My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6362 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6362 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 9:35:35 AM
Creation date
2/18/2025 4:32:56 PM
Metadata
Fields
Template:
Building Plans
Street #
6362
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
6071
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Z <br />) <br />.r.r <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BL USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12, Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />Felwkp. <br />G.F.L GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />?4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />FO HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />© ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />j-�- TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />TV TELEVISION (OPTIONAL) <br />TV 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & 160" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />_mw-j DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />L J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />T OPT. CEILING FAN <br />w (1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER ,/ •^'"'� <br />#14 to lights & outlets <br />NEMA 1 10 #12 to appliances and GPI { <br />0 AMP/ <br />200 AMP 01 #10 to WH <br />10 #8 to Range <br />-T <br />MAIN <br />0 <br />200 amp <br />150 amp <br />UNDERGROUND IDIs <br />SERVICE BY POWER CO.'- ,- ,,. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER XITI <br />200=4/0 in 2" Conduit <br />Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />�I ALT 11 <br />I I AC PAD <br />I� �I <br />�= ==WP <br />OPT. <br />AC PAD <br />DISC. WID <br />GFI <br />' <br />I <br />GIFI <br />I / <br />Ak <br />I <br />I I <br />DINING 1 FIT <br />LI; Hl AS PER - <br />5'-0"o / SPECS <br />it ! i I <br />LIGHT AS PER <br />SPECS ! _ <br />PENDANT <br />LIGHT PER - <br />SPECS I j <br />II ' <br />GFI- I <br />GREAT R M 11�.�= ©1 <br />12 <br />-© ROUGH -IN U.C. OUTLET <br />FOR OPT. I III i- t <br />FAN/LIGHT l/ SWITCH FOR FI I o � IQ I- _ <br />OPT. CLG. DISPOSAL <br />FAN/ 1 <br />LIGHT PRE -WIRE <br />II <br />GFI <br />' C.M ». t I <br />,µ, <br />6 I <br />CH <br />! I IC A Q D --I <br />I I I I I II I I' <br />IWI I I I I I I 410� <br />I I I I I II I I I I I 1 J <br />_ <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN_ <br />SCALE: Y4'=1'-0" <br />y�II�DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />OWNER <br />BEDROOM <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE ` l <br />�I <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />'% <br />6/ <br />BEDROOM 4 <br />s.o. <br />_I <br />IC <br />U Y; GFI 144" ` \ <br />-- A.F.F. 1 W,H. <br />H <br />\ <br />IW- s <br />_ I <br />LU +� <br />OCr <br />ZW <br />ads <br />U Q <br />I� GARAGE <br />DB WP <br />- <br />LIGHT AS <br />w <br />I I GFI PER SPECS UJI W <br />GARAG E,� W <br />• <br />- <br />I I <br />I <br />r <br />I I 1 GARAGE <br />— <br />DOOR <br />ENTRY == I GFI <br />,- --------------------------------, <br />10 <br />_ <br />-- _ _.....-.. _ — IRRIGATION GFI <br />I @ 44" A.F.F. <br />I I ' I <br />� <br />-------------------�---------------- <br />_---__-----COARCHT-fGRTS---------- <br />OR PREWIRE AS <br />-• , PER SPECS ..-~ <br />R/A <br />OPT, CLG. FAN/ <br />LIGHT PRE -WIRE <br />BEDROOM 2 <br />11 <br />----------------� <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I I <br />tit <br />X <br />WIC <br />601illum <br />W Lj <br />12 <br />I OPT, CLG. FAN/ <br />LIGHT PRE -WIRE <br />BEDROOM 3 <br />I I <br />I I <br />I I <br />I I <br />I l <br />I I <br />I I <br />I I <br />L---------r-----------------------------------J <br />III 3" VTR 1.5" VTR <br />I ` <br />I I <br />I I <br />I I <br />I <br />� I I <br />`III 3" VTR <br />I— <br />I <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE /CABLE PLUMBING <br />AND OUTLET AT TECH RISER <br />CENTER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />GFI @ <br />44" A.F.F. <br />ELECTRICAL PLAN - ELEV A <br />SCALE: Y4"=1'-0" <br />rap <br />C'9 <br />" <br />w 'n <br />w <br />a <br />.� <br />CL C" <br />� ts� t•:.9 �.I <br />r <br />low <br />M <br />cv <br />ca <br />cv <br />00 <br />Nr,';3i) <br />:u <br />• <br />_ <br />''" <br />,/ <br />e,I,-��. <br />'l�yo <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineers signature and seal. <br />0 <br />h <br />t� <br />QE �N <br />m8 <br />q <br />S <br />_ <br />o <br />aLOIVNLLw <br />W <br />(IjM <br />0v a a <br />C13 <br />Mu-u. <br />a <br />O <br />_ <br />L <br />o � o <br />�' <br />'� <br />_ <br />CV c0 0] 4 <br />{W{I <br />O�M;; <br />(1) <br />FJ- <br />$ F- Z <br />IL <br />N <br />Lu <br />N Z O H <br />� <br />OU ❑©❑ <br />W <br />�r <br />2- <br />V'n <br /><c <br />CU <br />�^ <br />s <br />�- <br />w <br />C. <br />U <br />w <br />8Juft <br />(Ct�� <br />,R <br />(.1.J <br />f --• <br />l�D <br />J � <br />L <br />K ice, , <br />a <br />Eo <br />y5 <br />Z <br />W <br />W <br />ra <br />�a <br />g <br />df <br />N� <br />s <br />CD <br />m <br />CU <br />c� <br />Co LO <br />N <br />O <br />Li.Ina0' <br />VJ <br />JCN <br />O <br />L <br />.�. <br />O <br />� <br />co <br />N <br />o <br />(CY)�, <br />c3 <br />r <br />�--- <br />E <br />M <br />00 <br />Z <br />co <br />E N <br />E <br />`m <br />E <br />C <br />JOB <br />NO: <br />23-02469 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />