My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6358 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6358 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:03:32 AM
Creation date
2/18/2025 4:32:20 PM
Metadata
Fields
Template:
Building Plans
Street #
6358
Location
Bar S Bar Trl
Contractor
Lennar Homes LLC
Building Plans - Permit #
4646
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 't <br />) <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />With R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />Flzff <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />j4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />FO <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />}� <br />® <br />EXHAUSTFAN <br />,V` <br />EXHAUST FAN/LIGHT COMBINATION <br />rD <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />P� <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�[]sD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANELCENTER <br />01 A14 copper to lights & outlets <br />NEMA t <br />150 AMP/ <br />10 #12 copper to 20 amp ckts <br />200 AMP <br />#10-2 Copper to WH <br />p 10-3 copper to Dryer <br />MO <br />200 amp <br />150 amp <br />UNDERGROUND Dis <br />POWER CO. FEED — <br />INTERSYSTEM <br />BONDING o <br />TERMINATION PER �1 <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />3 <br />Mir ---I <br />-- LL GIF <br />v <br />-,I X <br />N' F �I 1 <br />1 0 �� I 1 <br />DEDICATED GFII in <br />— 'I <br />RECEPTACLE FOR - <br />MICROWAVE RANGE ■ ` o U.C. OUTLET <br />HOOD PER SPECS I Z <br />KIT. , IGF <br />\ O <br />II <br />I SWITCH FOR <br />GFII DISPOSAL <br />I _ <br />LL <br />X <br />N'' FWR <br />ILUa <br />I <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'=1'-0" <br />----LANAI---- ■ <br />/> I <br />I I <br />I I AC PAD <br />WID <br />WP GFI DISC. <br />(CFI I I <br />I �+ <br />qp <br />- \ <br />- - -- OR <br />KFST. DINING <br />LIGHT AS PER A <br />SPECS \\ 5'-0" <br />LIGHT AS PER <br />-- SPECS ■ <br />GF PENDANT <br />LIGHT PER <br />SPECS <br />GREAT RM <br />DEDICATED GFII 1 GFII _ <br />RECEPTACLE FOR 1 "\\ 12 ROUGH -IN f <br />MICROWAVE RANGE a U.C. OUTLET FOR OPT. <br />HOOD PER SPECS o Z (/ FAN/LIGHT <br />- I Z. o I I GF <br />a SWITCH FOR OPT. CLG. FAN/ <br />DISPOSAL GF\LIGHT PRE -WIRE <br />II — I — — <br />I II <br />o <br />• I LL <br />LL M GF <br />0 <br />2-8" &4 1'-10" I I \ <br />i loll <br />3 / t <br />■ -A fcH <br />Ti,)L S I I I I I <br />S I CHIABWI I <br />� <br />I I I I I I I 1 1 II I I I I I <br />GFI @ 44" FOYER <br />w W.H. / A.F.F. <br />- <br />c / G 0 <br />LQo ■ J I 1 <br />I— / <br />xU— ZUJ <br />>_jm Pa \ __ <br />U Q I __ <br />0U \\ GARAGE / WP DB <br />WP " U LIGHT ASt!T <br />I I <br />GFI w W PER SPECS GFI <br />■ ' w .,GARAGE / <br />GARAG I I <br />GFI ENTRY <br />I I <br />------------------------------� II <br />9 I I I I <br />r i I i i t <br />IRRIGATION GFI I I ■-------- <br />I @ 44" A.F.F. ■ -------- <br />I ' I <br />I \ I <br />I I <br />I \ I <br />I \ I <br />------------------------------ <br />•■-----------------------------�, ■■ <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS _ <br />r_ _�i <br />11 ALT 11 <br />AC PAD I I <br />Il 11 <br />OPT. <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE / CABLE <br />AND OUTLET AT TECH <br />------------------� <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />1.5" VTR 3" VTR III <br />III, I <br />�I I <br />I I <br />I I <br />I I <br />I r� <br />3" VTR III- <br />I � I <br />I I I I I <br />3" <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN - ELEV-A <br />SCALE: %4'=1'-0" <br />-0 <br />N :F� O <br />N _ m X <br />N (a tl p <br />- OI <br />Ct ) <br />- U <br />a t <br />,D <br />-L 4- LIJ1 <br />fV <br />CV <br />0 <br />N <br />fV <br />N <br />N <br />O <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />to Q <br />FW- of Z� <br />a o GO <br />co Nn# <br />0 7 co LO 05# LL W <br />coNV - LL a <br />Y <br />Q J ri LL nW 5 <br />Z f0�°' ox� <br />O w <br />'tp N o M O <br />O'a <br />��W <br />r- Z <br />Z NMX fnO <br />VILUN0 Z <br />W ❑ ❑ ❑ <br />V M � <br />Z >ti cn <br />0 <br />co <br />Z � N <br />z o � <br />Q <br />r <br />m <br />Q) cD o <br />+.j <br />(is w <br />� <br />U <br />0 <br />�v I [y N <br />w' <br />n (f� r— r <br />ru <br />U <br />E <br />I <br />U o Y+ <br />C U) W <br />Q Y <br />Or <br />• <br />N <br />o <br />co <br />c� <br />M <br />a <br />N <br />Z <br />< <br />L <br />ce E <br />E o <br />z o <br />w <br />> N <br />z" <br />a <br />❑a <br />Z <br />U <br />H <br />o C <br />N rII <br />x <br />a U <br />o <br />a o <br />Do <br />0 Q <br />az <br />w <br />i <br />tt � <br />_ M <br />CON <br />o <br />o <br />Z <br />Z. <br />Q) <br />Cn J <br />m <br />¢b <br />< w <br />zZ <br />a`�i 3 <br />0 <br />g° <br />W <br />Q <br />LLa <br />N Z <br />NLL <br />�z <br />3 <br />=� <br />Jo <br />O <br />GO <br />w <br />O¢ <br />�'o <br />d <br />O_ <br />C <br />a <br />zT3 <br />0 <br />C O <br />i <br />` <br />> L0 <br />J <br />0 <br />rn <br />m <br />0 <br />(Q <br />CV <br />VJ <br />� <br />CO <br />� <br />N <br />N <br />LO <br />Q <br />T <br />N <br />ui <br />m <br />w N <br />r ti N <br />o <br />Z <br />Z <br />E CV <br />ca <br />m <br />a <br />v <br />cc <br />ci _j d o <br />c <br />CD <br />JOB <br />NO: 22-02373 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />