Laserfiche WebLink
I <br />---T---------T--- ---1--------------- <br />I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I i I I <br />I I I I <br />I I I I <br />I I I I <br />I 1 I I <br />I I I I <br />I I I I <br />I I I I <br />O I I I O l O <br />I I I I <br />I I I I <br />I I I I <br />I I Q I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I 0 I <br />I I <br />I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />- - - - - - - - - - - - - - - - - - - 1 - - - - - - - - - -I- - - <br />S� O �O <br />a <br />GABLE ROOFS <br />100 < 0 < 300 <br />FBCR 2017 - COMPONENTS AND CLADDING - EXP, 'B' PER <br />FBCR <br />R3012 <br />140 <br />ULt - DESIGN WIND <br />PRESSURE FOR WALLS, DOORS & WINDOWS <br />(NOMINAL) <br />COMPONENT <br />ZONE <br />EFFECTIVE WIND AREA <br />WALL <br />10 SQ. FT. <br />20 SQ. <br />FT. <br />50 SQ. FT, <br />100 <br />SQ, FT, <br />500 SQ, FT. <br />WALL <br />® <br />+21.2 PSF / -22.0 <br />PSF <br />+20.2 PSF / <br />-22.0 PSF <br />+19,0 PSF / -20.0 PSF <br />+18.0 <br />PSF <br />/ -19.0 PSF <br />+15.8 PSF / -17.0 PSF <br />WALL <br />5� <br />+21.2 PSF / -28.0 <br />PSF <br />+20.2 PSF / <br />-26.0 PSF <br />+19.0 PSF / -23.0 PSF <br />+18.0 <br />PSF <br />/ -22.0 PSF <br />+15.8 PSF / -17.0 PSF <br />NOTE, <br />ALL EXTERI❑R DOORS & WINDOWS ASSEMBLIES SHALL SATISFY THE REQUIREMENTS IN FBC 2017, ALL C❑NNECTIONS TO BUILDING STRUCTURE <br />SHALL HAVE THE CAPACITY TO WITHSTAND THE PRESSURES INDICATED IN THIS SCHEDULE. <br />4'-0' FROM THE BUILDING EDGE GOVERNS FOR ZONE 5, <br />COMPONENTS AND CLADDING - EXP. 'B' <br />140 Ult - ROOF NET UPLIFT SCHEDULE <br />MAIN ROOF (NOMINAL) <br />ROOF <br />ZONE <br />EFFECTIVE WIND AREA <br />DEGREES <br />10 SQ. FT, <br />20 SQ, FT, <br />50 SQ. FT, <br />100 SQ. FT, <br />> 7 TO 27 <br />[� <br />+12.2/-19.0 PSF <br />+111/-18.0 PSF <br />+10.0/-18.0 PSF <br />+10,0/-17.0 PSF <br />> 7 TO 27 <br />O2 <br />+12.2/-33.0 PSF <br />+111/-31.0 PSF <br />+10.0/-27.0 PSF <br />+10.0/-24.0 PSF <br />> 7 TO 27 <br />(� <br />+12.2/-49.0 PSF <br />+11.1/-46.0 PSF <br />+10.0/-42.0 PSF <br />+10.0/-39.0 PSF <br />NOTE, <br />ROOFING MATERIALS SHALL BE CONNECTED TO THE ROOF STRUCTURE TO RESIST <br />UPLIFT INDICATED IN THE NET UPLIFT SCHEDULE. <br />4'-0' FROM THE BUILDING EDGE GOVERNS FOR ZONE 3. <br />2017 FBCR TABLE R301.2 <br />COMPONENTS AND CLADDING - EXP, 'B' <br />140 Ult - ROOF NET UPLIFT SCHEDULE <br />MAIN ROOF (NOMINAL) <br />ROOF <br />ZONE <br />EFFECTIVE WIND AREA <br />DEGREES <br />10 SQ. FT. <br />20 SQ, FT, <br />50 SQ. FT. <br />100 SQ. FT. <br />> 27 TO 45 <br />1 <br />+19.4/-21.0 PSF <br />+18.8/-20.0 PSF <br />+18.1/-18.0 PSF <br />+17.6/-17.0 PSF <br />> 27 TO 45 <br />O2 <br />+19.4/-24.0 PSF <br />+18.8/-23.0 PSF <br />+18.1/-22.0 PSF <br />+17.6/-21.0 PSF <br />> 27 TO 45 <br />3 <br />1 +19.4/-24.0 PSF <br />+18.8/-23.0 PSF <br />+18A/-22.0 PSF <br />+17.6/-21.0 PSF <br />NOTE, <br />ROOFING MATERIALS SHALL BE CONNECTED TO THE ROOF STRUCTURE TO RESIST <br />UPLIFT INDICATED IN THE NET UPLIFT SCHEDULE, <br />4'-0' FROM THE BUILDING EDGE GOVERNS FOR ZONE 3. <br />ROOF PITCH 5 ON 12 <br />w <br />WADS <br />COMPONENTS & CLADDING PRESSURE ZONES <br />NOTE "a" = 4 FEET IN ALL CASES <br />—1 n11 rr) ')1 n1 n)) <br />PRELIMINARY ROOF PLAN <br />FOLLOW TRUSS SUBCONTRACTOR PLANS <br />ROOF PLAN <br />1 /411=1'-0" <br />LATERAL LOADS <br />Design Wind Velocity: 140 mph <br />Risk Category:11 <br />Wind Exposure Category: B <br />Internal Pressure Coefficents: 0.18/-0.18 (Enclosed) <br />UPLIFT PER TABLE 802.11 <br />SPAN = 33'-0" <br />TRUSS SPACING = 24" <br />U=765 # PER CONN. <br />HETA20 = U =1810# O <br />SIMPSON META20 <br />SIMPSON HETA20 <br />) SIMPSON MGT <br />SIMPSON HUS 26 <br />SIMPSON H1 <br />SIMPSON H3 <br />0 SEE GABLE END DETAIL <br />SIMPSON LSTA12 <br />I HEREBY CERTIFY THAT I HAVE REVIEWED <br />THIS PLAN AND FOUND IT TO BE IN <br />COMPLIANCE WITH ASCE 7-10, & FBC 2017 <br />(6TIL EDITION). <br />►ir <br />• <br />. <br />® 608 <br />Is *4 <br />S00 <br />TATE <br />e <br />NA L e® <br />j®or ►�,` <br />PROFESSIONAL ENGINEER SEAL <br />ENGINEER OF RECORD <br />David W. Smith P.E. <br />FLORIDA LICBNSE NUMBER: 53608 <br />Plans By: <br />Larry deMontinollin <br />90 Country Club Lane <br />Mulberry, FL 33860 <br />Phone: (863)397-7525 <br />DATE: 09-03-19 <br />DRAWN BY: L.E.D. <br />RBVISION: DATE: <br />R01 <br />RO 2 <br />RO 3 <br />RO 4 <br />PROTECT ADDRESS: <br />592012TH. ST. <br />ZEPHYRHILLS, FL. 33542 <br />CONTRACTOR: <br />BUTTERFIELD INVESTMENTS <br />HOUSE PLAN <br />ROOF PLAN <br />VERIFY ROOF PLANTH <br />TRUSS MANUF. DRAWINGS DWG, 5920-A5 <br />AND CALCULATIONS. <br />REV. 0 <br />