Laserfiche WebLink
E <br />A <br />C <br />B <br />A <br />1 2 3 4 5 6 -ddmmmlmb- <br />GENERAL <br />DEMOLITION NOTES: <br />1. LIGHT LINES INDICATE EXISTING <br />CONSTRUCTION TO REMAIN. <br />2. REMOVE ALL EXISTING CONSTRUCTION <br />INDICATED BY BOLD DASHED LINES. <br />3. THE WORK INCLUDED IN THIS PROJECT IS <br />DIVIDED INTO MULTIPLE SUB -PROJECT AREAS. <br />THE AREA DIVISION IS REPRESENTED IN PLAN <br />BY VERY BOLD DASHED LINES. <br />4. SPACES SHOWN IN PLAN WITH A GRAY HATCH <br />ARE OUTSIDE OF THE SUB -PROJECT AREA <br />INCLUDED ON THIS SHEET. SEE RESPECTIVE <br />SHEETS FOR WORK IN OTHER SUB -PROJECT <br />AREAS. <br />5. SEE SHEET A-100 FOR DEMOLITION AND NEW <br />WORK FLOOR PLANS SHOWING THE SUB- <br />PROJECT AREA DIVISION AND IDENTIFICATION. <br />6. REFER TO A-100 FOR DEMOLITION AND ICRA <br />REQUIREMENTS AND NOTES <br />KEYED NOTES: DEMOLITION - <br />SUB -PROJECT AREA H <br />1O THIS SPACE IS TO REMAIN ACTIVE FOR THE <br />DURATION OF THE CONSTRUCTION WORK. <br />CONTRACTOR TO KEEP SPACE FREE OF DEBRIS <br />AND OBSTRUCTIONS. <br />2� CONTRACTOR TO LOCATE 10LB TYPE ABC FIRE <br />EXTINGUISHER WITHIN WORK AREA <br />3� PROVIDE TACKY MATS / WALK -OFF MATS AT ENTRY <br />TO CONSTRUCTION AREA. <br />LOCATE HEPA FILTER NEGATIVE AIR MACHINE(S) TO <br />NEGATIVELY PRESSURIZE CONSTRUCTION AREA. <br />O EXISTING DOOR AND FRAME TO BE REMOVED AND <br />SALVAGED FOR REUSE. DOOR OPENING TO BE <br />INFILLED. PROTECT DOOR AND FRAME FOR <br />REINSTALLATION. <br />6O EXISTING CASEWORK TO REMAIN. <br />EXISTING CEILING MOUNTED CURTAIN AND TRACK <br />TO BE REMOVED. <br />O EXISTING FINISH FLOORING TO BE REMOVED. PREP <br />FLOOR AS REQUIRED TO RECEIVE NEW FINISH <br />FLOORING. SEE FINISH FLOOR PLAN AND SCHEDULE <br />O THE EXISTING WALLS WITHIN THIS SPACE INCLUDE <br />EXISTING APPLIED WALLPAPER. SEE DETAILS ON <br />SHEET A-401 FOR WORK RELATED TO EXISTING <br />WALLPAPER. TYPICAL OF ALL EXISTING EXAM <br />ROOMS. <br />0 <br />GENERAL NEW WORK <br />NOTES: <br />1. ALL WALLS ARE TYPE U UNLESS OTHERWISE <br />NOTED. <br />2. ALL DIMENSIONS ARE TO FINISH FACE OF <br />WALLS. <br />3. THE WORK INCLUDED IN THIS PROJECT IS <br />DIVIDED INTO MULTIPLE SUB -PROJECT AREAS. <br />THE AREA DIVISION IS REPRESENTED IN PLAN <br />BY VERY BOLD DASHED LINES. <br />4. SPACES SHOWN IN PLAN WITH A GRAY HATCH <br />ARE OUTSIDE OF THE SUB -PROJECT AREA <br />INCLUDED ON THIS SHEET. SEE RESPECTIVE <br />SHEETS FOR WORK IN OTHER SUB -PROJECT <br />AREAS. <br />5. SEE SHEET A-100 FOR DEMOLITION AND NEW <br />WORK FLOOR PLANS SHOWING THE SUB- <br />PROJECT AREA DIVISION AND IDENTIFICATION. <br />KEYED NOTES: NEW WORK - <br />SUB -PROJECT AREA H <br />0 DOOR OPENING WHERE EXISTING DOOR AND <br />FRAME HAVE BEEN REMOVED TO BE INFILLED. <br />INFILL W/ METAL STUD & GYPSUM CONSTRUCTION <br />TO MATCH EXISTING WALL ASSEMBLY. GYPSUM TO <br />BE FLUSH W/ EXISTING WALL FACE ON BOTH SIDES <br />OF WALL. <br />0 INSTALL DOOR AND FRAME RELOCATED FROM <br />LOCKER RM 117. SEE DOOR SCHEDULE FOR MORE <br />INFORMATION. <br />0 INSTALL DOOR AND FRAME RELOCATED FROM <br />LOCKER RM 118. SEE DOOR SCHEDULE FOR MORE <br />INFORMATION. <br />® NEW PARTITION TO BE CONSTRUCTED FROM <br />FLOOR TO UNDERSIDE OF EXISTING CEILING. SEE <br />DETAIL. <br />5� PATIENT EXAM TABLE AND HEADWALL. SEE <br />EQUIPMENT PLANS AND INTERIOR ELEVATIONS. <br />6Q EXISTING CASEWORK TO REMAIN. <br />a THE EXISTING WALLS WITHIN THIS SUB -PROJECT <br />AREA INCLUDE EXISTING APPLIED WALLPAPER. <br />SEE DETAILS ON SHEET A-401 FOR WORK RELATED <br />TO EXISTING WALLPAPER. TYPICAL OF ALL <br />EXISTING EXAM ROOMS AND RECEPTION AREA. <br />RCP GENERAL NOTES <br />1. REFER TO ROOM FINISH SCHEDULE FOR <br />ADDITIONAL INFORMATION. <br />2. ALL CEILINGS ARE EXISTING TO REMAIN, U.N.O. <br />3. REFER TO MECHANICAL DRAWINGS FOR QUANTITY <br />AND TYPE OF DIFFUESERS, RETURN AIR GRILLES, <br />AND EXHAUST GRILLES. FOR NEW AND/OR <br />RELOCATED DEVICES, CONTRACTOR TO SCRIBE <br />CEILING MATERIALS CAREFULLY FOR A TIGHT FIT. <br />4. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY <br />AND TYPE OF LIGHTS, SPEAKERS, DETECTORS, <br />POWER OUTLETS, ETC. CONTRACTOR TO FIELD <br />VERIFY LOCATION & QUANTITY OF DEVICES IN <br />EXISTING CEILING. FOR NEW AND/OR RELOCATED <br />LIGHTS & DEVICES, CONTRACTOR TO SCRIBE CEILING <br />MATERIALS CAREFULLY FOR A TIGHT FIT. <br />5. THE ENTIRE PROJECT HAS FIRE SPRINKLER HEADS <br />IN CEILING. ALL EXISTING HEADS ARE EXISTING TO <br />REMAIN, U.N.O.. FOR NEW AND/OR RELOCATED <br />HEADS, CONTRACTOR TO SCRIBE CEILING <br />MATERIALS CAREFULLY FOR A TIGHT FIT. <br />6. ALL EXISTING TO REMAIN GRILLES, DIFFUSERS AND <br />LIGHTS ETC. WITHIN SCOPE OF PROJECT TO BE <br />CLEANED. <br />7. ALL EXISTING CEILING DEVICES TO BE RETURNED <br />TO ORIGINAL OPERATING CONDITION UPON THE <br />COMPLETION OF ANY CEILING WORK <br />RCP KEYED NOTES - <br />SUB -PROJECT AREA H <br />1i <br />NO CEILING WORK IN THIS SPACE. EXISTING <br />CEILING TO REMAIN. <br />EXISTING CEILING: <br />- MINIMAL TO BE REMOVED AS REQUIRED FOR <br />NEW ABOVE CEILING WORK. <br />- PROTECT REMOVED CEILING ELEMENTS FOR <br />REINSTALLATION <br />- RESTORE TO ORIGINAL CONDITION <br />- NEW CEILING MATERIAL TO MATCH EXISTING <br />ADJACENT <br />- FIELD VERIFY EXISTING ELECTRICAL AND <br />MECHANICAL EQUIPMENT. <br />` <br />EXISTING CEILING TO REMAIN. NEW PARTITIONS <br />L l <br />TO BE BUILT UP TO UNDERSIDE OF EXISTING <br />CEILING. SEE DETAIL. <br />EXISTING RECESSED CEILING LIGHT FIXTURE TO <br />L'J <br />REMAIN. MILLWORK LIGHT SHELF BELOW LIGHT <br />FIXTURE. SEE INTERIOR ELEVATIONS. <br />F5 <br />EXISTING CEILING GRID TO REMAIN. INSTALL NEW <br />CEILING TILES. SEE FINISH SCHEDULE FOR MORE <br />INFORMATION. <br />a <br />F <br />j[ <br />RCP SYMBOL LEGEND <br />ACOUSTICAL TILE CEILING (24X24) <br />ACOUSTICAL TILE CEILING (24X48) <br />Q <br />GYPSUM CEILING - PAINTED <br />FLUORESCENT LIGHT FIXTURE <br />FLUORESCENT LIGHT FIXTURE <br />0 <br />INCANDESCENT LIGHT FIXTURE <br />SMOKE DETECTOR <br />❑ <br />SPEAKER <br />EXIT LIGHT <br />HVAC SUPPLY DIFFUSER <br />HVAC RETURN DIFFUSER <br />CEILING ACCESS PANEL <br />FIRE SPRINKLER (GRAY = EXISTING) <br />WALL RATINGS: <br />1 HOUR FIRE <br />--S—$S—$-S- 1 HOUR FIRE/ SMOKE BARRIER <br />2 HOUR FIRE <br />-��S��-S��►-S- 2 HOUR FIRE/ SMOKE BARRIER <br />�T T TEMPORARY 1 HOUR FIRE <br />S S SMOKE BARRIER <br />- k "GRAY" = EXISTING RATING <br />TO REMAIN <br />PARTITIONS: <br />0 EXISTING/REMAINING <br />--) NEW WORK <br />DEMOLISHED <br />3 <br />THIS SHEET ISSUED <br />IN ITS ENTIRETY <br />E <br />0 <br />B <br />A <br />chapuis design group <br />arch itecture.pa <br />510 VONDERBURG DR. SUITE 216 <br />BRANDON, FL 33511 <br />Tel. 813-667-2340 <br />CGDPA - FL # AA-26003049 <br />exp U.S. Services Inc. <br />t: +1.407-660-0088 <br />f: +1.407.660.1655 <br />2601 Westhall Lane <br />Maitland, FL 32751 <br />USA <br />i- <br />wvvw.exp.com <br />•� i, <br />*ex <br />Project #: 21000928 <br />Cart of Auth: 29701 <br />PROJECT FOR <br />ADVENT HEALTH - <br />ZEPHYRHILLS <br />UROLOGY SUITE <br />RENOVATION <br />7050 Gall Blvd. <br />Zephyrhills, FL 33541 <br />3 <br />APRIL 14, 2021 <br />ASI No.1 - AHCA & OWNER REVISIONS <br />2 <br />MARCH 17, 2021 <br />AHCA STAGE 3 DOCUMENT SET <br />1 <br />FEB.19, 2021 <br />ADDENDUM 1 - <br />MARK <br />DATE <br />DESCRIPTION <br />PROJECT NUMBER <br />042-20-164.01 <br />ORIGINAL ISSUE <br />MAR. 17, 2021 - <br />PROJECT MANAGER <br />TEC <br />PROJECT DESIGNER <br />TEC <br />PROJECT ARCHITECT <br />THOMAS E. CHAPUIS - AR97109 <br />LANDSCAPE ARCHITECT <br />N/A <br />CIVIL ENGINEER <br />N/A <br />STRUCTURAL ENGINEER <br />N/A <br />MECHANICAL ENGINEER <br />N/A <br />ELECTRICAL ENGINEER <br />N/A <br />INTERIOR DESIGNER <br />TEC <br />EQUIPMENT PLANNER <br />N/A <br />DRAWN BY <br />SDL <br />SUB -PROJECT AREA <br />H -PLANS <br />As indicated <br />a <br />PROJECT <br />ENLARGED PLAN - AREA H - EXAM ROOMS - DEMOLITION ENLARGED PLAN - AREA H - EXAM ROOMS - NEW WORK ENLARGED CEILING PLAN - AREA H - EXAM ROOMS - NEW WORK NORTH Aml 35 <br />A5 <br />Al1 /4" = V-0" A3 1 /4" = V-0" 1 /4" = V-13" <br />o - <br />i v 1 2 3 4 5 6 Project Status <br />