A/C <br />DICONNECT <br />WP <br />GFI <br />PORCH <br />-------------- <br />ELECTRICAL <br />PLAN (ELEVATIONS A & B <br />1 /411 = 1'-0" <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />ELECTRICAL NOTES- <br />1 . GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS -WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST S FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT. 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to Tooter steel <br />OR <br />4 Bare attached to footer steel <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />APR 0 8 2023 <br />Virl,ijal Review Assist. Inc. <br />=arts review coonpieted and approvet <br />ri cornpkance vvith tine 2020 FBC 7th Edition <br />,,; (ter,,e Ahs,B If" iahr uX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />io <br />Ik <br />SWITCH 0 <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET ih <br />TRIM c <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�F TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />- SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />-o DIMMER SWITCH AT 36" <br />-{J PUSH-BUTTON DOORBELL <br />-A - CLG MNT LT FIXTURE <br />-- CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />TT NOTE: <br />C, 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />C USEDIF <br />50W PAR30 NFL 6" WHITE BAFFLE APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />(� 50W PAR20 NFL 4" MINI ROUND RECESS <br />io 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />Cos SMOKE DETECTOR <br />C SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />c D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />24:;;? 24" VANITY LIGHTING <br />36 =,;:g 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />Mr <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />�j DOUBLE FLOOD LIGHT W/ COVERS AND <br />U 150W PAR 38 FL <br />0 INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />00 CHIMES (DELETE W/ INTERCOM) <br />= MASTER STATION <br />Nii;J ELEC PANEL <br />VACUM OUTLET AT 12" <br />WAI CEILING RETURN AIR <br />A/C REGISTER <br />OT THERMOSTAT <br />In SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />— <br />W <br />� <br />L C �O q U <br />' 0 c � 0 <br />(N <br />N "i 2 <br />V -0-0— 2 M <br />2 M <br />2o <br />OAS oQ <br />w Q.� <br />7W <br />V <br />L cO E " o� <br />^ CO <br />a a <br />W <br />q LU <br />ouj vi w0~ <br />l�-< oQ� <br />o��O�¢w002,0 <br />Q <br />ax¢( z:�LQ <br />cyW�wooWg�zw <br />oOZ1 zz ¢�a_¢owO�p< <br />Q <br />ILL <br />-¢o=9Q�z <br />0Q <br />0ZQ<¢ <br />Q O <br />LL w <br />O <br />Z N <br />OW <br />F_ <br />cM O <br />Q U) M � <br />2u)z �'ti <br />< W < Lq <br />H' of M <br />Z U <br />W <br />W <br />JC:) <br />n <br />(0 <br />N <br />� <br />{ <br />I <br />I <br />I <br />O <br />O <br />O <br />N <br />O <br />N <br />CO) <br />N <br />N <br />M <br />C)C)N <br />o <br />n <br />o <br />� <br />� <br />N <br />o <br />� <br />' <br />Z <br />O <br />w <br />N <br />o <br />O <br />N <br />o <br />M <br />O <br />4 <br />o <br />L6 <br />I <br />I <br />I <br />i <br />co!/1 <br />zl­- <br />vJ <br />QZ <br />w <br />O <br />♦.J <br />O <br />W <br />U <br />co_o <br />(jVo) <br />O <br />=)z5; <br />O�o <br />Q <br />C:) <br />Z <br />I- <br />a_a <br />L J <br />= <br />w Q <br />LD <br />m~LU <br />z O <br />■ ■CLg <br />C�Q <br />U <br />gwx <br />w� <br />Z <br />az <br />�Z <br />Z <br />OU <br />C <br />12 <br />W <br />z <br />Z <br />z <br />w <br />W04 <br />0 <br />LAST PLOT DATE <br />N <br />■ <br />March 23, 2023 <br />Z� <br />J <br />ELECTRICAL PLAN <br />