My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6370 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6370 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 10:26:35 AM
Creation date
2/18/2025 4:33:51 PM
Metadata
Fields
Template:
Building Plans
Street #
6370
Location
Bar S Bar Trl
Contractor
Lennar Homes LLC
Building Plans - Permit #
4636
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
110 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A1200A INDOOR <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />copper to lights & outlets <br />copper to 20 amp ckts <br />.2 copper to WH <br />.3 copper to Dryer <br />or 4/0 SER Alu <br />UNDERGROUND <br />DisconnL#4GROUNDING <br />POWER CO. FEED <br />INTERSYSTEM <br />Bare Cu Ground <br />BONDING <br />WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.WEATHERPROOF DUPLEX OUTLET <br />P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />� 4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />a HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />® EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />rD ELECTRIC DOOR OPERATOR (OPTIONAL) <br />Ft-,H I CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />DI3 PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />0 TELEVISION (OPTIONAL) <br />2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />]M ELECTRIC METER <br />_Q ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />C� J <br />'�\ \ILZ/ /? <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />III- 1.5" VTR <br />'I <br />I <br />I <br />I <br />� I <br />� I <br />I I <br />I I I I <br />PLUMBING RISER_ <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />DEDICATED <br />RECEPTACLI <br />FOR MICRO <br />RANGE HOO <br />PER SPECS <br />II 3 <br />II � <br />II � <br />FOR DISPOSAL <br />1■I <br />L1 <br />Q <br />n <br />OPTIONAL LIGHTING <br />SCALE: %4'=1'-0" <br />I I � <br />I I � <br />- - - - - - - - - <br />I I I ♦�� ROUGH -IN FOR <br />I I �'" OPT. CLG. FAN, <br />I I I G LIGHT PRE -WIRE) <br />BEDROOM 2 ' <br />I I I <br />I I I <br />I I <br />I I I <br />L-----------I I <br />I I <br />I <br />I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I _ I <br />IL--— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J <br />AC PAD <br />WP <br />GFI <br />DISC. <br />■ ■ <br />I <br />DINING <br />f <br />I <br />IN <br />dill <br />■ FAMILY <br />5'-8" <br />4//' 1 'Zzl, mi <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ DEDICATED <br />LIGHT PRE -WIRE I RECEPTACLE <br />/ FOR MICROWAVE <br />■ RANGE HOOD <br />PER SPECS <br />� CM <br />■ / <br />ITOILIGHTS 1 I I <br />OPEN I j j ]AND SWITCH j I <br />TO ABV. I I I IABOVE <br />I I I I I I I I <br />— — — — — <br />ly <br />FOYER GFI <br />@ 44" <br />■ ■ ___ <br />■ <br />____ ■ ■ <br />I <br />LANAI I■ <br />ROUGH -IN FOR <br />OPT. CLG. FA / <br />WP <br />G11 LIGHT PRE -WE <br />IA <br />I <br />WL _/ <br />NOOK <br />/ M <br />PENDANT PER SPEC <br />ram` GFI <br />VGI o I <br />L_--J <br />/ � I <br />I I � 111 <br />iI I `O*a'27��- -5'-8'\—� 3'-1" <br />A.F.F. / I <br />t <br />■■ <br />IDB <br />NP <br />i/ <br />I I PC - ( GARAGE <br />I C- - - <br />- LIGHT AS <br />(ENTRY LIG11T PER SPECS o <br />■ AS PER SFYECS �+ <br />WD. <br />■ <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET <br />If II <br />II ALT II <br />■ I I AC PAD <br />Il 11 <br />WP <br />GFI <br />■ DISC. <br />■ <br />■ <br />LU <br />W.H. <br />- <br />W S <br />J <br />LU <br />LL 0 LU <br />Z LU <br />- <br />U J <br />>-im <br />Qa- <br />UQ <br />0U <br />U <br />■ <br />>w <br />/ GARAGE DOOR <br />■ GFI ■ <br />I I GARAGE � ■ <br />I I <br />■ j q IRRIGATION] <br />GFI @ 44"1 <br />A.F.F.1 <br />I I - <br />I - <br />I I <br />-------------------- <br />■ ■■ ---- ■ ■ <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />0 <br />In <br />ELECTRICAL PLANS — ELEV-13 <br />.0 <br />O j 0 <br />aUN <br />amx <br />Cu U- 0- <br />In 0 <br />E f <br />0 5 i <br />1 <br />- 0 a) <br />j 1 <br />> _� T <br />> L r C <br />_ u <br />c u- 0 O <br />0 LU <br />5 rt <br />i <br />N <br />N <br />O <br />N <br />\ o <br />c*-> <br />O <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />NCD <br />W v E 00 <br />O 28 <br />a <br />N tV C' N J <br />V a) r- J LL <br />O -5LO 00-N6 J ,Q ILL d <br />W M v LL (L Y <br />Q @U_ILL wad <br />o <br />Z_ v o <br />1 <br />W in�T ¢aa <br />a <br />= 00 to M Z Y O <br />LL <br />ZpU04 <br />U�vvi <br />W ❑ ❑ ❑ <br />Z N (h <br />0 0 <br />z <br />Z <br />a <br />—, — <br />0-G <br />r, <br />U) <br />f) Z <br />c9 0 <br />Q) u <br />4-, <br />(6 w m <br />Q A <br />N <br />U <br />0 c N <br />�� U) <br />c'n <br />tx+u <br />(� <br />U c <br />w <br />T f— E <br />U o' <br />QCIO <br />N <br />W <br />C> <br />coM <br />w <br />Z <br />0 <br />a <br />E OV <br />�� <br />Z® <br />oa <br />¢o <br />¢4 <br />w¢ <br />jto <br />� <br />0 <br />Z <br />o ru <br />Q% <br />¢= <br />0 <br />wz <br />L <br />MI <br />N <br />¢❑ <br />ox�Z <br />U <br />�m <br />mE <br />O <br />Z <br />ZC/.)� <br />C')J>> <br />wee <br />'aw <br />fm <br />>I <br />O <br />aU <br />_ <br />W <br />U <br />ao <br />�~ <br />NE <br />3 <br />o <br />O <br />C.0 <br />'0 <br />a <br />_ <br />sC <br />� C <br />rn <br />�o <br />c� <br />a� <br />L <br />� <br />v <br />T <br />m <br />O <br />LO <br />0) <br />N <br />N <br />LO <br />N <br />r <br />Q N <br />r <br />E <br />m <br />M � <br />� <br />.. <br />o <br />Z <br />z <br />E N m <br />m` <br />cc <br />a- <br />U J Q 0 1 <br />—1 <br />JOB <br />NO: 22-02375 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />