My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6552 & 6554 Brentwood Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6552 & 6554 Brentwood Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 11:05:39 AM
Creation date
2/18/2025 4:35:33 PM
Metadata
Fields
Template:
Building Plans
Street #
6552 & 6554
Location
Brentwood Dr
Contractor
Duplex Homepro
Building Plans - Permit #
2491 & 2492
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I I III II I I L II I I ' <br />�i <br />Am <br />i_Rll <br />2I41 t 16' 41 1 1 1 21-4"1 fS2 THINCKEND SLAB <br />401-811 <br />FOUNDATION PLAN <br />i X 10/10 WWF <br />3ARRIER <br />Y COMPACTED, <br />FILL <br />�1 <br />2 0- Ili #5 DOWEL W! <br />LO il�l 10" HOOK 4" TH CONC SLAB <br />N i W/ 6x6 10/10 WWF <br />\i �Y '` �`i` �`i` ° <br />v �r �r ♦r ♦r I r rig"i�"i�"i�"i�"i�'i ��r ��'ir ��rr 1 <br />A —IV <br />\ \(�`, \'\`�\ \ ; 6 M I L VAPOR y�i ` i <br />`r''.`r'rr`r'�r`� 'r`:'rrY'r.;':::'�r y�r:''/, BARRIER r\ . <br />�. .r .r .r <br />i'`,�`%��`i`��`i`��`i`��`i`��`T���'i`��`i`���i`�� <br />r�r r <br />V-4„ <br />1 FOOTING DETAIL. <br />s2 <br />1" DEPTH X 10" RECESS <br />10" � 4" TH CONC SLAB <br />Z: W! 6x6 10/10 WWF <br />� • a <br />d d <br />r �T %, �T v . ° v �r �r �T ♦T �T � v ♦r �T �r <br />✓rrr�rr � ryr r�,rr,� e ,i �'i'r�'i'r�r'r�'i'�'i'�'i'��'i'r�'i'r�'i fir ri�i <br />�i'��'�i�rr'�i'r✓\ri'!�ri'y}�ri�'r� va ri'r�'i'r�'i'J<'i'r�'ir�'i'�'i'J�'i'r�'i'r�i'i'�'i <br />2-#5's <br />1'-4" <br />2 FOOTING DETAIL <br />S2 <br />RECESS AT ALL DOOR LOCATIONS. FOLLOW <br />MANUFACTURERS SPECIFICATIONS FOR PROPE <br />RECESS SIZE. <br />4" TH CONC SLAB <br />W/ 6x6 10/10 WWF <br />d <br />d d <br />Z d' d < <br />0Um <br />U 6 MIL VAPOR <br />i BARRIER <br />245's� 1'4" <br />e FOOTING DETAIL <br />s2 <br />4" TH CONC SLAB <br />W/ 6x6 10/10 WWF <br />I END <br />6 MIL VAPOR <br />BARRIER <br />1-#5's <br />4 FOOTING DETAIL <br />S2 <br />4" TH CONC SL <br />W/ 6x6 10/10 W <br />vE <br />1 7" <br />s2 <br />FOOTING DETAIL <br />4" TH CONC SLAB <br />i 10/10 WWF <br />OPTIONAL -. FIBERMESH CONCRETE (3000 PSI) <br />CHEMICAL SOIL TREATMENT FOR TERMITES <br />1- A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE -INSPECTION AND TREATMENT <br />CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER. OR ELECTRICAL PANEL. <br />2- CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST V-0" AWAY FROM THE BUILDING SIDE WALLS. <br />3- IRRIGATION/ SPRINKLER SYSTEM INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN V-0" OF <br />THE BUILDING SIDE WALLS. <br />4- TO PROVIDE FOR INSPECTION OF TERMITE INFESTATION, BETWEEN WALL COVERING AND FINAL EARTH GRADE SHALL NOT <br />BE LESS THAN 6 INCHES. <br />EXCEPTION - PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY TO THE FOUNDATION WALL <br />5- INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE. <br />6- SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED INCLUDING SPACED BOXED OR FORMED. <br />7- BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS. ETC.. SHALL BE MADE WITH PERMANENT <br />METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE & DEPTH THAT WILL ELIMINATE THE DISTRURBANCE OF <br />SOIL AFTER THE INITIAL TREATMENT. <br />8- MINIMUM 6-MIL. VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. <br />IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED <br />9- CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMTER MUST BE REMOVED BEFORE EXTERIOR TREATMENT. <br />10- SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN T-0" OF THE STRUCTURE SIDEWALLS, <br />11-AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING <br />AND IRRIGATION. ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED SHALL BE RETREATED. <br />12- ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT. <br />13- A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY <br />BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE " THE BUILDING HAS <br />RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE <br />WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." <br />14- AFTER ALL WORK IS COMPLETED. LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN V-0" OF THE BUILDING <br />THIS INCLUDES A-L GRADE STAKES. TUB TRAP BOXES, FORMS. SHORING, OR OTHER CELLULOSE CONTAINING MATERIAL. <br />15- NO WOOD, VEGETATION. STUMPS, CARDBOARD. TRASH. ETC.. SHALL BE BURIED WITHIN 15'-0" OF ANY BUILDING OR PROPOSED <br />BUILDING <br />DATE: MARCH 15TH 2O20 <br />SCALE: 1 /4" <br />DRAWN: J. WASILEWSKI <br />(0 <br />O <br />r <br />(V CD <br />� <br />W O (0 <br />W V) L / <br />O2 XN <br />2 <br />m <br />wLU <br />J�oU <br />Z p M u <br />J i LU <br />OfZLL00(n <br />CD�N�w <br />O � M <br />�00Z) r--U <br />(D <br />Joo_j <br />W <br />0 CO CO <br />U) <br />c' / <br />3:O(y)Lr) <br />w0JX <br />J �: LL Q <br />U)Z)0LL <br /><wwo(0 <br />�' <br />I v- 00 <br />0 Q 00 <br />L <br />QUQ��k <br />UCNWw <br />�LOUti� <br />DUPLEX RESIDENCE <br />6554 BRENTWOOD DR. <br />ZEPHYRHILLS9 FL <br />FOUNDATION <br />PLAN <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THE <br />.ATTACHED DESIGN AND FOUND IT TO BE IN <br />COMPLIANCE WITH THE STRUCTURAL <br />PROVISIONS OF THE FLORIDA BUILDING CODE <br />2020 SEVENTH EDITION <br />THE ENGINEER HAS NOT REVIEWED THE <br />PRE-ENGINEERED TRUSS MANUFATURER'S <br />LAYOUT TO DETERMINE ANY LOAD BRG. <br />CONDITION RESERVES THE RIGHT TO <br />MAKE XqY ES AFTER TRUSS LOAD <br />INFO TI SUP�tj4� ENGINEER. <br />SEAAD <br />LILY <br />No 15586 <br />• 7t <br />TATE OF [V� <br />R O �R. I•••P•.���. <br />S••••••O• <br />
The URL can be used to link to this page
Your browser does not support the video tag.