Laserfiche WebLink
(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />PLAN <br />2x6 / 2x8 WALL <br />BEYOND SEE PLAN <br />FOR HEADER (2) 2x HEADER TO SIT <br />CONNECTION I FLUSH TO THE OUTSIDE <br />SEE PLAN FOR SIZE <br />2x DEAD WOOD @ MID <br />POINT w/ (3) 12d <br />TONEAILS SPACED <br />V EVENLY <br />HEADER FLUSH TO OUTSIDE OPTION <br />-OUBLE 2x TOP <br />2x BLOCKING @ EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />(2) 2x HEADER <br />PER PLAN <br />PLATE <br />N <br />VARIES 2x BOTTOM PLATE W/ (1) 1Od @ 8" <br />O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAILri <br />SCALE: N.T.S. SL� <br />12 <br />SEE ELEV. �(TYp) <br />SIMPSON SP2 w/ (12) 10d <br />NAILS AT EACH STUD <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE II <br />PLATE W/ (2)16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 w/ (10) 1Od <br />NAILS AT EACH STUD <br />2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX i_// <br />W/8"EMBEDMENT <br />::/= = <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90A HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED, <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERAL NOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2x4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />�— SINGLE 2x CONT. TOP <br />PLATE W/ (2) 12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />(3) 1 Od TOENAILS T&B <br />AS REQ'D <br />—2x BLOCKING @ MID <br />POINT EVERY OTHER <br />STUD W/ (3) 1 Od NAIL <br />BLOCKING (TYP.) <br />PROOF TRUSS <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />LSEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />1/2" MINIMUM CEMENT FINISH <br />STANDARD 3" DIA. TEE <br />THREADED 3" DIA. EXTENSION - <br />SCREW OFF CAP (3" DIA.) <br />FOR CLEAN -OUT <br />MIN. EXTENSION FROM <br />EXTERIOR FACE OF BLOCK <br />WALL IS 1 1/2" MAXIMUM <br />EXTENSION FROM EXTERIOR <br />FACE OF BLOCK WALL IS 21/4" <br />VENT OR 2ND FLOOR <br />TYPICAL C.M.U. WALL <br />3/4" FURRING STRIPS <br />1/2" GYPSUM BOARD <br />W/ DRYWALL SCREWS <br />@ 8" O.C. OR 4d <br />DRYWALL NAILS <br />WALL CLEAN -OUT K"A <br />SCALE: N.T.S. S4 <br />REFER TO WINDOW PRODUCT APPROVAL <br />SHEETS FOR INSTALLATION INFORMATION BY <br />MANUFACTURER. <br />TYPICAL SECTION THRU WINDOW B <br />S4 <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT J <br />■■�!'��!i <br />�■E�i� <br />_4I0 <br />• • <br />.•. •• � • • <br />� _ <br />• • • • • <br />_'Ili! <br />In <br />= <br />■■ill <br />III■■ <br />�lill <br />IIII� <br />■■III <br />MEN <br />�IIlI <br />IIII� <br />■■III. <br />lii■■ <br />MIIII <br />IIlI� <br />■■lii <br />MEN <br />�'IIII <br />IIII� <br />NOTES: <br />0 FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />O VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />® SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />O OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WID-rH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />WIDTH OF OPENING VARIES 4" <br />FORM CONCRETE INSET TO <br />CREATE A SOLID BASE FOR <br />1l2"X9 1l2" PLYWOOD <br />BLOCK WALL ABOVE. <br />SCRAP MATERIAL <br />J <br />J <br />- <br />\0NE" <br />w <br />> <br />0 <br />FORM CREATES CONCRETE RECESS TO <br />2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />MOUNTING BASE SHOWN <br />IN POSITION <br />GARAGE ENTRY FORM DETAIL <br />2x6 MOUNTING BASE <br />SCALE: N.T.S. <br />�8x8x16 C.M.U. <br />GARAGE DOOR TRACK MOUNTING BRACKET <br />GARAGE DOOR ROLLER <br />GARAGE DOOR TRACK <br />CONNECTION ASSEMBLY <br />., GARAGE FLOOR <br />xx <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. a <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B EE <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />7 5/8" 8" 7 5/8" 8" 7 5/8" 8" <br />SOLID AREAS ARE ❑ SOLID AREAS ARE <br />❑ STEEL AND GROUT ❑ ❑ STEEL AND GROUT <br />INTERIOR FULL 8 8 16 BLOCK <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />12 <br />TRUSSES @ 24" O/C <br />(nP•) SEE ELEV. <br />UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM <br />C. 926 APPLY 3 LAYERS W/ <br />TOTAL THICKNESS 7/8" OVER <br />METAL LATH. FIRST 2 LAYERS <br />3/8" THICK EACH. 3RD LAYER <br />1/8" THICK OVER WATER <br />RESISTIVE BARRIER <br />❑ ❑ ❑ x x SIMPSONSP2 w/ 10d NAILAT <br />WALL NAILS AT EACH STUD <br />Ct- DOOR OPENING DOOR OPENING DOOR OPENING --Ct 1/2" EXTERIOR GRADE SHEATHING CRICKET AS <br />FASTENED TO TRUSSES WITH 8d REQUIRED <br />COMMON WIRE NAILS @ 4" O/C <br />EXTERIOR ❑ ❑ BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING (T .) <br />WALL ❑ El ❑ O/C FIELD <br />❑ ❑ 2X4 PT STUDS @ 16" O.C. <br />(2) 2X4 PT STUDS UNDER HIP <br />1ST COURSE 2ND COURSE 3RD COURSE CARRIER/GIRDER TRUSS <br />MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COURSE MUST BE BONDED TO THE SIMPSON HETA20 w/ (8) 1Odxl 1/2" <br />COURSE BELOW. EVERY THIRD (3RD) COURSE THE 11" DOORJAMB WALL IS TO BE NAILS AT EA. TRUSS VERTICAL WEB <br />WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. (24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />IN KO BLOCK AT EA. STUD - MAIN SPAN <br />MASONRY LAYOUT D MOISTURE BARRIER ROOF TRUSS <br />UPLIFT CONNECTOR <br />SCALE: N.T.S. S4 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. - -- (SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />Ef <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 90° HOOK IN K.O. BLOCK <br />VERTICAL JAM ALT. KNEEWALL ABOVE MASONRY WALL DETAIL <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8"ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. SCALE: N.T.S. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />WALL PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />d a ' THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />° d DOOR STOP PSPN516Z w/ (12) 16d NAILS <br />e. d MOLDING <br />TOP 2 ROWS 10d @ 3' O.C. (14 <br />2 x 6 P.T. /� GARAGE SPLICE NAILS TOTAL) EA. SIDE OF <br />/ DOOR4,9,SPLICE STAGGERED <br />J-BOLT <br />TRACK <br />BRACKET <br />SFFA�O <br />N <br />2x CRIPPLES @ <br />16" O.C. W/ (2) 12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ ( <br />1 Od x 1 1/2" AT EA <br />STUD (USE SP6 F <br />2x6 WALL, USE S <br />FOR 2x8 WALL) <br />1Od NAILS @ 8" <br />O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />W/MOUNTING ANGLE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. �S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />SIZE <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1'-4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1)LSTA30 <br />4'- 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />6) (2) 2x HEADER SEE PLAN <br />INTERIOR HEADER: <br />P8R S4 • (1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER . EXTERIOR HEADERS: <br />ONLY (1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6) 1Od x 1 1/2" EACH <br />SIDE <br />2x STUDS TYP. <br />OO SIMPSON HTT4 TYP. <br />Op OR U.N.O. SEE N/S4 <br />HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />INTERIOR WALL HEADER DETAIL rQ <br />SCALE: N.T.S. S4 <br />SIMPSON SIMPSON <br />/8"xl0" "J" BOLT <br />@ 24" O.C. MAX. <br />MIN. (2) PER <br />BOTTOM PLATE <br />SECTION <br />2 <br />P <br />11 <br />0. <br />SIMPSON SP4 <br />O <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />RECESS <br />LINTEL <br />a <br />r <br />• 1Od @ 8" O/C <br />ATTACH ALL J <br />EXTERIOR STUDS <br />W/ 4 16d TOENAILS <br />T076PPLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL M <br />SCALE: N.T.S. S4 <br />F= 2240 LBS <br />SIMPSON C <br />SIMPSON SP4 SP2 <br />�-NAILED <br />INTO <br />TRANSOM <br />TRANSOM FRAMING <br />FRAMING <br />C P.T. <br />SEE SECTION AA/S1 <br />ATE <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />SIMPSON <br />SP1 <br />SIMPSON <br />SIMPSON <br />RECESS <br />LINTEL <br />SP4 <br />SP4 <br />SIMPSON <br />SP4 <br />d <br />SIMPSON <br />SP2 <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 SIMPSON <br />SIMPSON SP4 <br />SP4 <br />FBLOCKING <br />RUSS BOTTOM CHORD OR 2x4 <br />W/ 2-16d TOE NAILS <br />EACH END <br />w <br />U <br />�z a <br />2x TOP PLATE N <br />2-16d NAILS @ 24" O.C. OR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2x STUD @ 24" <br />O.C. MAX. <br />PROVIDE P.A.F. NAILS OR <br />2x P.T. PLATE <br />EQUAL @ 12" O.C. <br />STAGGERED FROM BOT. <br />SEE A/S3 FOR <br />PLATE TO CONCRETE <br />REINF. INFO. <br />TYPICAL INTERIOR NON — <br />BEARING WOOD FRAME WALL j <br />SCALE: N.T.S. S4 <br />SIMPSON SP4 <br />2X TOP PLATE <br />OVERLAPPING <br />—1 Od NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />SPF) <br />(3075# SPF) <br />3 (4565# SPF) <br />3 (5645# SPF) <br />3 (6970# SPF) <br />)S (9335# SPF) <br />IN. 8" <br />PDXIED A.T.R. <br />2 & NUT <br />'OXIED A.T.R. <br />2&NUT <br />OXIED A.T.R. <br />i&NUT <br />ROOF TRUSS ABOVE <br />/- 2X BLOCKING <br />d I I <br />a 2X8 P.T. BOTTOM P TE C <br />B <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. <br />C (MIN. (2) PER BOTTOM PLATE) <br />-(2) 16d TOE NAILS <br />EA. BLOCKING <br />- 2X8 WALL ABOVE <br />ENTRY <br />"1K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />MASONRY WALL <br />SIMPSON C <br />SP4 <br />10d NAILS @ 4" 1 Od NAILS @ 6" O.C. <br />STAGGERED A STAGGERED <br />TRANSOM FRAMING <br />o o BEYOND. <br />PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" L PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES o E SHEATHING <br />& 8" O/C FIELD <br />S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12) 1 Od NAILS MASONRY <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />d <br />2X8 P.T. BOTTOM <br />PLATE <br />5/8 x10 J BOLTS @ 24 O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />PLATE) <br />ALTERNATE: <br />5/8" DIA, ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY R <br />SCALE: N.T.S. S4 <br />APR 0 8 2023 <br />H <br />a� <br />k-hial'eview Assist, Inc. <br />!a^s ""'mew corn.pleted and approved <br />j iii°?Il�S Ce !till iiie 2020 F8C 7th Edition; <br />liy Debra /;rise VIanr PX2360 <br />5� <br />M <br />- -- ,-.A <br />t j <br />N <br />N <br />M <br />tr <br />•� <br />00 <br />LO <br />t .. ' ?� <br />a <br />Lu <br />Of <br />0 <br />z <br />a <br />L. � o 0 <br />M c y <br />=01cc <br />} v) M <br />N nU -0 N � <br />E - t co <br />O <br />W O S oa:8 ooQ <br />U "o 0) a <br />a <br />0 �� <br />L 2 <br />Lu <br />Ld w <br />�W H W W O <br />a z <br />L.L U <br />Q <br />¢ <br />oX� �'0,JOa QaJ zLLLO-z2OZaaOn <br />LU fr0�0z0X00mz U <br />Lu <br />O O <br />Z�_U-uj <br />_j0a>zYOZzoa <br />lW�CY <br />L<_Ju <br />< <br />OQ o o¢Q a <br />0 U. <br />O <br />O <br />Z W <br />0 I-_ <br />U) ::) t` <br />z <br />0 M O <br />QU)Mu� <br />U) U- 't <br />In- C'M <br />�a2T_ <br />O <br />ZUI�— <br />w <br />W <br />-1Q <br />0 <br />E <br />O <br />O <br />N <br />o <br />O <br />N <br />0 <br />N <br />o <br />M <br />N <br />O <br />NQ <br />C') <br />co <br />O <br />C> <br />o <br />—0N <br />— <br />N <br />o <br />I <br />� <br />�— <br />N <br />o <br />1 <br />1 <br />' <br />Z <br />O <br />NW <br />Lo <br />� <br />O <br />— <br />o <br />N <br />0 <br />Cl) <br />0 <br />ITIn <br />o <br />I <br />i <br />I <br />I <br />W (� <br />z Z <br />Qz <br />C)zw <br />� <br />O <br />W <br />U <br />w0_O <br />UU� <br />LO <br />0 <br />oz>_ <br />0�< <br />Q <br />C <br />Z <br />= <br />��a <br />Of <br />Ln <br />V <br />T-I <br />00 <br />Z = <br />■ <br />w <br />O <br /><�0 <br />zwo <br />CD <br />Z <br />f, <br />v <br />gZ� <br />L- <br />• <br />az <br />U <br />m <br />Z <br />z <br />z <br />LLJ <br />ui <br />O <br />LAST PLOT DATE <br />0 <br />. . <br />z O <br />STRUCTURAL <br />DETAILS <br />