vl <br />c <br />0 <br />c <br />0 <br />I <br />L0 <br />0 <br />q <br />Go <br />4 <br />N <br />I <br />A <br />4- <br />v <br />C <br />Q <br />to <br />O <br />I <br />0 <br />0 <br />VERIFY METER <br />LOCATIONS WITH <br />BUILDER <br />PROVIDE 12" MIN. <br />VERT. SEPARATION <br />FROM ANY / ALL <br />UNDERGROUND <br />UTIL. <br />WALL LEGEND <br />8'-8" TOP OF MASONRY WALL <br />(GARAGE) <br />9'-4" TOP OF MASONRY WALL <br />_11 18'-8" TOP OF MASONRY WALL <br />18'-8" TOP OF MASONRY WALL <br />• •' ONLY. • FIRST <br />FLOOR BELOW. <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />-9'-4" TOP OF MASONRY WALL <br />(LANAI) , W/ SHAFT LINER ABOVE <br />TO BOTTOM SIDE OF DECKING <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />-18'-8" TOP OF MASONRY WALL, W/ <br />SHAFT LINER ABOVE TO BOTTOM <br />SIDE OF DECKING <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />-20'-0" TOP OF MASONRY WALL, W/ <br />SHAFT LINER ABOVE TO BOTTOM <br />SIDE OF DECKING <br />TYP. INTERIOR WALL <br />BEARING WALL <br />V 1 1 1 I 1L.1I11 \L r�V <br />WP PER SPECS <br />(1787) <br />V V F <br />(1666) <br />�� rtH 5rtc;5 �• <br />1st FLR ELECTRICAL PLAN <br />SCALE: Ya"=1'-0" <br />P <br />Riser Diagram <br />4 UNIT BUILDING <br />2/0 CU GEC <br />CONNECTED <br />TO LIFER AND <br />(2) RODS <br />1 <br />1 <br />I <br />I <br />I <br />/ <br />600 AMP <br />SERVICE <br />00 <br />150 AMP <br />00 <br />150 AMP <br />150 AMP <br />150 AMP <br />(2) 3" SCH 80 PVC CONDUITS <br />WITH (2) 500 MCM XHHW AL <br />AND (1) 350 MCM XHHW AL <br />EACH CONDUIT <br />(4) METERS PER BANK <br />(1) METER BANKS PER <br />4-UNIT BLDG. <br />(1) 1 ? SCH 80 PVC CONDUIT <br />WITH (2) 2/0 XHHW AL <br />(1) #1 XHHW AL <br />(1) #4 XHHW AL <br />TYPICAL ALL UNITS <br />NOTE: <br />• ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH <br />APPLICABLE PROVISIONS OF THE NFPA 70 - 17, LOCAL CODES AND <br />THE LOCAL POWER CO. <br />• INSTALL 2" CONDUIT TO METER CAN <br />• INSTALL A MAIN 150 AMP BREAKER IN PANEL <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />Lph <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />�3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />�R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />P� <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />R9 <br />ELECTRIC METER <br />Ja <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />e+Pi <br />CV <br />C%j <br />C" <br />1= <br />0 <br />® <br />-o <br />® <br />d� <br />O LN <br />LLJ <br />tom. <br />a <br />✓ C LL d <br />N y O fp <br />m <br />G <br />d f0i � Q <br />� � m <br />W.t <br />�. w m <br />CP m <br />w a -0 <br />5 <br />a <br />Q, w <br />w <br />N <br />N <br />N <br />N <br />N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />a <br />H <br />Q <br />o c8. <br />to C)CM <br />0 <br />N <br />a iK <br />I• <br />Q <br />M CD <br />V 2s LL <br />C <br />-j 2 W <br />to LL LL S a. <br />Z <br />_ o <br />E <br />@ 9 O <br />r°�T co9 <br />Z <br />ILW <br />N O Z Q <br />Z <br />N O U U <br />0 <br />0 M !!2 <br />Z gN Cl) <br />Z aS <br />Z o <br />v <br />J <br />QW <br />V) <br />z <br />GN <br />N LL w g <br />o IS <br />• <br />U <br />O^ <br />t/ / <br />w s <br />L� N <br />W J <br />t <br />U <br />c `� 0 <br />• <br />co <br />w <br />Z <br />01 <br />0 � <br />QE <br />o <br />_® <br />ca <br />I"- <br />K a <br />� U <br />�U <br />oQ <br />Z <br />o t <br />N <br />T <br />a� <br />g`; <br />wZ <br />¢ <br />to <br />NC <br />ao <br />IZ <br />y <br />m� <br />a <br />O¢ <br />Z <br />C <br />C J <br />wo <br />�b <br />>� <br />< <br />3i <br />8 <br />Z <br />W <br />�w <br />nj <br />o <br />CO <br />Ala <br />a <br />03 <br />C <br />CN <br />8 <br />rn <br />a <br />0 <br />o <br />i <br />J <br />LM0 <br />n <br />(II <br />-p <br />OQ <br />O^O <br />C <br />0 <br />Ta.1 <br />T <br />Y <br />C1 <br />(� m <br />n <br />O <br />� <br />CL <br />Q <br />04 <br />~ <br />CM <br />00 <br />o <br />0 <br />.fl <br />LO <br />a) <br />c0 N <br />M <br />O <br />oo j <br />U-5 <br />ui <br />(0 <br />E_LOr <br />to N <br />o <br />Z <br />Z <br />E O <br />Iu <br />cc <br />cc <br />E <br />a <br />0 _j <br />a o <br />JOB <br />NO: 22-12488-12485 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />14 <br />