Laserfiche WebLink
R <br />\�\ PROPOSED PLAN - SERVICE YARD <br />1/4" = 1'-0" <br />KEYED NOTES <br />10 CONTRACTOR SHALL PROVIDE AND INSTALL AN EXHAUST AIR LOUVER EQUAL <br />TO A RUSKIN EME6325D, WITH A MINIMUM FREE AREA OF 0.26 SF, UNDER THE <br />EAVE OF THE ROOF. THE LOUVER SHALL BE MOUNTED IN ACCORDANCE WITH <br />THE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS AND AS <br />APPROVED BY THE LISTING OF THE LOUVER. <br />Q CONTRACTOR SHALL PROVIDE AND INSTALL AN OUTSIDE AIR INTAKE LOUVER <br />EQUAL TO A RUSKIN EME6325D, WITH A MINIMUM FREE AREA OF 0.42 SF, UNDER <br />THE EAVE OF THE ROOF. THE LOUVER SHALL BE MOUNTED IN ACCORDANCE <br />WITH THE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS AND AS <br />-APPROVED BY-INE LISTINC-QF THE LOLLVER. <br />CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF T4E EXISTING ROOF <br />INSULATION. IF THE ROOF INSULATION IS ENTIRELY ABOVE OR ADHERES TO <br />THE BOTTOM OF THE ROOF DECK THE CONTRACTOR SHALL INSTALL THE AHU <br />WITH NO ADDITIONAL REQUIREMENTS. IF THE INSULATION IS INSTALLED ON <br />THE TOP OF THE CEILING, THE GENERAL CONTRACTOR SHALL BUILD AN <br />INSULATED BOX SURROUNDING THE AHU. THE BOX SHALL BE OF PROPER SIZE <br />TO ALLOW FOR A PERSON TO SERVICE THE UNIT, SHALL INCLUDE REQUIRED <br />CLEARANCES, PROPER LIGHTING FOR SERVICE, AND STRUCTURAL SUPPORT <br />FOR THE UNIT, BOX, AND SERVICER. THE MECHANICAL CONTRACTOR SHALL <br />PROVIDE A 4" SPIN -IN FITTING WITH A VOLUME DMAPER ON THE SUPPLY DUCT <br />LOCATED WITHIN THE BOX, BALANCE TO 50 CFM. ROUTE INSULATED <br />CONDENSATE DRAIN PIPING TO EXTERIOR OF BUILDING. TERMINATE <br />INDIRECTLY A MINIMUM OF THREE INCHES ABOVE GRASSY AREA. PIPE ROUTING <br />SHALL NOT BE VISIBLE FROM WINDOW. PAINT WEATHER -EXPOSED PVC PIPING <br />WITH ONE COAT OF UV RESISTANT PAINT. CONTRACTOR SHALL PLACE AHU <br />ABOVE LAY IN CEILINGS OR PROVIDE AN APP.RORIATELY SIZED ACCESS PANEL. <br />CONTRACTOR SHALL PROVIDE AN STALL AN EXHAUST AI}iCOUVER E L <br />TO A RUSKIN EMED6325D, WITH A MINIMUM FREE AREA OF 0.19 SF, UNDER THE <br />EAVE OF THE ROOF. THE LOUVER SHALL BE MOUNTED IN ACCORDANCE WITH <br />THE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS AND AS <br />APPROVED BY THE LISTING OF THE LOUVER. <br />O5 CONTRACTOR SHALL ROUTE REFRIGERANT PIPING UNDERGROUND AND RISE <br />UP INSIDE OF BUILDING. SEE DETAIL ON SHEET M402. <br />GENERAL NOTES <br />1. CONTRACTOR SHALL INSTALL MECHANICAL EQUIPMENT IN ACCORDANCE WITH ALL <br />STATE AND LOCAL CODES, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL <br />TRANSITIONS, FITTINGS, ELBOWS, DUCTWORK, PIING, SUPPORTS, ETC., NECESSARY <br />FOR A PROPER INSTALLATION AND OPERATION OF NEW HVAC SYSTEM. <br />2. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. <br />3. ALL BRANCH DUCTS TO AIR DEVICES SHALL BE PROVIDED WITH A VOLUME DAMPER <br />IN THE BRANCH CONNECTION UNLESS NOTED OTHERWISE. ALL ROUND BRANCH <br />DUCT CONNECTIONS SHALL BE PROVIDED WITH CONICAL SPIN -IN FITTING WITH <br />INTEGRAL VOLUME DAMPER. <br />I� <br />O <br />f��JIT�®IN �1 1FT IAV <br />■ <br />design styles <br />architecture <br />70 E Columbus lave <br />TOO, Florida 33605 <br />813 241 6700 f 813 247 3757 <br />designs#ylesarch tecture.com <br />AA0003393 <br />5935 7th Street <br />Zephyrhills, FL 33542 <br />Prepared for <br />JB Realty Partners <br />In Association with: <br />genesis <br />engineering <br />(Eg en e s t group, Ilc. <br />s 2601 cattleman rd., suite 501 <br />sarasota, fl 34232 <br />w .geneng.net coa#29304 project#18-189FL <br />Professional Seal <br />Ilillll!///f�/ <br />/v fl <br />* No. 551 0 •• <br />*5f ill M <br />STATE OF <br />i. OR 1 0 <br />No. Issue Description Date <br />1 PERMIT AND BID SET 12/10/2018 <br />No. Revision Description Date <br />1 PERMIT COMMENTS 3/8/19 <br />Drawn By: CTF Checked By: RMH <br />Project Number: 18190 <br />Sheet Title <br />PROPOSED <br />PLAN <br />Original drawing is 24 x 36 Do not <br />scale contents of drawing <br />Sheet Number <br />PROPOSED PLAN <br />;a, <br />1/4" = 1'-0" <br />M102 <br />