My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6417 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6417 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 11:04:32 AM
Creation date
2/18/2025 4:35:07 PM
Metadata
Fields
Template:
Building Plans
Street #
6417
Location
Beverly Hills Dr
Contractor
Lennar Home
Building Plans - Permit #
4150
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
iiL .1YL13 i .. ni �a an a.as�. xn r.�auasuurss s i 1`m <br />42" KNEE WALL WITH <br />/-lx8 CAP &CASING OR <br />36" <br />36" RAILING <br />3/4" PLYWOOD <br />/ DECKING -� <br />16 <br />14 <br />- 13I <br />iz <br />PRE-ENG FLOOR <br />\ <br />TRUSS <br />. <br />Ix TREAD (TYP) <br />\ <br />3/4" PLYWOOD <br />9 <br />DECKING <br />8, <br />, <br />2x6 LANDIN <br />\ \ <br />6 <br />1x RISERS (TYP.) <br />2x4 FRAMING <br />-i \\� 1 <br />5 <br />42- KNEE WALL WITH <br />r` <br />GERS <br />STRINGERS <br />__. <br />1x8 CAP & CASING OR <br />3/4" PLYWOOD <br />-_ <br />3 <br />36" RAILING <br />DECKING <br />Cl)\\ <br />2 <br />THRUST <br />2x6 LANDING - <br />1 <br />BLOCK <br />\ <br />2x4 FRAMING <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSI <br />36" H. CONT. <br />GRASPABLE <br />RAILING <br />TYP. STAIR SECTION <br />SCALE: 1 /4" = V-0" <br />2x4 THRUST <br />BLOCK <br />iirway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 and R302.7. <br />ler height: <br />riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading edges of the <br />acent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Pad depth: <br />s tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the vertical planes of <br />foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any <br />ht of stairs shall not exceed the smallest by more than 3/8 inch. <br />Ynder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the foremost <br />rojection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread depth of not less than 6 <br />fiches at any point within the clear width of the stair. <br />losings: <br />'he radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 inch and not <br />lore than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the <br />mallest nosing projection by more than 3/8 inch between two stories, including the nosing at the level of floors and landings. <br />leveling of nosings shall not exceed 1/2 inch. <br />landralls: <br />landrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. Handrail <br />eight measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less <br />tan 34 inches and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a <br />oint directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be <br />turned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than <br />1/2 inches between the wall and the handrails. <br />trip -size: <br />landrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater than 2 inches <br />r provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />3uards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30 <br />riches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. <br />Required guards at open -sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 <br />riches in height as measured vertically above the adjacent walking surface or the line connecting the leading edges of the <br />:reads. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a <br />>phere 4 inches in diameter. <br />Jnder-stair protection: <br />nclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the enclosed side <br />Nith 1/2-inch gypsum board. <br />rk SEE PLAN FOR LANDING DEPTH L <br />MIN. (3) 2x STUDS <br />@ END OF LANDIN <br />BELOW HDR, BEA <br />STANDARD (3) 2) <br />STRINGERS w/ <br />SIMPSON A35/UE <br />MP34 CLIP TO <br />FLOOR SYSTEM <br />LANDING FRAMII' <br />(2) 2x HDR. <br />REQ'D @ El' <br />LANDING F( <br />STRINGER <br />CONNECTI <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1 /4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />IV- <br />^�N <br />CONT. HANDRAIL <br />RETURN TO <br />WALL DETAIL <br />B SCALE: NTS <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L---------------------------------------J <br />OC REV 10.1.20 CAI <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT STUD SPECIES SPACING <br />SPF #2 <br />8'-0" 2x4 SYP #2 16" O.C. <br />SPF #2 <br />9'-0" 2x4 SYP #2 16" O.C. <br />SPF #2 <br />[L>9-f <br />2x6 SYP #2 16" O.C. <br />' WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUD: <br />@ 12" O.C.' <br />THIS /S ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />"" WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS" <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />EXTERIOR WALLS <br />REVISION NOTES 12/17/2009: <br />1. ALL CLOSETS THAT ARE NOT WALK-IN CLOSETS <br />ARE TO BE FRAMED DOWN TO 8'-0" A.F.F. <br />2. ALL BLOCK WALL FURRING IS TO BE 24" O.C. <br />EXCEPT IN WET AREAS. SPACE WET AREA <br />FURRING AT 16" O.C. <br />3. NO RECESSES FOR SHOWERS. SHOWERS ARE <br />TO BE PANNED WITH A PRE-FAB. BASE. <br />4. ALL VANITY HEIGHTS ARE 36" A.F.F. <br />5. SLIDING GLASS DOORS ARE TO HAVE A 1-1/2" <br />RECESS. REFER TO MASON'S SCOPE FOR <br />RECESS WIDTH. <br />6. ALL BATHROOMS HAVE ONE MEDICINE CABINET <br />7. ALL 50' PLANS. FRAME BAR TOP AT 40-1/2" A.F.F. <br />8. ALL TUB DECKS ARE SIZED AS FOLLOWS; <br />40' PRODUCT LINE - MIN. 48" x 64" <br />50' PRODUCT LINE - MIN. 48" x 76" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) -1 3/4" X 91/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />" VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />0 <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />CD <br />+28.3 / -37.0 <br />�E <br />+26.6 / -29.1F <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET HO SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />184X25i <br />S.H. <br />13 <br />20X38 <br />18}X37J <br />S.H. <br />14 <br />20X50 <br />18JX50 <br />S.H. <br />15 <br />20 X 63 <br />181 X 62 J <br />S.H. <br />16 <br />20 X 72 <br />181 X 714 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 251 <br />S.H. <br />1 H3 <br />27 1/4 X 38 <br />26 x 37 1 <br />S.H. <br />1 H4 <br />27 1 X 50 <br />26 x 50 <br />S.H. <br />1H5 <br />271 X 63 <br />26 X 62 112 <br />S.H. <br />1H6 <br />27 a X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 J X 3818 <br />36 1 X 37 3/4 <br />S.H. <br />24 <br />37 J X 501 <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 1 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 � WIDE <br />S.H. <br />32 <br />54 X 26 <br />521 X 251 <br />S.H. <br />33 <br />54X38J <br />52JX37i <br />S.H. <br />34 <br />54 X 501 <br />52 2 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 <br />S.H. <br />36 <br />54 X 72 <br />52 ' X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Table R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence 8 Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M 1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. I <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA 952 S.F. <br />SECOND FLOOR LIVING AREA 1121 S.F. <br />TOTAL LIVING AREA 2073 S.F. <br />GARAGE 396 S.F. <br />LANAI 104 S.F. <br />ENTRY 32 S.F. <br />TOTAL SQ. FT. 2605 S.F. <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONIC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />(GARAGE / LIVING) <br />R-11/13-13 KRAFT FACED <br />SECOND FLOOR PLAN - A <br />SCALE: Y4"=1'-O" <br />0 (D <br />cM <br />N U CV <br />N CO X <br />a <br />1,411' 0 1-- <br />CV <br />lip V N p (6 <br />� C: CN Y <br />N <br />O <br />C_ <br />tt, E Q <br />Q o 3 <br />v <br />U � <br />> <br />3 <br />a E <br />(Tr' 0 O O <br />'>W <br />� <br />\\\���\\�1111111i111/fI <br />WN '�Vf�''% <br />��` �FtO <br />Q':'•N5E •. <br />Q �o' OF <br />4•' F1.0¢' <br />OFE SS10't� <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W � <br />h <br />E n <br />N N <br />= N % J <br />0 � -a to LL <br />LL 5- <br />, ', <br />(n N3 .� LL W a <br />h My a Y <br />mJLL LL1g <br />LL <br />�'� <br />13V J 0 <br />in x <br />Z L ro � <br />f0 N tp 00' O J <br />W �rn ¢ a <br />5 <br />Z MG Joo <br />N <br />U L IL <br />LMn <br />06 rvn <br />Z ❑❑❑ <br />W <br />z � <br />z § <br />U a4 <br />N z <br />Cov� <br />L__,G) Il <br />W <br />V � <br />Ow <br />f13 <br />w <br />C) <br />0 <br />N <br />sr <br />� <br />ch <br />o <br />w <br />E <br />E <br />a <br />zo <br />0 <br />X V <br />ggqa <br />U <br />ZwZZ <br />S M� <br />aNi � <br />S <br />� <br />� � <br />.<ti <br />gFF <br />Zn� <br />to Jb <br />N <br />g� <br />iCL <br />WU <br />3: <br />=� <br />o <br />zI°d <br />0,31 <br />O <br />e <br />co <br />J <br />B <br />W <br />� <br />L <br />T <br />O <br />1� <br />m <br />0)N <br />C <br />Q N <br />Lo <br />T <br />m <br />(V <br />c T rri M <br />Z <br />E Q •' <br />E v :: <br />c <br />0- <br />0 _ ¢ o <br />0 <br />JOB <br />NO: 22-02351 <br />SCALE : AS NOTED <br />SHEET NO. <br />1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.