<br />ENGINEER'S NOTES
<br />ALL WORK TO BE DONE ACC❑RDING TO FLORIDA BUILDING CODES.
<br />BUILDINGS OR STRUCTURES SHALL CONFORM TO
<br />2017 FBC 6TH, EDITI❑N BUILDING.
<br />AN ADDITI❑N TO A BUILDING OR STRUCTURE SHALL COMPLY WITH THE FBC'S AS
<br />FOR NEW C❑NSTRUCTI❑N WITH❑UT REQUIRING THE EXISTING BUILDING OR STRUCTURE
<br />TO COMPLY WITH ANY REQUIREMENTS OF THOSE CODES OR OF THESE PR❑VISI❑NS
<br />EXCEPT AS REQUIRED BY CHAPTER 10. WHERE AN ADDITI❑N IMPACTS THE EXISTING
<br />BUILDING ❑R STRUCTURE, THAT P❑RTI❑N SHALL COMPLY WITH THIS CODE.
<br />CREATI❑N OR EXTENSI❑N OF NONCONFORMITY, AN ADDITI❑N SHALL NOT CREATE OR
<br />EXTEND ANY N❑NC❑NF❑RMITY IN THE EXISTING BUILDING TO WHICH THE ADDITI❑N IS
<br />BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY,
<br />MEANS OF EGRESS, OR THE CAPACITY OF MECHANICAL, PLUMBING, OR ELECTRICAL
<br />SYSTEMS.
<br />ASSUMED S❑IL BEARING CAPACITY TO BE 2000 PSF. S❑IL CAPACITY TO BE VERIFIED
<br />BY CONTRACTOR PRI❑R TO C❑NSTRUCTI❑N, INF❑RM ENGINEER OF VARIATI❑NS.
<br />F❑❑TINGS TO BE EXCAVATED TO CLEAN S❑IL, FREE OF VEGETATI❑N AND
<br />DELETERI❑US MATTER, CONCRETE SHALL BE PLACED ON AN UNDISTURBED BASE,
<br />CONCRETE 1
<br />MINIMUM C❑MPRESSIVE CONCRETE STRENGTH TO BE 2500 PSI IN 28 DAYS, ALL
<br />CONCRETE SHALL BE 'READY MIXED' AND IN ACCORDANCE WITH A,S,T,M,
<br />SPECIFICATI❑N C-94,
<br />SLAB ON FILL ;
<br />INTERI❑R CONCRETE SLABS POURED ON FILL TO BE POURED OVER WATERPROOF
<br />MEMBRANES. ALL SLABS TO BE REINF❑RCED WITH 6X6 10/10 WELDED WIRE MESH,
<br />LUMBER
<br />1, STORE LUMBER OFF GROUND, KEEP WELL VENTILATED AND COVERED.
<br />2, CURRENT EDITI❑N, ASS❑CIATI❑N GRADING RULES GOVERN,
<br />3. ALL LUMBER SHALL BEAR GRADE MARK OF AN ASIC BOARD OF REVIEW AGENCY.
<br />4, ANY SPECIES ALLOWED UNLESS ❑THERWISE NOTED.
<br />5. SIZES ARE N❑MINAL, ACTUAL SIZES SHALL CONFORM TO AMERICAN
<br />LUMBER STANDARD PS 20-70.
<br />6, M❑ISTURE CONTENT OF LUMBER 2' OR LESS IN THICKNESS SHALL BE
<br />19% OR LESS AT THE TIME OF INSTALLATI❑N,
<br />STRUCTURAL LUMBER TO HAVE 1120 PSI FIBER STRESS IN CONFORMANCE TO
<br />AMERICAN INSTITUTE OF TIMBER C❑NSTRUCTI❑N (AITC) SPECIFICATI❑NS, ALL
<br />LUMBER AGAINST MASONRY OR CONCRETE TO BE PRESSURE TREATED.
<br />TERMITE TREATING
<br />S❑IL BELOW STRUCTURE TO BE TERMITE TREATED TO A DISTANCE OF 5'-0'
<br />BEYOND THE PERIMETER LINES OF THE BUILDING.
<br />ALL STEEL SHALL BE 40 KSI WITH A MINIMUM CLEAR COVER OF 3' AGAINST
<br />S❑IL, AND SHALL HAVE A MINIMUM LAP OF 40 TIMES THE DIAMETER OF THE REBAR,
<br />HEADERS SHALL BE DBL, 2X MEMBERS AND LAMINATED W/1/2' PLYWOOD
<br />GLUED W/C❑NSTRUCTI❑N ADHESIVE AND NAILED W/#16D COMMONS 16' ❑,C,
<br />ALL FASTENERS SHALL COMPLY WITH THE DESIGN LOADS,
<br />CONTRACTOR SHALL HAVE MANUFACTURERS SPECIFICATI❑NS (CUT SHEETS) ON SITE
<br />AT THE TIME OF INSPECTI❑N, FOR REVIEW BY THE BUILDING INSPECT❑R,
<br />TO MEET LOADS AS INDICATED.
<br />DOORS & WIND❑WS
<br />DESIGN LOADS:
<br />A. WIND LOADS, PER;
<br />1) RISK CATEGORY 11 - PER (TABLE 1604,5/TABLE 1,5-1)
<br />2) EXR 'B', PER TABLE 1609,4.5/SECTI❑N 26.7.5
<br />3) THE BASIC ULTIMATE DESIGN WIND SPEED, V (ULT) = 140 MPH Wt 3 SEC GUST
<br />4) N❑MINAL DESIGN WIND SPEED, V (ASD) = 110 MPH asd 3 SEC GUST
<br />5) INTERNAL PRESSURE COOFFICIENT, GCPI = .18 ENCLOSED PER TABLE 26.11.1
<br />6) COMP. P. CLADDING PRESSURES PER TABLE R301.2(2), UNLESS SPECIFICALLY LABELED ON PLAN
<br />B. LIVE LOADS, PER 1607, INCLUSIVE BUT NOT LIMITED TO:
<br />1) ROOF LIVE LOAD = 20 PSF
<br />2) FLOOR LIVE LOAD = 40 PSF
<br />3) UNINHABITTABLE ATTIC LIVE LOAD = 10 PSF
<br />4) HABITTABLE ATTIC LIVE LOAD = 20 PSF
<br />C, DEAD LOADS, PER 1606, INCLUSIVE BUT NOT LIMITED T01
<br />1) ROOF DEAD LOAD (TOP CHORD) = 25 PSF
<br />2) ROOF DEAD LOAD (BOTTOM CHORD) = 10 PSF
<br />3) FLOOR DEAD LOAD = 20 PSF
<br />APPLICABLE CODES:
<br />6TH, EDITI❑N, 2017 FLORIDA BUILDING CODE, BUILDING, PLUMBING,
<br />MECHANICAL, FUEL GAS, AND/OR EXISTING BUILDING
<br />6TH, EDITI❑N, 2017 FLORIDA FIRE PREVENTI❑N CODE (IF APPLICABLE)
<br />2014 NATI❑NAL ELECTRICAL CODE
<br />DATA SUMMARY;
<br />BUILDING USE: RESIDENCE GROUP WITH MORE THAN TWO DWELLING UNITS, TYPE R2,
<br />C❑NSTRUCTI❑N TYPE V, UNPROTECTED, UNSPRINKLED
<br />Residential Group R-2 occupancies containing sleeping units or more than two dwelling
<br />units where the occupants are primarily permanent In nature,
<br />ALL BEDROOMS REQUIRE AN ❑UTSIDE WIND❑W OR DOOR OPERABLE FROM INSIDE WITH❑UT THE
<br />USE OF TOOLS AND PR❑VIDING A CLEAR ❑PENING OF NOT LESS THAN 20' WIDTH, 24' IN HEIGHT
<br />& 5,7 SQ. FT. IN AREA. THE BOTTOM OF THE ❑PENING SHALL NOT BE MORE THAN 44' OFF THE
<br />FLOOR AND NO PART OF THE ❑PERATING MECHANISM SHALL BE PLACED HIGHER THAN 54, A.F.F,
<br />WIND❑WS GREATER THAN 72' ABOVE 72' FINISHED GRADE SHALL HAVE THW WIND❑W SILL HEIGHT
<br />GREATER THAN 24' OR PR❑VIDE AN FALL PREVENTIVE DEVICE PER R6162,
<br />DOORS & WIND❑WS
<br />THE ❑PERATING MECHANISM FOR SINGLE HUNG WIND❑WS SHALL BE AT OR NEAR THE SILL,
<br />WIND❑WS INDICATED WITH (E) OR EGRESS MUST BE MANUFACTURED TO CONFORM To THE BLDG.
<br />CODE W/ RESPECT TO MIN. EMERGENCY EGRESS REQUIREMENTS PER N,F,P,A, 101 CHAPTER 24.
<br />ALL GLASS WITHIN 24' OF ANY DOOR, SLIDING GLASS DOOR, ALL GLAZING AT TUB AND
<br />SHOWER ENCLOSURES AND WIND❑WS WITHIN LESS THAN 60' AV❑VE STAIR LANDINGS OR TREADS SHALL BE
<br />TEMPERED SAFETY GLASS, SEE ADDITI❑NAL SAFETY GLAZING REQUIREMENTS PER 2010 FBCR R308,
<br />SINGLE SWING EXTERI❑R DOORS C❑NNECTING GARAGE TO LIVING AREAS SHALL BE EQUIPPED WITH
<br />S❑LID WOOD DOORS NOT LESS THAN 1 3/8' (35 MM) THICKNESS, S❑LID OR HONEYCOMB CORE
<br />STEEL DOORS NOT LESS THAN 1 3/8' (35 MM) THICK, OR 20 MINUTE FIRE -RATED DOORS,
<br />WHERE MASONRY ❑PENINGS REQUIRE WOOD FRAMING, TO FIT WIND❑W OR DOOR SIZES, PRESSURE
<br />TREATED 2x8 STUDS MAY BE SECURED TO THE MASONRY WITH 1/4' DIA, x 3 1/2' TAPC❑N SCREWS, 6'
<br />FROM EACH END AND 12' C/C, ADDITI❑NAL FRAMING MEMBERS SHALL BE NAILED To PRI❑R STUD W/
<br />(2) ROWS OF 2d NAILS AT 10' C/C.
<br />GYPSUM WALLBOARD
<br />PR❑VIDE 1/2' NO SAG GYP, BOARD ON ALL CEILINGS, PR❑VIDE 5/8' TYPE 'X' GYP. BP❑ARD ON ALL
<br />GARAGE CEILINGS WHERE HABITABLE SPACE EXISTS ABOVE. GARAGE SHALL BE SEPARATED FROM THE
<br />RESIDENCE AND IT'S ATTIC AREA BY NO LESS THAN 1/2' GYP, BOARD APPLIED TO THE GARAGE SIDE.
<br />HARDIE BACKER TO BE USED AT ALL SHOWER AND TUB L❑CATI❑NS, UP TO 8' A.F.F.
<br />N❑N-BEARING INTERI❑R PARTITI❑NS
<br />ALL INTERI❑R NON BEARING PARTITI❑NS SHALL BE 2X4 SPF 2 16' ❑,C, MAX. SPACING WITH SINGLE TOP
<br />AND BOTTOM PLATE W/ 1/2' GYP. DRYWALL EACH SIDE.
<br />Parent A royal
<br />�p
<br />FL15220.6
<br />_FL15220.5
<br />FL15279-R5
<br />- -- - -
<br />FL19715
<br />- - --
<br />Manufacturer -
<br />�Plastico, Inc. -
<br />- noon �
<br />Plastico, Inc.
<br />Clo a Buildin Products Compan
<br />Clopay -g - - -- y- - _
<br />Silverhne Bldg. Products - _
<br />-
<br />FLORIDA APPROVED PRODUCTS LIST
<br />Category Subcategory-
<br />Swinging Ext. Door
<br />-- - --
<br />Exterior Doors -rswinging
<br />Exterior Doors Ext. Door Assemblies
<br />Exterior Doors Sectional Ext. Door Assemblies
<br />- - - -
<br />- Windows JSingle-Hung
<br />### Product Model # or Name
<br />Opaque Fiberglass Door
<br />jOpaque Fiberglass Door
<br />V1 Series/70 Series
<br />Model Description J
<br />Entry Door �I
<br />Glazed Fiberglass Door
<br />Vinyl
<br />--
<br />FL6067-R7 Silverline Bldg. Products WindowsMullion Aluminum
<br />-- -- -- - - - - - - - - noon -
<br />FL16626-1-R3 Tamko Building Products RoofingUnderlaymentsW Underla ent
<br />-- - - -- - - -- -- -ro-i _ - --- --- -
<br />Roofing f Asphalt Shingles Fiberglass Reinforced
<br />FL16305.1-R3 Tamko Building_ Products � _
<br />-
<br />i
<br />FL15272 Alside -- _--- Panel Walls Soffits Aluminum
<br />- -- - - - - _.. -- -- - -noon-- Embedded Truss Anchor
<br />FL11473-R2 Simpson Strong -Tie Co. Structural Components Truss Anchors HETA
<br />FL11473-R2 Simpson Strong -Tie Co. Structural Components Truss Anchors META Embedded Truss Anchor
<br />- - - --
<br />FL10456.2 R4 Simpson Strong -Tie Co. Structural Components Wood Connectors Anchors H2.5
<br />FL10456.10-R4 I Simpson Strong -Tie Co. Structural Components Wood Connectors Anchors- SP1
<br />PStrong-Tie- P - - --- noon-- - -- - - -
<br />_- --- --- Com S P 2
<br />FL10456.10-R4 - Simpson Co. Structural orients Wood Connectors Anchors -
<br />- - _-_ Wood Connectors Anchors --T - T - -
<br />FL11473-R2 Simpson Strong -Tie Co. Structural Components LSTA12 - _Ties
<br />P g p � - _ --- - -
<br />FL10655.11 Simpson Strong -Tie Co. Structural Components Wood Connectors Anchors HUSC Beam Hangers
<br />- - --- - - - noon --- --- - - -�
<br />FL13904.6 Simpson Strong -Tie Co. Structural Components Wood Connectors Anchors MBHA Beam Hangers
<br />1
<br />i;- -- -- __- - - --
<br />g
<br />---noon- _ -- . -
<br />- --.__.-----_---
<br />--
<br />NOTE 2:278- FLORIDA APPROVED WINDOWS AND DOORS RATED FOR INDICATED DESIGN PRESSURES AND INSTALLED PER DOOR MANUFACTURERS SPECIFICATIONS.
<br />M51P�NIIPL PLAN CH�CKI.15f M� FI.OVIPA 13UII.91% COn� 6TH. �PIION ( 2011)
<br />5I/ ► a..#65 Lmim NPICAIW. 'r 41i
<br />/ 1W/' r / i / 1i •.
<br />5. PW= PWUfM f WM IWACf N aWa5FOR WWORK
<br />i / • G .• • '
<br />6. 50IR COWAM1011 WAL5 WM FRm : / , ija :i / i /' . I / r, . ! . fir.
<br />WVW5, ANP MAXJMUM OMN ML 5PPCINC4 INIACKW, (FPC-W51MN% 011.7, Z
<br />iiI' II I/I' I'/ ► 1111401WIP&M I /PWICIM
<br />FX-M5119%%
<br />i %M r Ir AkV CAIM MINIM I /r (FOCAM51111MUM R. 4. IN 57)
<br />7. mom 01I / C&WIM 'r 01.
<br />• ' i/ I / /' / i ! /'
<br />FIM • • • / /' 002b, 'fi •
<br />M516N OMNIN6 M55M5
<br />rNC O%19 PUIL19IN6 WOW "6''
<br />96
<br />1900Iz/ WOW
<br />1 15S[9
<br />ZONE
<br />M551,T
<br />MR fARX 001.2
<br />NOMIN& 519
<br />AAA
<br />A
<br />5068 V9.
<br />4
<br />20.2
<br />22
<br />20 5f
<br />P
<br />2868 W.
<br />4
<br />2112
<br />22
<br />10 5F
<br />C
<br />2668 V9.
<br />4
<br />212
<br />22
<br />10 5F
<br />n
<br />16010 OW
<br />5
<br />18,0
<br />22
<br />100 5f
<br />'75 63
<br />2-25 5H
<br />4
<br />20,2
<br />22
<br />20 51'
<br />F
<br />1560 5/ 8
<br />2-22 5H
<br />4
<br />20.2
<br />22
<br />20 5F
<br />G
<br />3lx63
<br />25 5H
<br />4
<br />21.2
<br />22
<br />10 5F
<br />H
<br />8
<br />24 5H
<br />4
<br />21.2
<br />22
<br />10 5P
<br />i
<br />5/ 8
<br />24 5H
<br />5
<br />2112
<br />28
<br />10 5F
<br />K
<br />31x38 3/ 8
<br />23 5H
<br />4
<br />21.2
<br />22
<br />10 5f
<br />L
<br />32/ 2 5H
<br />4
<br />21.2
<br />22
<br />10 5F
<br />M
<br />15x63
<br />2-25 5H
<br />5
<br />20.2
<br />22
<br />20 5F
<br />ZOW 5 PA%L9 ON 4' ROM COIZNM
<br />ALL WORK SHALL COMPLY WITH PReVAILING
<br />CODES FLORIDA BUILDING CODE,
<br />NATIONAL ELECTRIC CODE,
<br />AND THE CITY OF ZEPHYRHILLS
<br />ORDINANCES
<br />REQUIRED ATTIC VENTILATION
<br />AREA OF ATTIC
<br />2535
<br />NET FREE VENTILATION AREA REQ'D.
<br />1/300
<br />REQ'D. VENTILATION ATTIC
<br />2535/300
<br />8.45
<br />VENTILATION AREA x SQ. INCHES PER FOOT (144)
<br />1216.8
<br />MIN. REQUIRED VENTILATION IN UPPER PORTION OF ATTIC
<br />608.4
<br />OFF RIDGE VENTILATION AREA 115
<br />SQ. INCH PER VENT
<br />608.4/115
<br />TOTAL # OF VENTS REQUIRED
<br />5.29
<br />TOTAL # OF VENTS PROVIDED
<br />6
<br />SOFFIT VENTILATION AREA 11.736
<br />SQ, INCH PER PER L.F.
<br />608.4/11.736
<br />TOTAL LINEAL FT. OF SOFFIT VENTING REQUIRED
<br />51.84
<br />* AREA OF ATTIC IS THE PERIMETER OF THE HOUSE
<br />(EXTERIOR OF WALL TO EXTERIOR OF WALL, NO OVERHANGS
<br />INCLUDED)
<br />AREA CALCULATIONS:
<br />1809
<br />SF
<br />- LIVING AREA
<br />500
<br />SF
<br />- GARAGE AREA
<br />85
<br />SF
<br />- REAR PORCH AREA
<br />96
<br />SF
<br />- FRONT PORCH AREA
<br />45
<br />SF
<br />- STORAGE AREA
<br />12535 SF - UNDER ROOF I
<br />DRAWING PAGE INDEX
<br />5920-A1
<br />-ENGINEERING NOTES
<br />5920-A2
<br />-FLOOR PLAN
<br />5920-A3
<br />-ELEVATIONS
<br />5920-A4
<br />-FOUNDATION
<br />PLAN
<br />5920-A5 -ROOF PLAN
<br />5920-A6 -ELECTRICAL PLAN
<br />5920-S1 -WALL SECTION &DETAILS
<br />5920-S2 -ROOF NAILING
<br />5920-S3 - ROOF BRACING DETAILS
<br />I HEREBY CERTIFY THAT I HAVE REVIEWED
<br />THIS PLAN AND FOUND IT TO BE IN
<br />COMPLIANCE WITH ASCE 7-10, & FBC 2017
<br />(6TH. EDITION).
<br />PROFESSIONAL ENGINEER SEAL
<br />ENGINEER OF RECORD
<br />David W. Smith P.E.
<br />FLORIDA LICBNSB NUMBER: 53608
<br />Plans By:
<br />Larry deMontmollin
<br />90 Country Club Lane
<br />Mulberry, FL 33860
<br />Phone: (863)397-7525
<br />DATE: 09-03-19
<br />DRAWN BY: L.E.D.
<br />REVISION: DATE:
<br />R01
<br />RO 2
<br />RO 3
<br />I�
<br />PROJECT ADDRESS:
<br />592012TH. ST.
<br />ZEPHYRHILLS, FL. 33542
<br />CONTRACTOR:
<br />BUTTERFIELD INVESTMENTS
<br />HOUSE PLAN
<br />ENGINEERING NOTES
<br />DWG, 5920-Al
<br />REve 0