My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6312 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6312 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:35:59 PM
Creation date
2/18/2025 4:30:35 PM
Metadata
Fields
Template:
Building Plans
Street #
6312
Location
Beverly Hills Dr
Contractor
Lennar Homes
Building Plans - Permit #
4823
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENGINEERING <br />SPECIFICATIONS <br />PRODUCT DESCRIPTION <br />HIGH STRENGTH PRECAST CONCRETE LINTELS DESIGNED TO BE UNFILLED OR FILLED TO FORM A COMPOSITE REINFORCED BEAM USING CONCRETE MASONRY UNITS. <br />MATERIALS <br />• F'C 8" PRECAST LINTELS = 3500 PSI • CONCRETE MASONRY UNITS (CMU) PER ASTM C90 WITH <br />• F'C 8" PRESTRESSED, 6" AND 12" PRECAST LINTELS = 6000 PSI MINIMUM NET AREA COMPRESSIVE STRENGTH = 1900 PSI <br />• F'C 4" PRECAST LINTELS = 3000 PSI • REBAR PER ASTM A615 GRADE 60 <br />• GROUT PER ASTM C476 F'G = 3000 PSI W/ MAXIMUM • PRESTRESSING STRAND PER ASTM A416 GRADE 270 LOW RELAXATION <br />3/8 INCH AGGREGATE AND 8 TO 11 INCH SLUMP. • 7/32 INCH WIRE PER ASTM A510 <br />• MORTAR PER ASTM C270 TYPE M OR S <br />GENERAL NOTES <br />1. PROVIDE FULL MORTAR HEAD AND BED JOINTS. <br />2. SHORE FILLED LINTELS AS REQUIRED. <br />3. INSTALLATION OF LINTEL MUST COMPLY WITH <br />ARCHITECTURAL AND/OR STRUCTURAL DRAWINGS. <br />4. U-LINTELS ARE MANUFACTURED WITH 5-1/2 INCH LONG <br />NOTCHES AT ENDS TO ACCOMMODATE VERTICAL CELL <br />REINFORCING AND GROUTING. <br />5. ALL LINTELS MEET OR EXCEED L/360 VERTICAL <br />DEFLECTION, EXCEPT LINTELS 17'-4" AND LONGER WITH A <br />NOMINAL HEIGHT OF 8" MEET OR EXCEED L/180. <br />6. BOTTOM FIELD ADDED REBAR TO BE LOCATED AT THE <br />BOTTOM OF LINTEL CAVITY, <br />7. 7/32 INCH DIAMETER WIRE STIRRUPS ARE WELDED TO THE <br />BOTTOM STEEL FOR MECHANICAL ANCHORAGE. <br />SAFE LOAD TABLE NOTES <br />1. ALL VALUES BASED ON MINIMUM 4 INCH NOMINAL BEARING. <br />EXCEPTION: SAFE LOADS FOR UNFILLED LINTELS MUST BE REDUCED <br />BY 20 % IF BEARING LENGTH IS LESS THAN 6-1/2 INCHES. <br />2. N.R. = NOT RATED. <br />3. SAFE LOADS ARE SUPERIMPOSED ALLOWABLE LOAD. <br />4. SAFE LOADS BASED ON GRADE 40 OR GRADE 60 FIELD REBAR. <br />5. ADDITIONAL LATERAL LOAD CAPACITY CAN BE OBTAINED BY THE <br />DESIGNER BY PROVIDING ADDITIONAL REINFORCED MASONRY <br />ABOVE THE PRECAST LINTEL. SEE REINFORCED CMU ON PAGE 4. <br />6. ONE #7 REBAR MAY BE SUBSTITUTED FOR TWO #5 REBARS IN 8" <br />LINTELS ONLY. <br />7. THE DESIGNER MAY EVALUATE CONCENTRATED LOADS FROM THE <br />SAFE LOAD TABLES BY CALCULATING THE MAXIMUM RESISTING <br />MOMENT AND SHEAR AT D-AWAY FROM THE FACE OF SUPPORT. <br />8. CAST -IN -PLACE CONCRETE MAY BE PROVIDED IN COMPOSITE LINTEL IN <br />LIEU OF CONCRETE MASONRY UNITS. <br />9. SAFE LOAD RATINGS BASED ON RATIONAL DESIGN ANALYSIS PER ACI <br />318 AND ACI 530 <br />10. PRODUCT APPROVALS: MIAMI DADE COUNTY, FLORIDA NOS. 03-0605.05 <br />AND 03-0605.04 <br />11. THE EXTERIOR SURFACE OF LINTELS INSTALLED IN EXTERIOR <br />CONCRETE MASONRY WALLS SHALL HAVE A COATING OF STUCCO <br />APPLIED IN ACCORDANCE WITH ASTM C926 OR OTHER APPROVED <br />COATING. <br />12. LINTELS LOADED SIMULTANEOUSLY WITH VERTICAL (GRAVITY OR <br />UPLIFT) AND HORIZONTAL (LATERAL) LOADS SHOULD BE CHECKED FOR <br />THE COMBINED LOADING WITH THE FOLLOWING EQUATION: <br />APPLIED VERTICAL LOAD + <br />SAFE VERTICAL LOAD <br />APPLIED HORIZONTAL LOAD <br />SAFE HORIZONTAL LOAD <br />8. FOR COMPOSITE LINTEL HEIGHTS NOT SHOWN, USE SAFE <br />LOAD FROM NEXT LOWER HEIGHT. <br />9. FOR LINTEL LENGTHS NOT SHOWN, USE SAFE LOAD FROM <br />NEXT LONGEST LENGTH. <br />10. ALL SAFE LOADS IN UNITS OF POUNDS PER LINEAR FOOT. <br />11. ALL SAFE LOADS BASED ON SIMPLY SUPPORTED SPAN. <br />12. THE NUMBER IN THE PARENTHESIS INDICATES THE <br />PERCENT REDUCTION FOR GRADE 40 FIELD ADDED REBAR. <br />EXAMPLE: T-6" LINTEL TYPE 8F32-1 B SAFE GRAVITY LOAD = <br />6472 (15) W/ 15% REDUCTION => 6472 (.85) = 5501 PLF <br />SAFE LOAD TABLES <br />For Gravity, Uplift & Lateral Loads <br />SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />CAST-4494" SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F8-0B 8F12-0B 8F16-OB 8F20 OB 8F24-08 BF28-0B 8F32 OB <br />LENGTH 8U8 8F8-1B 81`12-18 81`16-18 81`20.18 8F24.18 BF28.1B 8F32.16 <br />3069 4605 6113 7547 8974 10394 11809 <br />2'-10" (34") PRECAST 2231 3069 4605 6113 7547 8974 10394 11809 <br />3'-6" (42") PRECAST 2231 3069 3719 5163 6607 8054 9502 10951 <br />3069 4605 6113 7547 8974 10394 11809 <br />2561 2751 3820 4890 5961 7034 8107 <br />4'-0" (48") PRECAST 1966 2693 4605 6113 7547 8974 10394 11809 <br />4'-6" (54") PRECAST 1599 1969 2110 2931 3753 4576 5400 6224 <br />2189 4375 6113 7547 (71 8672 10294 11809 <br />5'4" (64") PRECAST 1217 1349 1438 1999 2560 3123 3686 4249 <br />1663 3090 5365 7547 36 7342 19 8733 19 10127 19 <br />1105 1173 1631 2090 2549 3009 3470 <br />5'-10" (70") PRECAST 1062 1451 2622 4360 7168 45 6036 19 7181 19 8328 20 <br />1238 2177 3480 3031 3707 4383 5061 <br />6'-6" (78") PRECAST 908 1238 1 2177 3480 5381 8360 10394 31 8825 14 <br />T-6" (90") PRECAST 743 1011 1729 2632 2205 2698 3191 3685 <br />1011 1729 2661 3898 5681 8467 44 6472 15 <br />9'-4" (112") PRECAST 554 699 1160 1625 2564 3486 2818 3302 <br />752 1245 1843 2564 3486 4705 37 6390 47 <br />10'-6" (126") PRECAST 475 535 890 1247 2093 2777 2163 2536 <br />643 1052 1533 2093 2781 3643 38 4754 45 <br />582 945 1366 1846 2423 3127 4006 <br />11' 4" (136") PRECAST 362 582 945 1366 1846 2423 3127 4006 <br />12'-0" (144") PRECAST 337 540 873 1254 1684 2193 2805 3552 <br />540 873 1254 1684 2193 2805 3552 <br />471 755 1075 1428 1838 2316 2883 <br />13'4" (160") PRECAST 296 471 755 1075 1428 1838 2316 1 2883 <br />424 706 1002 1326 1697 2127 2630 <br />14'-0" (168") PRECAST 279 442 706 1002 1326 1697 2127 2630 <br />NR NR NR NR NR NR NR <br />14'-8" (176") PRESTRESSED N.R. 458 783 1 1370 1902 2245 2517 2712 <br />PRESTRESSED NR NR NR NR NR NR NR <br />15'4" (184") N.R. 412 710 1250 1733 2058 2320 1 2513 <br />NR <br />17'4" (208") PRESTRESSED N.R. NR NR NR NR NR NR300 548 950 1326 1609 1849 2047 <br />19'-4" (232") PRESTRESSED N R. NR NR NR NR NR NR NR <br />235 420 750 1037 1282 1515 1716 <br />21'-4" (256") PRESTRESSED N R. NR NR NR NR NR NR NR <br />180 340 598 845 1114 1359 1 1468 <br />22'-0" (264") PRESTRESSED N R. NR NR NR NR NR NR NR <br />165 315 550 784 1047 1285 1399 <br />24'-0" (288") PRESTRESSED N R NR NR NR NR NR NR NR <br />129 250 450 654 884 1092 1222 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />SAFE GRAVITY LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />CAST-CRm SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6-OB 8RF10-0B 8RF14-OB 8RF18-OB 8RF22-08 8RF26-08 8RF30-0B <br />LENGTH 8RU6 8RF6.1B 8RF10-1B 8RF14-IB 8RF18-1B 8RF22-1B 8RF26-1B 8RF30-1B <br />1749 3355 3280 4349 5421 6493 7567 <br />4'-4" (52") PRECAST 1635 1891 3699 5206 6639 8060 9479 10893 <br />1596 3063 2992 3968 4946 5924 6904 <br />4'-6" (54") PRECAST 1494 1756 3699 5206 6639 8060 9479 10893 <br />5'-8" (68") PRECAST 866 920 1770 1716 2277 2839 3402 3966 <br />1167 2481 4567 6389 8060 34 791719 9311 19 <br />5'-10" (70") PRECAST 810 859 1653 1600 2124 2649 3174 3700 <br />1113 2342 4242 6639 10 8060 39 7402 19 8706 19 <br />6'-8" (80") PRECAST 797 901 1825 3120 5048 7747 9448 7360 <br />901 1825 3120 5048 7915 9479 10893 32 <br />755 1490 2459 3776 5743 7239 5623 <br />7' 6" (90") PRECAST 669 755 1490 2459 3776 5743 8998 19 10893 48 <br />466 999 1568 2253 3129 4091 3146 <br />9'-8" (116") PRECAST 411 526 999 1568 2253 3129 4150 5891 47 <br />SAFE LATERAL LOADS FOR <br />8" PRECAST & PRESTRESSED U-LINTELS <br />4^zr-4R� SAFE GOAD <br />''� • PLF <br />TYPE 8U8 81`8 REINF. <br />LENGTH CMU* <br />2'-10" (34") PRECAST 1293 1642 2135 <br />3'-6" (42") PRECAST 1025 1024 1830 <br />4-0" (48") PRECAST 765 763 1365 <br />4-6" (54") PRECAST 592 591 1057 <br />64" (64") PRECAST 411 411 734 <br />5'-10" (70") PRECAST 340 339 607 <br />6'-6" (78") PRECAST 507 721 483 <br />T-6" (90") PRECAST 424 534 357 <br />9'-4" (112") PRECAST 326 512 227 <br />10'-6" (126") PRECAST 284 401 178 <br />11'-4" (136") PRECAST 260 452 152 <br />12'-0" (144") PRECAST 244 402 135 <br />13'-4" (160") PRECAST 217 324 109 <br />14'-0" (168") PRECAST 205 293 98 <br />14'-8" (176") PRESTRESSED N.R. 284 89 <br />15'-4" (184") PRESTRESSED N.R. 259 82 <br />17'-4" (208") PRESTRESSED N.R. 194 63 <br />19'-4" (232") PRESTRESSED N.R. 148 51 <br />21'-4" (256") PRESTRESSED N.R. 125 42 <br />22'-0" (264") PRESTRESSED N.R. 116 39 <br />24'-0" (288") PRESTRESSED N.R. 91 33 <br />* SEE NOTE 18 <br />SAFE LATERAL LOADS FOR <br />A" PRFCAST w/ 9" RFCFSS DnnR U-1 INTFI S <br />4ftWr-404" SAFE LOAD <br />PLF <br />TYPE 8RU6 8RF6 EINF• <br />LENGTH <br />4'-4" (52") PRECAST 758 757 1365 <br />4'-6" (54") PRECAST 694 693 1249 <br />5'-8" (68") PRECAST 408 407 734 <br />5'-10" (70") PRECAST 382 381 687 <br />6'-8" (80") PRECAST 595 788 510 <br />T-6" (90") PRECAST 509 674 393 <br />9'-8" (116") PRECAST 370 490 227 <br />- 1.0 <br />SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />CAl -4494 ! SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F8.1T 8F12-1T 8F16-1T 8F20-1T 8F24.1T 8F26.1T 8F32.1T <br />LENGTH 8F8.2T BF12.2T 8F16.2T 8F20-2T 8F24.2T BF28-2T 8F32-2T <br />1972 3173 4460 5747 7034 8321 9608 <br />2'-10" (34") PRECAST 1972 3173 4460 5747 7034 8321 9608 <br />1569 2524 3547 4569 5591 6613 7636 <br />3'-6" (42") PRECAST 1569 2524 3547 4569 5591 6613 7636 <br />4'-0" (48") PRECAST 1363 2192 3079 3966 4853 5740 6627 <br />1363 2192 3079 3966 4853 5740 6627 <br />4'-6" (54") PRECAST 1207 1940 2724 3508 4292 5077 5861 <br />1207 1940 2724 3508 4292 5077 5861 <br />5'-4" (64") PRECAST 1016 1 1632 2290 2949 3607 4265 4924 <br />1016 1632 2290 2949 3607 4265 4924 <br />5'-10" (70") PRECAST 909 1492 2093 2694 3295 3897 4498 <br />929 1492 2093 2694 3295 3897 4498 <br />6'-6" (78") PRECAST 835 12 1340 1880 2419 2959 3498 4038 <br />835 1340 1880 2419 2959 3498 4038 <br />127 23 1021 1634 12 210 11 2571 10 3039 (10 3508 9 <br />7'-6" (90") PRECAST 727 1166 1634 2102 1 25t 1 3039 3508 <br />9'-4" (112") PRECAST 591 680 113 15 147115 181 15 2152 16 2494 15 <br />591 851 1326 1705 2084 2463 2842 <br />10'-6" (126") PRECAST 530 552 91415 118 15 1458 15 173215 2007 15 <br />530 686 1183 1526 1865 2204 2544 <br />11'4" (136") PRECAST 474 485 79815 1034 15 1272 15 1510 15 1749 15 <br />494 599 1028 1422 1 1738 2053 2369 <br />470 9 441 723 14 936 14 1151 15 1366 15 1582 15 <br />12'-0" (144") PRECAST 470 543 928 1349 1649 1948 2247 <br />13'-4" (160") PRECAST 41815 373 606 14 783 14 962 14 1141 14 1321 14 <br />428 455 770 1145 1444 1718 1993 <br />384 15 346 559 14 723 14 887 14 105214 121814 <br />14'-0" (168") PRECAST 410 420 1 709 1050 1 1434 g 1694 (8)1 1954 7 <br />14'-8" (176") PRESTRESSED 239 323 519 13 671 13 823 13 976 14 1129 14 <br />246 390 655 968 1324 8 162 11 187411 <br />15'-4" (184") PRESTRESSED 224 302 485 13 626 13 767 13 909 13) 1052 13 <br />230 364 609 897 1224 8 1562 14 1801 14 <br />17'-4" (208") PRESTRESSED 187 255 404 12 520 12 637 12 754 12 872 12 <br />192 303 500 732 993 B 1268 14 1E 14 <br />19'-4" (232") PRESTRESSED 162 222 34711 44611 546 12 646 12 74612 <br />166 261 424 616 831 8 105714 1225 14 <br />21'-4" (256") PRESTRESSED 142 198 30611 39311 48011 56711 65411 <br />142 230 369 531 1 713 7 903 13 1046 13 <br />22'-0" (264") PRESTRESSED 137 192 295 10 37811 461 10 54511 �9(1 <br />137 221 354 508 681 7 86113 24'-0" (288") PRESTRESSED 124 175 267 10 341 10 416 10 49 110 5 <br />124 200 316 450 600 7 75612 875 13 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />lcawr-4494" SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14.1T 8RF18.1T SRF22.1T 8RF26-1T 8RF30-IT <br />LENGTH 8RF6-2T 8RF10.2T 8RF14-2T 8RF18-2T BRF22-2T 8RF26-2T 8RF30-2T <br />905 1748 2635 3522 4409 5296 6183 <br />4'-4" (52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />(54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />4'-6' 867 1675 2525 3374 4224 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />T-6" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 2442 2931 1 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15 1640 15 198015 2322 16 <br />395 589 1135 1514 1893 2272 1 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR * SEE NOTE 18 (#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />° • 4 , ' 4 ° < <br />> D > D 4 <br />D D D <br />C C <br />C C C C C C C <br />8F16-1 B/OT 8F16-1 B/1T 8RF14n-1 B/OT 8F8-1 B <br />° 4 <br />Q <br />°0 <br />°D <br />> > <br />°D O C <br />S� D <br />8F12-0B/1T <br />D <br />C C <br />8" PRECAST LINTEL W/ (1#5 HOR CONT <br />BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />C.M.U. <br />0w x oD <br />2cnmwwO <br />V-`nN <br />cn ° <br />a #5REBAR AT <br />ow 0 bO o w a BOTTOM MIN. (1) <br />w < 0 wZ REQ'D <br />�WC7JJJ <br />z W ¢ w 16 GAUGE <br />W ° POWERS STEEL <br />U) � z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />W�-GROUT <br />1/2" CLEAR <br />J <br />C.M.U. <br />`4LO EBAR AT BOTTOM <br />LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8" PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) <br />� � QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />C� <br />z= <br />C C <br />OF <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />AEG 2 y 2022 <br />.i <br />LO <br />Ln <br />r, <br />Z It <br />0 <br />LL <br />w <br />LCN <br />L <br />Loo <br />o <br />co <br />" <br />LL <br />x <br />-.qt <br />1 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />SAFE GRAVITY LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />CAST-CRm SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6-OB 8RF10-0B 8RF14-OB 8RF18-OB 8RF22-08 8RF26-08 8RF30-0B <br />LENGTH 8RU6 8RF6.1B 8RF10-1B 8RF14-IB 8RF18-1B 8RF22-1B 8RF26-1B 8RF30-1B <br />1749 3355 3280 4349 5421 6493 7567 <br />4'-4" (52") PRECAST 1635 1891 3699 5206 6639 8060 9479 10893 <br />1596 3063 2992 3968 4946 5924 6904 <br />4'-6" (54") PRECAST 1494 1756 3699 5206 6639 8060 9479 10893 <br />5'-8" (68") PRECAST 866 920 1770 1716 2277 2839 3402 3966 <br />1167 2481 4567 6389 8060 34 791719 9311 19 <br />5'-10" (70") PRECAST 810 859 1653 1600 2124 2649 3174 3700 <br />1113 2342 4242 6639 10 8060 39 7402 19 8706 19 <br />6'-8" (80") PRECAST 797 901 1825 3120 5048 7747 9448 7360 <br />901 1825 3120 5048 7915 9479 10893 32 <br />755 1490 2459 3776 5743 7239 5623 <br />7' 6" (90") PRECAST 669 755 1490 2459 3776 5743 8998 19 10893 48 <br />466 999 1568 2253 3129 4091 3146 <br />9'-8" (116") PRECAST 411 526 999 1568 2253 3129 4150 5891 47 <br />SAFE LATERAL LOADS FOR <br />8" PRECAST & PRESTRESSED U-LINTELS <br />4^zr-4R� SAFE GOAD <br />''� • PLF <br />TYPE 8U8 81`8 REINF. <br />LENGTH CMU* <br />2'-10" (34") PRECAST 1293 1642 2135 <br />3'-6" (42") PRECAST 1025 1024 1830 <br />4-0" (48") PRECAST 765 763 1365 <br />4-6" (54") PRECAST 592 591 1057 <br />64" (64") PRECAST 411 411 734 <br />5'-10" (70") PRECAST 340 339 607 <br />6'-6" (78") PRECAST 507 721 483 <br />T-6" (90") PRECAST 424 534 357 <br />9'-4" (112") PRECAST 326 512 227 <br />10'-6" (126") PRECAST 284 401 178 <br />11'-4" (136") PRECAST 260 452 152 <br />12'-0" (144") PRECAST 244 402 135 <br />13'-4" (160") PRECAST 217 324 109 <br />14'-0" (168") PRECAST 205 293 98 <br />14'-8" (176") PRESTRESSED N.R. 284 89 <br />15'-4" (184") PRESTRESSED N.R. 259 82 <br />17'-4" (208") PRESTRESSED N.R. 194 63 <br />19'-4" (232") PRESTRESSED N.R. 148 51 <br />21'-4" (256") PRESTRESSED N.R. 125 42 <br />22'-0" (264") PRESTRESSED N.R. 116 39 <br />24'-0" (288") PRESTRESSED N.R. 91 33 <br />* SEE NOTE 18 <br />SAFE LATERAL LOADS FOR <br />A" PRFCAST w/ 9" RFCFSS DnnR U-1 INTFI S <br />4ftWr-404" SAFE LOAD <br />PLF <br />TYPE 8RU6 8RF6 EINF• <br />LENGTH <br />4'-4" (52") PRECAST 758 757 1365 <br />4'-6" (54") PRECAST 694 693 1249 <br />5'-8" (68") PRECAST 408 407 734 <br />5'-10" (70") PRECAST 382 381 687 <br />6'-8" (80") PRECAST 595 788 510 <br />T-6" (90") PRECAST 509 674 393 <br />9'-8" (116") PRECAST 370 490 227 <br />- 1.0 <br />SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />CAl -4494 ! SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F8.1T 8F12-1T 8F16-1T 8F20-1T 8F24.1T 8F26.1T 8F32.1T <br />LENGTH 8F8.2T BF12.2T 8F16.2T 8F20-2T 8F24.2T BF28-2T 8F32-2T <br />1972 3173 4460 5747 7034 8321 9608 <br />2'-10" (34") PRECAST 1972 3173 4460 5747 7034 8321 9608 <br />1569 2524 3547 4569 5591 6613 7636 <br />3'-6" (42") PRECAST 1569 2524 3547 4569 5591 6613 7636 <br />4'-0" (48") PRECAST 1363 2192 3079 3966 4853 5740 6627 <br />1363 2192 3079 3966 4853 5740 6627 <br />4'-6" (54") PRECAST 1207 1940 2724 3508 4292 5077 5861 <br />1207 1940 2724 3508 4292 5077 5861 <br />5'-4" (64") PRECAST 1016 1 1632 2290 2949 3607 4265 4924 <br />1016 1632 2290 2949 3607 4265 4924 <br />5'-10" (70") PRECAST 909 1492 2093 2694 3295 3897 4498 <br />929 1492 2093 2694 3295 3897 4498 <br />6'-6" (78") PRECAST 835 12 1340 1880 2419 2959 3498 4038 <br />835 1340 1880 2419 2959 3498 4038 <br />127 23 1021 1634 12 210 11 2571 10 3039 (10 3508 9 <br />7'-6" (90") PRECAST 727 1166 1634 2102 1 25t 1 3039 3508 <br />9'-4" (112") PRECAST 591 680 113 15 147115 181 15 2152 16 2494 15 <br />591 851 1326 1705 2084 2463 2842 <br />10'-6" (126") PRECAST 530 552 91415 118 15 1458 15 173215 2007 15 <br />530 686 1183 1526 1865 2204 2544 <br />11'4" (136") PRECAST 474 485 79815 1034 15 1272 15 1510 15 1749 15 <br />494 599 1028 1422 1 1738 2053 2369 <br />470 9 441 723 14 936 14 1151 15 1366 15 1582 15 <br />12'-0" (144") PRECAST 470 543 928 1349 1649 1948 2247 <br />13'-4" (160") PRECAST 41815 373 606 14 783 14 962 14 1141 14 1321 14 <br />428 455 770 1145 1444 1718 1993 <br />384 15 346 559 14 723 14 887 14 105214 121814 <br />14'-0" (168") PRECAST 410 420 1 709 1050 1 1434 g 1694 (8)1 1954 7 <br />14'-8" (176") PRESTRESSED 239 323 519 13 671 13 823 13 976 14 1129 14 <br />246 390 655 968 1324 8 162 11 187411 <br />15'-4" (184") PRESTRESSED 224 302 485 13 626 13 767 13 909 13) 1052 13 <br />230 364 609 897 1224 8 1562 14 1801 14 <br />17'-4" (208") PRESTRESSED 187 255 404 12 520 12 637 12 754 12 872 12 <br />192 303 500 732 993 B 1268 14 1E 14 <br />19'-4" (232") PRESTRESSED 162 222 34711 44611 546 12 646 12 74612 <br />166 261 424 616 831 8 105714 1225 14 <br />21'-4" (256") PRESTRESSED 142 198 30611 39311 48011 56711 65411 <br />142 230 369 531 1 713 7 903 13 1046 13 <br />22'-0" (264") PRESTRESSED 137 192 295 10 37811 461 10 54511 �9(1 <br />137 221 354 508 681 7 86113 24'-0" (288") PRESTRESSED 124 175 267 10 341 10 416 10 49 110 5 <br />124 200 316 450 600 7 75612 875 13 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />lcawr-4494" SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14.1T 8RF18.1T SRF22.1T 8RF26-1T 8RF30-IT <br />LENGTH 8RF6-2T 8RF10.2T 8RF14-2T 8RF18-2T BRF22-2T 8RF26-2T 8RF30-2T <br />905 1748 2635 3522 4409 5296 6183 <br />4'-4" (52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />(54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />4'-6' 867 1675 2525 3374 4224 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />T-6" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 2442 2931 1 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15 1640 15 198015 2322 16 <br />395 589 1135 1514 1893 2272 1 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR * SEE NOTE 18 (#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />° • 4 , ' 4 ° < <br />> D > D 4 <br />D D D <br />C C <br />C C C C C C C <br />8F16-1 B/OT 8F16-1 B/1T 8RF14n-1 B/OT 8F8-1 B <br />° 4 <br />Q <br />°0 <br />°D <br />> > <br />°D O C <br />S� D <br />8F12-0B/1T <br />D <br />C C <br />8" PRECAST LINTEL W/ (1#5 HOR CONT <br />BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />C.M.U. <br />0w x oD <br />2cnmwwO <br />V-`nN <br />cn ° <br />a #5REBAR AT <br />ow 0 bO o w a BOTTOM MIN. (1) <br />w < 0 wZ REQ'D <br />�WC7JJJ <br />z W ¢ w 16 GAUGE <br />W ° POWERS STEEL <br />U) � z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />W�-GROUT <br />1/2" CLEAR <br />J <br />C.M.U. <br />`4LO EBAR AT BOTTOM <br />LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8" PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) <br />� � QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />C� <br />z= <br />C C <br />OF <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />AEG 2 y 2022 <br />.i <br />LO <br />Ln <br />r, <br />Z It <br />0 <br />LL <br />w <br />LCN <br />L <br />Loo <br />o <br />co <br />" <br />LL <br />x <br />-.qt <br />1 <br />SAFE LATERAL LOADS FOR <br />8" PRECAST & PRESTRESSED U-LINTELS <br />4^zr-4R� SAFE GOAD <br />''� • PLF <br />TYPE 8U8 81`8 REINF. <br />LENGTH CMU* <br />2'-10" (34") PRECAST 1293 1642 2135 <br />3'-6" (42") PRECAST 1025 1024 1830 <br />4-0" (48") PRECAST 765 763 1365 <br />4-6" (54") PRECAST 592 591 1057 <br />64" (64") PRECAST 411 411 734 <br />5'-10" (70") PRECAST 340 339 607 <br />6'-6" (78") PRECAST 507 721 483 <br />T-6" (90") PRECAST 424 534 357 <br />9'-4" (112") PRECAST 326 512 227 <br />10'-6" (126") PRECAST 284 401 178 <br />11'-4" (136") PRECAST 260 452 152 <br />12'-0" (144") PRECAST 244 402 135 <br />13'-4" (160") PRECAST 217 324 109 <br />14'-0" (168") PRECAST 205 293 98 <br />14'-8" (176") PRESTRESSED N.R. 284 89 <br />15'-4" (184") PRESTRESSED N.R. 259 82 <br />17'-4" (208") PRESTRESSED N.R. 194 63 <br />19'-4" (232") PRESTRESSED N.R. 148 51 <br />21'-4" (256") PRESTRESSED N.R. 125 42 <br />22'-0" (264") PRESTRESSED N.R. 116 39 <br />24'-0" (288") PRESTRESSED N.R. 91 33 <br />* SEE NOTE 18 <br />SAFE LATERAL LOADS FOR <br />A" PRFCAST w/ 9" RFCFSS DnnR U-1 INTFI S <br />4ftWr-404" SAFE LOAD <br />PLF <br />TYPE 8RU6 8RF6 EINF• <br />LENGTH <br />4'-4" (52") PRECAST 758 757 1365 <br />4'-6" (54") PRECAST 694 693 1249 <br />5'-8" (68") PRECAST 408 407 734 <br />5'-10" (70") PRECAST 382 381 687 <br />6'-8" (80") PRECAST 595 788 510 <br />T-6" (90") PRECAST 509 674 393 <br />9'-8" (116") PRECAST 370 490 227 <br />- 1.0 <br />SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />CAl -4494 ! SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F8.1T 8F12-1T 8F16-1T 8F20-1T 8F24.1T 8F26.1T 8F32.1T <br />LENGTH 8F8.2T BF12.2T 8F16.2T 8F20-2T 8F24.2T BF28-2T 8F32-2T <br />1972 3173 4460 5747 7034 8321 9608 <br />2'-10" (34") PRECAST 1972 3173 4460 5747 7034 8321 9608 <br />1569 2524 3547 4569 5591 6613 7636 <br />3'-6" (42") PRECAST 1569 2524 3547 4569 5591 6613 7636 <br />4'-0" (48") PRECAST 1363 2192 3079 3966 4853 5740 6627 <br />1363 2192 3079 3966 4853 5740 6627 <br />4'-6" (54") PRECAST 1207 1940 2724 3508 4292 5077 5861 <br />1207 1940 2724 3508 4292 5077 5861 <br />5'-4" (64") PRECAST 1016 1 1632 2290 2949 3607 4265 4924 <br />1016 1632 2290 2949 3607 4265 4924 <br />5'-10" (70") PRECAST 909 1492 2093 2694 3295 3897 4498 <br />929 1492 2093 2694 3295 3897 4498 <br />6'-6" (78") PRECAST 835 12 1340 1880 2419 2959 3498 4038 <br />835 1340 1880 2419 2959 3498 4038 <br />127 23 1021 1634 12 210 11 2571 10 3039 (10 3508 9 <br />7'-6" (90") PRECAST 727 1166 1634 2102 1 25t 1 3039 3508 <br />9'-4" (112") PRECAST 591 680 113 15 147115 181 15 2152 16 2494 15 <br />591 851 1326 1705 2084 2463 2842 <br />10'-6" (126") PRECAST 530 552 91415 118 15 1458 15 173215 2007 15 <br />530 686 1183 1526 1865 2204 2544 <br />11'4" (136") PRECAST 474 485 79815 1034 15 1272 15 1510 15 1749 15 <br />494 599 1028 1422 1 1738 2053 2369 <br />470 9 441 723 14 936 14 1151 15 1366 15 1582 15 <br />12'-0" (144") PRECAST 470 543 928 1349 1649 1948 2247 <br />13'-4" (160") PRECAST 41815 373 606 14 783 14 962 14 1141 14 1321 14 <br />428 455 770 1145 1444 1718 1993 <br />384 15 346 559 14 723 14 887 14 105214 121814 <br />14'-0" (168") PRECAST 410 420 1 709 1050 1 1434 g 1694 (8)1 1954 7 <br />14'-8" (176") PRESTRESSED 239 323 519 13 671 13 823 13 976 14 1129 14 <br />246 390 655 968 1324 8 162 11 187411 <br />15'-4" (184") PRESTRESSED 224 302 485 13 626 13 767 13 909 13) 1052 13 <br />230 364 609 897 1224 8 1562 14 1801 14 <br />17'-4" (208") PRESTRESSED 187 255 404 12 520 12 637 12 754 12 872 12 <br />192 303 500 732 993 B 1268 14 1E 14 <br />19'-4" (232") PRESTRESSED 162 222 34711 44611 546 12 646 12 74612 <br />166 261 424 616 831 8 105714 1225 14 <br />21'-4" (256") PRESTRESSED 142 198 30611 39311 48011 56711 65411 <br />142 230 369 531 1 713 7 903 13 1046 13 <br />22'-0" (264") PRESTRESSED 137 192 295 10 37811 461 10 54511 �9(1 <br />137 221 354 508 681 7 86113 24'-0" (288") PRESTRESSED 124 175 267 10 341 10 416 10 49 110 5 <br />124 200 316 450 600 7 75612 875 13 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />lcawr-4494" SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14.1T 8RF18.1T SRF22.1T 8RF26-1T 8RF30-IT <br />LENGTH 8RF6-2T 8RF10.2T 8RF14-2T 8RF18-2T BRF22-2T 8RF26-2T 8RF30-2T <br />905 1748 2635 3522 4409 5296 6183 <br />4'-4" (52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />(54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />4'-6' 867 1675 2525 3374 4224 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />T-6" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 2442 2931 1 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15 1640 15 198015 2322 16 <br />395 589 1135 1514 1893 2272 1 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR * SEE NOTE 18 (#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />° • 4 , ' 4 ° < <br />> D > D 4 <br />D D D <br />C C <br />C C C C C C C <br />8F16-1 B/OT 8F16-1 B/1T 8RF14n-1 B/OT 8F8-1 B <br />° 4 <br />Q <br />°0 <br />°D <br />> > <br />°D O C <br />S� D <br />8F12-0B/1T <br />D <br />C C <br />8" PRECAST LINTEL W/ (1#5 HOR CONT <br />BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />C.M.U. <br />0w x oD <br />2cnmwwO <br />V-`nN <br />cn ° <br />a #5REBAR AT <br />ow 0 bO o w a BOTTOM MIN. (1) <br />w < 0 wZ REQ'D <br />�WC7JJJ <br />z W ¢ w 16 GAUGE <br />W ° POWERS STEEL <br />U) � z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />W�-GROUT <br />1/2" CLEAR <br />J <br />C.M.U. <br />`4LO EBAR AT BOTTOM <br />LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8" PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) <br />� � QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />C� <br />z= <br />C C <br />OF <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />AEG 2 y 2022 <br />.i <br />LO <br />Ln <br />r, <br />Z It <br />0 <br />LL <br />w <br />LCN <br />L <br />Loo <br />o <br />co <br />" <br />LL <br />x <br />-.qt <br />1 <br />* SEE NOTE 18 <br />SAFE LATERAL LOADS FOR <br />A" PRFCAST w/ 9" RFCFSS DnnR U-1 INTFI S <br />4ftWr-404" SAFE LOAD <br />PLF <br />TYPE 8RU6 8RF6 EINF• <br />LENGTH <br />4'-4" (52") PRECAST 758 757 1365 <br />4'-6" (54") PRECAST 694 693 1249 <br />5'-8" (68") PRECAST 408 407 734 <br />5'-10" (70") PRECAST 382 381 687 <br />6'-8" (80") PRECAST 595 788 510 <br />T-6" (90") PRECAST 509 674 393 <br />9'-8" (116") PRECAST 370 490 227 <br />- 1.0 <br />SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />CAl -4494 ! SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F8.1T 8F12-1T 8F16-1T 8F20-1T 8F24.1T 8F26.1T 8F32.1T <br />LENGTH 8F8.2T BF12.2T 8F16.2T 8F20-2T 8F24.2T BF28-2T 8F32-2T <br />1972 3173 4460 5747 7034 8321 9608 <br />2'-10" (34") PRECAST 1972 3173 4460 5747 7034 8321 9608 <br />1569 2524 3547 4569 5591 6613 7636 <br />3'-6" (42") PRECAST 1569 2524 3547 4569 5591 6613 7636 <br />4'-0" (48") PRECAST 1363 2192 3079 3966 4853 5740 6627 <br />1363 2192 3079 3966 4853 5740 6627 <br />4'-6" (54") PRECAST 1207 1940 2724 3508 4292 5077 5861 <br />1207 1940 2724 3508 4292 5077 5861 <br />5'-4" (64") PRECAST 1016 1 1632 2290 2949 3607 4265 4924 <br />1016 1632 2290 2949 3607 4265 4924 <br />5'-10" (70") PRECAST 909 1492 2093 2694 3295 3897 4498 <br />929 1492 2093 2694 3295 3897 4498 <br />6'-6" (78") PRECAST 835 12 1340 1880 2419 2959 3498 4038 <br />835 1340 1880 2419 2959 3498 4038 <br />127 23 1021 1634 12 210 11 2571 10 3039 (10 3508 9 <br />7'-6" (90") PRECAST 727 1166 1634 2102 1 25t 1 3039 3508 <br />9'-4" (112") PRECAST 591 680 113 15 147115 181 15 2152 16 2494 15 <br />591 851 1326 1705 2084 2463 2842 <br />10'-6" (126") PRECAST 530 552 91415 118 15 1458 15 173215 2007 15 <br />530 686 1183 1526 1865 2204 2544 <br />11'4" (136") PRECAST 474 485 79815 1034 15 1272 15 1510 15 1749 15 <br />494 599 1028 1422 1 1738 2053 2369 <br />470 9 441 723 14 936 14 1151 15 1366 15 1582 15 <br />12'-0" (144") PRECAST 470 543 928 1349 1649 1948 2247 <br />13'-4" (160") PRECAST 41815 373 606 14 783 14 962 14 1141 14 1321 14 <br />428 455 770 1145 1444 1718 1993 <br />384 15 346 559 14 723 14 887 14 105214 121814 <br />14'-0" (168") PRECAST 410 420 1 709 1050 1 1434 g 1694 (8)1 1954 7 <br />14'-8" (176") PRESTRESSED 239 323 519 13 671 13 823 13 976 14 1129 14 <br />246 390 655 968 1324 8 162 11 187411 <br />15'-4" (184") PRESTRESSED 224 302 485 13 626 13 767 13 909 13) 1052 13 <br />230 364 609 897 1224 8 1562 14 1801 14 <br />17'-4" (208") PRESTRESSED 187 255 404 12 520 12 637 12 754 12 872 12 <br />192 303 500 732 993 B 1268 14 1E 14 <br />19'-4" (232") PRESTRESSED 162 222 34711 44611 546 12 646 12 74612 <br />166 261 424 616 831 8 105714 1225 14 <br />21'-4" (256") PRESTRESSED 142 198 30611 39311 48011 56711 65411 <br />142 230 369 531 1 713 7 903 13 1046 13 <br />22'-0" (264") PRESTRESSED 137 192 295 10 37811 461 10 54511 �9(1 <br />137 221 354 508 681 7 86113 24'-0" (288") PRESTRESSED 124 175 267 10 341 10 416 10 49 110 5 <br />124 200 316 450 600 7 75612 875 13 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />lcawr-4494" SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14.1T 8RF18.1T SRF22.1T 8RF26-1T 8RF30-IT <br />LENGTH 8RF6-2T 8RF10.2T 8RF14-2T 8RF18-2T BRF22-2T 8RF26-2T 8RF30-2T <br />905 1748 2635 3522 4409 5296 6183 <br />4'-4" (52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />(54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />4'-6' 867 1675 2525 3374 4224 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />T-6" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 2442 2931 1 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15 1640 15 198015 2322 16 <br />395 589 1135 1514 1893 2272 1 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR * SEE NOTE 18 (#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />° • 4 , ' 4 ° < <br />> D > D 4 <br />D D D <br />C C <br />C C C C C C C <br />8F16-1 B/OT 8F16-1 B/1T 8RF14n-1 B/OT 8F8-1 B <br />° 4 <br />Q <br />°0 <br />°D <br />> > <br />°D O C <br />S� D <br />8F12-0B/1T <br />D <br />C C <br />8" PRECAST LINTEL W/ (1#5 HOR CONT <br />BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />C.M.U. <br />0w x oD <br />2cnmwwO <br />V-`nN <br />cn ° <br />a #5REBAR AT <br />ow 0 bO o w a BOTTOM MIN. (1) <br />w < 0 wZ REQ'D <br />�WC7JJJ <br />z W ¢ w 16 GAUGE <br />W ° POWERS STEEL <br />U) � z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />W�-GROUT <br />1/2" CLEAR <br />J <br />C.M.U. <br />`4LO EBAR AT BOTTOM <br />LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8" PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) <br />� � QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />C� <br />z= <br />C C <br />OF <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />AEG 2 y 2022 <br />.i <br />LO <br />Ln <br />r, <br />Z It <br />0 <br />LL <br />w <br />LCN <br />L <br />Loo <br />o <br />co <br />" <br />LL <br />x <br />-.qt <br />1 <br />- 1.0 <br />SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS <br />CAl -4494 ! SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8F8.1T 8F12-1T 8F16-1T 8F20-1T 8F24.1T 8F26.1T 8F32.1T <br />LENGTH 8F8.2T BF12.2T 8F16.2T 8F20-2T 8F24.2T BF28-2T 8F32-2T <br />1972 3173 4460 5747 7034 8321 9608 <br />2'-10" (34") PRECAST 1972 3173 4460 5747 7034 8321 9608 <br />1569 2524 3547 4569 5591 6613 7636 <br />3'-6" (42") PRECAST 1569 2524 3547 4569 5591 6613 7636 <br />4'-0" (48") PRECAST 1363 2192 3079 3966 4853 5740 6627 <br />1363 2192 3079 3966 4853 5740 6627 <br />4'-6" (54") PRECAST 1207 1940 2724 3508 4292 5077 5861 <br />1207 1940 2724 3508 4292 5077 5861 <br />5'-4" (64") PRECAST 1016 1 1632 2290 2949 3607 4265 4924 <br />1016 1632 2290 2949 3607 4265 4924 <br />5'-10" (70") PRECAST 909 1492 2093 2694 3295 3897 4498 <br />929 1492 2093 2694 3295 3897 4498 <br />6'-6" (78") PRECAST 835 12 1340 1880 2419 2959 3498 4038 <br />835 1340 1880 2419 2959 3498 4038 <br />127 23 1021 1634 12 210 11 2571 10 3039 (10 3508 9 <br />7'-6" (90") PRECAST 727 1166 1634 2102 1 25t 1 3039 3508 <br />9'-4" (112") PRECAST 591 680 113 15 147115 181 15 2152 16 2494 15 <br />591 851 1326 1705 2084 2463 2842 <br />10'-6" (126") PRECAST 530 552 91415 118 15 1458 15 173215 2007 15 <br />530 686 1183 1526 1865 2204 2544 <br />11'4" (136") PRECAST 474 485 79815 1034 15 1272 15 1510 15 1749 15 <br />494 599 1028 1422 1 1738 2053 2369 <br />470 9 441 723 14 936 14 1151 15 1366 15 1582 15 <br />12'-0" (144") PRECAST 470 543 928 1349 1649 1948 2247 <br />13'-4" (160") PRECAST 41815 373 606 14 783 14 962 14 1141 14 1321 14 <br />428 455 770 1145 1444 1718 1993 <br />384 15 346 559 14 723 14 887 14 105214 121814 <br />14'-0" (168") PRECAST 410 420 1 709 1050 1 1434 g 1694 (8)1 1954 7 <br />14'-8" (176") PRESTRESSED 239 323 519 13 671 13 823 13 976 14 1129 14 <br />246 390 655 968 1324 8 162 11 187411 <br />15'-4" (184") PRESTRESSED 224 302 485 13 626 13 767 13 909 13) 1052 13 <br />230 364 609 897 1224 8 1562 14 1801 14 <br />17'-4" (208") PRESTRESSED 187 255 404 12 520 12 637 12 754 12 872 12 <br />192 303 500 732 993 B 1268 14 1E 14 <br />19'-4" (232") PRESTRESSED 162 222 34711 44611 546 12 646 12 74612 <br />166 261 424 616 831 8 105714 1225 14 <br />21'-4" (256") PRESTRESSED 142 198 30611 39311 48011 56711 65411 <br />142 230 369 531 1 713 7 903 13 1046 13 <br />22'-0" (264") PRESTRESSED 137 192 295 10 37811 461 10 54511 �9(1 <br />137 221 354 508 681 7 86113 24'-0" (288") PRESTRESSED 124 175 267 10 341 10 416 10 49 110 5 <br />124 200 316 450 600 7 75612 875 13 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />lcawr-4494" SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14.1T 8RF18.1T SRF22.1T 8RF26-1T 8RF30-IT <br />LENGTH 8RF6-2T 8RF10.2T 8RF14-2T 8RF18-2T BRF22-2T 8RF26-2T 8RF30-2T <br />905 1748 2635 3522 4409 5296 6183 <br />4'-4" (52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />(54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />4'-6' 867 1675 2525 3374 4224 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />T-6" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 2442 2931 1 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15 1640 15 198015 2322 16 <br />395 589 1135 1514 1893 2272 1 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR * SEE NOTE 18 (#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />° • 4 , ' 4 ° < <br />> D > D 4 <br />D D D <br />C C <br />C C C C C C C <br />8F16-1 B/OT 8F16-1 B/1T 8RF14n-1 B/OT 8F8-1 B <br />° 4 <br />Q <br />°0 <br />°D <br />> > <br />°D O C <br />S� D <br />8F12-0B/1T <br />D <br />C C <br />8" PRECAST LINTEL W/ (1#5 HOR CONT <br />BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />C.M.U. <br />0w x oD <br />2cnmwwO <br />V-`nN <br />cn ° <br />a #5REBAR AT <br />ow 0 bO o w a BOTTOM MIN. (1) <br />w < 0 wZ REQ'D <br />�WC7JJJ <br />z W ¢ w 16 GAUGE <br />W ° POWERS STEEL <br />U) � z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />W�-GROUT <br />1/2" CLEAR <br />J <br />C.M.U. <br />`4LO EBAR AT BOTTOM <br />LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8" PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) <br />� � QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />C� <br />z= <br />C C <br />OF <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />AEG 2 y 2022 <br />.i <br />LO <br />Ln <br />r, <br />Z It <br />0 <br />LL <br />w <br />LCN <br />L <br />Loo <br />o <br />co <br />" <br />LL <br />x <br />-.qt <br />1 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS <br />FOR GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />SAFE UPLIFT LOADS FOR 8" PRECAST w/ 2" RECESS DOOR U-LINTELS <br />lcawr-4494" SAFE LOAD - POUNDS PER LINEAR FOOT <br />TYPE 8RF6.1T 8RF10.1T 8RF14.1T 8RF18.1T SRF22.1T 8RF26-1T 8RF30-IT <br />LENGTH 8RF6-2T 8RF10.2T 8RF14-2T 8RF18-2T BRF22-2T 8RF26-2T 8RF30-2T <br />905 1748 2635 3522 4409 5296 6183 <br />4'-4" (52") PRECAST 905 1748 2635 3522 4409 5296 6183 <br />(54") PRECAST 867 1675 2525 3374 4224 5074 5924 <br />4'-6' 867 1675 2525 3374 4224 5074 5924 <br />5'-8" (68") PRECAST 675 1301 1960 2618 3277 3935 4594 <br />675 1301 1960 2618 3277 3935 4594 <br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453 <br />655 1262 1900 2538 3176 3815 4453 <br />6'-8" (80") PRECAST 570 1012 1651 2204 2758 3312 3865 <br />570 1097 1651 2204 2758 3312 3865 <br />T-6" (90") PRECAST 506 797 1462 8 1952 7 2442 6 2931 6 3257 <br />506 967 1462 1952 2442 2931 1 3421 <br />9'-8" (116") PRECAST 395 491 93112 1301 15 1640 15 198015 2322 16 <br />395 589 1135 1514 1893 2272 1 2652 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR * SEE NOTE 18 (#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />° • 4 , ' 4 ° < <br />> D > D 4 <br />D D D <br />C C <br />C C C C C C C <br />8F16-1 B/OT 8F16-1 B/1T 8RF14n-1 B/OT 8F8-1 B <br />° 4 <br />Q <br />°0 <br />°D <br />> > <br />°D O C <br />S� D <br />8F12-0B/1T <br />D <br />C C <br />8" PRECAST LINTEL W/ (1#5 HOR CONT <br />BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />C.M.U. <br />0w x oD <br />2cnmwwO <br />V-`nN <br />cn ° <br />a #5REBAR AT <br />ow 0 bO o w a BOTTOM MIN. (1) <br />w < 0 wZ REQ'D <br />�WC7JJJ <br />z W ¢ w 16 GAUGE <br />W ° POWERS STEEL <br />U) � z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />W�-GROUT <br />1/2" CLEAR <br />J <br />C.M.U. <br />`4LO EBAR AT BOTTOM <br />LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8" PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) <br />� � QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />C� <br />z= <br />C C <br />OF <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />AEG 2 y 2022 <br />.i <br />LO <br />Ln <br />r, <br />Z It <br />0 <br />LL <br />w <br />LCN <br />L <br />Loo <br />o <br />co <br />" <br />LL <br />x <br />-.qt <br />1 <br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR * SEE NOTE 18 (#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR <br />GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 GR40 FIELD ADDED REBAR. SEE NOTE NO. 4 <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION AT ALL LOCATIONS <br />UNLESS NOTED OTHERWISE AT <br />OPENING LOCATION <br />LINTEL SCHEDULE <br />NOTE: <br />REFER TO FLOOR PLANS AND EXTERIOR <br />ELEVATIONS FOR OPENING HEAD HEIGHTS <br />° • 4 , ' 4 ° < <br />> D > D 4 <br />D D D <br />C C <br />C C C C C C C <br />8F16-1 B/OT 8F16-1 B/1T 8RF14n-1 B/OT 8F8-1 B <br />° 4 <br />Q <br />°0 <br />°D <br />> > <br />°D O C <br />S� D <br />8F12-0B/1T <br />D <br />C C <br />8" PRECAST LINTEL W/ (1#5 HOR CONT <br />BAR & (2) COURSES OF 8' K.O. BLOCKS <br />W/ (1) #5 CONT HOR BAR IN EACH - <br />ALL GROUT FILLED <br />ALTERNATE POWERS STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />° 4 1-1/2" CLEAR <br />C.M.U. <br />0w x oD <br />2cnmwwO <br />V-`nN <br />cn ° <br />a #5REBAR AT <br />ow 0 bO o w a BOTTOM MIN. (1) <br />w < 0 wZ REQ'D <br />�WC7JJJ <br />z W ¢ w 16 GAUGE <br />W ° POWERS STEEL <br />U) � z BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF <br />NOTED ON LINTEL PLAN <br />REFER TO MANUFACTURER'S SPECIFICATIONS FOR <br />INSTALLATION. <br />CONTRACTOR TO PROVIDE PROPER PROTECTION OF LINTEL TO <br />PREVENT RUSTING. REFER TO MANUFACTURER'S SPECIFICATIONS <br />IF LINTEL IS SCRATCHED OR DAMAGED REFER TO POWERS STEEL <br />FOR REPAIR. <br />LINTEL DEPTH TO MATCH PRECAST DEPTH. ONE #5 BAR REQUIRED <br />TOP AND BOTTOM OF ALL POWERS STEEL LINTELS. <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D <br />W�-GROUT <br />1/2" CLEAR <br />J <br />C.M.U. <br />`4LO EBAR AT BOTTOM <br />LINTEL CAVITY <br />BOTTOM REINFORCING <br />7-5/8" PROVIDED IN LINTEL <br />ACTUAL (VARIES) <br />8" NOMINAL WIDTH <br />TYPE DESIGNATION <br />F = FILLED WITH GROUT <br />U = UNFILLED <br />RE=RECESSED & FILLED <br />QUANTITY OF #5 REBAR AT <br />BOTTOM OF LINTEL CAVITY <br />8F16-1 B/1 T <br />NOMINAL WIDTH) <br />� � QUANTITY OF #5 <br />NOMINAL HEIGHT REBAR AT TOP <br />z= <br />C� <br />z= <br />C C <br />OF <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />AEG 2 y 2022 <br />.i <br />LO <br />Ln <br />r, <br />Z It <br />0 <br />LL <br />w <br />LCN <br />L <br />Loo <br />o <br />co <br />" <br />LL <br />x <br />-.qt <br />1 <br />1ST FLOOR LINTEL PLAN (ELEVATION B' <br />AEG 2 y 2022 <br />.i <br />LO <br />Ln <br />r, <br />Z It <br />0 <br />LL <br />w <br />LCN <br />L <br />Loo <br />o <br />co <br />" <br />LL <br />x <br />-.qt <br />1 <br />LO <br />Ln <br />r, <br />Z It <br />0 <br />LL <br />w <br />LCN <br />L <br />Loo <br />o <br />co <br />" <br />LL <br />x <br />-.qt <br />1 <br />_ - <br />N <br />N <br />O <br />N <br />, <br />o <br />0 <br />- <br />4 <br />r <br />Q <br />Z <br />W <br />2 <br />O <br />--i <br />W <br />Z <br />Q <br />0 <br />.0 C? <br />W <br />O E:CD � <br />Q <br />QN <br />
The URL can be used to link to this page
Your browser does not support the video tag.