My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6581 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6581 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:29:24 AM
Creation date
2/18/2025 4:35:59 PM
Metadata
Fields
Template:
Building Plans
Street #
6581
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
6457
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br />9i <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />PANEL CENTER <br />#14 to lights & outlets <br />#12 to appliances and GFI <br />#10 to WH <br />#8 to Range <br />#6 to HVAC <br />150=2/0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />Isconnect <br />4 Bare Cu Ground <br />BONDING <br />p4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES. Typical 150-200 Amp Electrical Riser Diagram REV.03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />�IQG.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />Fktbv <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�?4 <br />FOUR-WAY SWITCH <br />�R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />r-------------------------------- ----------------------- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I-o WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE j <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE I <br />O I <br />EXHAUST FAN I <br />I <br />;Qt EXHAUST FAN/LIGHT COMBINATION I <br />I <br />® ELECTRIC DOOR OPERATOR (OPTIONAL) <br />I <br />CH CHIMES (OPTIONAL) j <br />�P PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOORBELLL------------------------------------------------------- <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />(✓ J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />SECOND FLOOR ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4'=1'-0" <br />N <br />N <br />C" <br />0 <br />W <br />� <br />= ro V M <br />'O co <br />+. <br />= a ia- <br />ro o <br />oa =s .= tv <br />3 IF .,— c <br />4 v "" 'Cr <br />3 3 ra <br />� <br />or, ? <br />D <br />C <br />ro c <br />06 u <br />M <br />N <br />0 <br />N <br />1 <br />r� <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />H <br />W <br />a <br />v EE <br />p co 8 <br />p <br />di <br />Wy <br />raLon� J <br />N'V zs A LL <br />C -j LL W <br />LL <br />,n <br />Z <br />r� LL aas a <br />19 <br />� m <br />Z <br />ILW <br />rc' MZ d <br />NLL <br />O <br />U v <br />W <br />C0 <br />M U <br />z <br />L n <br />c� <br />V I <br />I- u, <br />z M <br />CZ <br />� -J <br />LL <br />N <br />OW <br />$ <br />C N <br />,L <br />L � <br />! <br />v <br />0 <br />o <br />cd <br />Cl) <br />M <br />a <br />w <br />j <br />J <br />l.L <br />N ¢ <br />w o <br />a <br />aE <br />Co <br /><> <br />Z <br />an <br />5 <br />`n. c <br />Q1 <br />x <br />mt <br />M I <br />Z <br />m J <br />w m <br />N <br />8� <br />N <br /><�Z� <br />21 <br />e_ <br />W <br />�LL <br />o <br />0t� <br />2 4 <br />V <br />0 O <br />121) <br />>Lo <br />L <br />ai <br />LO <br />M <br />Q <br />0 <br />CL <br />L- <br />F- <br />N' <br />coqt <br />C <br />O <br />0Q <br />r.�y� <br />W Q <br />JN� <br />co <br />m <br />O <br />LLB <br />+ J <br />4-# <br />O <br />/'!1 <br />00 <br />m <br />LO <br />00 <br />CV <br />Q <br />N <br />oo n <br />ui <br />d' <br />( ` <br />t1i <br />o <br />Z <br />M <br />E T <br />y <br />v, <br />`m <br />c <br />c <br />a <br />E <br />U <br />v ui <br />q p <br />c <br />JOB <br />NO: <br />23-06141 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.