3
<br />d'
<br />0
<br />i
<br />4
<br />r
<br />N
<br />rn
<br />.9
<br />49
<br />C"
<br />N
<br />E
<br />E
<br />CL
<br />c�
<br />v
<br />c�
<br />i
<br />U
<br />N
<br />U
<br />I
<br />0
<br />U
<br />.S
<br />a>
<br />Cz
<br />N
<br />N
<br />N
<br />5i
<br />0
<br />a
<br />0
<br />N
<br />N
<br />0
<br />SIMPSON HGAM11
<br />W/
<br />(4)1/4"x1 1/2" SDS
<br />SCREWS
<br />TO BLOCKING & (i
<br />1/4 x2 3/4"
<br />TITEN TO CMU
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND
<br />FASTENERS. (MIN. FIRST 4 BAYS)
<br />SEE STRUCTURAL NOTES AND NAILING TOENAIL w/
<br />SCHEDULE FOR SHEATHING DETAIL-7 (2)16d NAILS—\
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING
<br />MAX. 9" AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />UNSUPPORTED,
<br />IF >9" SEE 10JS5 BACKNAIL w/ (2)16d NAILS �
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />MAX. 9" SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING
<br />UNSUPPORTED, AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />IF >9" SEE 10/S5
<br />BACKNAIL w/ (2) 16d NAILS
<br />SEE STRUCTURAL NOTES AND NAILING
<br />SCHEDULE FOR SHEATHING DETAIL
<br />45°t /
<br />45° t SEE STRUCTURAL
<br />NOTES AND NAILING
<br />2x4 CRO BRACE �A
<br />SCHEDULE FOR
<br />APPROX. 8" FROM SHEATHING DETAIL 2x4 KICKER 2x8 SYP#2 "L" BRACE TO
<br />EXTEND AT LEAST 90% OF
<br />RIDGE FASTENED AT "L" BRACE TO EXTEND 2x4 CROSS BRACE @ 8'-0" 0/C. WEB LENGTH & NOTCH AT '
<br />EACH JOINT W/ (3) 10d AT LEAST 90% OF WEB APPROX. 8" FROM BOTTOM CHORD (SEE TABLE)
<br />& (2)10d TOE NAILS @ LENGTH (SEE TABLE) RIDGE FASTENED AT
<br />EA. END @ 48" O.C. SIMPSON H2.5A w/ (10) 8d
<br />2x8 P.T. GABLE TRUSS EACH JOINT w/ (3)10d &
<br />SILL (2)1Od TOE NAILS @ EA. FROM LEDGER TO
<br />1/2" CDX PLYWOOD OR END BLOCKING
<br />7/16" OSB SHEATHING GYPSUM WALL BOARD
<br />ATTACHED W/ 10d GABLE TRUSS
<br />NAILS @ 6" O.C. EDGES 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST '
<br />AND 12" O.C. FIELD (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM [��1/2" CDX PLYWOOD OR 7/16"
<br />CORD ATTACHED W/ (2) 16d TOENAILS OSB SHEATHING ATTACHED
<br />1OdX3" @ 3" O/C w/ 10d NAILS @ 6" O.C.
<br />THROUGH CHORD 2"x4" LEDGER (MATCH BOTTOM CHORD EDGES AND 12" O.C. FIELD
<br />INTO 2"x6" P T PLATE SLOPE OF ADJACENT SCISSOR TRUSS)
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH) - ON FRAMING SHEET FOR SHEATHING
<br />AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />MAX. 9"
<br />UNSUPPORTED, BACKNAIL w/ (2)16d NAILS
<br />IF >9" SEE 10/S5 SEE STRUCTURAL NOTES AND
<br />AI NAILING SCHEDULE FOR SHEATHING
<br />DETAIL
<br />�- DOUBLE TOP PLATE 2"x4" CROSS BRACE
<br />2x4 CROSS BRACE APPROX. 8" APPROX. 8" FROM
<br />FROM RIDGE FASTENED AT RIDGE FASTENED AT
<br />EACH JOINT w/ (3) 1 Od & (2) 1 Od EACH JOINT w/ (3)
<br />TOE NAILS @ EA. END 10d & (2)10d TOE
<br />2x FRAME WALL (SEE WALL NAILS @ EA. END
<br />SECTION FOR SIZE & SPACING) 2x4 PANEL BLOCKING
<br />1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE
<br />OSB SHEATHING ATTACHED FIRST (4) ROWS OF
<br />W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA.
<br />AND 12" O.C. FIELD END TYP. TOP &
<br />• (2) 16d NAILS BOTTOM ATTACHED
<br />W/ (2)16d TOENAILS
<br />2 x6 P.T. SILL NOTCH "L" BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING
<br />2x4'7" ON TOP OF PANEL BLOCKING, WEEP SCREED 1 THE FIRST 4 ROWS OF TRUSSES
<br />FASTEN WITH 10dx3" @ 4" 0/C SPACED 1/2" x 8" "J" BOLT @ 48" 0 C () 2x4 "T" ON TOP OF PANEL
<br />(2)16d
<br />NAILS
<br />@ 48" O.C. INSTALLED PER MANUF. WEEP SCREED FROM EA. END TYP. TOP & BOTTOM BLOCKING, FASTEN WITH SIMPSON HGAIOKT w/ (4)1/4"x1 1/2" SDS SCREWS TO J
<br />"" " " MOISTURE BARRIER SIMPSON META12 wl (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS 10dx3" @ 4" 0/C TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C.
<br />1/2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - MOISTURE BARRIER
<br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS
<br />SIMPSON META12 w/ (7)
<br />NOTE: IF EMBEDDED 10dxl 1/2" NAILS AT EA. & (4) 1/4"X2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH
<br />STRAP MISSED VERTICAL SECTION TRUSS VERTICAL WEB (24" GABLE WEB SECTION-
<br />WEB, USE MSTAM36 w/ (7) O.C. MAX) w/ MIN. 4"
<br />2
<br />1Od NAILS & (4) 1/4"X2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK
<br />TITEN ON OUTSIDE S5 SCALE: N.T.S. S5
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING
<br />REFER TO DETAIL J N AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />ON SHEET S5 FOR M
<br />X-BRACING, AND TOP SEE STRUCTURAL
<br />CHORD BLOCKING N NOTES AND NAILING
<br />INFORMATION `°
<br />SCHEDULE FOR
<br />Ill. SHEATHING DETAIL BACKNAIL w/
<br />WOOD TRUSSES1/ (2)16d NAILS
<br />`O � � 2"x4" CROSS BRACE
<br />2x4 RAT RUN BRACING APPROX. 8" FROM
<br />RIDGE FASTENED AT
<br />AT 24" O.C. ON TOP OF EACH JOINT w/ (3)
<br />BOTT. CHORD FOR 4 10d & (2)10d TOE
<br />TRUSS SPANS 40�
<br />NAILS @ EA. END
<br />ATTACHED W/ 2 -16d
<br />AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF 2x4 PANEL BLOCKING
<br />OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS @ 48" O/C FOR THE (2)16d NAILS
<br />2X4 BLOCKING @ 24" FIRST (4) ROWS OF
<br />0/C w/ (2)16d (D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL TRUSSES FROM EA. '
<br />TOENAILS @ EA. END NOTES: END TYP. TOP &
<br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5112" LAG SCREWS OR EQUAL BOTTOM ATTACHED
<br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2)16d TOENAILS
<br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL
<br />F THE (SPACE AS SHOWN FOR 3-PLY)
<br />MAX. 9"
<br />UNSUPPORTED, 8d @ 6"0/C
<br />IF >9" SEE 1 O/S5 r-WOOD TRUSSES
<br />"L" BRACE TO EXTEND
<br />AT LEAST 90% OF WEB
<br />LENGTH (SEE TABLE)
<br />-GABLE TRUSS
<br />-1/2" CDX PLYWOOD OR 7/16"
<br />OSB SHEATHING ATTACHED
<br />W/ 1Od NAILS @ 6" O.C. SIMPSON HGAM1OKTA w/ (4)
<br />E ES AND 12" O.C. FIELD 1/4"x1 1/2" SDS SCREWS TO
<br />—JACK TRUSS BLOCKING & (4)1/4"x2 3/4"
<br />SEE PLAN FOR TITEN TO CMU
<br />.,CONNECTION
<br />0 LAST LAMINATION 2x4'T ON TOP OF PANEL ``
<br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, FASTEN WITH L 2x4 BLOCKING W/
<br />EXT. WALL CONN. @ 1Odx3" @ 4" O/C (2)12d TOENAILS
<br />NON -LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF I � ,
<br />D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) _�
<br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=r-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT—UP COLUMNS 8 SECTION g
<br />ADDITIONAL INFORMATION. SCALE: N.T.S. S5 SCALE: N.T.S. S5
<br />11NIMUM 2x
<br />'ROSS BRACING
<br />3EE PLAN FOR
<br />OCATIONS) TOENAIL t
<br />(2)16d NA
<br />(2)16d PER
<br />JOINT
<br />..,....... 2"x4" MIN. SEE M/S5
<br />CROSS BRACING DETAIL
<br />SCALE: N.T.S
<br />S5
<br />12
<br />6.9 MAX.
<br />S5
<br />J
<br />S5
<br />GABLE TRUSS
<br />12"
<br />SH SCHEDULE
<br />ATTACHMENT
<br />SYP BLK'G @ 16" O.C.
<br />I x 0.131"
<br />AILS EA. SIDE
<br />2x4 #2 SYP w/ 1 Od
<br />XO.131"@8"O.C.
<br />ALTERNATE NON —DROP
<br />GABLE END DETAIL 10
<br />SCALE: N.T.S. S5
<br />"L" BRACE W/ 10d @ 4" O.C.
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />S5
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SCALE: N.T.S.
<br />PRE-ENGINEERED
<br />WOOD TRUSSES
<br />OVERLAP TRUSS BRACING
<br />AT LEAST TWO TRUSS SPACES
<br />\-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING
<br />TRUSS BRACING OVERLAP DETAIL
<br />SCALE: N.T.S.
<br />6" OVERLAP
<br />M
<br />S5
<br />"L" BRACE W/ 10d @ 4" O/C
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />a
<br />MAX. 9"
<br />UNSUPPORTED,
<br />IF >9" SEE 10/S5
<br />"L" BRACE TO EXTEND
<br />AT LEAST 90% OF WEB
<br />LENGTH (SEE TABLE)
<br />-GABLE TRUSS
<br />-1/2" CDX PLYWOOD OR
<br />7/16" OSB SHEATHING
<br />ATTACHED w/ 1 Od NAILS
<br />@ 6" O.C. EDGES AND 12"
<br />O.C. FIELD
<br />•2x4 "T" ON TOP OF PANEL
<br />BLOCKING, FASTEN WITH
<br />1Odx3" @ 4" O/C
<br />2x4 BLOCKING 2x4'T' BLOCKING
<br />@ 48" O.C. 16d NAIL
<br />"L" BRACE
<br />ATTACHED W/
<br />1 Od NAILS @ 4"
<br />O.C. TYPICAL_ j
<br />GABLE TRUSS WEB
<br />DOUBLE "L" BRACING DETAIL 5
<br />SCALE: N.T.S. S5
<br />2x4'T' BLOCKING
<br />2x4 BLOCKING @
<br />48" O.C.
<br />"L" BRACE ATTACHED 16d NAIL
<br />W/ 10d NAILS @ 4" O.C�
<br />TYPICAL
<br />GABLE TRUSS WEB
<br />SINGLE "L" BRACING DETAIL 6
<br />SCALE: N.T.S. S5
<br />DIAPHRAGM
<br />BLOCKING @
<br />48" O/C GABLE TRUSS
<br />TRUSS VERTICAL
<br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE SIMPSON SP2 w/ (12)10d
<br />NAILS AT EACH STUD (2) 2"x8" "L" BRACE
<br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) FASTENED WITH (3)
<br />16d PER SIDE
<br />SECTION 3 SECTION 4 SCISSOR GABLE "T" BRACE
<br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 AS PER HIB 91 SCALE: N.T.S. S5
<br />20'-0" MAX 20'-0" MAX
<br />"X" BRACE SEE DET. J/S5 -t r CONTINUOUS BOTTO CHORD BRACING 2X4 MIN.
<br />2 x 4 BLOCKING w/ (2)10d
<br />TOE NAILS AT EACH END @
<br />24" O/C (TYP)
<br />•
<br />EXT. WALL CONN. NON - LOAD
<br />BEARING LOCATIO (UNEVEN CLG.) rE
<br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S5
<br />ADDITIONAL INFORMATION.
<br />"L" BRACING REQUIREMENTS
<br />STUD NO (1) 2"x4" (U.N.O.) 2"x6" (U.N.O.)
<br />SPACING "L" BRACE "L" BRACE "L" BRACE
<br />24" 010" - 3'-0" T-O" - 6'-0" 6'-0" & GREATER
<br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND
<br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING
<br />NOTE:
<br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES
<br />BRACE TO EXTEND FULL HEIGHT OF GABLE.
<br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C.
<br />3) SEE 6/S5 FOR MORE INFO.
<br />SIMPSON HGA10KT w/ (4)1/4"x1 1/2" SIDS
<br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS
<br />TO PLATES (TYP.)
<br />STUDS @ 16" O.C.
<br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0"
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />TRUSS
<br />SIMPSON SP2 w/ (12)
<br />10d NAILS AT EACH
<br />STUD
<br />END JACK
<br />1 V-0" MAX.
<br />Uj
<br />✓9c�
<br />Y CORNERJACK
<br />a_ Q
<br />tY
<br />tll
<br />z
<br />IY
<br />O
<br />HIP FRAMING REFERENCE PLAN
<br />0
<br />z
<br />w
<br />\-BRACING w/(3) 10dx 3" AT
<br />EACH CONN. @ 24" O/C
<br />—MOISTURE BARRIER
<br />BOND BEAM
<br />MASONRY WALL
<br />ARCHITECTURAL FINISH NOTE: STOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />Illl�ln� g
<br />II
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />W/ DROP CEILING BRACING DETAIL
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />N p
<br />0 � O
<br />cN.+ Q C) N
<br />N @ CID
<br />C� -C N
<br />R
<br />� O
<br />(f.
<br />Q O
<br />U
<br />w li CL C
<br />� to O O
<br />� r U
<br />a. E 0Ul
<br />` `i J • �.
<br />U 0
<br />•� -� P�o.
<br />aF 0� .
<br />''••.,F L.�
<br />01'� E S S I O IA 0
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal Is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />0 ti
<br />4 8 $g gR
<br />N Qf J lL
<br />0 :5 c'
<br /># LL a
<br />cz � i aL a
<br />Q � u- 0 Z 'Fo
<br />OSC
<br />0: f0 c0 it 0
<br />ILW
<br />a
<br />N M Z �g N O
<br />0 o cQi c3 3 ran
<br />Z �0❑
<br />w
<br />(n
<br />z
<br />z �
<br />a
<br />(V
<br />�+-ruj
<br />U
<br />0 w sleft
<br />Ln Ilk
<br />cd
<br />M y
<br />M
<br />J
<br />Eg z0
<br />Q O wK
<br />�_S s�o
<br />z Q4
<br />N _ o jz
<br />wx
<br />ro a
<br />z C Y Zz
<br />8 °
<br />U
<br />W =
<br />NJ
<br />e� J
<br />>(n
<br />O
<br />m
<br />i0
<br />T
<br />�1 «<'////JJJ)
<br />I— 4-0
<br />4 m
<br />O
<br />04
<br />0 '� o Lb
<br />CV Q N T
<br />t--
<br />N
<br />Z T N Z
<br />E O cc
<br />o E «? c
<br />0- ¢ o" �
<br />JOB NO: 22-02351
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH) - ON FRAMING SHEET FOR SHEATHING
<br />AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />MAX. 9"
<br />UNSUPPORTED, BACKNAIL w/ (2)16d NAILS
<br />IF >9" SEE 10/S5 SEE STRUCTURAL NOTES AND
<br />AI NAILING SCHEDULE FOR SHEATHING
<br />DETAIL
<br />�- DOUBLE TOP PLATE 2"x4" CROSS BRACE
<br />2x4 CROSS BRACE APPROX. 8" APPROX. 8" FROM
<br />FROM RIDGE FASTENED AT RIDGE FASTENED AT
<br />EACH JOINT w/ (3) 1 Od & (2) 1 Od EACH JOINT w/ (3)
<br />TOE NAILS @ EA. END 10d & (2)10d TOE
<br />2x FRAME WALL (SEE WALL NAILS @ EA. END
<br />SECTION FOR SIZE & SPACING) 2x4 PANEL BLOCKING
<br />1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE
<br />OSB SHEATHING ATTACHED FIRST (4) ROWS OF
<br />W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA.
<br />AND 12" O.C. FIELD END TYP. TOP &
<br />• (2) 16d NAILS BOTTOM ATTACHED
<br />W/ (2)16d TOENAILS
<br />2 x6 P.T. SILL NOTCH "L" BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING
<br />2x4'7" ON TOP OF PANEL BLOCKING, WEEP SCREED 1 THE FIRST 4 ROWS OF TRUSSES
<br />FASTEN WITH 10dx3" @ 4" 0/C SPACED 1/2" x 8" "J" BOLT @ 48" 0 C () 2x4 "T" ON TOP OF PANEL
<br />(2)16d
<br />NAILS
<br />@ 48" O.C. INSTALLED PER MANUF. WEEP SCREED FROM EA. END TYP. TOP & BOTTOM BLOCKING, FASTEN WITH SIMPSON HGAIOKT w/ (4)1/4"x1 1/2" SDS SCREWS TO J
<br />"" " " MOISTURE BARRIER SIMPSON META12 wl (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS 10dx3" @ 4" 0/C TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C.
<br />1/2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - MOISTURE BARRIER
<br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS
<br />SIMPSON META12 w/ (7)
<br />NOTE: IF EMBEDDED 10dxl 1/2" NAILS AT EA. & (4) 1/4"X2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH
<br />STRAP MISSED VERTICAL SECTION TRUSS VERTICAL WEB (24" GABLE WEB SECTION-
<br />WEB, USE MSTAM36 w/ (7) O.C. MAX) w/ MIN. 4"
<br />2
<br />1Od NAILS & (4) 1/4"X2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK
<br />TITEN ON OUTSIDE S5 SCALE: N.T.S. S5
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING
<br />REFER TO DETAIL J N AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />ON SHEET S5 FOR M
<br />X-BRACING, AND TOP SEE STRUCTURAL
<br />CHORD BLOCKING N NOTES AND NAILING
<br />INFORMATION `°
<br />SCHEDULE FOR
<br />Ill. SHEATHING DETAIL BACKNAIL w/
<br />WOOD TRUSSES1/ (2)16d NAILS
<br />`O � � 2"x4" CROSS BRACE
<br />2x4 RAT RUN BRACING APPROX. 8" FROM
<br />RIDGE FASTENED AT
<br />AT 24" O.C. ON TOP OF EACH JOINT w/ (3)
<br />BOTT. CHORD FOR 4 10d & (2)10d TOE
<br />TRUSS SPANS 40�
<br />NAILS @ EA. END
<br />ATTACHED W/ 2 -16d
<br />AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF 2x4 PANEL BLOCKING
<br />OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS @ 48" O/C FOR THE (2)16d NAILS
<br />2X4 BLOCKING @ 24" FIRST (4) ROWS OF
<br />0/C w/ (2)16d (D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL TRUSSES FROM EA. '
<br />TOENAILS @ EA. END NOTES: END TYP. TOP &
<br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5112" LAG SCREWS OR EQUAL BOTTOM ATTACHED
<br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2)16d TOENAILS
<br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL
<br />F THE (SPACE AS SHOWN FOR 3-PLY)
<br />MAX. 9"
<br />UNSUPPORTED, 8d @ 6"0/C
<br />IF >9" SEE 1 O/S5 r-WOOD TRUSSES
<br />"L" BRACE TO EXTEND
<br />AT LEAST 90% OF WEB
<br />LENGTH (SEE TABLE)
<br />-GABLE TRUSS
<br />-1/2" CDX PLYWOOD OR 7/16"
<br />OSB SHEATHING ATTACHED
<br />W/ 1Od NAILS @ 6" O.C. SIMPSON HGAM1OKTA w/ (4)
<br />E ES AND 12" O.C. FIELD 1/4"x1 1/2" SDS SCREWS TO
<br />—JACK TRUSS BLOCKING & (4)1/4"x2 3/4"
<br />SEE PLAN FOR TITEN TO CMU
<br />.,CONNECTION
<br />0 LAST LAMINATION 2x4'T ON TOP OF PANEL ``
<br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, FASTEN WITH L 2x4 BLOCKING W/
<br />EXT. WALL CONN. @ 1Odx3" @ 4" O/C (2)12d TOENAILS
<br />NON -LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF I � ,
<br />D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) _�
<br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=r-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT—UP COLUMNS 8 SECTION g
<br />ADDITIONAL INFORMATION. SCALE: N.T.S. S5 SCALE: N.T.S. S5
<br />11NIMUM 2x
<br />'ROSS BRACING
<br />3EE PLAN FOR
<br />OCATIONS) TOENAIL t
<br />(2)16d NA
<br />(2)16d PER
<br />JOINT
<br />..,....... 2"x4" MIN. SEE M/S5
<br />CROSS BRACING DETAIL
<br />SCALE: N.T.S
<br />S5
<br />12
<br />6.9 MAX.
<br />S5
<br />J
<br />S5
<br />GABLE TRUSS
<br />12"
<br />SH SCHEDULE
<br />ATTACHMENT
<br />SYP BLK'G @ 16" O.C.
<br />I x 0.131"
<br />AILS EA. SIDE
<br />2x4 #2 SYP w/ 1 Od
<br />XO.131"@8"O.C.
<br />ALTERNATE NON —DROP
<br />GABLE END DETAIL 10
<br />SCALE: N.T.S. S5
<br />"L" BRACE W/ 10d @ 4" O.C.
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />S5
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SCALE: N.T.S.
<br />PRE-ENGINEERED
<br />WOOD TRUSSES
<br />OVERLAP TRUSS BRACING
<br />AT LEAST TWO TRUSS SPACES
<br />\-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING
<br />TRUSS BRACING OVERLAP DETAIL
<br />SCALE: N.T.S.
<br />6" OVERLAP
<br />M
<br />S5
<br />"L" BRACE W/ 10d @ 4" O/C
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />a
<br />MAX. 9"
<br />UNSUPPORTED,
<br />IF >9" SEE 10/S5
<br />"L" BRACE TO EXTEND
<br />AT LEAST 90% OF WEB
<br />LENGTH (SEE TABLE)
<br />-GABLE TRUSS
<br />-1/2" CDX PLYWOOD OR
<br />7/16" OSB SHEATHING
<br />ATTACHED w/ 1 Od NAILS
<br />@ 6" O.C. EDGES AND 12"
<br />O.C. FIELD
<br />•2x4 "T" ON TOP OF PANEL
<br />BLOCKING, FASTEN WITH
<br />1Odx3" @ 4" O/C
<br />2x4 BLOCKING 2x4'T' BLOCKING
<br />@ 48" O.C. 16d NAIL
<br />"L" BRACE
<br />ATTACHED W/
<br />1 Od NAILS @ 4"
<br />O.C. TYPICAL_ j
<br />GABLE TRUSS WEB
<br />DOUBLE "L" BRACING DETAIL 5
<br />SCALE: N.T.S. S5
<br />2x4'T' BLOCKING
<br />2x4 BLOCKING @
<br />48" O.C.
<br />"L" BRACE ATTACHED 16d NAIL
<br />W/ 10d NAILS @ 4" O.C�
<br />TYPICAL
<br />GABLE TRUSS WEB
<br />SINGLE "L" BRACING DETAIL 6
<br />SCALE: N.T.S. S5
<br />DIAPHRAGM
<br />BLOCKING @
<br />48" O/C GABLE TRUSS
<br />TRUSS VERTICAL
<br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE SIMPSON SP2 w/ (12)10d
<br />NAILS AT EACH STUD (2) 2"x8" "L" BRACE
<br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) FASTENED WITH (3)
<br />16d PER SIDE
<br />SECTION 3 SECTION 4 SCISSOR GABLE "T" BRACE
<br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 AS PER HIB 91 SCALE: N.T.S. S5
<br />20'-0" MAX 20'-0" MAX
<br />"X" BRACE SEE DET. J/S5 -t r CONTINUOUS BOTTO CHORD BRACING 2X4 MIN.
<br />2 x 4 BLOCKING w/ (2)10d
<br />TOE NAILS AT EACH END @
<br />24" O/C (TYP)
<br />•
<br />EXT. WALL CONN. NON - LOAD
<br />BEARING LOCATIO (UNEVEN CLG.) rE
<br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S5
<br />ADDITIONAL INFORMATION.
<br />"L" BRACING REQUIREMENTS
<br />STUD NO (1) 2"x4" (U.N.O.) 2"x6" (U.N.O.)
<br />SPACING "L" BRACE "L" BRACE "L" BRACE
<br />24" 010" - 3'-0" T-O" - 6'-0" 6'-0" & GREATER
<br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND
<br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING
<br />NOTE:
<br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES
<br />BRACE TO EXTEND FULL HEIGHT OF GABLE.
<br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C.
<br />3) SEE 6/S5 FOR MORE INFO.
<br />SIMPSON HGA10KT w/ (4)1/4"x1 1/2" SIDS
<br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS
<br />TO PLATES (TYP.)
<br />STUDS @ 16" O.C.
<br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0"
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />TRUSS
<br />SIMPSON SP2 w/ (12)
<br />10d NAILS AT EACH
<br />STUD
<br />END JACK
<br />1 V-0" MAX.
<br />Uj
<br />✓9c�
<br />Y CORNERJACK
<br />a_ Q
<br />tY
<br />tll
<br />z
<br />IY
<br />O
<br />HIP FRAMING REFERENCE PLAN
<br />0
<br />z
<br />w
<br />\-BRACING w/(3) 10dx 3" AT
<br />EACH CONN. @ 24" O/C
<br />—MOISTURE BARRIER
<br />BOND BEAM
<br />MASONRY WALL
<br />ARCHITECTURAL FINISH NOTE: STOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />Illl�ln� g
<br />II
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />W/ DROP CEILING BRACING DETAIL
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />N p
<br />0 � O
<br />cN.+ Q C) N
<br />N @ CID
<br />C� -C N
<br />R
<br />� O
<br />(f.
<br />Q O
<br />U
<br />w li CL C
<br />� to O O
<br />� r U
<br />a. E 0Ul
<br />` `i J • �.
<br />U 0
<br />•� -� P�o.
<br />aF 0� .
<br />''••.,F L.�
<br />01'� E S S I O IA 0
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal Is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />0 ti
<br />4 8 $g gR
<br />N Qf J lL
<br />0 :5 c'
<br /># LL a
<br />cz � i aL a
<br />Q � u- 0 Z 'Fo
<br />OSC
<br />0: f0 c0 it 0
<br />ILW
<br />a
<br />N M Z �g N O
<br />0 o cQi c3 3 ran
<br />Z �0❑
<br />w
<br />(n
<br />z
<br />z �
<br />a
<br />(V
<br />�+-ruj
<br />U
<br />0 w sleft
<br />Ln Ilk
<br />cd
<br />M y
<br />M
<br />J
<br />Eg z0
<br />Q O wK
<br />�_S s�o
<br />z Q4
<br />N _ o jz
<br />wx
<br />ro a
<br />z C Y Zz
<br />8 °
<br />U
<br />W =
<br />NJ
<br />e� J
<br />>(n
<br />O
<br />m
<br />i0
<br />T
<br />�1 «<'////JJJ)
<br />I— 4-0
<br />4 m
<br />O
<br />04
<br />0 '� o Lb
<br />CV Q N T
<br />t--
<br />N
<br />Z T N Z
<br />E O cc
<br />o E «? c
<br />0- ¢ o" �
<br />JOB NO: 22-02351
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />2 x6 P.T. SILL NOTCH "L" BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING
<br />2x4'7" ON TOP OF PANEL BLOCKING, WEEP SCREED 1 THE FIRST 4 ROWS OF TRUSSES
<br />FASTEN WITH 10dx3" @ 4" 0/C SPACED 1/2" x 8" "J" BOLT @ 48" 0 C () 2x4 "T" ON TOP OF PANEL
<br />(2)16d
<br />NAILS
<br />@ 48" O.C. INSTALLED PER MANUF. WEEP SCREED FROM EA. END TYP. TOP & BOTTOM BLOCKING, FASTEN WITH SIMPSON HGAIOKT w/ (4)1/4"x1 1/2" SDS SCREWS TO J
<br />"" " " MOISTURE BARRIER SIMPSON META12 wl (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS 10dx3" @ 4" 0/C TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C.
<br />1/2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - MOISTURE BARRIER
<br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS
<br />SIMPSON META12 w/ (7)
<br />NOTE: IF EMBEDDED 10dxl 1/2" NAILS AT EA. & (4) 1/4"X2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH
<br />STRAP MISSED VERTICAL SECTION TRUSS VERTICAL WEB (24" GABLE WEB SECTION-
<br />WEB, USE MSTAM36 w/ (7) O.C. MAX) w/ MIN. 4"
<br />2
<br />1Od NAILS & (4) 1/4"X2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK
<br />TITEN ON OUTSIDE S5 SCALE: N.T.S. S5
<br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END.
<br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING
<br />REFER TO DETAIL J N AND FASTENERS. (MIN. FIRST 4 BAYS)
<br />ON SHEET S5 FOR M
<br />X-BRACING, AND TOP SEE STRUCTURAL
<br />CHORD BLOCKING N NOTES AND NAILING
<br />INFORMATION `°
<br />SCHEDULE FOR
<br />Ill. SHEATHING DETAIL BACKNAIL w/
<br />WOOD TRUSSES1/ (2)16d NAILS
<br />`O � � 2"x4" CROSS BRACE
<br />2x4 RAT RUN BRACING APPROX. 8" FROM
<br />RIDGE FASTENED AT
<br />AT 24" O.C. ON TOP OF EACH JOINT w/ (3)
<br />BOTT. CHORD FOR 4 10d & (2)10d TOE
<br />TRUSS SPANS 40�
<br />NAILS @ EA. END
<br />ATTACHED W/ 2 -16d
<br />AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF 2x4 PANEL BLOCKING
<br />OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS @ 48" O/C FOR THE (2)16d NAILS
<br />2X4 BLOCKING @ 24" FIRST (4) ROWS OF
<br />0/C w/ (2)16d (D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL TRUSSES FROM EA. '
<br />TOENAILS @ EA. END NOTES: END TYP. TOP &
<br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5112" LAG SCREWS OR EQUAL BOTTOM ATTACHED
<br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2)16d TOENAILS
<br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL
<br />F THE (SPACE AS SHOWN FOR 3-PLY)
<br />MAX. 9"
<br />UNSUPPORTED, 8d @ 6"0/C
<br />IF >9" SEE 1 O/S5 r-WOOD TRUSSES
<br />"L" BRACE TO EXTEND
<br />AT LEAST 90% OF WEB
<br />LENGTH (SEE TABLE)
<br />-GABLE TRUSS
<br />-1/2" CDX PLYWOOD OR 7/16"
<br />OSB SHEATHING ATTACHED
<br />W/ 1Od NAILS @ 6" O.C. SIMPSON HGAM1OKTA w/ (4)
<br />E ES AND 12" O.C. FIELD 1/4"x1 1/2" SDS SCREWS TO
<br />—JACK TRUSS BLOCKING & (4)1/4"x2 3/4"
<br />SEE PLAN FOR TITEN TO CMU
<br />.,CONNECTION
<br />0 LAST LAMINATION 2x4'T ON TOP OF PANEL ``
<br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, FASTEN WITH L 2x4 BLOCKING W/
<br />EXT. WALL CONN. @ 1Odx3" @ 4" O/C (2)12d TOENAILS
<br />NON -LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF I � ,
<br />D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) _�
<br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=r-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT—UP COLUMNS 8 SECTION g
<br />ADDITIONAL INFORMATION. SCALE: N.T.S. S5 SCALE: N.T.S. S5
<br />11NIMUM 2x
<br />'ROSS BRACING
<br />3EE PLAN FOR
<br />OCATIONS) TOENAIL t
<br />(2)16d NA
<br />(2)16d PER
<br />JOINT
<br />..,....... 2"x4" MIN. SEE M/S5
<br />CROSS BRACING DETAIL
<br />SCALE: N.T.S
<br />S5
<br />12
<br />6.9 MAX.
<br />S5
<br />J
<br />S5
<br />GABLE TRUSS
<br />12"
<br />SH SCHEDULE
<br />ATTACHMENT
<br />SYP BLK'G @ 16" O.C.
<br />I x 0.131"
<br />AILS EA. SIDE
<br />2x4 #2 SYP w/ 1 Od
<br />XO.131"@8"O.C.
<br />ALTERNATE NON —DROP
<br />GABLE END DETAIL 10
<br />SCALE: N.T.S. S5
<br />"L" BRACE W/ 10d @ 4" O.C.
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />S5
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SCALE: N.T.S.
<br />PRE-ENGINEERED
<br />WOOD TRUSSES
<br />OVERLAP TRUSS BRACING
<br />AT LEAST TWO TRUSS SPACES
<br />\-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING
<br />TRUSS BRACING OVERLAP DETAIL
<br />SCALE: N.T.S.
<br />6" OVERLAP
<br />M
<br />S5
<br />"L" BRACE W/ 10d @ 4" O/C
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />a
<br />MAX. 9"
<br />UNSUPPORTED,
<br />IF >9" SEE 10/S5
<br />"L" BRACE TO EXTEND
<br />AT LEAST 90% OF WEB
<br />LENGTH (SEE TABLE)
<br />-GABLE TRUSS
<br />-1/2" CDX PLYWOOD OR
<br />7/16" OSB SHEATHING
<br />ATTACHED w/ 1 Od NAILS
<br />@ 6" O.C. EDGES AND 12"
<br />O.C. FIELD
<br />•2x4 "T" ON TOP OF PANEL
<br />BLOCKING, FASTEN WITH
<br />1Odx3" @ 4" O/C
<br />2x4 BLOCKING 2x4'T' BLOCKING
<br />@ 48" O.C. 16d NAIL
<br />"L" BRACE
<br />ATTACHED W/
<br />1 Od NAILS @ 4"
<br />O.C. TYPICAL_ j
<br />GABLE TRUSS WEB
<br />DOUBLE "L" BRACING DETAIL 5
<br />SCALE: N.T.S. S5
<br />2x4'T' BLOCKING
<br />2x4 BLOCKING @
<br />48" O.C.
<br />"L" BRACE ATTACHED 16d NAIL
<br />W/ 10d NAILS @ 4" O.C�
<br />TYPICAL
<br />GABLE TRUSS WEB
<br />SINGLE "L" BRACING DETAIL 6
<br />SCALE: N.T.S. S5
<br />DIAPHRAGM
<br />BLOCKING @
<br />48" O/C GABLE TRUSS
<br />TRUSS VERTICAL
<br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE SIMPSON SP2 w/ (12)10d
<br />NAILS AT EACH STUD (2) 2"x8" "L" BRACE
<br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) FASTENED WITH (3)
<br />16d PER SIDE
<br />SECTION 3 SECTION 4 SCISSOR GABLE "T" BRACE
<br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 AS PER HIB 91 SCALE: N.T.S. S5
<br />20'-0" MAX 20'-0" MAX
<br />"X" BRACE SEE DET. J/S5 -t r CONTINUOUS BOTTO CHORD BRACING 2X4 MIN.
<br />2 x 4 BLOCKING w/ (2)10d
<br />TOE NAILS AT EACH END @
<br />24" O/C (TYP)
<br />•
<br />EXT. WALL CONN. NON - LOAD
<br />BEARING LOCATIO (UNEVEN CLG.) rE
<br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S5
<br />ADDITIONAL INFORMATION.
<br />"L" BRACING REQUIREMENTS
<br />STUD NO (1) 2"x4" (U.N.O.) 2"x6" (U.N.O.)
<br />SPACING "L" BRACE "L" BRACE "L" BRACE
<br />24" 010" - 3'-0" T-O" - 6'-0" 6'-0" & GREATER
<br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND
<br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING
<br />NOTE:
<br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES
<br />BRACE TO EXTEND FULL HEIGHT OF GABLE.
<br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C.
<br />3) SEE 6/S5 FOR MORE INFO.
<br />SIMPSON HGA10KT w/ (4)1/4"x1 1/2" SIDS
<br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS
<br />TO PLATES (TYP.)
<br />STUDS @ 16" O.C.
<br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0"
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />TRUSS
<br />SIMPSON SP2 w/ (12)
<br />10d NAILS AT EACH
<br />STUD
<br />END JACK
<br />1 V-0" MAX.
<br />Uj
<br />✓9c�
<br />Y CORNERJACK
<br />a_ Q
<br />tY
<br />tll
<br />z
<br />IY
<br />O
<br />HIP FRAMING REFERENCE PLAN
<br />0
<br />z
<br />w
<br />\-BRACING w/(3) 10dx 3" AT
<br />EACH CONN. @ 24" O/C
<br />—MOISTURE BARRIER
<br />BOND BEAM
<br />MASONRY WALL
<br />ARCHITECTURAL FINISH NOTE: STOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />Illl�ln� g
<br />II
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />W/ DROP CEILING BRACING DETAIL
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />N p
<br />0 � O
<br />cN.+ Q C) N
<br />N @ CID
<br />C� -C N
<br />R
<br />� O
<br />(f.
<br />Q O
<br />U
<br />w li CL C
<br />� to O O
<br />� r U
<br />a. E 0Ul
<br />` `i J • �.
<br />U 0
<br />•� -� P�o.
<br />aF 0� .
<br />''••.,F L.�
<br />01'� E S S I O IA 0
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal Is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />0 ti
<br />4 8 $g gR
<br />N Qf J lL
<br />0 :5 c'
<br /># LL a
<br />cz � i aL a
<br />Q � u- 0 Z 'Fo
<br />OSC
<br />0: f0 c0 it 0
<br />ILW
<br />a
<br />N M Z �g N O
<br />0 o cQi c3 3 ran
<br />Z �0❑
<br />w
<br />(n
<br />z
<br />z �
<br />a
<br />(V
<br />�+-ruj
<br />U
<br />0 w sleft
<br />Ln Ilk
<br />cd
<br />M y
<br />M
<br />J
<br />Eg z0
<br />Q O wK
<br />�_S s�o
<br />z Q4
<br />N _ o jz
<br />wx
<br />ro a
<br />z C Y Zz
<br />8 °
<br />U
<br />W =
<br />NJ
<br />e� J
<br />>(n
<br />O
<br />m
<br />i0
<br />T
<br />�1 «<'////JJJ)
<br />I— 4-0
<br />4 m
<br />O
<br />04
<br />0 '� o Lb
<br />CV Q N T
<br />t--
<br />N
<br />Z T N Z
<br />E O cc
<br />o E «? c
<br />0- ¢ o" �
<br />JOB NO: 22-02351
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />11NIMUM 2x
<br />'ROSS BRACING
<br />3EE PLAN FOR
<br />OCATIONS) TOENAIL t
<br />(2)16d NA
<br />(2)16d PER
<br />JOINT
<br />..,....... 2"x4" MIN. SEE M/S5
<br />CROSS BRACING DETAIL
<br />SCALE: N.T.S
<br />S5
<br />12
<br />6.9 MAX.
<br />S5
<br />J
<br />S5
<br />GABLE TRUSS
<br />12"
<br />SH SCHEDULE
<br />ATTACHMENT
<br />SYP BLK'G @ 16" O.C.
<br />I x 0.131"
<br />AILS EA. SIDE
<br />2x4 #2 SYP w/ 1 Od
<br />XO.131"@8"O.C.
<br />ALTERNATE NON —DROP
<br />GABLE END DETAIL 10
<br />SCALE: N.T.S. S5
<br />"L" BRACE W/ 10d @ 4" O.C.
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />S5
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />SCALE: N.T.S.
<br />PRE-ENGINEERED
<br />WOOD TRUSSES
<br />OVERLAP TRUSS BRACING
<br />AT LEAST TWO TRUSS SPACES
<br />\-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING
<br />TRUSS BRACING OVERLAP DETAIL
<br />SCALE: N.T.S.
<br />6" OVERLAP
<br />M
<br />S5
<br />"L" BRACE W/ 10d @ 4" O/C
<br />(SEE SCHEDULE FOR SIZE
<br />AND LOCATION)
<br />a
<br />MAX. 9"
<br />UNSUPPORTED,
<br />IF >9" SEE 10/S5
<br />"L" BRACE TO EXTEND
<br />AT LEAST 90% OF WEB
<br />LENGTH (SEE TABLE)
<br />-GABLE TRUSS
<br />-1/2" CDX PLYWOOD OR
<br />7/16" OSB SHEATHING
<br />ATTACHED w/ 1 Od NAILS
<br />@ 6" O.C. EDGES AND 12"
<br />O.C. FIELD
<br />•2x4 "T" ON TOP OF PANEL
<br />BLOCKING, FASTEN WITH
<br />1Odx3" @ 4" O/C
<br />2x4 BLOCKING 2x4'T' BLOCKING
<br />@ 48" O.C. 16d NAIL
<br />"L" BRACE
<br />ATTACHED W/
<br />1 Od NAILS @ 4"
<br />O.C. TYPICAL_ j
<br />GABLE TRUSS WEB
<br />DOUBLE "L" BRACING DETAIL 5
<br />SCALE: N.T.S. S5
<br />2x4'T' BLOCKING
<br />2x4 BLOCKING @
<br />48" O.C.
<br />"L" BRACE ATTACHED 16d NAIL
<br />W/ 10d NAILS @ 4" O.C�
<br />TYPICAL
<br />GABLE TRUSS WEB
<br />SINGLE "L" BRACING DETAIL 6
<br />SCALE: N.T.S. S5
<br />DIAPHRAGM
<br />BLOCKING @
<br />48" O/C GABLE TRUSS
<br />TRUSS VERTICAL
<br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE SIMPSON SP2 w/ (12)10d
<br />NAILS AT EACH STUD (2) 2"x8" "L" BRACE
<br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) FASTENED WITH (3)
<br />16d PER SIDE
<br />SECTION 3 SECTION 4 SCISSOR GABLE "T" BRACE
<br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 AS PER HIB 91 SCALE: N.T.S. S5
<br />20'-0" MAX 20'-0" MAX
<br />"X" BRACE SEE DET. J/S5 -t r CONTINUOUS BOTTO CHORD BRACING 2X4 MIN.
<br />2 x 4 BLOCKING w/ (2)10d
<br />TOE NAILS AT EACH END @
<br />24" O/C (TYP)
<br />•
<br />EXT. WALL CONN. NON - LOAD
<br />BEARING LOCATIO (UNEVEN CLG.) rE
<br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S5
<br />ADDITIONAL INFORMATION.
<br />"L" BRACING REQUIREMENTS
<br />STUD NO (1) 2"x4" (U.N.O.) 2"x6" (U.N.O.)
<br />SPACING "L" BRACE "L" BRACE "L" BRACE
<br />24" 010" - 3'-0" T-O" - 6'-0" 6'-0" & GREATER
<br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND
<br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING
<br />NOTE:
<br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES
<br />BRACE TO EXTEND FULL HEIGHT OF GABLE.
<br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C.
<br />3) SEE 6/S5 FOR MORE INFO.
<br />SIMPSON HGA10KT w/ (4)1/4"x1 1/2" SIDS
<br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS
<br />TO PLATES (TYP.)
<br />STUDS @ 16" O.C.
<br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0"
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />TRUSS
<br />SIMPSON SP2 w/ (12)
<br />10d NAILS AT EACH
<br />STUD
<br />END JACK
<br />1 V-0" MAX.
<br />Uj
<br />✓9c�
<br />Y CORNERJACK
<br />a_ Q
<br />tY
<br />tll
<br />z
<br />IY
<br />O
<br />HIP FRAMING REFERENCE PLAN
<br />0
<br />z
<br />w
<br />\-BRACING w/(3) 10dx 3" AT
<br />EACH CONN. @ 24" O/C
<br />—MOISTURE BARRIER
<br />BOND BEAM
<br />MASONRY WALL
<br />ARCHITECTURAL FINISH NOTE: STOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />Illl�ln� g
<br />II
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />W/ DROP CEILING BRACING DETAIL
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />N p
<br />0 � O
<br />cN.+ Q C) N
<br />N @ CID
<br />C� -C N
<br />R
<br />� O
<br />(f.
<br />Q O
<br />U
<br />w li CL C
<br />� to O O
<br />� r U
<br />a. E 0Ul
<br />` `i J • �.
<br />U 0
<br />•� -� P�o.
<br />aF 0� .
<br />''••.,F L.�
<br />01'� E S S I O IA 0
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal Is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />0 ti
<br />4 8 $g gR
<br />N Qf J lL
<br />0 :5 c'
<br /># LL a
<br />cz � i aL a
<br />Q � u- 0 Z 'Fo
<br />OSC
<br />0: f0 c0 it 0
<br />ILW
<br />a
<br />N M Z �g N O
<br />0 o cQi c3 3 ran
<br />Z �0❑
<br />w
<br />(n
<br />z
<br />z �
<br />a
<br />(V
<br />�+-ruj
<br />U
<br />0 w sleft
<br />Ln Ilk
<br />cd
<br />M y
<br />M
<br />J
<br />Eg z0
<br />Q O wK
<br />�_S s�o
<br />z Q4
<br />N _ o jz
<br />wx
<br />ro a
<br />z C Y Zz
<br />8 °
<br />U
<br />W =
<br />NJ
<br />e� J
<br />>(n
<br />O
<br />m
<br />i0
<br />T
<br />�1 «<'////JJJ)
<br />I— 4-0
<br />4 m
<br />O
<br />04
<br />0 '� o Lb
<br />CV Q N T
<br />t--
<br />N
<br />Z T N Z
<br />E O cc
<br />o E «? c
<br />0- ¢ o" �
<br />JOB NO: 22-02351
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />NOTE:
<br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES
<br />BRACE TO EXTEND FULL HEIGHT OF GABLE.
<br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C.
<br />3) SEE 6/S5 FOR MORE INFO.
<br />SIMPSON HGA10KT w/ (4)1/4"x1 1/2" SIDS
<br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS
<br />TO PLATES (TYP.)
<br />STUDS @ 16" O.C.
<br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0"
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />TRUSS
<br />SIMPSON SP2 w/ (12)
<br />10d NAILS AT EACH
<br />STUD
<br />END JACK
<br />1 V-0" MAX.
<br />Uj
<br />✓9c�
<br />Y CORNERJACK
<br />a_ Q
<br />tY
<br />tll
<br />z
<br />IY
<br />O
<br />HIP FRAMING REFERENCE PLAN
<br />0
<br />z
<br />w
<br />\-BRACING w/(3) 10dx 3" AT
<br />EACH CONN. @ 24" O/C
<br />—MOISTURE BARRIER
<br />BOND BEAM
<br />MASONRY WALL
<br />ARCHITECTURAL FINISH NOTE: STOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />Illl�ln� g
<br />II
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />W/ DROP CEILING BRACING DETAIL
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />N p
<br />0 � O
<br />cN.+ Q C) N
<br />N @ CID
<br />C� -C N
<br />R
<br />� O
<br />(f.
<br />Q O
<br />U
<br />w li CL C
<br />� to O O
<br />� r U
<br />a. E 0Ul
<br />` `i J • �.
<br />U 0
<br />•� -� P�o.
<br />aF 0� .
<br />''••.,F L.�
<br />01'� E S S I O IA 0
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal Is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />0 ti
<br />4 8 $g gR
<br />N Qf J lL
<br />0 :5 c'
<br /># LL a
<br />cz � i aL a
<br />Q � u- 0 Z 'Fo
<br />OSC
<br />0: f0 c0 it 0
<br />ILW
<br />a
<br />N M Z �g N O
<br />0 o cQi c3 3 ran
<br />Z �0❑
<br />w
<br />(n
<br />z
<br />z �
<br />a
<br />(V
<br />�+-ruj
<br />U
<br />0 w sleft
<br />Ln Ilk
<br />cd
<br />M y
<br />M
<br />J
<br />Eg z0
<br />Q O wK
<br />�_S s�o
<br />z Q4
<br />N _ o jz
<br />wx
<br />ro a
<br />z C Y Zz
<br />8 °
<br />U
<br />W =
<br />NJ
<br />e� J
<br />>(n
<br />O
<br />m
<br />i0
<br />T
<br />�1 «<'////JJJ)
<br />I— 4-0
<br />4 m
<br />O
<br />04
<br />0 '� o Lb
<br />CV Q N T
<br />t--
<br />N
<br />Z T N Z
<br />E O cc
<br />o E «? c
<br />0- ¢ o" �
<br />JOB NO: 22-02351
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />HIP FRAMING REFERENCE PLAN
<br />0
<br />z
<br />w
<br />\-BRACING w/(3) 10dx 3" AT
<br />EACH CONN. @ 24" O/C
<br />—MOISTURE BARRIER
<br />BOND BEAM
<br />MASONRY WALL
<br />ARCHITECTURAL FINISH NOTE: STOP CHORD 2X4 #2 SYP BRACING
<br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING @ 16" O.C. MAX. FOR FIRST (4)
<br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS
<br />THAT MY BE REQUIRED ZBOTTOM CHORD GABLE END BRACING
<br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS
<br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
<br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN
<br />Illl�ln� g
<br />II
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />W/ DROP CEILING BRACING DETAIL
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />N p
<br />0 � O
<br />cN.+ Q C) N
<br />N @ CID
<br />C� -C N
<br />R
<br />� O
<br />(f.
<br />Q O
<br />U
<br />w li CL C
<br />� to O O
<br />� r U
<br />a. E 0Ul
<br />` `i J • �.
<br />U 0
<br />•� -� P�o.
<br />aF 0� .
<br />''••.,F L.�
<br />01'� E S S I O IA 0
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal Is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />0 ti
<br />4 8 $g gR
<br />N Qf J lL
<br />0 :5 c'
<br /># LL a
<br />cz � i aL a
<br />Q � u- 0 Z 'Fo
<br />OSC
<br />0: f0 c0 it 0
<br />ILW
<br />a
<br />N M Z �g N O
<br />0 o cQi c3 3 ran
<br />Z �0❑
<br />w
<br />(n
<br />z
<br />z �
<br />a
<br />(V
<br />�+-ruj
<br />U
<br />0 w sleft
<br />Ln Ilk
<br />cd
<br />M y
<br />M
<br />J
<br />Eg z0
<br />Q O wK
<br />�_S s�o
<br />z Q4
<br />N _ o jz
<br />wx
<br />ro a
<br />z C Y Zz
<br />8 °
<br />U
<br />W =
<br />NJ
<br />e� J
<br />>(n
<br />O
<br />m
<br />i0
<br />T
<br />�1 «<'////JJJ)
<br />I— 4-0
<br />4 m
<br />O
<br />04
<br />0 '� o Lb
<br />CV Q N T
<br />t--
<br />N
<br />Z T N Z
<br />E O cc
<br />o E «? c
<br />0- ¢ o" �
<br />JOB NO: 22-02351
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />AS PER BCSI
<br />SCISSOR TRUSS
<br />SCISSOR TRUSS
<br />SCALE: N.T.S.
<br />2X4 BRACING @ 48" O.C. CONTINUOUS TO
<br />FIXED LOCATION ATTACHED W/ (2)10d AT
<br />EA. TRUSS (NOTE: BRACING MAY BE
<br />PLACED ON EITHER TOP OR BOTTOM OF
<br />THE BOTTOM CORD)
<br />COSMETIC DROP CEILING FRAMING
<br />W/ DROP CEILING BRACING DETAIL
<br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS
<br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION
<br />WOOD FRAMED GABLE END BRACING DETAIL
<br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S.
<br />FOR WIND SPEED SPECIFICATION
<br />N p
<br />0 � O
<br />cN.+ Q C) N
<br />N @ CID
<br />C� -C N
<br />R
<br />� O
<br />(f.
<br />Q O
<br />U
<br />w li CL C
<br />� to O O
<br />� r U
<br />a. E 0Ul
<br />` `i J • �.
<br />U 0
<br />•� -� P�o.
<br />aF 0� .
<br />''••.,F L.�
<br />01'� E S S I O IA 0
<br />To the best of the Engineers knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineers signature and seal Is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />0 ti
<br />4 8 $g gR
<br />N Qf J lL
<br />0 :5 c'
<br /># LL a
<br />cz � i aL a
<br />Q � u- 0 Z 'Fo
<br />OSC
<br />0: f0 c0 it 0
<br />ILW
<br />a
<br />N M Z �g N O
<br />0 o cQi c3 3 ran
<br />Z �0❑
<br />w
<br />(n
<br />z
<br />z �
<br />a
<br />(V
<br />�+-ruj
<br />U
<br />0 w sleft
<br />Ln Ilk
<br />cd
<br />M y
<br />M
<br />J
<br />Eg z0
<br />Q O wK
<br />�_S s�o
<br />z Q4
<br />N _ o jz
<br />wx
<br />ro a
<br />z C Y Zz
<br />8 °
<br />U
<br />W =
<br />NJ
<br />e� J
<br />>(n
<br />O
<br />m
<br />i0
<br />T
<br />�1 «<'////JJJ)
<br />I— 4-0
<br />4 m
<br />O
<br />04
<br />0 '� o Lb
<br />CV Q N T
<br />t--
<br />N
<br />Z T N Z
<br />E O cc
<br />o E «? c
<br />0- ¢ o" �
<br />JOB NO: 22-02351
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />S5
<br />
|