My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6417 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6417 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 11:04:32 AM
Creation date
2/18/2025 4:35:07 PM
Metadata
Fields
Template:
Building Plans
Street #
6417
Location
Beverly Hills Dr
Contractor
Lennar Home
Building Plans - Permit #
4150
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />10 a14 copper to Irghts & outlets <br />NEMA 1 <br />150 AMP/ <br />10 012 copper to 20 amp ckts <br />200AMP <br />00 #10-2 copper to WH <br />00 a10-3 copper to Dryer <br />__T <br />R <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />o <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />7I <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />J CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done In strict accordance With the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The Width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G. F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />0 <br />❑TV 2 <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RAN( <br />HOOD PER SPECS <br />1.5" VTR III 3" VTR <br />1111 �I\ <br />I <br />I I <br />I I <br />I ^ I <br />I \ \ \\, 1113rr VTR <br />PLUMBING RISER <br />SCALE: NTS <br />w <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ITCHEN <br />A/C PAD <br />DISC. WP <br />GFI <br />Ak <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />FIM TDB & GFI TO <br />— — — — — — — I BE ALIGNED <br />VERTICALLY <br />I <br />COACH LIGHTS '%, COACH LIGHTS <br />OR PREWIRE AS NI-1 / OR PREWIRE AS <br />PER SPECS / PER SPECS <br />SPEC 3 & 4 KITCHEN FIRST FLOOR ELECTRICAL PLAN - ELEV-A <br />SCALE: %4'=1'-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L-------------------------------------J <br />SECOND FLOOR ELECTRICAL PLAN <br />ELEV-A <br />� ~ O <br />N <br />a <br />N <br />Qm X <br />v <br />caLL� <br />N <br />-MCC <br />p N <br />Q0 <br />Ur <br />^` ?3 N <br />C: Q <br />12 0 <br />w _Cr E� <br />r6 N O •0 <br />;jam °W <br />N <br />O <br />CV <br />CV <br />0 <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />II- <br />co <br />o f <br />= <br />fJ <br />O N 8 N pip J <br />C/ J LL <br />Q <br />to <br />r ,� 00 Nat to <br />�CCM0� <br />o <br />LL 0. Y <br />LL u- a <br />Z <br />13 OC <br />0 <br />�o <br />rm°io <br />$ W <br />W�QjOi <br />ro ro o <br />¢�¢ <br />Z <br />IL (' <br />a <br />N V2 p¢¢:rn0 <br />0 c) _j y <br />Z <br />W <br />O <br />oo❑ <br />Z <br />z <br />a <br />U) <br />- N <br />z <br />Q) <br />�V) <br />.2LL <br />�U <br />C:1 <br />0 <br />W g <br />V^) <br />(✓ Ny <br />W W <br />8 <br />I <br />ti <br />Z <br />tl <br />o E <br />Q <br />8® <br />E <br />� <br />oa <br />w <br />Z <br />E <br />N <br />t <br />¢¢Oa <br />q Z <br />g <br />� <br />4? <br />N C <br />x <br />Z <br />J <br />b <br />8 <br />> § <br />a 3 <br />0. <br />U <br />y <br />p <br />J <br />'M <br />O <br />L <br />co <br />O <br />Cr <br />rr /� <br />vJ m <br />(0 <br />O <br />� <br />rn <br />o <br />LO <br />N <br />Q <br />N <br />r <br />r <br />4) <br />T� <br />C14 <br />iri <br />Z <br />Z <br />E <br />a <br />v <br />c <br />a <br />v _j <br />a o <br />JOB <br />NO: <br />22-02351 <br />SCALE : <br />AS NOTED <br />SHEET N0. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.