Laserfiche WebLink
INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1.1 <br />FIRST FLOOR PLAN <br />1.2 <br />SECOND FLOOR PLAN <br />2.1 <br />EXTERIOR ELEVATIONS - FRONT & LEFT <br />N l; <br />� 1;JCZ <br />2.2 <br />EXTERIOR ELEVATIONS - REAR & RIGHT <br />- - <br />3 <br />ELECTRICAL PLAN <br />4 <br />ROOF PLAN <br />5 <br />FOUNDATION PLAN <br />6.1 <br />FLOOR FRAMING PLAN <br />6.2 <br />ROOF FRAMING PLAN <br />T <br />T _ <br />7 <br />SN <br />LINTEL PLAN & DETAILS <br />ST RUCTURAL NOTES <br />ABBREVIATIONS <br />-- <br />1 <br />SN1 <br />S3 <br />DETAILS <br />DETAILS <br />AB or A.B. Anchor Bolt <br />FIX or FXD Fixed <br />PWDR or Pwd. Powder Room <br />ABV or Abv. <br />Above <br />FLR or Flr. Floor <br />RA or R/A or R.A. <br />Return Air <br />S4 <br />DETAILS <br />AC or A/C <br />Air -Conditioner <br />FLR SYS or Ar Sys Floor System <br />RAD or Rod. <br />Radius <br />--- <br />- — - - -- -- - — <br />ADJ orADJ. <br />Adjustable <br />FOM or F.O.M. Face Of Masonry <br />RAG or Rag. <br />Return Air Grill <br />S5 <br />DETAILS <br />AFF or A.F.F. <br />Above Finished Floor <br />FP or F.P. Fireplace <br />REC or Rec. <br />Recessed <br />S6M <br />DETAILS <br />AHU or A.H.U. <br />Air Handler Unit <br />FR DR French Door <br />RECEPT <br />Receptacle <br />ALTorALT. <br />Altemate <br />FRT Front <br />REF or Ref. <br />Refrigerator <br />ST <br />STAIR DETAILS <br />Be <br />Base Cabinet <br />FT or Ft. Foot/ Feet <br />REINF <br />Reinforcing <br />SS <br />BF <br />B'rfotd Door <br />FTG or Ftg. Footing <br />READ or Req'd. <br />Required <br />RETROFIT DETAILS__ <br />BK SH or Bk Sh <br />Bookshelf <br />FXD GL Fixed Glass <br />RM or Rm. <br />Room <br />- <br />D1 <br />SECTIONS &DETAILS <br />BLK or BLK. <br />Block <br />GALV or Galv. Galvanized <br />RND or Rnd. <br />Round <br />— <br />L— <br />BLW or BLW. <br />Below <br />GC or G.C. General Contractor <br />RO or R.O. <br />Rough Opening <br />- �� <br />\ <br />D2 <br />SECTIONS & DETAILS <br />BM or Bm. <br />Beam <br />GFI or G.F.I. Ground Fault Interrupter <br />RS, R/S, R/SH or R&S <br />Rod and Shelf <br />!_ ' - <br />J - "" -%" � --�` � <br />�'� , <br />WP <br />WATERPROOFING DETAILS <br />BOT or Bot. <br />Bottom <br />GT or G.T. Girder Truss <br />SD or SO. <br />Smoke Detector <br />` <br />-- - -- - ---- - <br />BP or B.P. <br />Bypass (door) <br />GYP BD or Gyp. Bd. Gypsum Board <br />SGD <br />Sliding Glass Door <br />'J '- <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />BRG or BRG. <br />Bearing <br />HB Hose Bibb <br />SH or Sh. <br />Shelves--- <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />C <br />Carpet <br />HDR or Hdr. Header <br />SHT <br />Sheet <br />�G <br />CAB <br />Cabinet <br />HGTorHgt. Height <br />SHWRorShwr. <br />Shower <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />CIR or Cir. <br />Circle <br />HH or H.H. Hand Held (plumbing faucet) <br />SL or S.L. <br />Side Lights <br />- <br />SH1.0 <br />- <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CJ or r C <br />CLG or Clg. <br />Control Joint <br />Ceiling <br />HS Horizontal <br />HS Hard Surface (flooring) <br />SPECS SPECS. <br />SPF or S.P.F. <br />Spruce Pine <br />Spruce Pine Fir <br />,� _ ,� <br />� C � <br />rr <br />SH1.1 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CMU <br />COFF or Coff. <br />Concrete Masonry Unit <br />Coffered or Tray Ceiling <br />ILO In Lieu Of <br />INSUL Insul. Insulation <br />. <br />SQ FT or SF or S.F. <br />SQ or Sq. <br />Square Foot (feet) <br />Square <br />U <br />EI I IEl <br />f E-: <br />El <br />.._ <br />SH1.2 <br />- <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />- <br />COL or Col. <br />Column <br />INTorint. Interior <br />nt <br />STO <br />Storage <br />J I <br />SH1.3 <br />- -- - --- - <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />COMM or Comm. <br />COMP or Comp. <br />Community <br />Compressor <br />KIWALL or K/Wall Kneewall <br />KS or K.S. Knee Space <br />SW or S.W. <br />SYP or S.Y.P. <br />Shear Wall <br />Southern Yellow Pine <br />= <br />11] F E E:1 1 ---1 <br />SH1.4 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CONN or CONN. <br />Connection <br />LAUN or Laun. Laundry <br />TB <br />Towel Bar <br />SH1.5 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CONT or Cont. <br />CT or C.T. <br />Continuous <br />Ceramic Tile <br />LAV or Lay. Lavatory <br />LF or L.F. Linear Ft. <br />TEMP or Temp. <br />THIKN or Thik'n. <br />Tempered <br />Thicken <br />I <br />D or D. <br />Dryer <br />LL Lintel Length <br />TOB or T.O.B. <br />Top of Block <br />1 L�� 1 L� <br />DB <br />Door Bell <br />LT Laundry Tub <br />TOM or T.O.M. <br />Top of Masonry <br />DBL or Dbl. <br />Double <br />MAS or Mas. Masonry <br />TOP or T.O.P. <br />Top of Plate <br />DCF <br />Decorative Cementitious Finish <br />MAX or Max Maximum <br />TP <br />Toilet Pa mr Holder <br />DEC or Dec. <br />Decorative <br />MC Medicine Cabinet <br />TR <br />Towel Ring <br />DED or Ded. <br />Dedicated (outlet) <br />MFR or Mfr. Manufacturer <br />TRANS WOW or Trans. <br />Transom Window <br />DIA or Dia. <br />Diameter <br />MGT Management (room) <br />TYP or Typ. <br />Typical <br />DISP or Disp. <br />Disposal <br />MIN or Min Minimum <br />UC or u.c. <br />Under" unter <br />DIST or Dist. <br />Distance <br />MIR or Mir. Mirror <br />UCL <br />Under '.oinet Lighting <br />- <br />- -- - - -- <br />DMF <br />Decorative Masonry Finish <br />ML or M.L. Microlam <br />LINO or U.N.O. <br />Unlebs Aed Otherwise <br />DS or D.S. <br />Drawer Stack <br />MONO or Mono Monolithic <br />V or v. <br />Valve (shower or tub/shower) <br />DTL <br />Detail <br />MW or MICRO or Micro. Microwave <br />VB <br />Vanity Base <br />------ <br />DV or D.V. <br />Dryer Vent <br />NTS or N.T.S. Not to Scale <br />VERT or Vert. <br />Vertical <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />DVP or D.V.P. Diverter Valve (plumbing) <br />OE or O.E. Owner's Entry <br />VL orV.L. Versalam <br />DW or D.W. <br />Dishwasher <br />OPNG or Opn'g. Opening <br />VTR or VTE <br />Vent through Roof / Exterior <br />FOR SINGLE STORY HOMES <br />EA or Ea. <br />Each <br />OPT or Opt Optional <br />W or w <br />Washer <br />ELEC or Elec. <br />Electrical <br />PC Pull Chain <br />W/ or w/ <br />With <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />ELEVorElev. <br />Elevation <br />PEDorPed. Pedestal <br />WA or WA. <br />Wedge Anchor <br />EQ <br />Equal <br />PH Phone <br />WC or W/C or W.C. <br />Water Closet (toilet) <br />FOR 2 STORY HOMES <br />EW or E.W. <br />Each Way <br />PKT or Pkt Pocket (Door) <br />WD or Wd <br />Wood <br />THIS DRAWING AND DESIGN IS VALID <br />EXPorExp. <br />Expansion <br />PLorP.L. Parallam <br />WDWHDRorWDW.HDR. <br />Window Header <br />EXT or Ext. <br />Exterior <br />PLF Pounds per linear foot <br />WH or W.H. <br />Water Heater <br />FOR 12 MONTHS AFTER THE DATE IT <br />FBC <br />Florida Building Code <br />PLNT SHLF or PIt. Sh. Plant Shelf <br />WIC or W.I.C. <br />Walk-in Closet <br />IS SIGNED AND SEALED OR WHILE <br />FDN or Fdn. <br />Foundation <br />PLT HT or Pit. Ht, Plate Height <br />WM or W.M. <br />Wall Mounted (plumbing fixture) <br />CURRENT CODE IS VALID <br />FG <br />Fiberglass (Shower Pan) <br />PSF Pounds per square foot <br />WP <br />WaterProof(ing) <br />CODE REFERENCES ARE SUMMARIES <br />FIN <br />Finished <br />PT or P.T. Pressure Treated <br />WS <br />Water Softener <br />FIN FLR or FF or Fin. Fir. <br />Finished Floor <br />PW or P.W. Pre -wire <br />WWF <br />Welded Are Fabric (Mesh) <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />PLAN <br />REVISIONS <br />COMPLETE CODE INFORMATION. <br />DATE VERSION DESCRIPTION <br />Notice to Builder &All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />08/23/12 <br />1.00 <br />NEW BASE PLAN <br />documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />07/30/ 15 <br />1.1 <br />2015 NEW CODE UPDATE <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />05/09/18 <br />2.0 <br />FBC 2017 CODE UPDATES <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />12/19/20 <br />3.0 <br />FBC 2020 CODE UPDATES <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineerwithout <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />Control of Construction Site <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />ling and uencing of work, obsite safety, and <br />Iventiation <br />of theubuilding and thereby shall not,be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/homeowner <br />are necessary for the future life of this home. Care must be taken <br />to check windows and doors for caulking, remove leaves and <br />2074 <br />debris off roofs, make sure that water flow is away from the <br />house and have your home repainted every 3 - 5 years to protect <br />the coatings. The designer and engineer of record are not <br />responsible for the upkeep of the home and will not be held <br />liable for instances that may occur over the normal life of the <br />home without proper maintenance. <br />ti o <br />`'U� <br />N <br />m N <br />X <br />o <br />co <br />O �- <br />Np <br />N <br />(� N <br />-0 N Y <br />Q <br />N <br />c <br />cthr)E Q <br />Q n ca <br />> 0 -0 <br />O 0-0 <br />E <br />_ C <br />tt3 N O O <br />j � V <br />Q C Cif <br />> > FL•� LU <br />«=Wn, <br />i <br />_ CJ• \ 1� �Q <br />f F L �. <br />�'If O�>E (33' <br />if' (141111111 l l 0 0N <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a U9° <br />8� <br />H`cep ° <br />N 6 C J LJL <br />tnNo� -Lu a a <br />�i aj M V' S�� <br />re LL LL a YJ S <br />0 <br />Z - 0° <br />NCD LLO-J <br />oo <br />W �a a <br />CLZ °D <br />-J <br />N to Z K co 0 <br />ZO U 0 <br />W ❑�❑ <br />v <br />C <br />z 8 <br />z <br />E3 <br />Z P'I <br />U) <br />�4-1 LL <br />IF <br />N M w <br />Ou, 8 <br />N c <br />_ co <br />�V)co <br />w <br />'® 8 <br />_ <br />U <br />_Q <br />Q � <br />o <br />w <br />J <br />LL <br />o <br />ao <br />h� <br />�a <br />a <br />0 <br />E <br />� <br />� <br />M� <br />a <br />�o <br />zFT <br />S E <br />N <br />C' <br />a <br />&� <br />L <br />02 <br />Z <br />NJ <br />z <br />W-Z <br />.J <br />�I <br />J <br />M <br />rn <br />m <br />co d' <br />T <br />O <br />T <br />U) <br />in <br />ll) <br />N <br />Q N <br />r <br />T <br />ci <br />C1V <br />' " N <br />c <br />Z <br />z <br />Z <br />� <br />E <br />c <br />Q.0 <br />Q p <br />JOB <br />NO: 22-02351 <br />SCALE : AS NOTED <br />SHEET NO. <br />C S <br />