My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (106)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (106)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:29:27 AM
Creation date
2/18/2025 4:37:54 PM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Stevens Construction
Building Plans - Permit #
1995
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 3 4 5 6 <br />E <br />C <br />10 <br />B <br />A <br />GENERAL <br />DEMOLITION NOTES: <br />1. LIGHT LINES INDICATE EXISTING <br />CONSTRUCTION TO REMAIN. <br />2. REMOVE ALL EXISTING CONSTRUCTION <br />INDICATED BY BOLD DASHED LINES. <br />3. THE WORK INCLUDED IN THIS PROJECT IS <br />DIVIDED INTO MULTIPLE SUB -PROJECT AREAS. <br />THE AREA DIVISION IS REPRESENTED IN PLAN <br />BY VERY BOLD DASHED LINES. <br />4. SPACES SHOWN IN PLAN WITH A GRAY HATCH <br />ARE OUTSIDE OF THE SUB -PROJECT AREA <br />INCLUDED ON THIS SHEET. SEE RESPECTIVE <br />SHEETS FOR WORK IN OTHER SUB -PROJECT <br />AREAS. <br />5. SEE SHEET A-100 FOR DEMOLITION AND NEW <br />WORK FLOOR PLANS SHOWING THE SUB - <br />A PROJECT AREA DIVISION AND IDENTIFICATION. <br />6. REFER TO A-100 FOR DEMOLITION AND ICRA <br />REQUIREMENTS AND NOTES <br />RECEIVING <br />DOCK <br />T T—♦T�-}T <br />6-5" <br />12' 01, -I 8 <br />STICK MAT 3 <br />POOL/ <br />' I STORAGE <br />116 <br />9 'tl <br />A 11 <br />y 12 <br />�2FE <br />13 12 <br />1�—== <br />. . i <br />STORAGE <br />120 <br />J PASSAGE <br />100ME _M_1211521�1i. <br />�,.. <br />v: <br />I � <br />KEYED NOTES: DEMOLITION - <br />SUB -PROJECT AREA C <br />1� <br />THIS SPACE IS TO REMAIN ACTIVE FOR THE <br />DURATION OF THE CONSTRUCTION WORK. <br />CONTRACTOR TO KEEP SPACE FREE OF DEBRIS <br />AND OBSTRUCTIONS. <br />CONTRACTOR TO LOCATE 10LB TYPE ABC FIRE <br />EXTINGUISHER WITHIN WORK AREA <br />O <br />PROVIDE TACKY MATS / WALK -OFF MATS AT ENTRY <br />TO CONSTRUCTION AREA. <br />LOCATE HEPA FILTER NEGATIVE AIR MACHINE(S) TO <br />NEGATIVELY PRESSURIZE CONSTRUCTION AREA. <br />O <br />CONTRACTOR TO INSTALL TEMPORARY EXIT SIGN <br />WHICH INDICATES THE PATH OF EGRESS TO AN EXIT <br />ACCESS CORRIDOR FOR THE DURATION OF THE <br />CONSTRUCTION PERIOD. <br />6� <br />EXISTING HYDROTHERAPY POOL WITH HYDROLIC <br />LIFT PLATFORM. SEE NEW WORK AND DETAILS. <br />O7 <br />PORTION OF EXTERIOR WALL TO BE DEMOLISHED <br />FOR INSTALLATION OF NEW EXTERIOR DOOR. SEE <br />DETAILS ON SHEET A-112 FOR EXTERIOR WALL <br />DEMOLITION AND NEW WORK. <br />�8 <br />TEMPORARY ICRA WALL CONSTRUCTION. THIS <br />SPACE IS ON THE EXTERIOR OF THE BUILDING. <br />CONTRACTOR TO ENSURE TEMPORARY WALL <br />CONSTRUCTION IS AIR -TIGHT AND PREVENTS <br />OUTSIDE AIR, WATER, DEBRIS, AND VERMIN FROM <br />ENTERING THE BUILDING & WALL CAVITY FOR THE <br />DURATION OF TIME THE EXTERIOR WALL IS <br />DEMOLISHED. TEMORARY DOOR TO THE EXTERIOR <br />IS TO BE LOCKED AT ALL TIMES. <br />�9 <br />EXISTING FINISH FLOORING TO REMAIN. <br />10 <br />EXISTING SHOWER FIXTURES AT THIS LOCATION TO <br />BE DEMOLISHED AND REMOVED. <br />11 <br />EXISTING DOOR AND FRAME TO BE REMOVED AND <br />SALVAGED FOR REUSE. DOOR OPENING TO BE <br />INFILLED. SEE SUB -PROJECT AREA I FOR DOOR <br />REMOVAL AND INFILL WORK. <br />12 <br />EXISTING WALL ASSEMBLY TO BE UPGRADED TO BE <br />1-HOUR FIRE RATED SIMILAR TO UL RATED <br />ASSEMBLY U-465. UPGRADE WALLS AS REQUIRED, <br />INCLUDING, BUT NOT LIMITED TO: RATED WALL <br />CORNER TURNS, HEAD OF WALL ASSEMBLIES, <br />DUCTWORK, PENETRATIONS, & STENCILING. SEE <br />DETAILS ON GENERAL SHEETS FOR RATED <br />PARTITIONS AND ASSEMBLIES. <br />13 <br />EXISTING STOREFRONT WINDOWS AND DOOR TO <br />BE REMOVED AND INFILLED. <br />GENERAL NEW WORK <br />NOTES: <br />1. ALL WALLS ARE TYPE U UNLESS OTHERWISE <br />NOTED. <br />2. ALL DIMENSIONS ARE TO FINISH FACE OF <br />WALLS. <br />3. THE WORK INCLUDED IN THIS PROJECT IS <br />DIVIDED INTO MULTIPLE SUB -PROJECT AREAS. <br />THE AREA DIVISION IS REPRESENTED IN PLAN <br />BY VERY BOLD DASHED LINES. <br />4. SPACES SHOWN IN PLAN WITH A GRAY HATCH <br />ARE OUTSIDE OF THE SUB -PROJECT AREA <br />INCLUDED ON THIS SHEET. SEE RESPECTIVE <br />SHEETS FOR WORK IN OTHER SUB -PROJECT <br />AREAS. <br />5. SEE SHEET A-100 FOR DEMOLITION AND NEW <br />WORK FLOOR PLANS SHOWING THE SUB- <br />PROJECT AREA DIVISION AND IDENTIFICATION. <br />Al <br />NEW COLUMN <br />STRUCTURE BELOV <br />DECI <br />POOL/__ - <br />STORAGE <br />116 <br />EXIST. PISTON T( <br />REMAII <br />KEYED NOTES: NEW WORK - <br />SUB -PROJECT AREA C <br />1� <br />PATCH AND REPAIR WALL WHERE TEMPORARY <br />PARTITION IS DEMOLISHED. PAINT TO MATCH <br />EXISTING. PAINT WALL TO NEAREST CORNER OR <br />DOORFRAME. <br />0 <br />EXISTING POOL HYDROLIC PLATFORM. <br />CONTRACTOR TO CONSTRUCT AND INSTALL NEW <br />STRUCTURE BENEATH PLATFORM TO FIX <br />PLATFORM IN PLACE. SEE DETAILS. <br />0 <br />NEW EXTERIOR DOOR. SEE DETAILS ON SHEET <br />A-112 FOR EXTERIOR WALL WORK. SEE EXTERIOR <br />DOOR NOA INFORMATION ON SHEET G-001. <br />® <br />DOOR OPENING WHERE EXISTING DOOR AND <br />FRAME HAVE BEEN REMOVED TO BE INFILLED. SEE <br />SUB -PROJECT AREA I FOR DOOR INFILL WORK. <br />0 <br />CONTRACTOR TO INCLUDE FRAMING WITHIN WALL <br />FOR FUTURE DOOR. CONSTRUCT LIGHT -GAUGE <br />FRAMING STRUCTURAL HEADER FOR FUTURE <br />DOOR. STRUCTURAL HEADER TO BE SPECIALTY <br />ENGINEERED AND SIGNED & SEALED BY A FL <br />LICENSED SPECIALTY ENGINEER, I.E. CLARK- <br />DIETRICH. SEE INTERIOR ELEVATIONS FOR <br />LOCATION. <br />0 <br />m _ <br />1 <br />STORAGE II <br />PASSAGE <br />13 OEM a <br />rl <br />a <br />zi \ <br />RCP GENERAL NOTES <br />1. REFER TO ROOM FINISH SCHEDULE FOR <br />ADDITIONAL INFORMATION. <br />2. ALL CEILINGS ARE EXISTING TO REMAIN, U.N.O. <br />3. REFER TO MECHANICAL DRAWINGS FOR QUANTITY <br />AND TYPE OF DIFFUESERS, RETURN AIR GRILLES, <br />AND EXHAUST GRILLES. FOR NEW AND/OR <br />RELOCATED DEVICES, CONTRACTOR TO SCRIBE <br />CEILING MATERIALS CAREFULLY FOR A TIGHT FIT. <br />4. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY <br />AND TYPE OF LIGHTS, SPEAKERS, DETECTORS, <br />POWER OUTLETS, ETC. CONTRACTOR TO FIELD <br />VERIFY LOCATION & QUANTITY OF DEVICES IN <br />EXISTING CEILING. FOR NEW AND/OR RELOCATED <br />LIGHTS & DEVICES, CONTRACTOR TO SCRIBE CEILING <br />MATERIALS CAREFULLY FOR A TIGHT FIT. <br />5. THE ENTIRE PROJECT HAS FIRE SPRINKLER HEADS <br />IN CEILING. ALL EXISTING HEADS ARE EXISTING TO <br />REMAIN, U.N.O.. FOR NEW AND/OR RELOCATED <br />HEADS, CONTRACTOR TO SCRIBE CEILING <br />MATERIALS CAREFULLY FOR A TIGHT FIT. <br />6. ALL EXISTING TO REMAIN GRILLES, DIFFUSERS AND <br />LIGHTS ETC. WITHIN SCOPE OF PROJECT TO BE <br />CLEANED. <br />7. ALL EXISTING CEILING DEVICES TO BE RETURNED <br />TO ORIGINAL OPERATING CONDITION UPON THE <br />COMPLETION OF ANY CEILING WORK <br />RCP KEYED NOTES - <br />SUB -PROJECT AREA C <br />it <br />NO CEILING WORK IN THIS SPACE. EXISTING <br />CEILING TO REMAIN. <br />EXISTING CEILING: <br />- MINIMAL TO BE REMOVED AS REQUIRED FOR <br />NEW ABOVE CEILING WORK. <br />- PROTECT REMOVED CEILING ELEMENTS FOR <br />REINSTALLATION <br />- RESTORE TO ORIGINAL CONDITION <br />- NEW CEILING MATERIAL TO MATCH EXISTING <br />ADJACENT <br />- FIELD VERIFY EXISTING ELECTRICAL AND <br />MECHANICAL EQUIPMENT. <br />3] <br />EXISTING SUSPENDED LINEAR LIGHT FIXTURES <br />TO REMAIN. <br />PASSAGE <br />100 �...;���� <br />WALL RATINGS: <br />1 HOUR FIRE <br />--4-S—♦S $ S- 1 HOUR FIRE/ SMOKE BARRIER <br />2 HOUR FIRE <br />-+*-SS___*4-S- 2 HOUR FIRE/ SMOKE BARRIER <br />___4_T—♦T TEMPORARY 1 HOUR FIRE <br />S S SMOKE BARRIER <br />"GRAY" = EXISTING RATING <br />TO REMAIN <br />PARTITIONS: <br />EXISTING/REMAINING <br />NEW WORK <br />DEMOLISHED <br />RCP SYMBOL LEGEND <br />ACOUSTICAL TILE CEILING (24X24) <br />ACOUSTICAL TILE CEILING (24X48) <br />GYPSUM CEILING - PAINTED <br />® <br />FLUORESCENT LIGHT FIXTURE <br />FLUORESCENT LIGHT FIXTURE <br />B <br />INCANDESCENT LIGHT FIXTURE <br />SMOKE DETECTOR <br />❑ <br />SPEAKER <br />® <br />EXIT LIGHT <br />FMHVAC <br />SUPPLY DIFFUSER <br />HVAC RETURN DIFFUSER <br />mCEILING <br />ACCESS PANEL <br />FIRE SPRINKLER (GRAY = EXISTING) <br />iw <br />z <br />' J <br />la <br />H <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />J <br />1 <br />a <br />3 <br />THIS SHEET ISSUED <br />IN ITS ENTIRETY <br />E <br />FBI <br />C <br />A <br />chapuis design group <br />architecture.pa <br />510 VONDERBURG DR. SUITE 216 <br />BRANDON, FL 33511 <br />Tel. 813-667-2340 <br />CGDPA - FL # AA-26003049 <br />exp U.S. Services Inc. <br />t: +1.407.660.0088 f: <br />+1.407.660.1655 <br />2601 Westhall Lane <br />Maitland, FL 32751 <br />USA <br />0-4 <br />so <br />w4l; <br />www.exp.com <br />000 <br />r o*ex <br />Project #: 21000928 <br />Cert of Auth: 29701 <br />PROJECT FOR <br />ADVENT HEALTH - <br />ZEPHYRHILLS <br />UROLOGY SUITE <br />RENOVATION <br />7050 Gall Blvd. <br />Zephyrhills, FL 33541 <br />Wr <br />Ad Vient Health <br />AHCA CLIENT CODE / FILE NUMBER: 23/100046-126 <br />3 <br />APRIL 14, 2021 <br />ASI No. 1- AHCA & OWNER REVISIONS <br />2 <br />MARCH 17, 2021 <br />AHCA STAGE 3 DOCUMENT SET <br />1 <br />FEB. 19, 2021 <br />ADDENDUM 1 - <br />MARK <br />DATE <br />DESCRIPTION <br />PROJECT NUMBER <br />042.20.164.01 <br />ORIGINAL ISSUE <br />MAR. 17, 2021 - <br />PROJECT MANAGER <br />TEC <br />PROJECT DESIGNER <br />TEC <br />PROJECT ARCHITECT <br />THOMAS E. CHAPUIS AR97109 <br />LANDSCAPE ARCHITECT <br />N/A <br />CIVIL ENGINEER <br />N/A <br />STRUCTURAL ENGINEER <br />N/A <br />MECHANICAL ENGINEER <br />N/A <br />ELECTRICAL ENGINEER <br />NIA <br />INTERIOR DESIGNER <br />TEC <br />EQUIPMENT PLANNER <br />N/A <br />DRAWN BY <br />SDL <br />SUB -PROJECT AREA <br />C -PLANS <br />SCALE As indicated <br />Null I A=110 <br />Al ENLARGED PLAN - AREA C - POOL / STORAGE - DEMOLITION A3 ENLARGED PLAN - AREA C - POOL / STORAGE - NEW WORK A5 ENLARGED CEILING PLAN - AREA C POOL / STORAGE NEW WORK <br />1 /4 = 1 -0 1 /4" = V-0" 1 /4 = 1 -0 <br />1 2 3 4 5 6 Project Status <br />_ 1 fill -,1 - - I <br />
The URL can be used to link to this page
Your browser does not support the video tag.