Laserfiche WebLink
J <br />FOR UNDERLAYMENT <br />REQUIREMENTS SEE R905.1.1 <br />2x #2 SPF STUDS <br />@16" O.C. W/ (2) <br />16d TOENAILS T & B <br />V <br />2x BLOCKING HORIZONTALLY@ <br />INTERVALS NOT EXCEEDING <br />10'-0" (R302.11) <br />PRE ENGINEERED WOOD <br />1/2" GYP. WB (MIN.) @ GARAGE SIDE IF <br />z <br />TRUSS @ 24" O.C. U.N.O. <br />APPLICABLE. <br />d <br />ROOF FLASHING AND ROOF FLASHING <br />COMPONENTS TO BE IN ACCORDANCE <br />HURRICANE ANCHOR @ EACH <br />2x P.T. PLATE <br />1/4" DIA. X 31/4" TAPCONS @ 24" O/C & <br />6 <br />W/ R903.2, FLORIDA BUILDING CODE <br />TRUSS (SEE UPLIFT SCHED . W/ <br />( ) <br />@ 6 MAX FROM END OF 2 x PLATE <br />7TH EDITION (2020) RESIDENTIAL <br />METAL PL. UNDER EA. TRUSS <br />(2) #5 CONT. ON 3" <br />6 x 6 W1.4 x W1.4 <br />N <br />MOISTURE BARRIER <br />CHAIRS (TYP.) <br />WWF OR FIBERMESH <br />470 <br />SHINGLE ROOF, SHINGLES TO <br />, o <br />e <br />BE IN ACCORDANCE w/ ASTM <br />. ' p <br />D7158-CLASS G or H, or ASTM <br />- <br />' q <br />D3161-CLASS F, IN <br />12 <br />ACCORDANCE w/ TABLE- <br />(TYP.) <br />R905.2.6.1, FLORIDA BUILDING <br />VARIES <br />1 <br />CODE 7TH EDITION (2020) <br />RESIDENTIAL <br />ROOF SHEATHING - SEE <br />INSULATION LE <br />SCHEDULE - [RSH] - ON <br />FRAMING SHEET FOR <br />TYPICAL INTERIOR BEARING <br />SHEATHING AND FASTENERS <br />ELEV. VARIES I WALL w/ OUT UPLIFT GG <br />5/8" OR 1/2" HIGH <br />ALUMINUM DRIP <br />STRENGTH CEILING <br />BOARD PER CODE (OR 5/8" <br />GYP. TYPE "X" @ GARAGE <br />EDGE <br />ALUMINUM FASCIA <br />W/A HABITABLE ROOM <br />12" N.O. 2x SUB FASCIA <br />ABOVE) W/DRYWALL <br />EE STRUCTURAL <br />SCREWS @ 7" O.C. <br />SOFFIT SHEET SS <br />CEILING & 8" O.C. WALLS <br />8"x8"X16" KNOCK -OUT <br />INSULATION PER <br />BLOCK W/ 1#5 CONT. <br />CHART ON FLOOR <br />FILLED SOLID W/GROUT <br />PLAN <br />1x2 P.T. HORIZONTAL <br />NAILER <br />8" C.M.U. TYPICAL <br />STD. 90-HOOK (SEE DETAIL) <br />TYPE "S" MORTAR <br />ARCHITECTURAL <br />FINISH <br />1x2 PT WD FURRING @ 24" O.C. <br />1/2" GYPSUM WALLBOARD <br />U.N.O. <br />(1) #5 VERT. IN FILL <br />CELLS (SEE <br />FOUNDATION PLAN <br />FOR LOCATIONS) <br />1x4 P.T. BASE NAILER <br />4"x4" INSPECTION <br />31/4" BASEBOARD <br />PORT AT EACH <br />FILLED CELL TYPICAL <br />MIN. 2500 PSI CONC. SLAB <br />ch AT GARAGE CONTRACTOR <br />MIN PSI MAY VARY PER <br />TO CUT BLOCK OR POUR <br />MUNICIPALITY. <br />CURB DUE TO SLOPE <br />CONCRETE SLAB W/ 6X6 <br />a NOTE:EXTEND <br />W1.4XW1.4 WWF OR <br />DECO FINISH 4" to 6" <br />^FIBERMESH" <br />BELOW GRADE <br />S <br />s <br />co <br />6 MIL VAPOR <br />BARRIER <br />COMP. SOIL. ° <br />(COMPACTED TO 95% — — — <br />MODIFIED PROCTOR — <br />ASTM D1557) <br />3" MIN. CLR. <br />ON #5 REBAR CONT._/1'-4" (1 STORY) <br />OCHAIRS TYP. <br />STD. 90 NOOK (SEE <br />4„ V-8(2 STORY) <br />U.N.O. <br />DETAIL" ) <br />TYPICAL WALL SECTION <br />rA <br />SCALE: 3/4" = 1'-0" <br />S3 <br />OPT: DEPRESS SLAB 5Y" <br />DEEP AND 6" BEYOND -. <br />DOOR TO RECEIVE <br />PAVERS / DRIVEWAY <br />CONCRETE SLAB <br />PAVERS--, <br />BLOCK WALL BEYOND <br />Ill <br />14'—]�O.H.D. RECESS z �� <br />SEE A/S3 OR J/S6 —`I I <br />FOR REINF. INFO. I I I I l r <br />3" MIN. CLEARANCE <br />1'4" (1 STORY) / V-8" (1 STORY w/ DEPRESSED SLAB OPT.) <br />1' 8" (2 STOR)') <br />GARAGE DOOR SLAB RECESS J.1 <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />SEE TYP. WALL SECTION <br />LOAD BEARING OR -- <br />EXTERIOR WALL <br />SEE CC/S3 OR —� <br />G/S3 FOR ANCHOR <br />BOLT INFO. <br />(IF NO UP LIFT ON <br />WALL SEE GG/S3) <br />*SIMPSON SP1 <br />SCALE:3/4"=1'-0" S3 <br />V' 'V ' <br />I I I I I I I I <br />I I I I I I I I <br />I I I I I I I I <br />5/8"OR 1/2" HIGH STRENGTH TRUSS BOTTOM CHORD OR 2x4 #2 SPF 5/8"OR 1/2"HIGH STRENGTH TRUSS BOTTOM CHORD OR 2x4 #2 SPF <br />(U.N.O.) (OR %" GYP. TYPE "X" @ BLOCKING @ 12" O.C. w/ (2)12d TOE NAILS s „ BLOCKING @ 12" O.C. w/ (2)12d TOE NAILS <br />GARAGE W/A HABITABLE ROOM <br />GARAGE W/A HABITABLE ROOM EACH END (WHEN PARALLEL) .) (OR „ GYP. TYPE „ X @ EACH END (WHEN PARALLEL) <br />ABOVE) SEE UPLIFT SCHEDULE FOR UPLIFT GARAGEABOVE) SEE UPLIFT SCHEDULE FOR UPLIFT <br />S.P.F. DOUBLE CONNECTIONS. PROVIDE (1) SIMPSON SP1 w/ CONNECTIONS. PROVIDE (1) SIMPSON SP1 w/ <br />8"x8"x16" NOMINAL BLOCK WITH TOP PLATE (10)10d NAILS WHEN TRUSS ALIGNED WITH S.P.F. DOUBLE (10)10d NAILS WHEN TRUSS ALIGNED WITH <br />3/8" MORTAR BETWEEN COURSES SIMPSON SP2 w/ STUD BELOW TOP PLATE STUD BELOW <br />(12)10d NAILS 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. SIMPSON SP2 w/ 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. <br />1/2" CDX PLYWOOD OR 7/16" O.S.B. (12)10d NAILS U.N.O. <br />SHEATHING REQ'D. FOR ALL 1) ROW 2x BLOCKING @ MID HGT. FOR WALL 5/8" x 10" "J" BOLT @ 24" O.C. W/ 1) ROW 2x BLOCKING @ MID HGT. FOR <br />EXTERIOR OR SHEAR WALLS AS HGT. < 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS 2"x3/16" PLATE WASHER (TYP.) WALL HGT. < 8'1 (2) ROWS 2x BLOCKING <br />INDICATED ON THE PLAN. ATTACH FOR WALL HGT. > 8'-6". (ALT: 1/2"x12" TITEN HD @ 24" @ 3rd PTS FOR WALL HGT. > 8'-6". <br />SHEATHING W/ 8d COMMON NAILS @ NSULATION PER CHART ON FLOOR PLAN O.C. OR 5/8"x10' WEDGE ANCHOR NSULATION PER CHART ON FLOOR PLAN <br />3/8" MORTAR BETWEEN 4" O.C. @ BOUNDARIES, 6" O.C. @ @ 24" O.C.) <br />SLAB & BLOCK EDGES, AND @ 12" O.C. @ FIELD "SIMILAR AT FOUNDATION ONLY" <br />= 5/8"° x 10" "J" BOLT @ 24" O.C. W/ IMPSON SP1 w/ (10)10d NAILS IF NOTED, THIS REFERS TO THE SIMPSON SP1 w/ (10)10d NAILS <br />2"°x3/16" PLATE WASHER (TYP.) STEP, SIZE OF FOUNDATION AND <br />ELEV. 0'-0" (ALT: 1/2"x12" TITEN HD @ 24" O.C. 2x P.T. BOTTOM PLATE REINFORCEMENT AND WILL NOT 2x P.T. BOTTOM PLATE <br />A.F.F. OR 5/8"x10' WEDGE ANCHOR @ 24" INCLUDE THE WALL <br />O.C.) 2" x 6 W1.4 x W1.4 ATTACHMENTS / 2" 6 x 6 W1.4 x W1.4 <br />O WWF OR FIBERMESH / 1 WWF OR FIBERMESH <br />„ z 31/2" MIN. 31/2" MIN. <br />ELEV. 4-3 1/2" I <br />2x4 CONT. - - A.F,F. 0 • p / p <br />v _ 1 7iT <br />e I p p��(i41/2"mn.E) ° —31/2"(min.)-4" <br />00 <br />GARAGE DEPTH VARIES 31/2"(min. - 4" — 31/2"(min. - 4" - — - <br />- _ — <br />II <br />GARAGE SLAB AT STEP <br />SCALE: 3/4"=V-0" <br />2x S.P.F. STUDS @ 16" O.C. <br />2x STUD <br />8" C.M.U. <br />I I 1"x P.T. STUD <br />#5 VERT. IN FILLED CELL <br />N I <br />I I <br />I <br />I I <br />w/ (10)10d NAILS <br />TYP. I 2x P.T. PLATE <br />ASSUMED FINISHED <br />GRADE <br />MONO OR STEMWALL z <br />FOOTING MONO SHOWN00 <br />- <br />FOR CLARITY <br />NOTE: <br />r - - - <br />CN <br />*FOR BEARING WALL - -_ <br />W/ UPLIFT ONLY <br />FRAME WALL TO C.M.U. WALL CONNECTION <br />rD� <br />SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" S3 <br />SLAB INFORMATION. <br />11 6x6W1.4xW1.4 <br />31/2" WWF OR FIBERMESH <br />min. 4 <br />A. <br />A GRADE <br />_ qf�"";'#5 REBAR w/ OPT. <br />— I I -SCREEN ENCLOSURE <br />MIN. <br />TYPICAL THICKENED SLAB EDGE LE <br />SCALE:3/4"=V-0" S3 <br />EXPANSION JOINT <br />• • <br />I <br />I �l <br />SEE A/S3 OR J/S6 ` -1 Ir <br />I I II I I I I I <br />FOR REINF. INFO. 3" MIN. CLEARANCE <br />1'4" (1 STORY) <br />1'-8" (2 STORY) <br />GARAGE DOOR SLAB RECESS ri <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. 1, S3 <br />ADDITIONAL INFORMATION. <br />(2) #5 CONT. 4" 1'-4" 8" (2) #5 CONT. 4- -4 8"' <br />U.N.O. MIN. U.N.O. I I . <br />TYPICAL BEARING WALL STEP SHEARWALL C TYPICAL BEARING WALL @ STEP IIII'CC <br />"SHEAR WALL" SCALE: 3/4"=V-0" S3 SCALE: 3/4"=1'-0" S3 <br />COO SEGV���� <br />1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING <br />?Gs 1 <br />NAILED W/ 8d COMMON NAILS @ 4" O/C <br />BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. <br />SHEAR WALL REQUIRES 2x BLOCKING SEAMS. <br />@ <br />2x STUDS @ 16" O/C <br />\ �s <br />Ica �NUGU <br />INSULATION PER FBC AND ENERGY <br />�/ <br />2x BLOCKING HORIZONTALLY@ <br />FORM SUBMITTED WITH PERMIT <br />/' <br />\ <br />INTERVALS NOT EXCEEDING <br />(2) ROWS OF 2x BLOCKING @ THIRD POINTS <br />APPLICATION <br />NOTE: <br />10'-0" (R302.11) <br />SEE SECTION C/S3 FOR <br />7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 <br />ADDITIONAL INFORMATION <br />LAYERS W/ TOTAL THICKNESS 7/8" OVER <br />1/2" GYP. WB (MIN.) @ GARAGE <br />„o , „ , „ „" <br />5/8 x 10' J' BOLT @ 24 0/C W/ 2 X 3/16' <br />METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. <br />CONTINUOUS TO FOOTER BELOW 90 HOOK DETAIL <br />SIMPSON SP1 w/ (10) <br />SIDE IF APPLICABLE. <br />PLATE WASHER TYPICAL <br />3RD LAYER 1/8"THICK. <br />K.O. BLOCK <br />10d NAILS <br />5/8"DIA. EXPANSION BOLT @24 " <br />MIN. 2500 PSI CONCRETE SLAB W/ <br />SIMPSON SP1 w/ (10)10d NAILS @ EA. STUD <br />2x P.T. PLATE <br />O.C. W/ 7" EMBEDMENT (MIN. SHEAR <br />6 x 6 W1.4 x W1.4 WWF OR <br />2X PT PLATE <br />20" MIN. LAP [24" MIN. LAP] <br />#5 REINFORCING <br />SPACE ANCHOR <br />3500#, MIN. TENSION 2600#) <br />FIBERMESH <br />WEEP SCREED INSTALLED <br />BAR <br />a <br />BOLTS 6" MAX FROM <br />6 x 6 W1.4 x W1.4 N c <br />^ <br />PER MFR INSTRUCTIONS <br />o <br />END OF 2" x PLATE <br />WWF OR FIBERMESH Cl) E <br />E <br />#3 OR #4 REINFORCING BAR <br />u <br />p <br />• <br />z_ <br />#3 $ #4 LAP SPLICE <br />GRADE 40 MIN. F�40ks�ijj <br />aaDFINISH <br />GRADE °0 <br />25" MIN, LAP [30" MIN. LAP] <br />[GRADE 60 MIN. F <br />a <br />g <br />m <br />D <br />c? <br />— <br />6 MIL VAPOR BARRIER C °°Q— <br />° <br />R 1 7/8' <br />Uj <br />1 <br />#5 REINFORCING BAR <br />#5 LAP SPLICE <br />( — <br />COMP. SOIL. COMPACTED TO <br />° ° <br />36" MIN. LAP [36" MIN. LAP] <br />ON 3" CHAIRS <br />811 <br />1,4„ <br />8„ <br />95% MODIFIED PROCTOR ASTM <br />10" <br />(TYP.) <br />D1557) <br />4" <br />rrr <br />114" <br />#6 REINFORCING BAR <br />#5 STD. 90 HOOK <br />#6 LAP SPLICE <br />TYPICAL INTERIOR BEARING <br />TYPICAL EXTERIOR FRAME WALL FOOTING rE <br />REBAR DETAILS <br />rF <br />WALL w/ UPLIFT <br />G <br />SEE TYP. WALL SECTION FOR ADDITIONAL <br />SCALE: 3/4"=1'-0" S3 <br />SCALE: N.T.S. <br />S3 <br />SCALE: 3/4"=V-0" <br />�,13 <br />SLAB INFORMATION. <br />VARIES <br />SEE PLAN <br />1 1/2" RECESS FOR <br />6 x 6 W1.4 x W1.4 <br />FRAME -DOWN FALSE BEAM <br />(D <br />SEE ROOF PLAN <br />S.G.D. (U.N.O.) <br />WWF OR FIBERMESH <br />O <br />10d NAILS TO TRUSS TOP CHORD <br />FOR TRUSS <br />AT 24" O.C. MAX. xx <br />SEE PLAN FOR <br />CONNECTION INFO <br />° • <br />� <br />_ <br />TOP OF BEAM <br />_ <br />&LAYOUT DESIGN <br />a <br />� <br />Q <br />SEE ROOF PLAN <br />�_ ° a'. ' <br />° <br />(2) HTS20 <br />FOR STRUCTURAL <br />-r <br />E _ — —_ <br />v <br />m <br />Cl) c <br />E. <br />BEAM SIZE & <br />E. <br />a <br />CONNECTION INFO <br />o, <br />4 8 <br />P.T. 2x 1/2" GYP. BD. <br />„ HOLD GYP. BD. <br />FROM SLAB <br />0'-0" J CONT. BEAD SEALA� <br />•.' INTERIOR <br />a.. a. -3 1/2" <br />.. <br />CONCRETE NAILS W 1 1/2 <br />EMBEDMENT @ 12" O.C. <br />STAGGERED, FROM BOTTOM <br />PLATE TO CONCRETE <br />(MIN. SHEAR 180# MIN. <br />TENSION 1204) CONCRETE SLAB <br />m a <br />CO C <br />E _ <br />M 6 MIL VAPOR T <br />BARRIER <br />2X STUDS @ 24" O.C. U.N.O. <br />GARAGE <br />1/2" GYPSUM WALLBOARD U.N.O. <br />W/ DRYWALL SCREWS @ 8"O.C. <br />INSULATION PER CHART <br />ON FLOOR PLAN <br />CONT. BEAD SEALANT <br />6x6W1.4xW1.4 N ' <br />WWF OR FIBERMESH C, <br />i' - A 1 <br />4" 4" <br />INTERIOR WALL SLAB STEP NON-BRG.rK <br />SCALE:3/4"=1'-0" S3 <br />a <br />ac4 P.T. <br />PLATE <br />7116" <br />O.S.B. <br />COLUMN LOCATION <br />T. • <br />2x4 #2 SYP P.T. FRAMING w/ <br />MIN 7/16" O.S.B. SHEATHING <br />SEE A/S3/J/S6 8" <br />z <br />ATTACHED PER NAILING <br />FOR REINF. INFO. <br />OPTION #1 <br />w <br />0 <br />SCHEDULE <br />c <br />> <br />SEE TYP. WALL SECTION FOR ADDITIONAL <br />> <br />w <br />� <br />6x6 P.T. #2 SYP <br />SLAB INFORMATION. <br />Uj <br />rM <br />o <br />W <br />ABU66 <br />SLAB STEP & RECESS 6@ S.G.D. <br />SCALE:3/4"=1'-0" �S3 <br />SECURE 27,4 P.T. BTM. PLATE <br />SEE DETAIL 16/D1 FOR w/ 1/4"x3" TAPCONS 1 <br />MASONRY WALL AND <br />COLUMN TO PORCH SILL AT 8" O.C. <br />ATTACHMENTS & 18/D1 PAD FOOTING <br />FOR COLUMN TO BEAM TRIM PER PLAN 8" MASONRY WALL I I <br />ATTACHMENTS EXTEND FILL CELLS c <br />TO FOUNDATION PAD <br />SQUARE CMU BLOCK BASE, CONT. FOOTING STEEL j j MAT REINFORCING. <br />SIZE VARIES PER PLAN M <br />= w/ MIN. (2) #5 VERTICALS ? GRADE <br />M FILLED SOLID (SEE PLAN FOR <br />SIZE AND REINFORCEMENT) z = _LU - w <br />Cl)w ITTz <br />BRICK PAVERS or SLAB PER 00 v • r • "• - z < <br />COMMUNITY SPECSLL <br />0'-0" FIN. FLR. -- <br />--- - - --- I' -I FOOTING <br />% TOR <br />L3' MIN. CLEARANCE <br />REINFORCEMEN <br />FOOTING WIDTH <br />SEE SCHEDULE <br />PATIO COLUMN FTG. DETAIL <br />Cri <br />0 <br />N <br />o <br />d <br />m <br />UJ <br />�La <br />Cj o <br />LL• <br />C t0 CI N <br />-o Co >< <br />p- <br />fC <br />N p <br />� <br />4 N <br />3 °' x <br />> E c <br />CU G.7 r 4 <br />3 Co <br />ea d m a` <br />N a� <br />� o <br />d y <br />0 <br />?� ..�NS••• <br />'j <br />4.4 <br />�LOe�•�•�?��` <br />Jr/11/�itlllilh1`1e,`\` <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />W <br />E <br />E <br />C <br />Loo <br />N N 0 J <br />ri LL <br />4chv J <br />C J u_ W <br />.^ J LL LL a <br />a <br />13 V w <br />11 <br />Z <br />tm°; <br />oG <br />w o <br />W 'ff^ o°� <br />W °i m w <br />< <br />Z to NZIL CL <br />a N OU � 00 <br />Z <br />W ❑ ❑ <br />� R <br />z N M <br />z � <br />z <br />a � <br />a <br />— N <br />M <br />N z <br />LLJ <br />a <br />U — 2 <br />0 L,-, g <br />(n Lr N <br />Ln <br />II J <br />e <br />8 <br />= t <br />c <br />Q 'Y <br />N Oo <br />o <br />CC)�z <br />M <br />z <br />� <br />z <br />E <br />a <br />� <br />i <br />❑ a <br />CIL <br />X U <br />a <br />J O <br />O� <br />Z <br />N°Qz <br />t <br /><S <br />�z <br />a? <br />N <br />Y <br />m o <br />m� <br />o <br />O¢ <br />a <br />z <br />J <br />� <br />N <br />N <br />a <br />am <br />w <br />w LL <br />z <br />O <br />U <br />a <br />NW <br />W <br />L) 3 <br />;� <br />�L <br />Jo <br />c <br />F� <br />x <br />ao <br />0 ACV <br />> t-0 <br />2 <br />�- <br />O <br />0 <br />LO <br />o^o <br />: r a° <br />co <br />O <br />v / In <br />a <br />Q <br />_c.6 <br />c <br />L:� a) O <br />O <br />O oo j <br />Ln <br />E <br />E <br />CO N <br />f <br />o <br />z <br />f0 <br />C <br />N <br />E E 10 <br />C <br />a <br />E .. .� <br />0 -1 Q 0 <br />J <br />JOB <br />NO: 22-12488-12485 <br />SCALE : AS NOTED <br />SHEET NO. <br />S3M <br />