I -__ t-1 L !J L- 1_I - <br />- ' - - i ' _1 !II 1 I I II I I ,'I _ JI 1L 1- '__ <br />- LL_ <br />STRUCTURAL SPECIFICATIONS <br />MISCELLANEOUS <br />1. THE STRUCTURAL SYSTEM IS UNSTABLE UNTIL ALL CONNECTIONS HAVE BEEN <br />MADE AND ALL CONCRETE HAS REACHED ITS MINIMUM DESIGN STRENGTH, AS <br />SHOWN IN THE STRUCTURAL DOCUMENTS. <br />2. CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION <br />TO ENSURE THE SAFETY OF THE BUILDING UNTIL STRUCTURAL SYSTEM IS <br />COMPLETED. THIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION OF <br />WHATEVER TEMPORARY BRACING, SHORING, GUYS OR TIE DOWNS THAT MAY BE <br />NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE <br />PROPERTY OF THE CONTRACTOR AFTER COMPLETION OF THE PROJECT. <br />3. CONTRACTOR TO SUPPORT, BRACE AND SECURE EXISTING STRUCTURE AS <br />REQUIRED. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE SAFETY OF THE <br />BUILDING DURING CONSTRUCTION. <br />7. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE <br />REFERENCED BUILDING CODE. <br />8. COORDINATE ALL DIMENSIONS AND ELEVATIONS WITH THE ARCHITECTURAL <br />DRAWINGS. DO NOT SCALE DRAWINGS. <br />9. CONTACT ENGINEER WITH ANY QUESTIONS OR DISCREPANCIES FOUND ON <br />DRAWINGS. <br />10. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS, AND <br />CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. <br />11. SUBMIT SIGNED & SEALED SHOP DRAWINGS AS REQUIRED HEREIN. ALL <br />SUBMITTALS SHALL BE CHECKED AND SIGNED BY THE GENERAL CONTRACTOR AND <br />SIGNED AND SEALED BY THE DELEGATED ENGINEER, WHERE SPECIFIED HEREIN. <br />12. SUBMIT ONE PRINT AND ONE REPRODUCIBLE OF ALL SHOP DRAWINGS. <br />IT IS THE FULL RESPONSIBILITY OF THE G. C. TO CHECK COLRD. <br />VERIFY THE CONFORMANCE OF SHOP DRAWINGS WITH CONTRACT DOCUMENTS. <br />AND APROVE ALL SHOP DRAWINGS. <br />13. ANY CHANGES TO THE STRUCTURE SHALL HAVE BEEN REVIEWED AND <br />APPROVED IN WRITING BY THE ENGINEER PRIOR TO COMMENCING WORK ON <br />ITEMS AFFECTED. <br />14. CONTRACTOR SHALL NOTIFY THE BUILDING DEPT. WHEN THE STRUCTURAL SYSTEM <br />IS SUBSTANTIALLY COMPLETED, AND BEFORE SHEATHING, CEILINGS, OR ROOFING IS <br />INSTALLED. <br />SITE WORK <br />1. A SUBSURFACE INVESTIGATION IS TO BE COMPLETED AT THE PROJECT SITE BY A FL <br />LICENSED P.E. BORING LOGS AND SITE PREPARATION PROCEDURES SHALL BE <br />INCLUDED IN THE PROJECT SOILS REPORT, WHICH WILL BE AN INTEGRAL PART OF <br />THESE CONTRACT DOCUMENTS. <br />2. ALL SITE WORK INCLUDING STRIPPING, BACK FILLING & PROOF ROLLING SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SOILS REPORT. <br />3. SINCE DESIGN SOIL BEARING PRESSURE INFO. WAS NOT AVAILABLE AT THE <br />TIME THESE DRAWINGS WERE PREPARED, A SOIL BEARING PRESSURE CAPACITY <br />OF 1500 PSF WAS ASSUMED. (CONTRACTOR VERIFY) <br />6. FOUNDATION WALLS THAT RETAIN EARTH SHALL BE BRACED AGAINST <br />BACKFILLING PRESSURES UNTIL FLOOR SLABS AT TOP AND BOTTOM ARE IN <br />PLACE. <br />7. THE SIDES OF FOOTINGS MAY BE EARTH FORMED IF THE EXCAVATION CAN BE <br />KEPT VERTICAL, CLEAN, AND STABLE, OTHERWISE, PLYWOOD FORMS MUST BE <br />USED. IF EARTH SIDE FORMS ARE TO BE USED, INCREASE FOOTING DIMENSIONS <br />BY 2". <br />8. EXERCISE CARE WHEN COMPACTING NEAR ADJACENT STRUCTURES. FOLLOW <br />THE RECOMMENDATIONS IN THE SOILS REPORT AND DOCUMENT EXISTING <br />CONDITIONS WITH PHOTOGRAPHS PRIOR TO STARTING WORK. <br />CAST IN PLACE CONCRETE <br />1. ALL CAST IN PLACE CONCRETE WORK INCLUDES REINFORCING STEEL AND <br />RELATED WORK SHOWN INCLUDING FORMWORK, SETTING ANCHOR BOLTS, PLATES, <br />FRAMES, DOWELS FOR MASONRY OR OTHER ITEMS EMBEDDED IN CONCRETE. <br />2. APPLICABLE STANDARDS <br />ACI NUMBER TITLE <br />117 STANDARD SPECIFICATIONS FOR TOLERANCES FOR CONCRETE <br />CONSTRUCTION <br />226 GROUND GRANULATED BLAST FURNACE SLAG <br />301 STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR <br />BUILDINGS <br />302 GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION <br />304 GUIDE FOR MEASURING MIXING, TRANSPORTING AND PLACING <br />CONCRETE <br />304.2 R91 PLACING CONCRETE BY PUMPING METHODS. <br />305R HOT WEATHER CONCRETING <br />306R COLD WEATHER CONCRETING <br />308 STANDARD PRACTICE FOR CURING CONCRETE <br />309R GUIDE FOR CONSOLIDATION OF CONCRETE <br />315 MANUAL OF STANDARD PRACTICE FOR DETAILING CONCRETE <br />STRUCTURES <br />318 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE <br />347 RECOMMENDED PRACTICE FOR CONCRETE FORMWORK <br />63 RECOMMENDED PRACTICE FOR PLACING REINFORCING BARS <br />3. CONCRETE MATERIALS <br />a) PORTLAND CEMENT: ASTM C 150, TYPE I <br />b) AGGREGATES: NORMAL WEIGHT CONCRETE, COARSE AND FINE, ASTM C33 <br />c) AIR -ENTRAINING: ASTM C260 <br />d) WATER REDUCING: ASTM C494, TYPE A <br />e) WATER: FRESH, CLEAN AND POTABLE <br />f) NO ACCELERATORS, RETARDERS OR ADMIXTURES CONTAINING CHLORIDES <br />WILL BE PERMITTED <br />FLY -ASH: ASTM C618, CLASS F, 20% MAXIMUM BY WEIGHT. DO NOT <br />USE FOR EXPOSED SLABS OR ARCHITECTURAL CONCRETE. <br />h) SUPER PLASTICIZER: ASTM C494, TYPE F OR G, WHERE AUTHORIZED BY <br />THE ENGINEER. <br />i) GROUND GRANULATED BLAST FURNACE SLAG CEMENT: ASTM C989, <br />% MAXIMUM BY WEIGHT. <br />j) MAXIMUM AGGREGATE SIZE: FOOTINGS = #57, OTHERS #67 <br />4. REINFORCING MATERIALS <br />a) DEFORMED BARS: ASTM A615, GRADE 60 <br />b) SMOOTH DOWELS: ASTM A615, PLAIN BARS, MINIMUM YIELD STRENGTH OF <br />60,000 PSI. <br />c) WELDED WIRE FABRIC: ASTM A185, PLAIN WIRE FABRIC IN FLAT SHEETS <br />ONLY. <br />d) ACCESSORIES TO CONFORM TO ACI 315. <br />e) WHERE CONCRETE SURFACES ARE EXPOSED, MAKE THOSE PORTIONS OF <br />ALL ACCESSORIES IN CONTACT WITH THE CONCRETE SURFACE OR WITHIN 1 /2 <br />INCH THEREOF, OF PLASTIC OR STAINLESS STEEL. <br />5. PROVIDE THE FOLLOWING MINIMUM CONCRETE STRENGTHS AT 28 DAYS: <br />a) FOOTINGS, SLAB -ON -GRADE = 3000 PSI <br />b) MASONRY WALL BEAMS = 3000 PSI <br />c) FORMED COLUMNS, BEAMS = 3000 PSI <br />6. CONCRETE MUST BE BATCHED, MIXED AND TRANSPORTED IN ACCORDANCE <br />WITH THE SPECIFICATIONS FOR READY MIXED CONCRETE ASTM C94. <br />7. REQUIRED SLUMP = 4 PLUS OR MINUS ONE INCH. <br />8. CONCRETE MUST BE PLACED WITHIN 90 MINUTES OF BATCH TIME. <br />9. DO NOT ADD WATER AT THE JOB SITE WITHOUT APPROVAL OF THE PROJECT <br />SUPERINTENDENT. DO NOT EXCEED THE SLUMP LIMITATION. USE ONLY COLD <br />WATER FROM THE TRUCK TANK. ANY ADDED WATER MUST BE INDICATED ON <br />THE DELIVERY TICKET PLUS THE NAME OF THE PERSON AUTHORIZING. <br />10. LAP SPLICE ALL BARS 30 DIAMETERS MINIMUM UNLESS OTHERWISE SHOWN <br />OR NOTED. <br />11. PROVIDE CORNER BARS AT ALL WALL FOOTING, WALL AND BEAM CORNERS. <br />SIZE AND NUMBER TO MATCH HORIZONTAL BARS. <br />12. ALL REINFORCEMENT SHALL BE FASTENED AND SECURED TOGETHER TO <br />PREVENT DISPLACEMENT BY CONSTRUCTION LOADS OR THE PLACING OF <br />CONCRETE. <br />13. REINFORCING BAR COVER <br />a) FOOTINGS 3" <br />b) COLUMNS AND BEAMS 1 1/2" <br />c) SLABS 3/4" (INTERIOR) 1 1/2" (EXTERIOR) <br />14. SELECT PROPORTIONS IN ACCORDANCE WITH ACI 301 TO PROVIDE CONCRETE <br />CAPABLE OF BEING PLACED WITHOUT EXCESSIVE SEGREGATION AND WITH <br />ACCEPTABLE FINISHING PROPERTIES, DURABILITY, SURFACE HARDENERS, <br />APPEARANCE, AND STRENGTH REQUIREMENTS REQUIRED BY THESE <br />SPECIFICATIONS. <br />15. CHAIR WELDED WIRE FABRIC REINFORCING AT SO" ON CENTER MAXIMUM. <br />16. MAXIMUM WATER TO CEMENT RATIO WHEN NO BACK-UP DATA IS AVAILABLE: <br />a) 4000 PSI, 28 DAY COMPRESSIVE STRENGTH; W/C RATIO, 0.44 <br />MAXIMUM (NON AIR ENTRAINED), 0.36 MAXIMUM (AIR ENTRAINED). <br />b) 3000 PSI, 28 DAY COMPRESSIVE STRENGTH; W/C RATIO, 0.58 <br />MAXIMUM (NON AIR ENTRAINED), 0.47 MAXIMUM (AIR ENTRAINED). <br />17. DATA TO BE SUBMITTED: <br />a) INTENDED USAGE AND LOCATION FOR EACH TYPE <br />b) MIX DESIGN FOR EACH TYPE <br />c) CEMENT CONTENT IN POUNDS -PER -CUBIC YARD <br />d) COARSE AND FINE AGGREGATE IN POUNDS/CUBIC YARD <br />e) WATER CEMENT RATIO BY WEIGHT <br />f) CEMENT TYPE AND MANUFACTURER <br />g) SLUMP RANGE <br />h) AIR CONTENT <br />i) ADMIXTURE TYPE AND MANUFACTURER <br />j) PERCENT ADMIXTURE BY WEIGHT <br />k) STRENGTH TEST DATA REQUIRED TO ESTABLISH MIX DESIGN. <br />1) COMPLETE DETAIL AND PLACING SHOP DRAWINGS FOR ALL REINFORCING <br />STEEL INCLUDING ACCESSORIES THAT HAVE BEEN REVIEWED AND STAMPED BY <br />THE GENERAL CONTRACTOR. INCLUDE ALL REQUIRED DIMENSIONS AND ELEVATIONS <br />(IE. TOP OF CONCRETE). <br />18. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE <br />CONSTRUCTION OF ALL FORMWORK, SHORING AND RESHORING IN ACCORDANCE <br />WITH ACI 347. <br />a) FORM AND SHORING DESIGN BY A PROFESSIONAL ENGINEER REGISTERED <br />IN THE STATE OF FLORIDA. <br />b) EARTH CUTS MAY BE USED AS FORMS FOR FOOTING VERTICAL SURFACES: <br />INCREASE SIZE BY TWO INCHES. <br />19. SUBMIT FORM WORK AND SHORING DRAWINGS TO LOCAL BUILDING <br />DEPARTMENT WHEN REQUIRED BY FLORIDA THRESHOLD LAW. <br />20. CONSTRUCTION JOINTS NOT SHOWN ON THE DRAWINGS MUST BE MADE AND <br />LOCATED TO LEAST IMPAIR THE STRENGTH OF THE STRUCTURE. <br />a) NO HORIZONTAL CONSTRUCTION JOINTS WILL BE PERMITTED IN BEAMS, <br />AND SLABS. <br />b) LOCATION OF ANY CONSTRUCTION JOINT NOT SHOWN IS SUBJECT TO <br />REVIEW AND ACCEPTANCE BY ENGINEER. <br />21. INTERNAL VIBRATION, PROPERLY APPLIED IS THE REQUIRED METHOD OF <br />CONSOLIDATING PLASTIC CONCRETE. <br />22. PROVIDE 3/4" CHAMFER ON ALL EXPOSED CORNERS OF COLUMNS, BEAMS <br />AND WALLS UNLESS OTHERWISE NOTED ON ARCHITECTURAL DRAWINGS. <br />23. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL OPENINGS, SLEEVES, AND <br />SLAB RECESSES AS REQUIRED BY OTHER TRADES BEFORE CONCRETE IS PLACED. <br />NO SLEEVE, OPENINGS, OR INSERT MAY BE PLACED IN BEAMS, JOISTS, OR <br />COLUMN UNLESS APPROVED BY THE ENGINEER. <br />24. CONTRACTOR SHALL VERIFY EMBEDDED ITEMS INCLUDING, BUT NOT LIMITED <br />TO, ANCHOR BOLTS, BOLT CLUSTERS, WELD PLATES, ETC., BEFORE PLACING <br />CONCRETE. NOTIFY ENGINEER OF ANY CONFLICTS WITH REBAR. <br />25. SEE DRAWINGS FOR REQUIRED CONCRETE FINISHES. <br />26. SLOPE ALL BALCONIES AND WALKWAYS TO DRAIN AWAY FROM THE BUILDING. <br />27. ALL BUILDING SITE AND SLABS -ON -GRADE SHALL BE 4" MINIMUM <br />THICKNESS. <br />a) REINFORCED WITH 6X6, W1.4 X W1.4 W.W.F. <br />b) PLACED ON 6 MIL POLYETHYLENE VAPOR BARRIER. LAP 6" AND TAPE <br />ALL JOINTS. <br />c) SAW CUT CONTROL JOINTS ® LESS THAN OR EQUAL TO 15'-0" EACH WAY. <br />d) SEE DRAWINGS FOR ANY ADDITIONAL CONDITIONS. <br />28. TESTING <br />a) A QUALIFIED TESTING LAB SHALL BE RETAINED TO PERFORM QUALITY <br />CONTROL WORK AND ON SITE TESTING. <br />b) AIR TEST. ASTM C231 <br />c) SLUMP TEST: ASTM 143 <br />d) MOLD AND CURE TEST CYLINDERS (ASTM C31) AND TEST CYLINDERS FOR <br />STRENGTH (ASTM C39). TAKE ONE TEST. FOUR CYLINDERS FOR EACH DAYS <br />POUR OF 50 CUBIC YARDS, OR FRACTION THEREOF. TEST ONE CYLINDER AT 7 <br />DAYS, TWO AT 28 DAYS AND ONE HOLD. <br />e) ONE COPY OF ALL TEST REPORTS SHALL BE SENT DIRECTLY TO THE <br />OWNER, ENGINEER, ARCHITECT AND GENERAL CONTRACTOR. <br />29. CONTRACTOR SHALL PROVIDE FLATNESS AND LEVELNESS IN CONCRETE <br />SLABS PER ACI 302.1R, FIG. 8.15.1.1 MINIMUM REQUIRED "F" NUMBERS FOR <br />TYPE OF SLAB USE. REFER TO ACI 117 FOR FLOOR TOLERANCES. <br />30. REPAIR ANY CRACKS OR DEFECTIVE AREAS THAT WILL RESTORE THE <br />AFFECTED SURFACE OR AREAS TO THEIR FULL DESIGN STRENGTH AND <br />APPEARANCE. CONTACT THE STRUCTURAL ENGINEER FOR ADVICE AND <br />EVALUATION. <br />31. ACCEPTANCE OF THE STRUCTURE WILL BE MADE IN CONFORMANCE WITH <br />ACI 301. <br />PRECAST CONCRETE U-LINTELS AND SILLS <br />1. UNITS SHALL BE FABRICATED BY A FIRM ENGAGED IN THE MANUFACTURING <br />OF PRECAST AND PRE -STRESSED CONCRETE U-LINTELS AND SILLS FOR A <br />MINIMUM OF 5 YEARS. FABRICATOR SHALL HAVE A QUALITY ASSURANCE <br />PROGRAM THAT COMPLIES WITH THE PROCEDURES OF MANUAL 116 BY THE <br />PRECAST/PRE-STRESSED CONCRETE INSTITUTE PCI). <br />2. PLANT RECORDS OF PRODUCTION AND QUALITY CONTROL SHALL BE KEPT IN <br />ACCORDANCE WITH PCI RECOMMENDATIONS AND MADE AVAILABLE UPON REQUEST <br />FOR THE ARCHITECT/ENGINEER. <br />3. CODES AND STANDARDS: <br />a) AMERICAN SOCIETY FOR TESTING AND MATERIALS(ASTM) <br />1) C33 - SPECIFICATION FOR CONCRETE AGGREGATES <br />2) C150 - SPECIFICATION FOR PORTLAND CEMENT <br />b) PRECAST/PRE-STRESSED CONCRETE INSTITUTE (PCI) STANDARDS: MANUAL <br />FOR QUALITY CONTROL FOR PRECAST AND PRE -STRESSED CONCRETE MNL-116. <br />c) AMERICAN CONCRETE INSTITUTE: BUILDING CODE REQUIREMENTS FOR <br />STRUCTURAL CONCRETE (ACI 318) <br />d) AMERICAN CONCRETE INSTITUTE: BUILDING CODE REQUIREMENTS FOR <br />MASONRY STRUCTURES ACI 530) <br />4. CONCRETE MATERIALS: <br />a) PORTLAND CEMENT. ASTM C150 TYPE I OR III, GRAY COLOR <br />b) AGGREGATES: ASTM C33 <br />c) WATER: POTABLE <br />d) ADMIXTURES: SHALL NOT CONTAIN CALCIUM CHLORIDE OR CHLORIDE IONS <br />5. REINFORCING <br />a) DEFORMED REINFORCEMENT: ASTM A615 GRADE 40 OF 60. <br />b) PRE -STRESSING STRAND: ASTM A416 270 KSI LL. <br />6. ALL U-LINTEL UNITS 14 FEET IN OVERALL LENGTH AND SHORTER SHALL BE <br />MADE OF CONCRETE WITH A MINIMUM STRENGTH OF 3500 PSI AT 28 DAYS. <br />7. ALL U-LINTEL UNITS EXCEEDING 14 FEET IN OVERALL LENGTH SHALL BE <br />MADE OF CONCRETE WITH A MINIMUM STRENGTH OF 6000 PSI AT 28 DAYS AND <br />SHALL BE PRE -STRESSED CONCRETE. <br />8. ALL SILL UNITS SHALL BE MADE OF CONCRETE WITH A MINIMUM STRENGTH <br />OF 3000 PSI AT 28 DAYS. <br />9. ALL UNITS SHALL BE SAND BLOCK FINISH EXCEPT PRE -STRESSED, 6" WIDE, <br />AND 12" WIDE U-LINTELS SHALL BE SMOOTH FORM FINISHED. <br />10. SUBMITTALS <br />a) PROVIDE MANUFACTURER'S CATALOG ENGINEERING DATA. <br />b) MANUFACTURER SHALL RATE U-LINTEL UNITS FOR GRAVITY, UPLIFT, AND <br />LATERAL LOADS IN UNITS OF POUNDS PER LINEAR FOOT. <br />FIBROUS REINFORCING (ALTERNATE TO W.W.F. IN SLAB ON GRADE) <br />1. REINFORCING FIBERS TO BE VIRGIN 100 % POLYPROPYLENE FIBERS, <br />SPECIFICALLY MANUFACTURED FOR USE IN CONCRETE, CONTAINING NO <br />REPROCESSED OLEFIN MATERIALS, WITH THE FOLLOWING MINIMUM PHYSICAL <br />CHARACTERISTICS: <br />a) SPECIFIED GRAVITY: 0.91 <br />b) YOUNG'S MODULUS 0.5 (3.5 kn/mm2 <br />c) TENSILE STRENGTH: 45 TO 60 KSI <br />d) LENGTH: 3/4" MAXIMUM, MULTI GRADATION DESIGN. <br />2. REINFORCING FIBERS TO BE SUPPLIED BY THE FOLLOWING APPROVED <br />MANUFACTURERS: <br />a) "FIBERSTRAND 100", EUCLID CHEMICAL COMPANY <br />b) "FIBERMESH INFORCE e3 OR STEALTH e3", SI CONCRETE SYSTEMS <br />c) "FORTA ECONO NET", FORTA CORPORATION <br />d) "NYCON SUPER FIBERS", NYCON, INC. <br />3. FIBERS TO BE ADDED IN MANUFACTURER'S APPROVED AMOUNT WITH A <br />MINIMUM OF 1.5 LBS PER CUBIC YARD FOR POLY AND NYLON. <br />4. CONCRETE TO BE MIXED IN ACCORDANCE WITH FIBER MANUFACTURER'S <br />RECOMMENDATIONS FOR UNIFORM AND COMPLETE DISPERSION OF FIBER BUNDLES <br />INTO SINGLE MONOFILAMENTS WITHIN CONCRETE. <br />5. REINFORCING FIBERS ONLY TO BE USED IN CONCRETE SLAB ON GRADES, AND <br />NOT IN PRECAST PLANK OR METAL DECK TOPPING SLABS. <br />6. FOR A "NONE HAIRY" FINISH, USE A MONOFILAMENT FIBER. MORE <br />DEMANDING APPLICATIONS, USE A COLLATED FIBRILLATED FIBER, WHICH WILL <br />WEAR AWAY OVER TIME. <br />MASONRY <br />1. HOLLOW LOAD BEARING UNITS SHALL CONFORM TO ASTM C90, NORMAL <br />WEIGHT, TYPE II. MINIMUM NET COMPRESSIVE UNIT STRENGTH = 2000 PSI. <br />(NET AREA COMPRESSIVE MASONRY STRENGTH f'm = 1500 PSI). <br />2. MORTAR SHALL BE TYPE M OR S AND CONFORM TO ASTM C270 PROPORTION <br />OR PROPERTY SPECIFICATION) WITH A MINIMUM AVERAGE COMPRESSIVE STRENGTH <br />AT 28 DAYS OF 2500 PSI (TYPE M) AND 1800 PSI (TYPE S). <br />3. COARSE GROUT SHALL CONFORM TO ASTM C476: <br />a) 2500 PSI AT 28 DAYS. <br />b) 1/4" MAXIMUM AGGREGATE. <br />c) 8" TO 11" SLUMP. <br />4. CODES AND STANDARDS: <br />a) SPECIFICATIONS FOR MASONRY STRUCTURES - ACI 530.1 /ASCE <br />6/TMS 602 IS INCLUDED BY REFERENCE IN ITS ENTIRETY. <br />b) BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES: ACI <br />530/ASCE 5 99/TMS 402. <br />5. A REINFORCED MASONRY BOND BEAM SHALL BE PROVIDED IN ALL WALLS <br />SHOWN ON THE STRUCTURAL DRAWINGS AT EACH FLOOR, AND ROOF. <br />USE GALVANIZED MESH TYPE CELL CAPS. <br />BEAM CORNERS TO MATCH HORIZONTAL BARS. PROVIDE CORNER BARS AT ALL <br />6. UNLESS NOTED OTHERWISE, TIE BEAMS SHALL BE AS FOLLOWS: <br />a ROOF LEVEL: ONE COURSE OF KNOCK OUT BLOCK WITH (1) #5 CONT. <br />b FLOOR LEVEL: TWO COURSE OF K. 0. BLOCK WITH (1) #5 CONT. IN EA. COURSE. <br />7. VERTICAL BARS SHALL BE HELD IN POSITION AT THE TOP AND BOTTOM OF <br />BAR AND AT 8'0" O.C. MAXIMUM WITH A MINIMUM CLEARANCE OF 1/2" FROM <br />MASONRY. THE CLEAR DISTANCE BETWEEN BARS SHALL NOT BE LESS THAN ONE <br />BAR DIAMETER, NOR LESS THAN 1". CENTER BARS IN WALLS U.N.O. <br />8. VERTICAL REINFORCING SHALL BE AS SHOWN ON THE DRAWINGS. FILL CELLS <br />WITH COARSE GROUT AS SPECIFIED. PROVIDE ACI 90 DEGREE STANDARD HOOKS <br />INTO F0011NG AND ROOF TIE BEAM. LAP SPLICE VERTICAL REINFORCEMENT <br />ABOVE FOOTING AND ABOVE EACH FLOOR LEVEL UNLESS NOTED OTHERWISE. <br />MAINTAIN VERTICAL REINFORCING SHOWN ON PLANS ABOVE AND BELOW MASONRY <br />OPENINGS EXCEEDING 10'0" CLEAR. CONTINUE FOUNDATION DOWELS BELOW ALL <br />MASONRY OPENINGS. <br />9. ALL REINFORCED FILL CELLS ARE TO BE CLEAN AND FREE OF ANY FOREIGN <br />MATERIAL OR DEBRIS. REMOVE ANY INSULATING MATERIAL FROM CELLS, <br />INCLUDING POLYSTYRENE INSULATING INSERTS, PRIOR TO GROUT POUR. <br />10. REINFORCING BARS SHALL BE STRAIGHT EXCEPT FOR BENDS AROUND <br />CORNERS AND WHERE BENDS OR HOOKS ARE DETAILED ON THE PLANS. <br />11. REINFORCING BARS SHALL BE LAPPED 48 BAR DIAMETERS WHERE SPLICED <br />AND SHALL BE WIRED TOGETHER. <br />12. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE, <br />IT SHALL NOT BE SLOPED MORE THAN ONE HORIZONTAL IN SIX VERTICALS. <br />DOWELS SHALL BE GROUTED INTO A CORE IN VERTICAL ALIGNMENT, EVEN <br />THOUGH IT IS IN AN ADJACENT CELL TO THE VERTICAL WALL REINFORCEMENT. <br />13. PROVIDE HORIZONTAL WALL REINFORCING (9 GA.) GALVANIZED LADER TYPE <br />DUR 0 WALL (OR EQUIVALENT) AT 16" O.C. JOINT REINFORCING SHALL CONFORM <br />TO ASTM A 951. <br />14. PROVIDE HORIZONTAL JOINT REINFORCEMENT AT DOORS AND WINDOWS <br />FOR FIRST AND SECOND BLOCK COURSE ABOVE AND BELOW APERTURES. RUN <br />REINFORCING CONTINUOUS OR EXTEND TWO FEET FROM APERTURE EDGE. <br />15. WIRE REINFORCEMENT SHALL BE LAPPED AT LEAST 6" AT SPLICES AND <br />SHALL CONTAIN AT LEAST ONE CROSS WIRE OF EACH PIECE OF REINFORCEMENT <br />IN THE LAPPED DISTANCE. <br />16. CLEANOUTS SHALL BE PROVIDED IN THE BOTTOM COURSE OF MASONRY IN <br />EACH GROUT POUR WHEN THE POUR HEIGHT EXCEEDS 5'. CLEANOUTS TO BE <br />SAW CUT 4" X 4". <br />17. GROUT POUR HEIGHT SHALL NOT EXCEED 24'. PLACE GROUT IN 5' <br />MAXIMUM LIFTS HEIGHTS. <br />18. CONSOLIDATE GROUT POURS AT THE TIME OF PLACEMENT BY MECHANICAL <br />MEANS AND RECONSOLIDATE AFTER INITIAL WATER LOSS AND SETTLEMENT. <br />19. STORE BLOCKS ON PALLETS AND COVER WITH VISQUEEN. <br />20. PLACE ALL MASONRY IN RUNNING BOND WITH 3/8" MORTAR JOINTS. <br />PROVIDE COMPLETE COVERAGE FACE SHELL MORTAR BEDDING, HORIZONTAL AND <br />VERTICAL. FULLY MORTAR WEBS IN ALL COURSES OF PIERS, COLUMNS, AND <br />PILASTERS AND ADJACENT TO GROUTED CELLS. <br />21. SEE DRAWINGS FOR MASONRY CONTROL JOINT LOCATIONS. SPACE AT <br />26'0" O.C. AT EXTERIOR WALLS, 32'0" O.C. AT INTERIOR WALLS UNLESS NOTED <br />OTHERWISE. <br />22. MASONRY INSPECTION SHALL BE PROVIDED BY A QUALIFIED AGENT IN <br />ACCORDANCE WITH ACI 530. <br />a) NON -ESSENTIAL STRUCTURES: LEVEL 2, TABLE 1.14.1.2 <br />23. SUBMITTALS: <br />a) SUBMIT PROPOSED GROUT MIX DESIGN PRIOR TO CONSTRUCTION. <br />b) SUBMIT PROPOSED MORTAR MIX DESIGN PRIOR TO CONSTRUCTION. <br />c) SUBMIT DETAILED SHOP DRAWINGS OF REINFORCING BARS SHOWING <br />NUMBER, SIZE, AND LOCATION. INCLUDE BAR LISTS AND BEND DIAGRAMS. <br />INCLUDE ALL REQUIRED DIMENSIONS AND ELEVATIONS. <br />d) SUBMIT COMPRESSIVE STRENGTH TESTS OF PROPOSED MASONRY UNITS <br />PRIOR TO CONSTRUCTION. MASONRY UNITS ARE TO BE TESTED IN ACCORDANCE <br />WITH ASTM C140. <br />24. A QUALIFIED TESTING LABORATORY SHALL BE RETAINED TO PERFORM THE <br />FOLLOWING TESTS: <br />a) SAMPLE AND TEST GROUT IN ACCORDANCE WITH ASTM C1019 FOR <br />EACH 5000 SQ. FT. OF MASONRY. <br />b) SLUMP TESTS: ASTM C143. <br />c) MASONRY PRISM TEST IN ACCORDANCE WITH ASTM E447, METHOD B, <br />MODIFIED AS FOLLOWS: ONE SET OF 3 PRISMS PRIOR TO CONSTRUCTION AND <br />DURING CONSTRUCTION FOR EACH 5000 SQ. FT. OF WALL. <br />25. PROVIDE 8" DEEP PRECAST REINFORCED CONCRETE LINTELS OVER ALL <br />MASONRY OPENINGS NOT SHOWN TO HAVE A STRUCTURAL BEAM. MINIMUM END <br />BEARING = 8". LINTEL WIDTH TO MATCH MASONRY WIDTH. <br />26. TOPS OF PARTIALLY CONSTRUCTED WALLS SHALL BE COVERED WITH <br />VISQUEEN WHENEVER RAIN OCCURS AND AT THE END OF THE WORK DAY. <br />HAND RAILS <br />1. AND ENGINEER REGISTERED IN THE STATE OF FL SHALL DESIGN RAILING <br />SYSTEM AND CONNECTION OF IT TO THIS STRUCTURE. <br />2. SUBMIT SHOP DRAWINGS BEARING THE EMBOSSED SEAL AND THE SIGNATURE <br />OF THE ENGINEER FOR REVIEW PRIOR TO FABRICATION. <br />3. THE CONFIGURATION OF THE RAILING SYSTEM SHALL BE AS SHOWN <br />ON THE ARCHITECTURAL DRAWINGS. <br />4. RAILING SYSTEM AND CONNECTIONS SHALL BE DESIGNED FOR <br />APPLICABLE LOADS AS INDICATED ON THE PLANS AND IN THE BUILDING <br />CODE. THE LOADS SHALL BE CLEARLY INDICATED ON SHOP DRAWINGS. <br />5. SHOP DRAWINGS SHALL SHOW AND SPECIFY CONNECTIONS UTILIZED WITHIN <br />THE RAILING SYSTEM AS WELL AS CONNECTIONS TO AND LOADS IMPOSED UPON <br />THE STRUCTURAL SYSTEM SHOWN ON THESE PLANS. <br />THERMAL & MOISTURE PROTECTION: <br />SEE ATTACHED ROOF SPECIFICATION F BUILT <br />1) S C ON OR INFO ON B L UP ROOF <br />2) ALL ROOFING TO BE TIMBERLINE FIBERGLASS SHINGLES BY GAF OR <br />EQUAL RIDGE VENTS TO BE INSTALLED PER ROOF PLAN. <br />3) ROOFING UNDERLAYMENT TO BE 45# FELT. <br />4) PROVIDE 26 GA. GALV. METAL OR PAINTABLE 0.19 GA. ALUMINUM <br />ALUMINUM FLASHINGS. VALLEYS AND DRIP EDGES. <br />5) BUM BASE SEALANT SHALL BE USED UNDER ALL EXTERIOR DOOR <br />THRESHOLDS AND CAULKING COMPOUND AT ALL DOORS, WINDOWS <br />& OTHER AREAS AS REQ. <br />6) INSULATION: <br />R-19 FIBERGLASS BATT FOIL FACED INSULATION IN EXT. STUD WALLS <br />AND FLOORS WITH EXPOSED SOFFITS. <br />R-14 "CORE -FILL 500" EXPANDING FOAM INSULATION IN ALL EXT. <br />MASONRY WALLS <br />R-30 FIBERGLASS BATT FOIL FACED INSULATION IN ATTIC SPACE. <br />RIGID INSULATION ON VENTILATED METAL DECK FOR ROOF. SEE ROOF SPEC. <br />7) ALL FASCIAS TO BE PVC COATED ALUMINUM AND SOFFITS TO BE VENTED VINYL. <br />8) CEMEN11T10US COATING TO BE 7/8" THICK POLYMER MODIFIED (PM) OR TRADITIONAL CEMENT <br />STUCCO W/ PAPER BACKED METAL LATH & " TYVEK STUCCO WRAP" 0 WOOD & METAL STUD <br />ONAL <br />CEMENTCSTUCCORAT MASONRY. BANDS OUS COATING TO BE S/SHALL BIEKFO MYGLUEDER TO MODIFIED )) EXISTING W/ OR SANDRTEXTURE. <br />DATE: MARCH 15TH 2O20 <br />SCALE: AS NOTED <br />DRAWN:J. WASILEWSKI <br />O <br />o0 <br />UJ <br />O <br />L0 <br />O� <br />XN <br />_ <br />LL U <br />_j <br />oo <br />m <br />� <br />wQ(y)oU <br />Lo <br />Zpcy)L0*k <br />- <br />J M LU <br />Z <br />IL N w <br />C� qt <br />N `n W <br />M <br />� co�00DTU <br />(D <br />J o0 J <br />Lj <br />Co <br />cj) <br />.0 <br />M j <br />O <br />cy) Lr) <br />WOJ <br />J 3: <br />LL <br />U) Z) <br />0 <br /><LlJwpcfl <br />~ <br />T-- 00 <br />0 Q <br />o0 UD <br />QU<Lo <br />= O <br />I <br />UL0 <br />Lu <br />JC%4 <br />�,r--Ur-,� <br />DUPLEX RESIDENCE <br />6554 BRENTWOOD DR. <br />ZEPHYRHILLS, FL <br />NOTES <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THE <br />ATTACHED DESIGN AND FOUND IT TO BE IN <br />COMPLIANCE WITH THE <br />STRUCTURAL <br />PROVISIONS OF THE <br />FLORIDA BUILDING CODE <br />2020 SEVENTH EDITION <br />THE ENGINEER HAS NOT REVIEWED THE <br />PRE-ENGINEERED T <br />LAYOUT TO DETER <br />US MANUFATURER'S <br />N Y LOAD BRG. <br />CONDITIONS AND R <br />R ES THE RIGHT TO <br />MAKE ANY CHANGE <br />A R TRUSS LOAD <br />INFORMATIO S <br />P I D TO THE ENGINEER. <br />SEAL <br />UAL ONLY <br />E/y''•• <br />�,�• <br />O 1�586 ':•' <br />OF <br />•'��� <br />>t>t n u <br />Ni <br />