSURE FOR WALLS, DOORS & WINDOWS <br />(N❑MINAL) <br />❑MP❑NENT <br />ZONE <br />EFFECTIVE WIND AREA <br />WALL <br />10 SQ. FT. <br />20 SQ, FT, <br />50 SQ. FT, <br />100 <br />SQ, FT. <br />500 SQ. FT. <br />WALL <br />4� <br />+18.2 PSF / -19.8 <br />PSF <br />+17.4 PSF / -19,0 PSF <br />+16.3 PSF / -17.9 PSF <br />+15.5 <br />PSF <br />/ -17.1 PSF <br />+13.6 PSF / -15.1 PSF <br />WALL <br />n <br />+18.2 PSF / -24.4 <br />PSF <br />+17.4 PSF / -22.8 PSF <br />+16.3 PSF / -20,6 PSF <br />+15.5 <br />PSF <br />/ -19.0 PSF <br />+13,6 PSF / -15A PSF <br />NOTE, <br />ALL EXTERI❑R DOORS & WINDOWS ASSEMBLIES SHALL SATISFY THE REQUIREMENTS IN FBC 2020. ALL CONNECTI❑NS TO BUILDING STRUCTURE <br />SHALL HAVE THE CAPACITY TO WITHSTAND THE PRESSURES INDICATED IN THIS SCHEDULE, <br />4'-0' FROM THE BUILDING EDGE GOVERNS FOR ZONE 5. <br />2020 FBCR TABLE R301,2 <br />COMPONENTS AND CLADDING - EXP, 'B' <br />130 Ult - ROOF NET UPLIFT SCHEDULE <br />MAIN ROOF (NOMINAL) <br />ROOF <br />ZONE <br />EFFECTIVE WIND AREA <br />DEGREES <br />10 SQ, FT, <br />20 SQ, FT. <br />50 SO. FT, <br />100 SQ. FT, <br />> 20 TO 27 <br />1 2® <br />+13.6/-26.0 PSF <br />+11.7/-26.0 PSF <br />+10.0/-22,1 PSF <br />+10.0/-19.0 PSF <br />> 20 TO 27 <br />OO 3e <br />+13.6/-41,4 PSF <br />+11,7/-36.3 PSF <br />+10.0/-29,5 PSF <br />+10.0/-24.4 PSF <br />> 20 TO 27 <br />©r <br />+13.6/-49.2 PSF <br />+11.7/-41.4 PSF <br />+10.0/-30.6 PSF <br />+10.0/-30.6 PSF <br />NOTE, <br />ROOFING MATERIALS SHALL BE CONNECTED TO THE ROOF STRUCTURE TO RESIST <br />UPLIFT INDICATED IN THE NET UPLIFT SCHEDULE, <br />4'-0' FROM THE BUILDING EDGE GOVERNS FOR ZONE 3. <br />I HEREBY CERTIFY THAT I HAVE REVIEWED <br />THIS PLAN AND FOUND IT TO BE IN <br />COMPLIANCE WITH ASCE 7-16, & FBC 2020 <br />(7th. EDITION). <br />I ill <br />47 <br />®� \NS E <br />0 56161311 <br />e <br />r� I. 0��L <br />N°' <br />ROOF PITCH 5 ON:2 OF23° <br />�.0••40 <br />°• <br />r <br />REQUIRED ATTIC VENTILATION <br />REQUIRED ATTIC VENTILATION <br />AREA OF ATTIC <br />800 <br />AREA OF ATTIC <br />750 <br />NET FREE VENTILATION AREA REQ'D. <br />1/300 <br />NET FREE VENTILATION AREA REQ'D. <br />1/300 <br />REQ'D. VENTILATION ATTIC <br />800/300 <br />REQ'D. VENTILATION ATTIC <br />750/300 <br />2.66 <br />2.5 <br />VENTILATION AREA x SQ. INCHES PER FOOT (144) <br />384.0 <br />VENTILATION AREA x SQ. INCHES PER FOOT (144) <br />360.0 <br />MIN. REQUIRED VENTILATION IN UPPER PORTION OF ATTIC <br />192 <br />MIN. REQUIRED VENTILATION IN UPPER PORTION OF ATTIC <br />192 <br />OFF RIDGE VENTILATION AREA 115 <br />SQ. INCH PER VENT <br />OFF RIDGE VENTILATION AREA 115 <br />SQ. INCH PER VENT <br />192/115 <br />180/115 <br />TOTAL # OF VENTS REQUIRED <br />1.67 <br />TOTAL # OF VENTS REQUIRED <br />1.57 <br />TOTAL # OF VENTS PROVIDED <br />2 <br />TOTAL # OF VENTS PROVIDED <br />2 <br />SOFFIT VENTILATION AREA 11.736 <br />SQ, INCH PER PER L.F. <br />SOFFIT VENTILATION AREA 11.736 <br />SQ, INCH PER PER L.F. <br />192/11.736 <br />180/11.736 <br />TOTAL LINEAL FT. OF SOFFIT VENTING REQUIRED <br />16.36 <br />TOTAL LINEAL FT. OF SOFFIT VENTING REQUIRED <br />15.34 <br />* AREA OF ATTIC IS THE PERIMETER OF THE HOUSE <br />* AREA OF ATTIC IS THE PERIMETER OF THE HOUSE <br />(EXTERIOR OF WALL TO EXTERIOR OF WALL, NO OVERHANGS <br />INCLUDED) <br />(EXTERIOR OF WALL TO EXTERIOR OF WALL, NO OVERHANGS <br />INCLUDED) <br />APPOYMPRODUMLW <br />Parent Approval <br />Manufacturer <br />Category <br />Subcategory <br />App/Seq # <br />FmidWM i OwNiiiiiiiiiiiis <br />Model Description <br />FL15220.6 <br />Plastico, Inc. <br />Exterior Doors <br />Swinging Ext. Door <br />Opaque Fiber lass Door <br />Entry Door <br />FL15220.5 <br />Plastico, Inc. <br />Exterior Doors <br />Swinging Ext. Door Assemblies <br />_ <br />Opaque Fiberglass Door <br />Glazed Fiberglass Door <br />FL15279-R5 <br />_ <br />Clopay Building Products Compan <br />Exterior Doors <br />Sectional Ext. Door Assemblies <br />_ <br />FL19715 <br />Silverline Bldg. Products <br />Windows <br />Single -Hung <br />V1 Series/70 Series <br />Vinyl <br />FL6067-R7 <br />Silverline Bldg. Products <br />Windows <br />Mullion <br />Aluminum <br />FL16626-1-R3 <br />Tamko Building Products <br />Roofing <br />Underlayments <br />TW Underlayment <br />FL16305.1-R3 <br />Tamko Building Products <br />Roofing <br />Asphalt Shingles <br />Fiberglass Reinforced <br />FL13192.2 <br />James Hardie <br />Panel Walls <br />Siding <br />HardiePlank <br />FL13223.2 <br />James Hardie <br />Panel Walls <br />Siding <br />HardiePanel <br />FL15272 <br />Alside <br />Panel Walls <br />Soffits <br />Aluminum <br />FL11473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Truss Anchors <br />HETA <br />Embedded Truss Anchor <br />FL11473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Truss Anchors <br />META <br />Embedded Truss Anchor <br />FL10456.2-R4 <br />Simp_so_n Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />H2.5 <br />FL10456.10-R4 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />SP1 <br />FL10456.10-R4 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />SP2 <br />_ <br />FL11473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />LSTA12 <br />Strap Ties <br />FL10655.11 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />HUSC <br />Beam Hangers <br />FL13904.6 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />MBHA <br />Beam Hangers <br />AREA CALCULATIONS: <br />LIVING <br />AREA <br />GARAGE <br />PORCH <br />TOTAL <br />UNIT <br />#1 <br />1526 <br />SF <br />293 <br />SF <br />80 <br />SF <br />1899 <br />SF <br />UNIT <br />#2 <br />1500 <br />SF <br />293 <br />SF <br />148 <br />SF <br />1941 <br />SF <br />UNIT <br />#3 , <br />1600 <br />SF <br />293 <br />SF <br />160 <br />SF <br />2053 <br />SF <br />UNIT <br />#4 <br />1500 <br />SF <br />293 <br />SF <br />80 <br />SF <br />1873 <br />SF <br />UNIT <br />#5 <br />1600 <br />SF <br />293 <br />SF <br />160 <br />SF <br />2053 <br />SF <br />UNIT <br />#6 <br />1500 <br />SF <br />293 <br />SF <br />148 <br />SF <br />1941 <br />SF <br />UNIT <br />#7 <br />1600 <br />SF <br />293 <br />SF <br />160 <br />SF <br />2053 <br />SF <br />UNIT <br />#8 <br />1500 <br />SF <br />293 <br />SF <br />148 <br />SF <br />1941 <br />SF <br />UNIT <br />#9 <br />1600 <br />SF <br />293 <br />SF <br />80 <br />SF <br />1973 <br />SF <br />UNIT <br />#10 <br />1500 <br />SF <br />293 <br />SF <br />160 <br />SF <br />1953 <br />SF <br />ALL <br />9��°ltt �yPr c 1"',,p,t a,�GI <br />SI <br />A N I7 TL Nla <br />A' ' '.AIORK SHALL COMPLY WITH ORDINANt <br />GvrI-A CODESAND STANDARDS <br />FAtI� 3 2� REV/F-W OATS A �'� D <br />Y <br />'CITY OF . op c� <br />FIRE F'L�t' „w' <br />A� �. <br />E <br />DRAWING PAGE INDEX <br />DWGS. BF-TH-001 <br />SHT. <br />1 OF 11 <br />- ENGINEERING NOTES <br />SHT. 2 OF <br />11 - FLOOR PLAN <br />SHT. 3 OF 11 - ELEVATIONS <br />SHT. 4 OF 11 <br />- FOUNDATION PLAN <br />SHT. 5 OF 11 - 2ND. FLOOR FRAMING PLAN <br />SHT. 6 OF 11 <br />- ROOF PLAN <br />SHT. 7 OF 11 - ELECTRICAL PLAN <br />SHT. 8 OF 11 <br />- WALL SECTION & DETAILS <br />SHT. 9 OF 11 <br />- SECTIONS & DETAILS <br />SHT. 10 OF <br />11 - SECTIONS THRU UNITS <br />SHT. <br />11 <br />OF <br />11 - <br />ROOF <br />NAILING <br />& <br />BRACING <br />PROFESSIONAL <br />�S <br />ENGINEER OF RECORD <br />David W. Smith, M.S., RE, <br />FLORIDA LICENSE NUMBER 53608 <br />9909 Wallaston Drive <br />Dade City, Fl. 33525 <br />Ph. 813-469-2289 <br />Email: dwsflpeg@gmail.com <br />Plans By: <br />Larry deMontmollin <br />90 Country Club Lane <br />Mulberry, FL 33860 <br />Phone: (863)397-7525 <br />DATE: 2-15-21 <br />DRAWN BY: L.E.D. <br />REVISION: <br />RO 1 <br />RO 2 <br />RO 3 <br />RO 4 <br />DATE: <br />PROJECT ADDRESS: <br />5827 7th. ST. <br />ZEPHYRHILLS, FL. 33542 <br />CONTRACTOR: <br />TOWNHOUSE PLAN <br />ENGINEERING NOTES <br />DWGS, BF-TH-001 <br />SHT.1 OF 11 REV. 0 <br />NOTE 2:2e- FLORIDA APPROVED WINDOWS AND DOORS RATED FOR INDICATED DESIGN PRESSURES AND INSTALLED PER DOOR MANUFACTURERS SPECIFICATIONS. <br />UNDER ROOF 15,426 SF 2930 SF 1324 SF 19,680 SF <br />