1/2" CDX 1 >R in&" OSB ROOF SHEATHING <br />NAILED PER ROOF SHEATHING DETAIL <br />WITH SD 1, 41LS, USE STEEL PLYCLIPS <br />AND GAF JNDERLAYMENT AND GAF <br />SHINGLES RIDGE VENT AS SHOWN ON <br />ELEVATIO 48 <br />SEE TRUSS LAYOUT <br />.00 <br />2X4 WOOD SUB FASCIA WITH <br />ALUMINUM FASCIA, DRIP AND <br />SOFFIT <br />VINYL SINGLE <br />HUNG WINDOWS <br />2X4 02 SPRUCE STUDS AT 16" OC WITH <br />1/2" CDX OR OSB WALL SHEATHING <br />NAILED 3" OC ON ALL PLATES AND <br />4" OC ON VERTICAL STUDS. COVER <br />WITH TYVEK HOUSE WRAP AND SIDING <br />SINGLE 2X4 P.T, BOTTOM PLATE. <br />SECURED WALL TO SLAB WITH 1/2" <br />X 8" ANCHOR BOLTS 24" OC <br />ill <br />•5 VERTICAL RODS PLACED <br />AS SHOWN ON FOUNDATION <br />PLAN <br />ENGINEERED ROOF <br />TRUSSES 24" OC <br />MINIMUM R-30 INSULATION <br />IN ATTIC AREAS <br />DBL 2X4 02 SPRUCE TOP PLATE <br />ALL TOP PLATE SPLICE MUST BE <br />MINIMUM 4'0" NAILED 4" OC WITH <br />12D COMMON NAILS <br />DBL 2X12 "2 PINE WITH ONE <br />LAYER 1/2" PLYWOOD IN CENTER <br />OVER ALL DOOR AND WINDOW <br />OPENINGS <br />SEE ROOF TRUSS PLAN <br />PRE-ENG. TRUSSES <br />1/2" CEILING TYPE <br />GYPSUM BOARD <br />STRIP PORCH CEILING WITH 1X4 <br />02 SPRUCE * 24" OC AND INSTALL <br />BEADED VINYL CEILING <br />; <br />I <br />O I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />; <br />; <br />SEE FLOOR PLAN <br />SIMPSON LCE4 AT ALL CORNER POST <br />AND Afro AND INTERMEDIATE POST TO <br />BEAM, FILL NAIL HOLES WITH IODX1 1/2" <br />NAILS <br />6X6 PT WOOD POST <br />R-13 INSULATION IN WALLS WITH <br />1/2" GYPSUM WALL BOARD <br />TYPICAL 4" CONCRETE SLAB WITH WIRE MESH <br />OR FIBER MESH AND fo MILL VISQUEEN OVER <br />CLEAN COMPACT TERMITE TREATED SOIL <br />BOTTOM OF FOUNDATION <br />MINIMUM 12" BELOW GRADE <br />SIMPSON ABUfob POST BASE WITH 5/8"X6" <br />EXPANSION BOLT IN SLAB AND FILL NAIL <br />HOLES WITH IODXI 1/2" NAILS <br />TYPICAL 8" X Iro" FOOTINGS WITH <br />2 EACH 05 REBAR ON CHAIRS <br />2X4 WOOD WALL DETAIL <br />NOT TO SCALE <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2011 FLORII A BUILDING CODE <br />6TH EDITION AND THE 2011 FLORIDA BUILDING CODE - RESIDENTIAL 6 H EDITION, <br />ARKAY ENGINEERING, INC.: A REGISTERED, LICENSED, FLORIDA PROF :881ONAL STRUCTURAL <br />ENGINEERING COMPANY: HAS APPLIED "RATIONAL ANALYSIS" FOR T1 = STRUCTURAL DESIGN <br />OF THIS STRUCTURE. <br />THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS: <br />SLAB: <br />LIVE LOAD - 50 P.S.F. <br />DEAD LOAD - 10 P.S.F. <br />ROOF: <br />LIVE LOAD (TRUSS TOP CHORD) - 20 P.S.F. <br />DEAD LOAD (TRUSS TOP CHORD) - 10 P.S.F. (15 P.S.F. WHEN T _E ROOFING IS INSTALLED) <br />DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P.S.F. <br />ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 1 P.S.F. <br />WIND: <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 1-10, CHAPTERS 26 TN tU 31. PER 2011 FLORIDA <br />BUILDING CODE, RESIDENTIAL 6TH ADDITION - SECTION R301.2.1.1. AN[ 2011 FLORIDA BUILDING <br />CODE 6TH ADDITION SECTION I6O9 <br />WIND DESIGN ASSUMPTIONS: <br />BUILDING EXPOSURE - B <br />BUILDING RISK CATEGORY - II <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT 4 EXPOSURE ADJUSTMENT <br />COEFFICIENT - 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT - +/- 0.18 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />ALL STRUCTURAL ELEMENTS, EXTERIOR <br />WALLS AND INTERIOR WALLS SHALL BE <br />TYPE V CONSTRUCTION PER FBC 602.5 <br />COMPONENT 4 CLADDING WIND LOADS <br />ALL OTHERCOMPONENT <br />BUILDING <br />ROc F OVERHANG <br />ZONE <br />LOADS <br />LOADS <br />1 <br />N/A <br />+32.3/-35.3 <br />2 <br />-65.1 <br />+32.3/-56.2 <br />3 <br />-110.6 <br />+32.3/-89.0 <br />4 <br />N/A <br />+35.3/-38.2 <br />+35.3/-41.2 <br />5 <br />N/A <br />SOIL BEARING 4 COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEAR 4G CAPACITY OF 2,000 P.S.F. <br />(MINIMUM). THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED 4 COMPACTED SUCH THAT IT r AN SUPPORT A 2,000 P.S.F. <br />FOUNDATION LOADING. <br />ARKAY ENGINEERING, INC.: A REGISTERED, LICENSED, FLORIDA PROF '.SSIONAL STRUCTURAL <br />ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VIS -ING THE CONSTRUCTION SITE <br />NOR PERFORMING ANY SOIL TESTING. <br />ARKAY ENGINEERING, INC. SHALL NOT BE RESPONISIBLE FOR THE SIT - SOILS ABILITY TO SUPPORT <br />THE BUILDING LOADS. <br />FOUNDATIONS 4 SLAB -ON -GRADE: <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATEF IALS WITHIN THE BUILDING AREA. <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL E E COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATIO 1 LOADING. <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAT. ADEQUATELY <br />COMPACTED AND TERMITE POISONED SOIL. <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A '11NIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2,500 P.S.I. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IT ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINA' IM OF 25" <br />FOR 'S REBAR, 30" FOR 06 REBAR 4 35" FOR #1 REBAR. <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 Cc JRSES (AFTER <br />FINAL SITE GRADING). THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO F OURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES < ;eE REQUIRED. <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKf IRS SHALL BE EXPOSED AND <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE R :QUIRED BUILDING SETBACKS. <br />GENERAL NOTES: <br />MASONRY WALLS: <br />CONCRETE MASONRY UNITS SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-90 <br />AND SHALL HAVE A MINIMUM FIM OF 1,500 P.S.I. <br />MORTAR SHALL CONFORM TO ASTM C-210 AND SHALL BE EITHER TYPE M OR S. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR •5 REBAR, 30" FOR 06 REBAR 4 35" FOR 01 REBAR. <br />GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE <br />OF 3/8", PLACED AT AN 8 TO Il INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH <br />OF 2,500 P.S.I. (WHEN TESTED PER ASTM C-1019). <br />PROVIDE CLEAN -OUT OPENINGS (12 SQ. IN.) IN CELLS CONTAINING SPLICED REINFORCEMENT, WHEN <br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT. <br />TIMBER MATERIALS: <br />ALL TIMBER MATERIALS SHALL BE AS FOLLOWS: <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND APPROVED <br />PRIOR TO REQUESTING THE FRAMING INSPECTION. <br />IF DESIRED, EQUIVALENT CONNECTORS MADE BY ANOTHER SUPPLIER MAY BE USED IN PLACE OF THE <br />"USP" OR "SIMPSON" CONNECTORS SHOWN. <br />ALL LIMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED <br />MATERIALS <br />INTERIOR STUD WALLS TO BE OF 2 X 4 02 SPRIJCE OR BETTER WITH SINGLE 2 X 4 P.T. <br />PINE BOTTOM PLATE AND SINGLE 2 X 4 02 SPRUCE TOP PLATE WITH STUDS SPACED <br />MAXIMUM 24" OC. WALLS TO HAVE In" GYPSUM BOARD EACH SIDE, WITH WALLS AT <br />GARAGE TO HAVE MINIMUM R-II INSULATION <br />SOIL TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE <br />SHALL STATE <br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." <br />IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />A OV O NOT APPLY. A SIGN FIVE Y CONTRACT FROM THE ISSUE <br />8 E D PL SIGNED E YEAR <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE <br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM <br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL. <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />BACKFILLING 4 COMPACTION ARE COMPLETE <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED <br />(INCLUDING ANY BOXED OR FORMED AREAS) - <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE 4 DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT. <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />SHALL BE REQUIRED <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR S01_ TREATMENT <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION). ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />BUILDING SIDEWALLS <br />PORCH SLAB <br />6X(o PT POST 4 5EAM DETAIL <br />NOT TO SCALE <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />TRUSSES: <br />IF THE CONTRACTOR, TRUSS MANUFACTURER OR ANY OTHER DESIGN PROFESSIONALS REVISE THE <br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS ARKAY ENGINEERING, INC. IS <br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN <br />INTENT PRIOR TO COMMENCEMENT OF THE PROJECT. <br />EXTERIOR WINDOWS 4 DOOR ASSEMBLIES: <br />ALL EXTERIOR WINDOW 4 GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br />101/152 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO <br />TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. <br />INSTALL ALL WINDOW 4 DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS <br />TO ACHEIvE THE DESIGN PRESSURES SPECIFIED. <br />ELECTRICAL, PLUMBING 4 MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 411.003(2XI) OF THE FLORIDA ADMINISTRATIVE CODE. ELECTRICAL, <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREO <br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN (WITHIN 6 FEET OF SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GFI" CIRCUIT. <br />ALL ELECTRICAL OUTLETS IN BEDROOMS SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />"AFL" CIRCUIT. <br />SAFETY GLAZING: <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: <br />(1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR <br />ASSEMBLIES. <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN 60 INCHES ABOVE THE DRAIN INLET. <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT. <br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />PLANE OF THE GLAZING. <br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308 FOR ADDITIONAL AREAS <br />THAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING. <br />ATTIC ACCESS: <br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXCEEDING 30 SQ. FT. AND HAVING MINIMUM <br />30 INCHES OF VERTICAL HEIGHT. ROUGH -FRAMED OPENING NOT TO BE LESS THAN 22 X 30 INCHES. <br />WHEN MECHANICAL EQUIPMENT IS LOCATED IN THE ATTIC, IT SHALL BE INSTALLED IN ACCORDANCE <br />WITH THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION M1305.1.3 <br />GARAGE: <br />NO OPENINGS SHALL BE PERMITTED FROM A GARAGE INTO A SLEEPING ROOM. OTHER OPENINGS <br />BETWEEN THE GARAGE AND RESIDENCE SHALL HAVE A DOOR (MIN. 1 3/8" THICK), OF SOLID WOOD, <br />SOLID OR HONEYCOMB CORE STEEL, OR 20-MINUTE FIRE -RATED WITH SELF CLOSING HINGES. <br />WALLS SEPARATING THE GARAGE AND RESIDENCE SHALL HAVE MIN. I/2" GYPSUM BOARD <br />APPLIED TO THE GARAGE SIDE. THE CEILING SHALL HAVE MIN. 1/2" GYPSUM BOARD APPLIED <br />TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED BY ALL <br />HABITABLE ROOMS ABOVE WITH MIN. 5/8" 'TYPE-X' GYPSUM BOARD IN COMPLIANCE WITH THE <br />FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R309 <br />I <br />; <br />; <br />; <br />I <br />; <br />I <br />; <br />I <br />I <br />; <br />; <br />; <br />I <br />I <br />I <br />I <br />I <br />1 1/2" V.T.R. <br />I <br />I <br />I <br />; <br />; <br />; <br />; <br />; <br />; <br />; <br />I <br />c4 <br />I <br />; <br />I <br />�o <br />n <br />; <br />; <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />; <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />; <br />I <br />1 <br />I <br />I <br />I <br />N I <br />I <br />; <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />05 VERTICAL RODS FROM FOOTINGS <br />BELOW TO TOP OF STEM WALL. PLACE <br />AT ALL CORNERS AND SPACED <br />MAXIMUM 4' 0" OC <br />30, 8" <br />I I I I <br />I I 1 <br />I I I <br />PORCH SLAB 4" BELOW I <br />I <br />I <br />I <br />HOUSE FINISH FLOOR I I I <br />I I I I <br />I I I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />jlr <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />1 1/2" V.T.R. <br />I I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I I <br />I <br />I <br />I <br />I <br />bF7 <br />I <br />I <br />I <br />I <br />I <br />I I <br />I I <br />I I <br />I 2" V.T. I <br />I I <br />I I <br />I I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I I <br />I <br />I I <br />b c I I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I I <br />I I <br />I I <br />I I <br />jf <br />1 <br />I <br />1 <br />I <br />1 <br />I I <br />I I <br />I I <br />I I <br />; <br />I I <br />I <br />1 <br />1 <br />I <br />I - <br />I tt <br />- <br />I I <br />I <br />1 <br />1 <br />Q <br />I O I <br />F <br />I � <br />I I <br />I <br />1 1/2" V.T.R. <br />I I <br />I <br />F + <br />1 d) <br />I I <br />I I <br />I <br />I <br />I I <br />I I <br />WASHER <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I I <br />I I <br />I I <br />I I <br />14' 4" <br />I <br />I I <br />I I <br />I I <br />I I <br />i I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />1 <br />I <br />I <br />1 <br />I <br />I <br />I <br />I O I <br />I <br />I O I <br />I <br />I <br />LL <br />I <br />w <br />.4 <br />IV <br />4 <br />I a I <br />I <br />� O <br />I N <br />I I <br />I I <br />I I <br />I I <br />I <br />I <br />1 <br />I <br />I I <br />I I <br />I I <br />GARAGE SLAB 4" BELOW <br />I <br />1 <br />I <br />HOUSE FINISH FLOOR <br />I I <br />I I <br />I I <br />I <br />I <br />1 <br />I I <br />I I <br />I------- -------- -- - ------------- ------I <br />1 <br />1 <br />I I I I <br />I I I I <br />I I I I <br />PORCH SLAB 4" BELOW <br />I <br />I <br />1 <br />' HOUSE FINISH FLOOR I <br />I I I I <br />I I I I <br />I I I I <br />' <br />I <br />I <br />I <br />I I <br />I I <br />------------------------------------ i------------- -- - ------------- --------- <br />I <br />I <br />14' 8" <br />I <br />1&1 O" <br />01 <br />30' 8" <br />FOUNDATION 4 SANITARY PLAIN 1/411 = I, OBI <br />ARKAY ENGINEERING INC. <br />STRUCTURAL ENGINEERSA <br />RICHARD L. /X)P.EFLORIDA <br />LICENBER 31294b <br />I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER 16, SECTION I6O9 OF THE <br />FLORIDA BUILDING CODE 2011 6TH EDITION AND ASCE 1-10 <br />FOR 13c3 MPH WIND ZONE RISK CATEGORY II AND THE ENTIRE <br />2011 BUILDING CODE RESIDENTIAL 6TH EDITION <br />C7 <br />U <br />CV <br />Lo <br />ch <br />Z <br />M <br />Q <br />'— <br />0Fr <br />0 <br />1` <br />O o <br />J CV <br />U- <br />z <br />cn <br />CV <br />U Lo <br />z W <br />I-1 <br />XMX <br />_UI Q Q <br />co <br />UJ U' <br />fm(wr <br />W <br />A <br />Z d N <br />m <br />00 1 <br />m CA Lo <br />w <br />W <br />m U_ <br />LL <br />u- <br />Z) O <br />N <br />co <br />- <br />ccn <br />rr <br />�\0N <br />� m <br />t0 • <br />O�c U <br />m *' <br />cn\00th <br />cq go tj <br />z <br />5-xIN <br />fa <br />U_ 4 <br />c-0 <br />Z m <br />m �u- <br />_Z <br />ill0OoLa <br />V <br />-u d <br />T <br />0toc� <br />IY <br />-10 <br />0 ��_ <br />L <br />1 <br />Lu %o <br />ui 0 <br />Cd <br />0 •' <br />O_d)(Y- <br />a <br />� <br />I <br />O <br />z <br />ED <br />Q <br />O <br />LIVING <br />1382 <br />GARAGE <br />3-10 <br />FRONT <br />PORCH <br />80 <br />REAR <br />PORCH <br />'12 <br />TOTAL 1904 <br />2OF4 <br />ARKAY 17791 <br />