My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5901 13th St
Zephyrhills
>
Building Department
>
Building Plans
>
5901 13th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 2:41:48 PM
Creation date
2/18/2025 4:26:12 PM
Metadata
Fields
Template:
Building Plans
Street #
5901
Location
13th St
Contractor
Bobby Hilton Construction
Building Plans - Permit #
20205
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
------------------- <br />I <br />I <br />�I <br />I <br />�I <br />12X�6X1 <br />15O CFM <br />° <br />o <br />a <br />0 <br />o � <br />8X4X1 SX4X6 <br />90 CFM Zz� cli 65 CFM <br />c-c <br />I I <br />I I <br />I I <br />I I <br />I � I <br />F- <br />SX4X4 <br />50 CFM <br />L- - - - - - - - - J <br />O <br />E,-�-T <br />IG STAIRS <br />AIR , >NDLER INSTALLED IN <br />ATTIC AREA MUST COMPLY <br />WITH 3C 201l MECHANICAL <br />COD' 6TH ADDITION <br />L _ J I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />12X6X1 <br />150 CFM <br />12X6�X1 <br />150 CFM <br />R/A <br />2OX20--------- ------ --- <br />R.A.G. O O------- i <br />I <br />0 <br />12X�6X1 ° <br />150 CFM <br />I <br />I I I <br />I I , <br />i I , <br />I <br />-- - - - - - - - - - - ---- <br />I I <br />1�1 <br />I I <br />I I <br />I I <br />I I <br />I I <br />.I. <br />i I <br />-- _— -- -- -5,f -- -- -- _— -- -- -- -- -- -- -L41 <br />HYAC PLAN 1/411 = 11 o11 <br />GENERAL LOADS <br />TYPE OF LOAD <br />LIGHTING LOAD 1904 SQ FT X 3VA 5112 <br />SMALL APPLIANCE LOAD 2 CIRCUITS X 1500VA 3000 <br />LAUNDRY LOAD I CIRCUITS X 1500VA 1500 <br />TOTAL VA 10212 <br />LOAD <br />LIGHTING, SMALL APPLIANCE, <br />LAUNDRY FIRST 3000VA X 100 TOTAL 3000 VA <br />LIGHTING, SMALL APPLIANCE <br />LAUNDRY REMAINING 1212 VA X 35 9b TOTAL 2525 VA <br />TOTAL 5525 VA <br />LARGE APPLIANCE LOADS <br />ELECTRIC RANGE NOT OVER 12 KVA <br />8000 VA <br />CLOTHES DRYER <br />5500 VA <br />WATER HEATER <br />4500 VA <br />HVAC HEAT <br />6000 VA <br />TOTAL 24000 VA <br />TOTAL VA 29525 VA <br />CONVERT VA TO AMPS <br />29525 DIVIDED BY 240 VOLTS - 124 AMPS <br />ELECTRICAL LEGEND <br />220 v <br />G.F.I. <br />110 V <br />GROUND FAULT <br />RECEPTACLE <br />CEILING FAN <br />SWITCH <br />® <br />IIOV 50 CFM'S <br />110 v <br />BATH FAN <br />CEILING <br />WP <br />110 V <br />SMOKE <br />FAN W/ LIGHT <br />WATERPROOF <br />DETECTOR <br />OUTLET <br />O RECESS CAN LIGHT <br />IIOV LIGHT <br />OC <br />CARBON <br />MONOXIDE <br />CAN BE CEILING <br />UNIT <br />ELECTRICAL PANEL <br />OR WALL (TYP) <br />G.D.O. � <br />FLUORESCENT WALL SCONCE G.D.D <br />FIXTURE `I-{' G-b-15" <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "CFI" CIRCUIT <br />ALL REMAINING OUTLETS IN HOME TO WIRED INTO A ARC -FAULT INTERRUPTER "Am" CIRCUIT <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS <br />CARBON MONOXIDE ALARM MUST BE INSTALL WITHIN 10'O" OF EACH ROOM USED FOR SLEEPING PURPOSES <br />WHEN BUILDING HAS A FOSSIL FUEL BURNING HEATER OR APPLIANCE, A FIREPLACE OR AN ATTACHED <br />GARAGE. <br />GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C. <br />TYPICAL ELECTRICAL RISER DIAGRAM <br />3 -4/0 THWN CU FEEDERS <br />WITH 04 GROUND <br />METER SOCKET <br />02 CU DRIVEN GROUND <br />RODS 2 EACH 8'0" APART <br />SINGLE PHASE <br />BREAKER PANEL <br />WITH MAIN <br />150 AMP <br />2" PIPE <br />2" PIPE <br />3 - 4/0 THWN CU FEEDERS <br />CONCRETE ENCASED "UFER" <br />ELECTRODE REQUIRED PER <br />CURRENT N.E.G. AND MUST <br />BE INSPECTED PRIOR TO <br />CONCRETE PLACEMENT <br />ELECTRICAL PLAN 11411 - 11 oil <br />ARKAY ENGINEERING <br />STRUCTURAL ENGINEE <br />16 <br />�> tJ RIGHARD L. KIDD P.E. <br />FLORIDA LIGEN NUMBER 31296 <br />I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE <br />FLORIDA BUILDING CODE 2011 6TH EDITION AND ASCE 1-10 <br />FOR 139 MPH WIND ZONE RISK CATEGORY II AND THE ENTIRE <br />2011 BUILDING CODE RESIDENTIAL 6TH EDITION <br />M <br />u <br />N <br />z <br />M <br />M <br />Q <br />O O <br />J N <br />cn <br />ILL I-- <br />z <br />CO <br />_ N <br />ZU Lf) <br />M <br />W <br />Fo Q <br />W <br />Z N <br />Q <br />IL <br />0 <br />m N <br />00 , <br />m rn to <br />M <br />W <br />2 U_ <br />C,6 U- <br />LL <br />O <br />N <br />M <br />r� <br />�vor <br />m m <br />tp • <br />m � <br />amD�Otl <br />mcD4U <br />z <br />QO <br />0� <br />Lu <br />z� <br />v <br />u' <br />to <br />o o�Lu <br />T <br />W`9 ILL <br />11l 4) <br />ill � gyp' U <br />(� d) Ily <br />Lf <br />O <br />z <br />Q <br />O <br />LIVING <br />1382 <br />GARAGE <br />310 <br />FRONT <br />PORCH <br />80 <br />REAR <br />PORCH <br />12 <br />TOTAL 1904 <br />PG <br />4OF4 <br />ARKAY 17791 <br />
The URL can be used to link to this page
Your browser does not support the video tag.