Laserfiche WebLink
SHINGLE ROOF <br />7/8" STUCCO <br />OVER PLYWOO <br />11/4"THKx6" <br />STUCCO BAND <br />SIMILAR <br />5/8" STUCCO <br />OVER CMU ---�_ <br />12 <br />5f <br />FRONT ELEVATION A <br />1 /4„ = 1'-01 <br />1 <br />REAR ELEVATION A <br />1 /411 = 1'-011 <br />STUCCO CASING BEAD WITH <br />WEEP HOLES OVER FLASHING <br />ELEV AT 8'-0" <br />T.O.M. <br />NIGLE ROOF <br />ELEV AT 84" <br />T.O.M. <br />5/8" STUCCO <br />OVER CMU <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />OVERHANG DETAIL <br />PUAll = 1 I_r)1f <br />FINISH <br />LEVATION <br />SHEATHING <br />FACTURED <br />TRUSS <br />,RIP EDGE <br />INUM WRAP <br />INUM SOFFIT <br />01012901II&Aa»C7 <br />ELEVATION <br />ROOF SHEATHING <br />•e' <br />i <br />MANUFACTURED <br />ROOFTRUSS <br />METAL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />PER ELEVATION <br />ALUMINUM <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />OVERHANG DETAIL <br />6 <br />'11a 1_7 <br />= 1 <br />ELEV AT 8'-0" <br />T.O.M. <br />T-0" <br />5/8" STUCCO <br />OVER CMU <br />0o <br />(o <br />ELEV AT 0'-0" <br />— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1ST FLOOR FF <br />3 RIGHT ELEVATION A <br />1 Aff= 11-011 <br />r <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />LEFT ELEVATION A <br />1 /411 = 1'-01' <br />12 <br />5 <br />_L <br />_ ELEV AT 8'-0" <br />T.O.M. <br />15/8" STUCCO <br />OVER CMU <br />v <br />r` <br />3'-0" <br />00 <br />ib <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />FOAM BAND <br />5/8" STUCCO <br />FINISH <br />NOTE: <br />FOAM TO BE USED ONLY WHEN <br />REQUIRED BY COMMUNITY <br />SPECS. IF NOT, DETAIL TO BE <br />BUILT W/ STUCCO <br />VARIES PER OPENING we <br />I I 2" THICK <br />1" 2" <br />1-1/2" THICK <br />N 3 1 /2" <br />°' <br />�J <br />io <br />3" THICK <br />VARIES PER OPENING <br />BAND 8 ELaEVATION DETAILS <br />71 CMU COLUMN DETAIL <br />713/4 = 11-011 <br />4" 10" <br />N 4" <br />2 LB EPS 2" 1" <br />BRACKET DETAIL <br />9 a = 1 1-ni, <br />CV <br />M <br />co <br />M <br />N <br />(V M <br />co <br />CV <br />M <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS- <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />APR 0 8 2023 ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />a�. <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />a EGRESS NOTE: <br />¢ a,. EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />Virtual Review Assist, Tnc FLOOR LINE OF THAT PARTICULAR ROOM <br />Flans Review completed and approved <br />rcr compliance vsd. tile L 120 FP', 7t!i [ditior <br />y Pehra Anne t,lanr Yy%:+_'P <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />✓`t1',M <br />- <br />co <br />N <br />o <br />N <br />N <br />N <br />co <br />LO <br />00 <br />LLO <br />W <br />O <br />w <br />z <br />Q <br />W <br />L <br />L c ' u <br />N 2 <br />:) 9 <br />O <br />m Q <br />u�� <br />.N <br />t <br />V w Q� <br />W <br />L E00 <br />a <br />V, <br />LLJ W <br />NLQUL' <br />0j u�W Q�UH <br />�T' xaz <br />�Q ) JZ <br />xOQ O <br />�i�En00 <br />0Zn� <br />� <br />av)'0§0000m <br />W aWnZWn=Z=z�2 <br />LL �QJ? <br />¢ <br />U)O <br />LL <br />wwww <br />Q�Q�25 <br />OW W <br />ZQ <br />JCL <br />Q <br />OD oQQO� <br />LL Q O LL <br />if <br />0 <br />Zw <br />O� <br />0 L_ M <br />Q Mr-- <br />O <br />u) LL ti <br />Ln <br />F-- 0� IZ <br />cM <br />Z U <br />W <br />W <br />J0 <br />O <br />O <br />O <br />o <br />O <br />r <br />0 <br />M <br />0 <br />N <br />0 <br />N <br />M <br />N <br />r <br />N <br />M <br />O <br />0)o <br />o <br />r <br />N <br />o <br />I <br />� <br />N <br />o <br />i <br />I <br />' <br />z <br />0 <br />N'^ <br />Li , <br />>w <br />o <br />r <br />0 <br />N <br />0 <br />M <br />0 <br />4 <br />o <br />LO <br />I <br />I <br />i <br />LO <br />0`/ (n <br />Q z <br />OW <br />w <br />Zzz <br />� <br />0 <br />w00 <br />�zj <br />Zowo <br />W-0- <br />r Q <br />C) <br />f- <br />Q <br />W uj <br />I- <br />r-i <br />z O = <br />■ <br />LLI <br />O <br />zwo <br />U <br />CLZU- <br />w <br />Z <br />az <br />0U <br />0� <br />� <br />W <br />z <br />A5 <br />z <br />z <br />Lu <br />w <br />0 <br />N <br />N <br />LAST PLOT DATE <br />• <br />z 0 <br />March 22, 2023 <br />J <br />EXTERIOR <br />ELEVATIONS A <br />