Laserfiche WebLink
0 <br />1 v <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED--------,,. <br />WEEP SCREED-------., 1/4" AIR GAP ~� <br />BETWEEN WEEP <br />SCREED AND FLASHING <br />COUNTER FLASHING <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL <br />FLASHING <br />PT 1X10 BLOCKING <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />CEMENT MORTAR----_.� <br />TILE ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 8" <br />ROOF SHEATHING <br />PER PLAN --- <br />311=1 1_011 <br />11— 1 1-011 <br />W <br />WALL SHEATHING PER PLAN <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP) <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED --- <br />WEEP SCREED <br />HOLD 1/4" AIR GAP <br />BETWEEN WEEP <br />SCREED AND FLASHING <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL --- <br />PT 1X BLOCKING — <br />COUNTER FLASHING----.�� ``� <br />00 <br />PAN FLASHING 6" MIN----­__� <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 6"----- <br />... ... .... . .. <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />TILE ROOF PER SPECS--- — <br />2X NAILER SECURELY <br />FASTENED TO DECK — <br />ROOF SHEATHING <br />PER PLAN -- <br />NOTE: r. .� <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE <br />OUT OF CORROSION <br />-RESISTANT MATERIAL <br />HEAD WALL <br />3LE ROOF PER SPECS <br />RLAYMENT <br />iINGLE OVER <br />EDGE <br />SHEATHING <br />'LAN <br />EDGE <br />UB FASCIA <br />ADHERED WRB TO <br />ALE OVER WRB ON <br />BELOW <br />INUM BRAKE METAL WRAP <br />BACKER ROD <br />>EALANT <br />CO'T MOULDING <br />OFF BRAKE METAL <br />IN <br />CO ON FRAME - 7/8" <br />kT SAND FINISH STUCCO <br />:LF FURRING LATH ON 2- <br />;S OF WATER RESISTIVE <br />IER COMPLYING WITH <br />E2556, TYPE 1 (TYP) <br />SHEATHING PER PLAN <br />RAKE WALL <br />WP16 <br />W001 <br />FIBER CEMENT SIDING <br />PER ELEVATIONS <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER FLASHING — <br />STARTER STRI <br />HOLD 1/4" AIR GAP <br />BETWEEN SIDING AND <br />FLASHING <br />COUNTER FLASHING <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL <br />FLASHING <br />PT 1X10 BLOCKING <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />CEMENT MORTAR <br />TILE ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />311= 1 1-011 <br />HEAD WALL <br />LE TCJ <br />WALL SHEATHING PER P <br />FIBER CEMENT SIDING <br />PER ELEVATIONS <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER FLASHING — <br />STARTER STRIP <br />HOLD 1/4" AIR GAP <br />BETWEEN SIDING AND <br />FLASHING <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL <br />PT 1X BLOCKING <br />COUNTER FLASHING----____-'` <br />PAN FLASHING 6" MIN ---_�� <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 6"--, <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />TILE ROOF PER SPECS----_._ <br />2X NAILER SECURELY <br />FASTENED TO DECK <br />ROOF SHEATHING <br />PER PLAN--------- <br />I�7 <br />FLASHING REQUIREMENTS <br />R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A <br />WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE <br />SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. <br />R703.1 .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED <br />AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER <br />WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE <br />EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO <br />THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. <br />R703.2 WATER RESISTIVE BARRIER. ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM <br />HOLES, COMPLY WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED <br />WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL <br />EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE <br />UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE <br />JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED <br />MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE <br />BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT <br />OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN <br />ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />BARRIER IS DIRECTED BETWEEN THE LAYERS, <br />EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />01 DESIGNED DRAINAGE SPACE. <br />R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED <br />MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S <br />RAKE WALL INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />BUILDING STRUCTURAL FRAMING <br />WP17 SELF -ADHERED MEMBRANES USEDASFLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />WALLS SHALL COMPLY WITH AAMA 714, THE FLASHING SHALL EXTEND TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH, APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />FOLLOWING LOCATIONS: <br />1. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW <br />AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING <br />INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN <br />FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD <br />AND SIDES, <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />REGISTERED DESIGN PROFESSIONAL. <br />1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />250, FMA/AAMA/WDMA 300 OR FMA/AAMA/WDMA 400, <br />2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />COPINGS AND SILLS. <br />4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION, <br />6.6 AT WALL AND ROOF INTERSECTIONS. <br />7.7 AT BUILT-IN GUTTERS. <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />APR 0 8 2nal <br />e <br />v/RA <br />Vi"ILal Y'eview Assist, Inc. <br />Ce14]lked and eppra <br />'" 2 r�ipaP ego: t0th the 2020 FBE 7th Edition <br />nrho Winne fflmhr PX2300 <br />CD <br />CU <br />.C' <br />Z3 <br />N <br />CD- <br />C <br />Q <br />2CuT3 <br />Qa <br />0_ <br />0—CD <br />Q <br />2— <br />© <br />Q) <br />Cu <br />0 <br />Cry <br />u— <br />O <br />. cn <br />zi <br />cn <br />Qa <br />O <br />2 <br />.E <br />I— <br />CCz <br />—0., <br />d <br />U) <br />C:L <br />'Q <br />0 <br />0 <br />w <br />d <br />Z <br />d <br />IL <br />(D <br />U) <br />Cu <br />O <br />Q <br />C..7 <br />0 <br />O <br />L- <br />0— <br />CU <br />m <br />m <br />SHEET N0. <br />WP 2.1 <br />