Laserfiche WebLink
SIMPSON HGAMV <br />W/ <br />(4)1/4"xl 1/2" SDS <br />SCREWS <br />TO BLOCKING & (i <br />1 /4"X2 3/4" <br />TITEN TO CMU <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND <br />FASTENERS. (MIN. FIRST BAYS) <br />SEE STRUCTURAL NOTES AND NAILING TOENAIL w/ <br />SCHEDULE FOR SHEATHING DETAIL-7 (2)16d NAILS—\ <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />MAX. 9" AND FASTENERS. (MIN. FIRST 4 BAYS) <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 BACKNAIL w/ (2)16d NAILS <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />MAX. 9" SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />UNSUPPORTED, AND FASTENERS. (MIN. FIRST 4 BAYS) <br />IF >9" SEE 10/S5 <br />BACKNAIL w/ (2)16d NAILS <br />SEE STRUCTURAL NOTES AND NAILING <br />SCHEDULE FOR SHEATHING DETAIL <br />45°t <br />/ <br />45° ± <br />SEE STRUCTURAL <br />NOTES AND NAILING <br />2x4 CRO§ BRACE <br />SCHEDULE FOR <br />APPROX. 8" FROM <br />SHEATHING DETAILY 2x4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />RIDGE FASTENED AT <br />@ 8'-0" 0/C. <br />EXTEND AT LEAST 90% OF <br />EACH JOINT W/ (3) 10d <br />"L" BRACE TO EXTEND <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />' <br />& (2)10d TOE NAILS @ <br />AT LEAST 90% OF WEB <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />EA. END @ 48" O.C. <br />LENGTH SEE TABLE <br />( ) <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />2x8 P.T. <br />GABLE TRUSS <br />EACH JOINT w/ (3)10d & <br />FROM LEDGER TO <br />SILL <br />1/2" CDX PLYWOOD OR <br />(2)10d TOE NAILS @ EA. <br />BLOCKING <br />' <br />7/16" OSB SHEATHING <br />END <br />ATTACHED W/ 10d <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />NAILS @ 6" O.C. EDGES <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />1/2"CDX PLYWOOD OR 7/16" <br />AND 12" O.C. FIELD <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />OSB SHEATHING ATTACHED <br />1OdX3" @ 3" O/C <br />CORD ATTACHED W/ (2)16d TOENAILS <br />w/ 10d NAILS @ 6" O.C. <br />THROUGH CHORD <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />EDGES AND 12" O.C. FIELD <br />EU <br />INTO 2"x6" P T PLATE <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />MAX. 9" <br />UNSUPPORTED, BACKNAIL w/ (2)16d NAILS MAX, 911 <br />IF >9" SEE 1 O/S5 SEE STRUCTURAL NOTES AND UNSUPPORTED, <br />DETAIL <br />SCHEDULE FOR SHEATHING IF >9" SEE 10/S5 <br />`- DOUBLE TOP PLATE <br />2"x4" CROSS BRACE <br />2x4 CROSS BRACE APPROX. 8" <br />APPROX. 8" FROM <br />FROM RIDGE FASTENED AT <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />EACH JOINT w/ (3)1 Od & (2)1 Od <br />EACH JOINT w/ (3) <br />AT LEAST 90% OF WEB <br />TOE NAILS @ EA. END <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />GABLE TRUSS <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR <br />1/2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />(2)16d <br />7/16" OSB SHEATHING <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />NAILS <br />ATTACHED w/ 1Od NAILS <br />W/ 10d NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA. <br />@ 6" O.C. EDGES AND 12" <br />• <br />AND 12" O.C. FIELD <br />END TYP. TOP & <br />O.C. FIELD <br />BOTTOM ATTACHED <br />(2)16d NAILS <br />W/ (2)16d TOENAILS <br />2x4 "T" ON TOP OF PANEL <br />2x4'T' ON TOP OF PANEL BLOCKING, 2"x6" P.T. SILL NOTCH "L" BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING BLOCKING, FASTEN WITH <br />FASTEN WITH 10dx3" @ 4" 0/C SPACED WEEP SCREED 1/2" x 8" "J" BOLT 48" O.C. THE FIRST (4) ROWS OF TRUSSES 2x4 "T' ON TOP OF PANEL 10dx3" @ 4" O/C <br />INSTALLED PER MANUF. @ WEEP SCREED FROM EA. END TYP. TOP & BOTTOM SIMPSON HGAIOKT w/ (4) 1/4"x1 1/2" SDS SCREWS TO <br />@ 48" O.C. I I I BLOCKING, FASTEN WITH <br />" " MOISTURE BARRIER SIMPSON META12 w/ (7)1Odxl 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2) 16d TOENAILS 10dx3" @ 4" O/C TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C. <br />1/2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM <br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER SIMPSON META12 w/ (7) <br />NOTE: IF EMBEDDED 1Odx1 1/2" NAILS AT EA. <br />STRAP MISSED VERTICAL SECTION 1 TRUSS VERTICAL WEB (24" <br />WEB, USE MSTAM36 w/ (7) O.C. MAX) w/ MIN. 4" <br />1Od NAILS & (4) 1/4"x2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK <br />TITEN ON OUTSIDE S5 <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - MOISTURE BARRIER <br />ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS <br />& (4) 1/4"X2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />GABLE WEB SECTION 2 <br />SCALE: N.T.S. S5 <br />2x4 #2 SYP BLK'G @ 16" <br />O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] <br />- ON FRAMING SHEET FOR SHEATHING <br />REFER TO DETAIL J <br />N N <br />AND FASTENERS. (MIN. <br />FIRST 4 BAYS) <br />ON SHEET S5 FOR <br />r <br />X-BRACING, AND TOP <br />SEE STRUCTURAL <br />CHORD BLOCKING <br />N - <br />NOTES AND NAILING <br />INFORMATION <br />`° <br />SCHEDULE FOR <br />SHEATHING DETAIL <br />BACKNAIL w/ <br />• WOOD TRUSSES <br />1 1 1/ <br />co � <br />2"x4" CROSS BRACE <br />(2) 16d NAILS <br />APPROX. 8" FROM <br />2x4 RAT RUN BRACING <br />" <br />RIDGE FASTENED AT <br />AT 24" O.C. ON TOP OF <br />EACH JOINT w/ (3) <br />BOTT. CHORD FOR 4 <br />10d & (2)10d TOE <br />TRUSS SPANS <br />ATTACHED W/ 2 -16d <br />NAILS @ EA. END <br />AT EA. TRUSS JOINT <br />�� �� �� �� 11 1 <br />(2) 2 x 4 LAMINATIONS W/ (1) ROW (3) 2 x 4 LAMINATIONS W/ (1) ROW (3) 2 x 6 LAMINATIONS W/ (2) ROWS OF <br />2x4 PANEL BLOCKING <br />OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS <br />@ 48" 0/C FOR THE <br />(2) 16d NAILS <br />2x4 BLOCKING @ 24" <br />(D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL " 11 <br />(D = 0.207 , L = 41/2) OR EQUAL <br />FIRST (4) ROWS OF <br />O/C w/ (2)16d <br />TRUSSES FROM EA. <br />TOENAILS @ EA. END <br />NOTES: <br />END TYP. TOP & <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL <br />BOTTOM ATTACHED <br />MASONRY WALL <br />OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) <br />w/ (2)16d TOENAILS <br />It I <br />ARCHITECTURAL FINISH <br />2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />Dq <br />OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />W GABLE TRUSS EB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T' BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB -' <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" O/C GABLE TRUSS <br />TRUSS VERTICAL <br />SIMPSON SP2 w/ (12) 10d <br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE NAILS AT EACH STUD (2) 2"x8" "L" BRACE <br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) FASTENED WITH (3) <br />SECTION 16d PER SIDE <br />3 SECTION 4 SCISSOR GABLE "T" BRACE 7 <br />SCALE: N.T.S. ��5� SCALE: N.T.S. S5 AS PER HIB 91 SCALE: N.T.S. S5 <br />MAX. 9" <br />UNSUPPORTED, 8d @ 6"O/C <br />IF >9" SEE 10/S5 rW00D TRUSSES <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />W/ 10d NAILS @ 6" O.C. <br />SIMPSON HGAM10KTA w/ (4) <br />E ES AND 12" O.C. FIELD <br />1/4"xi 1/2" SDS SCREWS TO <br />JACK TRUSS <br />BLOCKING & (4)1/4"X2 3/4" <br />SEE PLAN FOR <br />TITEN TO CMU <br />CONNECTION <br />2x4'T"ON TOP OF PANEL <br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, FASTEN WITH 2x4 BLOCKING W/ <br />EXT. WALL CONN. COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF 1Odx3" @ 4" O/C (2)12d TOENAILS <br />NON -LOAD BEARI G LOCATION D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: 3/4"=V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 SECTION g _ <br />IINIMUM 2x <br />:ROSS BRACING <br />3EE PLAN FOR <br />OCATIONS) <br />(2)16d PER <br />JOINT <br />/- CONTINUOUS BOTTOM CORD BRACING 211x4" MIN. <br />'SEE <br />EMM/S5 <br />CROSS BRACING DETAIL J 1 <br />SCALE: N.T.S. <br />TOENAIL 1 <br />(2)16d NA <br />12" <br />SH SCHEDULE <br />ATTACHMENT <br />i SYP BLK'G @ 16" O.C. <br />1 x 0.131" <br />AILS EA. SIDE <br />2x4 #2 SYP w/ 1 Od <br />XO.131" @ 8" O.C. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL 10 <br />SCALE: N.T.S. S5 <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />2 x 4 BLOCKING w/ (2)1 Od <br />TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />• <br />Z <br />w <br />BRACING w/ (3)1 Od x 3" AT <br />EACH CONN. @ 24" O/C <br />MOISTURE BARRIER <br />BOND BEAM <br />- MASONRY WALL <br />4RCHITECTURAL FINISH <br />EXT. WALL CONN. NON - LOAD <br />BEARING LOCATIO (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />E <br />S5 <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 I CONTINUOUS BOTTW CHORD BRACING 2X4 MIN. <br />I11IIII <br />IAA! <br />NOTE: ZTOP CHORD 2x4 #2 SYP BRACING <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />ZBOTTOM <br />@ 16" O.C. MAX. FOR FIRST (4) <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />BAYS <br />THAT MY BE REQUIRED <br />CHORD GABLE END BRACING <br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT <br />@ 4'-0" O.C. MAX. FOR FIRST (4) BAYS <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />rL� <br />AS PER BCSI <br />SCISSOR TRUSS <br />SCALE: N.T.S. <br />I <br />"L" BRACING REQUIREMENTS 2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />OVERLAP TRUSS BRACING FIXED LOCATION ATTACHED W/ (2)10d AT <br />PRE-ENGINEERED AT LEAST TWO TRUSS SPACES 6" OVERLAP STUD NO (1) 2"x4" (U.N.O.) 2"x6" (U.N.O.) EA. TRUSS (NOTE: BRACING MAY BE <br />WOOD TRUSSES SPACING "L" BRACE "L" BRACE "L" BRACE PLACED ON EITHER TOP OR BOTTOM OF <br />24" 010" - 3'-0" 3'4" - 6'4" 6'-0" & GREATER THE BOTTOM CORD) <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />MINIMUM (2)16d PER JOINT \- MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL rm <br />SCALE: N.T.S. S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />a <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 1 Odx3" NAILS @ 4" 0/C, <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"x1 1/2" SDS <br />SCREWS TO TRUSS & (4) l/4"x3" SDS SCREWS <br />TO PLATES (TYP.) <br />/—GABLE TRUSS <br />'--STUDS @ 16" O.C. <br />GABLE END BRACING DETAIL SCALE:3/4"=T-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />1 V-0" MAX. <br />CC <br />o <br />0 <br />a <br />qc� <br />CORNER JACK <br />Y <br />v¢ <br />W <br />Z <br />m <br />O <br />U <br />, <br />HIP FRAMING REFERENCE PLAN <br />COSMETIC DROP CEILING FRAMING <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />e+� <br />N <br />o_ <br />C <br />o <br />o <br />m <br />a <br />�- " o <br />U_ <br />CJ .0 Sao t- N <br />M = <br />In _= CN t <br />429 <br />3:= <br />°> <br />Co a <br />�o <br />� d d d <br />i N C O <br />=.�° <br />In a a <br />C <br />tv o <br />0 <br />o001111�+tiirrr�e <br />`\ <br />P <br />f'N5 ' • 4 <br />��- 12 <br />f� 0 <br />z <br />'4 r <br />?fir'/ �"? <br />04111111110 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residentlal <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />QE <br />5 <br />0 <br />0 <br />N � � 0/ <br />`' co <br />, <br />•/ <br />ei <br />A A <br />O q► <L <br />Q <br />QjN Mat <br />C I u- W <br />o u- ow <br />Z <br />-9 'L <br />= �_ O1 0 <br />w g <br />W_ <br />O <br />m N O <br />0 cp m <br />� NZ d J <br />Z <br />N OU <br />WCD <br />❑❑ <br />z C) <br />z § 8go <br />z � � <br />v <br />J <br />t Y7 <br />N <br />N <br />M <br />O <br />V <br />u- <br />4-J <br />W <br />j <br />OI,J <br />In <br />U 5 <br />l iJ J <br />I e <br />a <br />I <br />2� <br />_ = <br />U c � �3 <br />1 <br />• <br />a 0 <br />s <br />w <br />M <br />M <br />J <br />p � <br />zo <br />Z <br />a <br />� <br />}� <br />QE <br />0 <br />U <br />0' <br />%U <br />Co <br />U <br />° <br />z <br />o ECL <br />O <br />N <br />N i <br />ao <br />z <br />w <br />ro <br />C <br />iz <br />U <br />.3 <br />10 <br />Oz <br />Z <br />z <br />N J <br />a' <br />ON <br />� z <br />W <br />N <br />� <br />R* <br />a° <br />m w <br />wf <br />z <br />j <br />o <br />co <br />?a <br />�F <br />o <br />� <br />2I6 <br />U <br />�N <br />0 <br />>M <br />a <br />ai <br />m <br />I— <br />O <br />J <br />i <br />Lfj <br />o^o <br />c <br />Q <br />=3 r— <br />0 <br />0- <br />LO <br />Co <br />(n O <br />Lp <br />m <br />Q <br />_a <br />NQ <br />M <br />L.n <br />rn o <br />0 <br />c <br />O <br />c0 Q <br />00 j <br />M <br />LO <br />1 <br />co <br />0) <br />T <br />E <br />mN <br />LO <br />(0 <br />r <br />Z <br />Z <br />E <br />E <br />a <br />U � <br />'0 <br />JOB <br />NO: 22-12488-12485 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S5 <br />s <br />v <br />