Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />UNDERGROUND IDis <br />SERVICE BY POWER CO.---, <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />150A/200A INDOOR <br />PANEL CENTER <br />14 to lights & outlets <br />12 to appliances and GFI <br />'0 to WH <br />B to Range <br />B to HVAC <br />150=2/0 <br />200=410 in 2" Conduit <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV.03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits In all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />Lph <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />� 3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />FP <br />PUSH BUTTON SWITCH (OPTIONAL) <br />1-0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />Ja <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />11�­ — n­^e% <br />SCALE: NTS <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4"=1'-0" <br />co <br />O <br />C" <br />os v <br />C2 W <br />O � o <br />Z <br />C2. o <br />Ccc_;,N <br />-� <br />-- -o == x <br />�LL� <br />l0 O w <br />O O C c9 <br />Q r N ]C <br />CL <br />61 C <br />E c <br />0 <br />tv u HE <br />� 3 <br />ee� ai d .a <br />c � <br />Q �J <br />C: <br />ch <br />N <br />O <br />N <br />ww <br />. <br />- <br />rf <br />r Lh <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />g <br />p E N <br />t_ <br />V <br />N N <br />O <br />N —t <br />�Mv LL <br />W <br />a. a <br />d <br />J_LLLL <br />Z <br />Z <br />L �0 <br />c <br />Ili.' <br />cb t0 t o to a <br />�T Z <br />W <br />Z <br />ILW <br />00 <br />Lo Cl) Z y <br />Z <br />Z <br />N <br />O V ❑❑❑ <br />W <br />0 V <br />z <br />S <br />Z o d <br />¢ v <br />n— Y1 <br />Z v <br />U' <br />�-J <br />0) <br />s <br />LL <br />•� <br />�LU <br />C <br />Ow <br />V) <br />c d <br />® <br />w � <br />~ <br />Y* <br />Q <br />sr <br />o <br />cD <br />a <br />M <br />O <br />Z <br />o E <br />V <br />z <br />nn <br />CL <br />E` <br />&Z <br />Zo <br />H <br />�g <br />�a <br />tty <br />ru <br />•� <br />(VYJ <br />Z <br />8 3 <br />0 <br />ZO <br />° <br />.anz <br />=3 <br />v <br />zl< <br />0 <br />`O <br />= <br />L <br />rn <br />Q <br />0 <br />CL <br />0 <br />d. . <br />0 <br />O <br />vJ <br />J <br />com <br />U') <br />r <br />Q <br />� <br />O <br />t'L M <br />(� <br />I <br />U NO <br />T <br />m N <br />L0 <br />a) <br />Q <br />LO 0 <br />i1i <br />cs7 <br />c <br />Z <br />m <br />E O <br />(n <br />m <br />a <br />EE <br />U � <br />v <br />Q p <br />c <br />JOB <br />NO: <br />23-04908 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />