Laserfiche WebLink
.��..��._..._� rrr �ilWda trvu <br />I <br />I <br />GENERAL INSTALLATION NOTES <br />1 • Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3• Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed L/180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7• 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10• Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12• Lintels loaded simultaneously with verttcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load / . O <br />afe vertical load Safe horizontal load `_ <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE—CRETE, QUALITY, LOTTS <br />LEA <br />8F44 1B/1T8F40 1B/1T 8RF400B/1T 81`321B/1T <br />FORM l4 GROUT SOLID <br />O ' W <br />�U <br />O /5 BAR CONT. <br />8F12-1 B/1T <br />O <br />V' LINTEL DETAIL <br />SCALE = N.T.S. <br />TYPE DESIGNATION <br />#5 REBAR <br />AT TOP <br />F = FILLED WITH <br />MIN, <br />(1) REQ'D <br />GROUT ! U = UNFILLED <br />1/2" <br />c ° <br />R = RECESSED <br />CLEAR <br />QTY. OF #5 <br />O <br />° <br />REBAR @ BOTTOM <br />° <br />OF LINTEL CAVITY <br />c <br />M.u. <br />Q <br />W <br />°a ° <br />8 F 16- B/ 1 T <br />� <br />Q <br />z <br />_ <br />z <br />° < <br />GROUT <br />tNOMINAL. QUANTITY OF <br />A <br />—45 REBAR AT <br />WIDTH #5 REBAR AT <br />c <br />BOTTOM OF <br />TOP <br />LINTEL CAVIT <br />NOMINAL- <br />°-BOTTOM <br />HEIGHT <br />REINFORCING <br />7-5/8"ACTUAL <br />PROVIDED IN <br />8" NOMINAL WIDTH <br />LINTEL <br />(VARIES) <br />MATERIALS <br />cT-f precastiintels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />ALTERNATE POWERS <br />STEEL LINTEL <br />#5 REBAR AT TOP <br />MIN. (1) REQ'D— <br />� J 0 <br />rz�zw <br />W�n_J <br />1.11 <br />IC) <br />cr 0 <br />G LL o W <br />� 00a0� <br />rn�n¢n.L-0 <br />1-1/2" CLEAR <br />.M.U. <br />REBAR AT BOTTOM <br />INDICATED <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />O <br />3'-8" LL <br />O <br />8'-8" LL <br />MIN. O <br />17'-4" LL <br />O <br />4'-6" LL <br />O <br />4'-6" LL <br />O <br />9'-0" LL <br />LINTEL PLAN - ELEV­A <br />SCALE: %4"=1'-O" <br />>I�O <br />C'7 <br />N <br />C0X <br />.. <br />(� LL a <br />.r-- <br />: N <br />(� CD TO <br />L5 <br />Q <br />E <br />Q O <br />r <br />a <br />N y <br />,(2) <br />(1) <br />cv <br />h�O\ <br />iS S I\\\� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />is ni <br />� <br />t� <br />a <br />oo ik <br />N 8 �j <br />- <br />V <br />p�p <br />N Cl LL <br />m # <br />0 <br />0) <br />•� � c0 N * LL W <br />r� LL W rL <br />09 <br />a <br />ai oN7 C) a Y <br />coLL LL 3 aLU <br />(� <br />Z <br />_ �Z HOC <br />@ C V O <br />fY. <br />zi <br />o O ~ w <br />'@ N cD LL' O J <br />Z <br />-_ LL <br />0D N o J a 0 <br />M Z 0: <br />Z� <br />N <br />pv U rviJ <br />W <br />❑00 <br />Z N cg+I <br />z n <br />Q <br />aNam <br />gem <br />W <br />n <br />N <br />z <br />v <br />T('6 <br />W <br />� <br />U <br />� <br />O <br />N <br />�N <br />w S <br />� <br />in <br />(6 <br />i­ <br />U m <br />c <br />W J <br />i <br />¢® <br />._ <br />U 0 <br />N 0 <br />M C <br />sm <br />CD <br />CDw <br />co <br />J <br />u ¢ <br />Z <br />Q <br />[.L <br />Q E <br />E O <br />� o <br />tt <br />os <br />wz <br />Z o <br />Z® <br />❑a <br />w� <br />O <br />N <br />o <br />wo <br />a <br />az <br />ww <br />w <br />st <br />o <br />= <br />U <br />'Y <br />f <br />mo <br />s� <br />Z <br />>� <br />Z <br />m <br />�Z <br />N <br />o <br />zZ <br />g0 <br />d <br />LLa <br />Nw <br />W <br />o� <br />w <br />3 <br />LD r- <br />o <br />'°C.0 a <br />�f <br />Z < <br />° ; <br />'L <br />O <br />�' <br />m <br />cc <br />cc <br />0 <br />co <br />: <br />v <br />T <br />C <br />r <br />^ r U <br />v l O <br />m <br />Cfl <br />� <br />+r <br />� <br />O <br />N <br />CO <br />N <br />LO <br />ai <br />m <br />E <br />T <br />N <br />N <br />o <br />Z <br />Z <br />E N <br />y <br />a <br />E <br />U � <br />a <br />JOB <br />NO: <br />22-02373 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7 <br />