Laserfiche WebLink
MATCH LINE MATCH LINE <br />"I. ,-] I B 1 <br />{ <br />,2 <br />34 <br />I i <br />IE <br />34 <br />I� <br />i <br />€ 34 IL <br />1. <br />2-9127-2 _ `I 7-0 <br />L <br />0 1, <br />3 <br />B-912 7-212 0 9-6 <br />n � a <br />9-912 <br />rn <br />n f.V 19-912 <br />6-31 z„ i 13-4 3- 1 z 3-9 `�1: 6-1112 <br />�cn <br />n ,, 34 <br />3{ C{ { <br />I _ _ I 9 I ..- _. _ . _ .,,_ I <br />1 t <br />n N <br />f <br />{€ E E <br />E f E 1 1 f 1 <br /># t I € e I <br />n { n <br />{{ <br />_ <br />M CD <br />--------- ------ i -------- ---- <br />I 1 9391z _ ( 9347 - o <br />21 MATCH LINE I MATCH LINE <br />OWENS-CORNING (R-30) INSULATION <br />TO FULLY COVER THE FIRE <br />PROTECTION SYSTEM IN ATTIC <br />BY OTHERS <br />---------------- <br />SPRINKLER DROP PIPE TEE <br />SPRINKLER BRANCH LINE <br />SPRINKLER DROP PIPE <br />II <br />'-SPRINKLER HEAD <br />JOIST <br />FINISHED CEILING <br />OCCUPIED CONDITIONED SPACE <br />PIPING RAN IN ATTIC W/ <br />INSULATION DETAIL <br />SCALE. NOT TO SCALE <br />N <br />EXTERIOR WALL AT PORCH <br />314" CPVC PIPE AND FITTINGS <br />HEATED AREA Y4' CPVC FEMALE ADAPTER <br />ARMAFLEX ENTIRE SYS1 EM DRY PENDENT LENGTH 'A' DIMENSION <br />1 1/2' UNLESS NOTED OTHERWISE ON <br />PLAN <br />CEILING <br />® DRY PENDENT TYP ON PORCH <br />WITH SLEEVE AND SKIRT ESCUTCHEON <br />SCALE NOT TO SCALE <br />a <br />0 <br />0388 <br />0389 <br />m <br />RISER LEGEND <br />101 <br />CPVC PIPE HANGER LOCATION DETAIL <br />TABLE <br />1 <br />TABLE <br />2 <br />TABLE <br />3 <br />PIPE <br />SIZE <br />LESS THAN <br />100 psi <br />MORE THAN <br />100 psi <br />LESS THAN <br />100 psi <br />MORE THAN <br />100 psi <br />LESS THAN <br />100 psi <br />MORE THAN <br />100 psi <br />3/4" <br />6" <br />6" <br />4'-0" <br />3'-0" <br />5'-6" <br />5'-6" <br />1" <br />12" <br />9" <br />5'-0" <br />4'-0" <br />6'-0" <br />6'-0" <br />1-1 /4" <br />16" <br />12" <br />6'-0" <br />5'-0" <br />6'-6" <br />6'-6- <br />1-1/2- <br />24" <br />12" <br />7'-0" <br />7r-O" <br />7'-0" <br />7•-0" <br />2" <br />24" <br />12" <br />7'-0" <br />7'-0" <br />8'-0" <br />8'-0" <br />2-1 /2" <br />24" <br />12" <br />1 7'-0" <br />7'-0" <br />9'-0" <br />9'-0" <br />3" <br />24" <br />12" <br />7'-0" <br />7'-0" <br />10'-0" <br />10'-0" <br />TABLE 3 <br />TABLE 1 TABLE 2 <br />CPVC PIPE <br />LHANGER / BRACE <br />FINISHED CLG. <br />SPRINKLER HEAD <br />LHANGER <br />/ BRACE <br />HANGER APPLICATION <br />r <br />RESTRAINER `APPLICATION <br />1 <br />1. 6" FIRE LINE BY OTHERS <br />2 6 X 4 GRV COUPLING SFP TO START HERE <br />0 4" SPOOL PIECE <br />® 4" GRV BUTTERFLY VA W/TS <br />4" <br />GRV <br />CHECK VA. <br />61 <br />© <br />4" <br />GRV <br />RISER MANIFOLD W/TRIM <br />© <br />4" <br />GRV <br />TEE <br />® <br />6" <br />FIRE <br />LINE TO REMOTE FDC <br />RISER DETAIL <br />® 4" TO MANUAL WET STANDPIPES <br />CPVC Pt <br />HIL11 PEN <br />OR EQUAL <br />T <br />ONE HOLE STRAP <br />HANGER DETAIL #12 <br />SCALE: N.T.S. <br />z <br />N <br />SEE SHEET FP1.0 <br />FOR CONT. <br />6" FIRE LINE i-6" FDC FIRE LINE <br />B:f] <br />c!] 0389 oss8 i SPRINKLER RISER <br />! -- ----- = = BOR1 , BELL/REMOTE FDC <br />_1 <br />I 0 <br />i € <br />I I <br />4 <br />I 3 9-912 i t I� 1 3 I ; � <br />I 0-91 x j <br />I <br />Y- to I € <br />€I I 3 i12 <br />I t t 1 <br />4 1 I <br />1-0 412 4-7 I 7- 'i' 9-0 i' 11 <br />f <br />1_0 <br />cn <br />{53{5 <br />F. <br />j 4 <br />< c�0' I >_ 14" BK SUPPLY " 1 0 <br />STANDPIPE CONTROL VA. <br />Sa.FT. I0D I € € t W/TS <br />, « <br />« 41 <br />co co 1 I + <br />9-101 x 3-51 13- 2-61: 6-111 z 2-61 x 1 3- 3-51 z 10-91 x 3-31: 10-112, 12-91 z 3-6 5-6 3-612 340 3-6 61: 3-312 i9 4" M' <br />a . IXII co <br />ch n <br />Pa` # t 7 3 4 <br />3 ," E ,__«_.... .........»., ..».....,..... CC i € I E € '{ Iitl I E 1 <br />1 r� <br />t",",.,,,, ;; I ' 34/.�6-612 <br />�, i <br />I Sq.fT. <br />34{� � <br />_ . <br />1-9 <br />n o, n I _____ 01 U i <br />of <br />I IN A <br />_ I 4 3 <br />13 0 4-8 <br />I € - <br />jI I � �� # I • € <br />€ 34 <br />I O �9-91�faf 3 <br />B21 <br />1 & 2 HOUR PENETRATION SEAL <br />System No. W-J-1067 HILTI, INC. FS-ONE DETAIL IS SHOWN. AN EQUAL <br />F-Rating - 1 and 2 Hr (See Items 1 and 3) FIRE STOPPING SYSU MAY BE USED AS TANG AS <br />T-Rating - 0 Hr THE RATING OF THE FLOOR / WALL IS MAINTAINED. <br />L Rating At Ambient - Less Than 1 CFM/sq ft <br />L Rating At 400 F - 4 CFM/sq ft <br />T,,T <br />I A <br />L A <br />NOTE : Section A -A <br />1. GYPSUM BOARD WALL ASSEMBLY <br />2. THROUGH PENETRATE - ONE METAWC do CPVC PIPE INSTALLED EITHER <br />CONCENTRICALLY OR ECCENTRICALLY WITHIN FIRESTOP SYSTEM. <br />3. FILL, VOID OR CAVITY MATERIAL - SEALANT - MIN. 5/8 IN. <br />THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH BOTH <br />SURFACES OF WALL. AT THE POINT OF CONTACT LOCATION BETWEEN THE <br />THROUGH PENETRATE AND GYPSUM WALLBOARD, A MIN. 3/8" DIA. BAD OF <br />FILL MATERIAL SHALL BE APPLIED AT THE GYPSUM WALLBOARD/THROUGH <br />PENETRATE INTERFACE ON BOTH SURFACES OF WALL. SPECIFIED <br />TECHNOLOGIES. <br />FIRE SPRINKLER PLAN FIRST FLOOR AREA A <br />SCALE 1 /8"=1'-0" <br />PIPE SIZES BASED ON FOURTH FLOOR CALCULATIONS <br />SYSTEM COVERS APPROXIMATLEY 29,000 SQ.FT. PER FLOOR <br />SYM <br />CNT <br />POSITION <br />FINISH <br />TEMP <br />K <br />NPT <br />SIN <br />MFG. <br />MODEL <br />1106 <br />PEND <br />WHITE <br />155 <br />4.90 <br />1 /2" <br />TY2234 <br />TYCO <br />LFII <br />® <br />208 <br />PEND <br />WHITE <br />175 <br />4.90 <br />1 /2" <br />TY2234 <br />TYCO <br />LFII <br />48 <br />PEND <br />WHITE <br />200 <br />5.60 <br />3/4" <br />GL5635 <br />Globe <br />GL-DRY <br />1362 TOTAL SPRINKLERS THIS PROJECT <br />I Al I <br />NO SPRINKLERS REQUIRED <br />€1 <br />v <br />£ 1 <br />' I I( <br />rr I <br />_-_-_- I E <br />L� � I ( I ! <br /># <br />1 <br />4 4t <br />i I <br />s I _ I _ <br />t f 0 <br />' € L J I I I <br />0 f t # <br />i � s E f t t <br />d <br />•"Y { 4------ _3 -------- 3 --- * <br />_______ <br />I Li <br />r° <br />{ <br />------- _--------------------- ----------- <br />Os 0 <br />I iH1 ! <br />Ef----___-___________� i <br />E � E i <br />i <br />i I i i f <br />0 <br />�t 3 13 � € E <br />L------------ ....,---- _,..--------------- --._- _.i II L_..__.__,....,.-...,....«_..............,..,>...,_....{ LY i __________ E! € <br />i <br />______------ _-------------- ---------- _______ ' <br />r-- <br />� � E <br />t <br />4 <br />------------ <br />i <br />ll <br />E f„'^'.. �� EL ---- <br />£ <br />I <br />£ <br />I <br />I <br />31 <br />3-41t M <br />C1 <br />GENERAL/ OVERHEAD NOTES <br />1. <br />FIRE PROTECTION SYSTEM DESIGN, MATERIALS, INSTALLATION, AND TESTING SHALL <br />COMPLY WITH N.F.P.A. 13R (2010 ED.), AND ALL APPLICABLE STATE AND LOCAL <br />CODES. <br />2. <br />SPRINKLER HEADS ARE NOT REQUIRED TO BE CENTERED IN ACOUSTICAL CEILING <br />TI LE. <br />3. <br />ANY AND ALL PENETRATIONS IN FIRE/SMOKE WALLS SHALL BE FIRE AND SMOKE <br />STOPPED WITH A LISTED ASSEMBLY. SEE DETAIL THIS PAGE <br />4. <br />ALL PRODUCTS, PIPING, AND EQUIPMENT USED FOR FIRE PROTECTION WORK <br />SHOWN <br />ON THESE DRAWINGS SHALL BE U.L. LISTED AND BEAR SUCH MARKINGS. SEE <br />MATERIAL SUBMITTAL DATA FOR PRODUCTS TO BE USED. <br />5. <br />ANY SPRINKLER HEADS INSTALLED IN HARD CEILINGS SHALL BE PROTECTED BY A <br />REMOVABLE HEAD COVER TO ENSURE HEAD IS NOT DAMAGED DURING CEILING <br />FINISHING PROCESS. <br />6. <br />HANGER SPACING AND INSTALLATION SHALL CONFORM WITH N.F.P.A. 13 (2010 ED). <br />7. <br />ALL THREAD ROD SHALL BE ZINC PLATED. <br />u� <br />1� <br />8. <br />MATERIALS OF INTERNATIONAL ORIGIN MAY BE USED. <br />v <br />9. <br />NO PAINTING, WIRING, OR PROVIDING OF FIRE EXTINGUISHERS IS REQUIRED OF THE <br />CONTRACTOR. <br />10. <br />ALL OUTLETS SHALL BE SHOP WELDED. TAPE AND PIPE DOPE SHALL BE USED AT <br />ALL <br />WELDED OUTLETS. <br />w <br />W <br />11. <br />PIPE JOINT COMPOUND SHALL BE USED AT ALL THREADED CONNECTIONS. <br />12. <br />ALL LENGTHS ARE CENTER TO CENTER U.N.O. <br />1� <br />DESIGN CRITERIA <br />1. <br />PROTECTION AREAS (52,000 S.F. MAX. PER SYSTEM • <br />3rd <br />LEVEL RESIDENTIAL LIVING AREAS - PER N.F.P.A. 13R. <br />V L <br />2. <br />BUILDING CONSTRUCTION: CEMENT SLAB FLOOR ASSEMBLY., WALL TO BE SHEET <br />O <br />ROCK <br />WITH WOOD STUDS WALLS. <br />Z <br />3. <br />ALL SIDEWALL SPRINKLER HEADS TO BE 4" TO 6" BELOW DECK / CEILING U.N.O. <br />13R <br />SYSTEM IN ALL APARTMENT BUILDING TYPICAL U.N.O. <br />10. <br />SYSTEM DESIGN PER REQUIREMENTS OF N.F.P.A. 13R 2010 EDITION FOR A <br />RESIDENTIAL DWELLING 4 STORIES OR LESS IN HEIGHT USING RESIDENTIAL <br />SPRINKLERS ACCORDING TO MANUFACTURER'S LISTING. <br />10. <br />WORK & MATERIALS TO BE IN ACCORDANCE W/ N.F.P.A. 13R. <br />11. <br />PIPE & FITTINGS TO BE C.P.V.C., U.N.O. <br />12. <br />WIRING & CENTRAL STATION MONITORING TO BE DONE BY OTHERS. <br />14. <br />DESIGN AREA IS UP TO (4) HEADS IN UNIT W/ 18' X 18' MAX. SPACING UNLESS <br />NOTED OTHERWISE. SEE SPECIAL NOTES ON EACH BUILDING FOR SPECIAL <br />SPRINKLER HEAD SPACING INFORMATION. <br />15. <br />THE FOLLOWING AREAS ARE NOT TO HAVE SPRINKLER HEADS ACCORDING TO <br />N.F.P.A. 13R - 2010 EDITION <br />A. <br />BATHROOMS NOT EXCEEDING 55 SQ FT. W/ NONCOMBUSTIBLE PLUMBING <br />FIXTURES. <br />B. <br />LINEN CLOSETS, CLOTHES CLOSETS & PANTRIES NOT EXCEEDING 24' SQ. FT. & <br />THE <br />LEAST DIMENSION NOT EXCEEDING 3'-0", CONSTRUCTED OF NON COMBUSTIBLE OR <br />LIMITED COMBUSTIBLE MATERIAL. <br />B. <br />OPEN ATTACHED ENTRIES, CARPORTS, AND SIMILAR STRUCTURES. <br />D. <br />ATTICS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED <br />OR <br />INTENDED FOR LIVING PURPOSES OR STORAGE. <br />E. <br />OPEN BREEZEWAYS, CORRIDORS, STAIRS THAT ARE OPEN AND ATTACHED SEE <br />N.F.P.A.13R 2010. <br />S� <br />o: a <br />�r • <br />j' rau o 40 <br />CQ <br />F� n <br />�.. co <br />h+i M[TTuJ] <br />I <br />• In x c\2 <br />E4 x a <br />Q; w CD <br />O 0 <br />1� <br />� <br />w <br />0 <br />� �^ <br />90.4 <br />w Q <br />O <br />�1 <br />04 <br />O <br />w�P <br />0 <br />E � <br />1®b MCQ <br />o�Ako <br />® P4to <br />t-zWo <br />® _ Z Pq �. <br />P. <br />oa <br />U� <br />o � <br />N U <br />CQ <br />W <br />J <br />Q <br />Z <br />O <br />w <br />0-0 <br />a. <br />F <br />Q <br />d <br /><n <br />a <br />W <br />z <br />0 <br />5 <br />w <br />w <br />Ca <br />0 <br />0 <br />z <br />w <br />a <br />a <br />V) <br />H <br />O <br />z <br />O <br />N <br />1- <br />CL <br />w <br />Q <br />O O <br />fN <br />W <br />0 <br />o <br />Z cn <br />g� <br />Y <br />z <br /><n <br />cn <br />o <br />J <br />a <br />z <br />a <br />C! <br />I <br />I <br />N <br />SCALE: AS NOTED <br />JOB NUMBER. <br />DATE- 04.10.16 <br />SHEET NO. <br />FP1 •A <br />