My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6417 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6417 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 11:04:32 AM
Creation date
2/18/2025 4:35:07 PM
Metadata
Fields
Template:
Building Plans
Street #
6417
Location
Beverly Hills Dr
Contractor
Lennar Home
Building Plans - Permit #
4150
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
34 <br />W <br />I <br />7t <br />N <br />Q <br />N <br />B <br />I <br />2 <br />'a <br />3 <br />t <br />a <br />0 <br />E <br />i <br />19 <br />i <br />I <br />Y <br />5 <br />t7_ <br />M <br />Na <br />0 <br />M <br />M <br />z <br />U <br />W <br />THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAxl-1t2" LONG (3/4%1" CROWN) <br />L''. 1777_* .'.'.'.' <br />..................... ...... .. <br />...... �:::::.:.:...:..::::.::..:....:...:::: <br />i3 I)� <br />WALL SHEATHING <br />MAX <br />STAPLES @ 6" O.C. VERT BETWEEN F. 16GAx1-1/2" LONG (3/4"-1" <br />STUDS (NOTED THUS:—) - OFFSET CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 0 0 0 <br />co <br />5'-0" <br />STUB -OUT FOR " <br />0 1'-0o o in <br />GAS METER e v <br />O o <br />CV = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) -12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />'IT-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />164" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood anels or 2 x _ <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2x + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x lumber <br />Double 2 x lumber <br />FILL CELL STD. 900 HOOK BOND BEAM <br />SIMPSON MGT <br />w/(22)10d 1 <br />w NAILS TYP. `—GIRDER TRUSS <br />STD. 90° .� �C CONT. #5 <br />CONT.#5 HOOK BAR 2X TOP PLATE <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN .N <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />COLUMN AND ;:� =—SHEATHING PER PLAN <br />CONNECTION <br />f• <br />1.. TJI TO BE CUT TO ALLOW <br />.-T FOR BLOCKINGITJI <br />MASONRY WALL OR <br />.0 ll INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />L Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. }Small gap <br />2" max. <br />2" min. <br />4" max. <br />� <br />i <br />+ <br />I <br />Web Stiffener Fastener Schedule <br />Series De tJoist - he End Intermeationdiate l' <br />® 9-1/2"_ 2-8d 2-8d_ <br />BCI 5000s 11-7/8" 2-8d 3-8d <br />14" i 2-8d 5- <br />Clinch nails - 9-1/2" 2-8d 2-8d <br />whenpossible BC16000s® 11-7/8" 2-8d 3-8d <br />BCI6500s 14" 2-8d 5-8d <br />1 Support back of web during nailing to prevent damage to V 16" 2-8d 6-8d <br />PPo 9 9 P 9 11-7/8 2-8d 3-8d <br />web -flange connection. - BCI 60s® 14" 2-8d 5-8d <br />-- <br />2) Block solid between joists for full length of span. Tight fit - 16" 2-8d I 6-8d <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 11-7/8" 3-16d3-16d_ <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. gCl 90s® 14" 5-16 5 16d <br />required when indicated or 4' max. 16 " <br />6 _ <br />16d1 6 16d <br />2x :CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. I- <br />OF THE JOIST ASA REQUIRED LEAVINGY" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouth cuts. N.T.S. <br />Under 2nd floor column w/ loads <br />N.T.S. hi her than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 pff max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.* <br />local building <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or-20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />+ <br />Boise Joist Blocking <br />tlse T' 11(ldl nails at R" n.c- <br />Provide adequate bearing <br />for each lapped joist. <br />10dnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />g <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over 1� <br />blocking and wall or beam below.* <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration.- <br />6�� A 1 2" ROUND HOLE MAY 6�� 6,� 0 NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT, <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y2 ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y2" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION, USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Joist hanger <br />5/8" R <br />THRU <br />BOLT <br />I.0 <br />SIMPS( <br />w/(22)• <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />BUILT—UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) —.I 11—I�I �J�I <br />Nail with 10-10d nails. <br />Install tight to top flange. r�; <br />SLEEVE THRU STEM <br />XX SEE PLAN FOR--'•• • FOUNDATION INFO ` a <br />STEM FOUNDATION <br />! \ W Filler block, <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />— 1/4"-2"gap <br />f ^� Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />fi requirements <br />-0.6 X Joist <br />o depth <br />I <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />REINF. SEE PLAN <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° ° (WHEN <br />w/ (18)10d x 1 1/2" REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />r — a G <br />yl\i- <br />1 <br />° 4 <br />*n �TTT�TfI'— • <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0"-PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />4 4 <br />O 4 <br />�. O .4 4 <br />4 <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />7-G o 4 4 <br />�---_ — a 4 4v L <br />a d <br />44 4 <br />'d <br />SEE FND. PLN. <br />SIZE & REINF. <br />"t3 <br />v O <br />> O. <br />X <br />Qm <br />M Ll. CL <br />� N to <br />V Y <br />c <br />_ <br />O <br />N 3 � 0 <br />0 <br />w 0) CL -0 <br />7 IJ- <br />Q� E C <br />U.)O O <br />< C U <br />oV.! <br />>�� <br />tttilDi Il1Ftl/�,��!'' <br />, <br />4 <br />\l� P•r�'• cE '••� <br />Jwit <br />�v ►\rLlb -� <br />Q �J rr <br />= :� : ,�o • OF o <br />' <br />C <br />c� <br />• <br />FLOIko <br />•�. <br />lllllll111'tttt��� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residentlal 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />m 8N � <br />= O J <br />(� Y aCo cr u <br />L5 <br />- 4 w ao � vc <br />to <br />0 in-�1? --wa <br />� My LLax <br />a LLLL <br />1��00LL a` <br />0 <br />to 0 0 f- <br />r�N O <br />111irrn a�¢ <br />ILA z o o <br />Z06 0 3 tyi <br />W ❑�❑ <br />z <br />z <br />z <br />z <br />N 8 <br />(Dru <br />w <br />U <br />Ow <br />U <br />0 <br />¢QD <br />see <br />(M <br />M <br />M <br />-J <br />E_ <br />° <br />z0 <br />00 <br />r. <br />d <br />z <br />g 'd <br />CIL <br />Q <br />7G E� <br />co <br />R � <br />�S <br />z <br />ro <br />� <br />2Cn <br />to Jw <br />7� <br />W <br />a <br />U <br />$� <br />aZ <br />LL <br />z <br />'NJ <br />M <br />O <br />•V <br />O <br />U) M <br />O <br />C14 <br />C) <br />O <br />0) <br />"' <br />Q N <br />cM <br />r <br />E <br />ca <br />M <br />T' <br />Z <br />A <br />E <br />2 <br />c <br />cg ¢ o <br />JOB <br />NO : 22-02351 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.