Laserfiche WebLink
i"v <br />ROOF SHINGLES OVER ROOF SHINGLES OVER <br />12 15# ROOFING FELT 12 15# ROOFING FELT <br />SEE ROOF SEE ROOF <br />PRE-ENGINEERED ROOF PRE-ENGINEERED ROOF <br />PLAN TRUSSES AT TYP. 24" O.C. PLAN TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO OF TRUSS - REFER TO <br />nnon STRUCTURAL. z STRUCTURAL. <br />016 TOP OF C.M.U. TOP OF C.M.U. <br />(REFER TO ELEV.) _ (REFER TO ELEV.) <br />INSULATION PER <br />COMMUNITY SPEC. SEE 2x6 ALUM WRAPPED FASCIA <br />SEE ENERGY CALCS. ELEV. SEE BD. w/ALUM DRIP EDGE. <br />1/2" (MIN.) CLG. BD. 1/2" (MIN,) ------ SOFFIT PER SPECS <br />2x6 ALUM WRAPPED FASCIA CLG. BD. <br />ix PT DRAPE BLKG BD. w/ALUM DRIP EDGE. (e" TYPE'X' GYP. BD. SEE STRUCTURAL <br />ABOVE WINDOWS 1/2" SOFFIT PER SPECS TO BE PROVIDED PLAN <br />G.W.B. WHEN LIVING SPACE <br />SEE STRUCTURAL IS ABOVE GARAGE) <br />WINDOW PER PLAN PLAN 8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />GYP.BD. <br />WINDOW SILL <br />1/2" GYP. BD. OVER RADIANT PRECAST WIN. SILL <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO 1x2 PT. <br />FURRING (chi 24" O.C. SLOPE GRADE AWAY EXPANSION JOINT <br />FROM HOUSE DRIVEWAY PER COMMUNITY <br />BASE BOARD GARAGE SLAB, 4„twim—­ <br />SPECS <br />SEE STRUCTURAL <br />ob <br />0'-0" PLANS � l. 0'-0" <br />FIN. FL. mm.. E E FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP_ . _1-STORY WALL WINDOW <br />SCALE: 1/2" = V-0" - <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4— <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />j" GYPSUM <br />BOARD <br />ELECTRIC METER <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD — <br />STUCCO <br />FINISH <br />EXTERIOR— <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />GRADE <br />GYPSUM <br />GYPSUM BOARD <br />BOARD g <br />3 1/2" a. GYPSUM — <br />BOARD <br />GARAGE a <br />NICHE FOR — <br />ELECTRICAL <br />PANEL & <br />WIRING <br />N <br />ELECTRICAL M <br />PANEL ELECTRICAL — <br />PANEL <br />N <br />ao `O EXTERIOR—N <br />CMU BLOCK <br />WALL <br />CONCRETE "' CONCRETE — <br />CURB REFER CURB REFER <br />TO PLANS TO PLANS <br />CONCRETE <br />s p SLAB ON <br />i GRADE AT <br />GARAGE <br />FLOOR <br />01 <br />_ • <br />_ --FOUNDATION <br />M PER STRUCTURAL DRAWINGS <br />WALL SECTION GARAGE DOOR <br />SCALE: 1/2" = 1'-0" -- — - --- <br />01 <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" = 1'-O" <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />DEC 21 2020 <br />• NO 77824 <br />ct <br />s*• /1� <br />%1 STATE OF <br />1001 <br />rt�rr <br />IY <br />W <br />}2Ir <br />LU ?O OH <br />} <br />WC¢O <br />>cLLJ <br />WpF- <br />u)UWw <br />Lu <br />�F->g <br />5cc�Ir <br />Y O I— z <br />,S LL 0 0 U) <br />zQz4zLu <br />�z_ <br />�JQ2—� <br />uu a = a- <br />�UpOU <br />=2zLLU) <br />�I—QZD <br />cz <br />�- <br />cz CZ <br />cz <br />n <br />0 <br />Q <br />0 <br />0 <br />U <br />Z <br />0 <br />ma <br />I•�I <br />Im <br />Lo <br />0 <br />�w <br />[L �n <br />0 <br />z <br />0 <br />O <br />G <br />O <br />o <br />�Z <br />aaaaa <br />COMMUNITY; <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6101 <br />RELEASED: 1219/20 <br />SHEET <br />A5.2 <br />