i-L <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance With the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided With a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />IS <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />'4 � <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�fB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />10 <br />ELECTRIC METER <br />a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ql�� 0 <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />��� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(9D <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />4 to lights & outlets <br />2 to appliances and GFI <br />3 to WH <br />to Range <br />to HVAC <br />MO -. <br />r2oo= <br />50=2/04/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND IDis <br />SERVICE BY POWER CO.� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />4 Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV.03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />SMOKE DETECTORS <br />SMOKE DETECTORS SHALL BE IN ALL SLEEPING <br />AREAS, SHALL BE INTERCONNECTED, SHALL BE WITHIN <br />1' TO 3' OF PEAK, AND SHALL BE 3' FROM THE <br />SUPPLY OR AIR STREAM, AND EQUIPPED WITH <br />BATTERY BACK-UP. ALL SMOKE DETECTORS TO BE <br />ARC -FAULT PROTECTED. <br />FAIR HOUSING ACT REQUIREMENTS: <br />OPERABLE PARTS OF THE CONTROLS FOR LIGHT SWITCHES, ELECTRICAL <br />OUTLETS, THERMOSTATS AND OTHER ENVIROMENTAL CONTROLS MUST BE <br />LOCATED NO HIGHER THAN 48", AND NO LOWER THAN 15", ABOVE THE FLOOR. <br />IF THE REACH IS OVER AN OBSTRUCTION (FOR EXAMPLE, AN OVERHANGING <br />SHELF) BETWEEN 20 AND 25 INCHES IN DEPTH, THE MAXIMUM HEIGHT IS <br />REDUCED TO 44" FOR FORWARD APPROACH; OR 46" FOR SIDE APPROACH <br />PROVIDED THE OBSTRUCTION (FOR EAXMPLE, A KITCHEN BASE CABINET) IS <br />NOT MORE THAN 24 " IN DEPTH. OBSTRUCTIONS SHOULD NOT EXTEND MORE <br />THAN 25" FROM THE WALL BENEATH A CONTROL. <br />COMP. <br />DISC. <br />WP <br />GFI <br />9 <br />211 <br />tI,�TR <br />V1� <br />I <br />oN () <br />�C N <br />ail <br />3' <br />3It 41, <br />3 411 <br />M <br />AIN <br />PLUMBING RISER_ <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />VERIFYTER <br />VERITY N WITH <br />UNIT 1397 ELECTRICAL PLAN <br />LOCATION WITH <br />BUILDER <br />SCALE: 1 /4"=V-0" <br />C <br />0 <br />Cell, <br />(r l <br />O <br />L. i <br />` <br />^ <br />V <br />� " <br />m t� <br />C. =' C <br />u <br />i- a <br />O O <br />O U <br />/ <br />¢tea �u� <br />N <br />CV <br />0 <br />N <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />a <br />v E <br />0 <br />8 <br />k°: V <br />o <br />co <br />di <br />rn�I-- <br />2S u7 <br />x <br />Q <br />Oj t C # <br />cc: 2 LL W <br />LL SSS <br />a, <br />w <br />Z <br />;7)LL <br />M m o 5 <br />N (D_5z <br />? O <br />WU) <br />m w <br />Z <br />'^ IL <br />, . <br />- MZ <br />Z <br />J <br />N dU v L) <br />W <br />El <br />a <br />M <br />� 1 <br />�/ <br />/zM <br />/^^ O <br />) <br />V O <br />V <br />V� <br />W � <br />o A <br />� <br />0 <br />w s <br />N <br />� Y <br />�N <br />f6 <br />U g <br />U o' <br />C U) <br />Q <br />I'd <br />14 <br />C" <br />o <br />w <br />M <br />o3 <br />Z <br />Z <br />J <br />,l <br />U <br />¢ <br />z o <br />� <br />> <br />¢o <br />wo <br />i <br />z® <br />oa <br />f— to <br />�o <br />oU <br />0, <br />Z <br />E <br />N <br />Qi <br />R ~ <br />0 <br />1... <br />p <br />C13 <br />' � <br />¢� <br />y 0 <br />mg <br />O <br />Zp <br />Z <br />Cn <br />N <br />< W <br />Q <br />o< <br />ZZ <br />g� <br />a <br />W <br />d <br />a 3 <br />v <br />� <br />2 W <br />�w <br />zZ <br />M <br />0o <br />Jz <br />aY <br />�o <br />a <br />c ^ <br />•y' <br />co <br />_ <br />ui <br />rn <br />� <br />O <br />O <br />— <br />> <br />O <br />L0 <br />T <br />O <br />co O <br />Q <br />M <br />r <br />r- <br />CY <br />CV <br />60 <br />Cn ° <br />m <br />r <br />O <br />T <br />Q <br />_ <br />}� <br />N <br />.Q <br />h <br />CN <br />O <br />O <br />cfl <br />N <br />T <br />LO <br />L J <br />T <br />w <br />a <br />m <br />� T <br />ri <br />Z <br />Z <br />c <br />E <br />`m <br />c <br />a <br />U -j <br />Q p <br />JOB <br />NO: 22-03326-03321 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7 <br />