Laserfiche WebLink
PANEL <br />A <br />SURFACEMOUNTED <br />120/240 VOLT 1 PHASE <br />3 WIRE WITH (MOUND <br />60A M.C.B. <br />NEMA 3R <br />NOTES <br />CKT. <br />DESCRIPTION <br />BREAKER <br />A <br />B <br />BREAKER <br />DESCRIPTION <br />CKT. <br />NOTES <br />NO. <br />TRIP <br />POLE <br />XULT <br />VOLT <br />POLE <br />TRIP <br />NO. <br />5 <br />1 <br />GATE MOTOR <br />20 <br />1 <br />120 <br />700 <br />1 200 <br />120 <br />1 <br />20 <br />PEDESTRIAN GATE <br />2 <br />5 <br />5 <br />3 <br />GATE MOTOR <br />20 <br />1 <br />120 <br />700 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17118 <br />19 <br />1 <br />20 <br />CONNECTED VA <br />SYSTEM VOLTS <br />PHASE AMPS <br />900 <br />700 <br />NOTES ( ) <br />DEMAND LOAD <br />0 VA <br />0 VA <br />0 VA <br />0 VA <br />1600 VA <br />0 VA <br />0 VA <br />1600 VA <br />1 7 AMPS <br />120/240V, 1 PHASE <br />8 <br />6 <br />NOTES <br />LOAD TYPE <br />CONNECTED <br />NBC DEMAND <br />1 <br />LIGHTING <br />0 <br />1.25 <br />2 <br />RECEPTACLES <br />0 <br />1 <br />3 <br />AIR CONDITIONING <br />0 <br />0 <br />4 <br />HEATING <br />0 <br />0 <br />5 <br />MISC. NON -CONTINUOUS <br />1600 <br />1 <br />6 <br />CONTINUOUS <br />0 <br />1.25 <br />7 <br />KITCHEN <br />0 <br />0.65 <br />TOTAL <br />120/240V, I PHASE <br />ARC FLASH NOTE <br />THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL <br />SIGNAGE/LABEL5 FOR ARC FLA5H/5HOCK HAZARD FOR ALL <br />SERVICE EQUIPMENT AS PER N.E.G. ART. 110.24 AND NFPA <br />70E. 51GNAGE/LABEL5 MUST SUITABLE TO WITHSTAND THE <br />ENVIRONMENT AND SHALL INCLUDE THE MAXIMUM AVAILABLE <br />FAULT CURRENT, LEVEL OF PPE REQUIRED, APPROACH <br />BOUNDARIES AND DATE OF CALCULATION. <br />PROPOSED POWER CO. <br />TRANSFORMER <br />PROVIDE LETTER WITH <br />THE ACTUAL FAULT CURRENT <br />PROVIDED, BEFORE ORDERING <br />SWITCHGEAR <br />I "C. <br />3-% THWN CU. <br />6 "X6 "X7' <br />CONCRETE POST <br />METER <br />GROUND PER ART. 250 OF THE <br />PANEL A <br />.104 CU. <br />GRD. <br />10 <br />SERVICE RISER DIAGRAM 1201240V I PHASE <br />ELECTRICAL CONSULTING GROUP <br />GENERAL NOTES <br />• CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE <br />HIMSELF WITH EXISTING CONDITIONS PRIOR TO <br />SUBMITTINCs A PROPOSAL. <br />• ALL WORK SHALL BE IN ACCORDANCE WITH THE 2014 <br />EDITION OF THE NATIONAL ELECTRICAL CODE. <br />• ALL CONDUCTORS SHALL BE COPPER,'r1 MINIMUM. <br />• ALL CONDUITS SHALL HAVE A PROPERLY SIZED <br />EQUIPMENT GROUNDING CONDUCTOR <br />• PROVIDE ALL NECESSARY PULL/JUNCTION BOXES, <br />SUPPORTS AND MISC. ITEMS FOR A COMPLETE <br />INSTALLATION. <br />• THE USE OF TYPE 'MC' CABLE MAY BE USED, IF <br />IT MEETS THE REQUIREMENTS OF THE N.E.C. <br />• PROVIDE TYPE WRITTEN PANEL DIRECTORIES. <br />• ALL WIRING SHALL 13E IN A CONTINUOUS CONDUIT SYSTEM. <br />• ALL LIGHT FIXTURES SHALL BE SUPPORTED INDEPENDENTLY <br />OF SUSPENDED CEILINGS. <br />• ELECTRICAL WORK SHALL BE COORDINATED WITH ALL <br />OTHER TRADES. <br />• SWITCHES AND RECEPTACLES SHALL BE 20 AMP COMMERCIAL <br />GRADE AND IVORY IN COLOR PROVIDE MATCHING COVER <br />PLATES. <br />• CONCEAL ALL CONDUITS AND BOXES UNLESS OTHERWISE <br />NOTED. <br />• COORDINATE ALL POWER REQUIREMENTS WITH LOCAL POWER <br />COMPANY ENGINEER <br />• PROVIDE AND MAINTAIN TEMPORARY POWER AND LIGHTNG <br />SYSTEM FOR DURATION OF THE PROJECT. <br />• EMT PITT04GO SHALL 119E DIE CAST SET SCREW. <br />• MAKE FINAL CONNECTIONS TO EQUIPMENT WITH FLEXIBLE <br />METAL CONDUIT. LIQUID Th3WT WHERE EXPOSED TO WEATHER <br />• ALL 1_44ITING CONTROLS TO MEET THE FBC ENERGY CODE <br />bTH EDITION 2011. <br />F.B.C. ENERGY CODE 6TH EDITION 2011 <br />• ALL LIGHTING CONTROLS TO MEET THE FBC ENERGY CODE <br />6TH EDITION 2011. <br />• VOLTAGE DROP CONSIDERATIONS FOR CUSTOMER OWNED <br />SERVICE ENTRANCE AND BRANCH CIRCUIT CONDUCTORS <br />HAVE BEEN INCLUDED IN THE DESIGN OF THE ELECTRICAL <br />SYSTEM AS REQUIRED BY THE 6TH EDITION (2011) FLORIDA <br />ENERGY CONSERVATION CODE REFERENCE CC405.13.1 AND <br />(C405 Z3.2) <br />F.B.C. ENERGY CODE VOLTAGE DROP NOTE <br />FOR BRANCH CIRCUIT CONDUCTORS EVERT' 15' IN <br />LENGTH, THE WIRE SIZE SHALL BE INCREASED ONE <br />WIDE SIZE TO MEET THE PROVISIONS OF NO MORE <br />THAN 3% VOLTAGE DROP ON ANY BRANCH CIRCUIT. <br />Available Fault Current Calculation <br />by:John So kolik Ver. 6.3 <br />Utility Fault Current amperes kVA = 2 imptids0earthlnk.net <br />E = 240 <br />1= WA x 1000 = trans. FLA trans. FLA <br />E <br />[sea = trans. FLA x 100 <br />transformer Z <br />Isca = ampere short-circuit current RMS symmetrical. <br />Point to Point Method <br />Isca = amperes <br />Length (distance) FEET--T <br />'f' factor a 2 x L x I (ASC) <br />N x C X E L-N # conductors per phase <br />Phase conductor constant <br />Volt Line to Line E <br />Neutral conductor constant <br />Multiplier Volt Line toNeutral <br />M= 1 <br />1 + f Line to Line <br />Line to Neutral <br />M = <br />M = <br />Isca x M = fault current at terminals of main disconnect L- L = 0 W amperes <br />Isca x M = fault current at terminals of main disconnect L- N = ----►amperes <br />LEGEND <br />SYMBOL <br />DESCRIPTION <br />MOUNTING/COMMENTS <br />® <br />FLUORESCENT LIGHT FIXTURE <br />SEE LIGHT FIXTURE SCHEDULE <br />1-0 <br />FLUORESCENT STRIP FIXTURE <br />SEE LIGHT FIXTURE SCHEDULE <br />O� <br />FLUORESCENT LAY —IN FIXTURE <br />SEE LIGHT FIXTURE SCHEDULE <br />ElFLUORESCENT <br />LAY —IN FIXTURE <br />SEE LIGHT FIXTURE SCHEDULE <br />EXIT LIGHT, SINGLE OR DOUBLE FACE, <br />® <br />BATTERY BACK UP <br />SEE LIGHT FIXTURE SCHEDULE <br />EMERGENCY LIGHT <br />SEE LIGHT FIXTURE SCHEDULE <br />BATTERY BACK UP <br />INCANDESCENT, HID OR FLUORESCENT <br />WALL MOUNTED FIXTURE <br />SEE LIGHT FIXTURE SCHEDULE <br />INCANDESCENT, HID OR FLUORESCENT <br />CEILING MOUNTED FIXTURE <br />SEE LIGHT FIXTURE SCHEDULE <br />O <br />INCANDESCENT, HID OR FLUORESCENT <br />RECESSED FIXTURE <br />SEE LIGHT FIXTURE SCHEDULE <br />PANELBOARD <br />120/20BV, 3PH <br />SEE PANEL SCHEDULE <br />PANEL.BOARD <br />277/48OVI 3PH <br />SEE PANEL SCHEDULE <br />a <br />DISCONNECT SWITCH <br />SEE PLANS FOR SIZE, TYPE <br />AND VOLTAGE <br />S <br />SINGLE POLE SWITCH <br />44" TO CENTER ABOVE FINISHED <br />120/277V, 20A <br />FLOOR UNLESS OTHERWISE NOTED <br />83 <br />THREE WAY SWITCH <br />44" TO CENTER ABOVE FINISHED <br />120/277V, 20A <br />FLOOR UNLE55 OTHERWISE NOTED <br />64 <br />FOUR WAY SWITCH <br />44" TO CENTER ABOVE FINISHED <br />120/277V, 20A <br />FLOOR UNLE55 OTHERWISE NOTED <br />SPL <br />SINGLE POLE SWITCH WITH PILOT LIGHT <br />44" TO CENTER ABOVE FINISHED <br />120/277V, 20A <br />FLOOR UNLESS OTHERWISE NOTED <br />SM <br />SINGLE POLE MOTOR RATED SWITCH <br />44" TO CENTER ABOVE FINISHED <br />120/277V, 20A <br />FLOOR UNLESS OTHERWISE NOTED <br />SD <br />SINGLE POLE DIMMER SWITCH <br />44" TO CENTER ABOVE FINISHED <br />120V, 20A, VERIFY WATTAGE <br />FLOOR UNLESS OTHERWISE NOTED <br />0 <br />OCCUPANCY SENSOR WATTSTOPPER OR <br />CEILING MOUNT <br />EQUAL. <br />DUPLEX RECEPTACLE <br />18" ABOVE FINISHED FLOOR <br />120V, 20A <br />UNLE55 OTHERWISE NOTED <br />DOUBLE DUPLEX RECEPTACLE <br />18" ABOVE FINISHED FLOOR <br />120V, 20A <br />UNLESS OTHERWISE NOTED <br />GFI1�)= <br />GROUND FAULT RECEPTACLE <br />ABOVE COUNTER TOP <br />120V, 20A (WP-WEATHER PROOF) <br />UNLE55 OTHERWISE NOTED <br />® <br />SPECIAL PURPOSE RECEPTACLE <br />VERIFY MOUNTING HEIGHT AND NEMA <br />208V, 20A <br />CONFIGURATION <br />EXHAUST FAN <br />VERIFY WITH MECHANICAL PLANS <br />JUNCTION BOX <br />VERIFY REQUIREMENTS <br />® <br />CONTROL RELAY <br />SEE PLANS FOR TYPE <br />TELEPHONE OUTLET <br />18" ABOVE FINISHED FLOOR <br />3/4" CONDUIT TO ABOVE CEILING <br />UNLESS OTHERWISE NOTED <br />4 <br />TELEPHONE/DATA OUTLET <br />IS" ABOVE FINISHED FLOOR <br />3/4" CONDUIT TO ABOVE CEILING <br />UNLE55 OTHERWISE NOTED <br />CATV OUTLET <br />18" ABOVE FINISHED FLOOR <br />3/4" CONDUIT TO ABOVE CEILING <br />UNLESS OTHERWISE NOTED <br />NOTE: NOT ALL ITEMS USED. <br />E <br />0 <br />i o <br />N p <br />rfF—•�� � � u a .o <br />w e41 <br />�4 C t <br />W <br />U o U <br />0 <br />w c <br />m <br />31 <br />U <br />r � <br />a <br />5904-A Hampton Oaks Pkwy. J <br />Tampa, Florida 33610 ai a <br />Office: 813-253-5311 <br />Fax:813-464-7629 ti <br />www.HeidtDesign.com <br />M--1 <br />W ^w <br />q:� <br />� <br />w <br />� <br />V <br />a <br />W <br />� <br />0 <br />W <br />a .. <br />WW <br />XO <br />(3- u <br />Vr <br />ctrical <br />nsulting <br />oup, inc. <br />99 HAK*,/ CDR. <br />PALM HARBOR, FL 34683 <br />PI-K727>-409-4358 <br />LIQ #CA7713 PE 52005 <br />CURM T. LATZO <br />aaonacK oaa1 <br />This drawing is signed and sealed by the <br />structural engineer for structural <br />requirements only. Architectural, <br />Electrical and Mechanical requirements <br />and design which are incidental to the <br />structural design in these drawings are <br />not included under the Engineer's Seal. <br />Printed copies of this document are not <br />considered signed and sealed unless <br />bearing the engineer's original signature. <br />U) <br />z <br />W <br />W <br />OU <br />J <br />Z <br />J <br />0 <br />U <br />2 <br />2 <br />z <br />wo- <br />CS <br />O_ <br />L U <br />0 <br />U <br />U <br />~ <br />p <br />W <br />a <br />6 <br />D <br />W <br />D <br />_ <br />U <br />U <br />O <br />O <br />O <br />O <br />O <br />O <br />, <br />I <br />Ol07 <br />N <br />N <br />o <br />N <br />t <br />PROJECT NO: PHC OP 1004 <br />FILE: OAKS AT PASCO ELEC <br />DESIGN BY: Kip <br />DRAWN BY: KJP <br />STATE OF FLORIDA <br />PROFESSIONAL ENGINEER <br />® <br />11111111 <br />CURTIS T. LATZO, P.E. <br />DATE: <br />LICENSE NO. 52005 <br />E-200 <br />m� <br />1z > <br />ocli <br />mUF <br />x gg <br />0SU <br />(1) <br />0 LL <br />Z J <br />J <br />zj <br />0LU Q <br />F aJ <br />�—'w0 <br />�=o <br />-' .f z <br />H 0 <br />Z to <br />mW< <br />z <br />z�W <br />�S= <br />Zm(n <br />o1Uj <br />W <br />H Z <br />W Nd <br />yo <br />ow e <br />0Zo <br />zIzW <br />O yU <br />W <br />,U, <br />W LL Q <br />zw~ <br />�Ww <br />C�Wz <br />jr J 0: <br />JZ> <br />0 <br />U p <br />LD <br />J <br />NLU <br />ooL <br />iw� <br />U� <br />o5 <br />NO <br />IL <br />H I <br />(;W� <br />UUj <br />$= <br />DUB <br />