My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6246 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6246 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 10:52:41 PM
Creation date
2/18/2025 4:29:05 PM
Metadata
Fields
Template:
Building Plans
Street #
6246
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
6070
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A/C <br />DISCONNECT <br />WP <br />GFI <br />DEm <br />a <br />ELEC <br />METER <br />LINE 0. <br />STRUCTURE ABOVE <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION B' <br />1 /4" = 1'-011 <br />SECOND FLOOR ELECTRICAL PLAN (ELEVATION B' <br />1 /4„ = 1 '-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1, ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE, <br />3, ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017, <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />APR 0 8 rn ) <br />Virtual Review Assist, Inc. <br />Mans Review completed and approver <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Mahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH - -- <br />c� <br />SWITCH--° <br />4 1 /2" <br />DOORJAMB DUPLEX in <br />TRIM <br />OUTLET--- ih <br />� <br />O <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o2� <br />Ilk—SMOKE DETECTOR <br />1'-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />0- WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />sw STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-o PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />{A� CLG MNT LT FIXTURE <br />{B} CLG MNT PREWIRE - FIXTURE BY OWNER <br />+ SURFACE MNT FIXTURE <br />- - WALL MNT FIXTURE _ <br />NOTE: <br />ND OPALEX - ALTERNATE <br />TUB/SHCWERCANS MAY BE <br />50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />0 50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />o� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-E� CLG FAN PREWIRE AND SWITCH <br />cs COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR . <br />SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24- UNDER CABINET 24" <br />-S-24- SINGLE 24" FLUOR STRIP <br />-D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />— S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />96: 24 :;;] 24" VANITY LIGHTING <br />E_= 36 36" VANITY LIGHTING <br />F---48 48" VANITY LIGHTING <br />0 EXHAUST FAN/LIGHT <br />® EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />0 15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />l� MASTER STATION <br />» ELEC PANEL <br />M VACUM OUTLET AT 12" <br />[;� CEILING RETURN AIR <br />® A/C REGISTER <br />(T) THERMOSTAT <br />IR SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />^N` <br />W N LO N E <br />(i <br />N <br />V <br />M 0 2a <br />Q <br />•SIN` <br />.0 u � <br />Lu g4 <br />W <br />70 <br />M C <br />L Q ��2 .2 <br />C) <br />Ul <br />LL <br />w <br />O0LFu_Lu J <br />Lu << p <br />O z <br />W <br />('fY <br />=)2�'nYO <br />) U0XLLCUL JO <br />�1 <br />p0i'00gWpxmz <br />z� <br />0 <br />U)LL <br />11 Lu z <br />u0j0LuLO � <br /><—Z <br />¢Ow HgN a <br />0 <br /><O <br />LL O 9 <br />O <br />N <br />Z Lu <br />0 I— <br />H <br />'�D 60 CD <br />a - " <br />J Li <br />li <br />LL <br />uj <br />zV00 <br />Z <br />Lu <br />CD <br />J0 <br />�O <br />1 d" <br />0 <br />0 <br />0 <br />� <br />o <br />M <br />� <br />� <br />r- <br />0 <br />0 <br />0 <br />O <br />c. <br />O <br />o <br />OO <br />Qa <br />r <br />(0 <br />T- <br />00 <br />r <br />00 <br />O <br />N <br />O <br />N <br />O <br />N <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />cV <br />O <br />N <br />O <br />O <br />O <br />r <br />O <br />T-- <br />cD <br />p <br />N <br />c- <br />A <br />O <br />4 <br />O <br />r <br />o <br />d) <br />0 <br />C6 <br />o <br />O <br />r- <br />O <br />� <br />N <br />O <br />0 <br />1 <br />L <br />N <br />0 <br />> <br />.— <br />a <br />N <br />0 <br />Cl) <br />0 <br />d <br />0 <br />LO <br />0 <br />CO <br />0 <br />1, <br />1 <br />cr <br />00 <br />co <br />z z <br />O <br />-�--� <br />L110 <br />~ > <br />Q <br />00 <br />0 <br />M <br />~ <br />�-- <br />0 <br />O d <br />Q =W <br />Z <br />Zot�I— <br />r� <br />=00Cz <br />(�O�w <br />Q <br />2 <br />` <br />zWT- <br />4 <br />(L <br />Z z <br />CSC <br />W h <br />Oa2z <br />O <br />00 <br />) Z U) <br />Z <br />o <br />Z <br />U <br />U� <br />oQ <br />W <br />� <br />z <br />A6 <br />z <br />w <br />W <br />M <br />N <br />N <br />LAST PLOT DATE <br />Mar. 9, 23 <br />Z <br />p <br />1 ST & 2ND FLOOR <br />I <br />ELECTRICAL PLAN B <br />
The URL can be used to link to this page
Your browser does not support the video tag.