Laserfiche WebLink
1 2 3 4 5 6 <br />DEMO RCP KEYED NOTES RCP KEYED NOTES <br />EXISTING HVAC: <br />O 1 <br />CENTERLING OF BOOM LIGHT IS BASED ON LOCATION OF - COVER AND PROTECT EXISITNG BOOM LIGHT. SEE RCP DEMO. <br />BE VERIFIED <br />PROJECT LIMIT LINE - LOCATIONS TMECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION PROJECT LIMIT LINE <br />NEW HVAC /DIFFUSERS: <br />EXISTING FIRE PROTECTION: - LOCATIONS TO BE VERIFIED <br />0 ALL SPRINKLER HEADS EXISTING TO REMAIN - REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL <br />-REFER TO MECHANICAL DRAWING FOR ADDITIONAL INFORMATION INFORMATION <br />- -- — — — — REMOVED AND REUSED. — — — — — — DETERMINED BY ARCHITECT <br />- • •- - A EXISTING BOOM LIGHT TO BE <br />EXISTING , . — _ 0 -INSTALL IN SAME LOCATION. - - <br />" ; ,—�-- - - NEW PAINT FINSH -COLOR TO BE <br />_ T <br />EXISTING - CEILING SHALL RECEIVE NEW PAINT <br />E I I I i AND PROTECT EXISTING MOUNTING EQUIPMENT AND E <br />EQUIPMENT <br />. BOO I ; <br />EQUIPMENT I -COVER A <br />S M, <br />, 18 R ,TO LOCATE CENTERLINE OF EXISTING BE I _ I DEVICES <br />` CENTERLINE WILL BOOM LIGHT PRIOR TO DEMO THIS <br />_ USED IN LAYOUT OF NEW CEILING. <br />, , <br />-== _ „ a rac h,st a cstgu re . <br />- , up <br />pa <br />WALL RATINGS. 510 Vonderbu 216 Brandon, <br />Florida 335111813.667.2340 <br />e <br />I - <br />s I,- <br />/, 4 9 <br />EXISTING / �I I IL' ,/ 4 11 I I I I EXISTING 2, CGDPA - FL # AA-26003049 <br />, <br />ANESTHESIA' ;�' DEMOLITION GENERAL NOTES ANESTHESIA= <br />BOOM, 1 HOUR FIRE <br />1. MINIMAL DEMOLITION TO EXISTING ARCHITECTURAL I BOOM' l <br />___$-S�S*S1 HOUR FIRE/ <br />SMOKE BARRIER <br />ELEMENTS DURING THIS EQUIPMENT CHANGE -OUT. <br />----— <br />2 2 HOUR FIRE XPU. S Services Inc.4 EXISTINGWA AND CEILING MOUNTED EQUIPMENT <br />CONTRACTOR HALL PROTECT AND COVER ALL <br />t: +1.407.660.0088 f: +1.407.660.1655 <br />I I �.g.�♦g��.� 2 HOUR FIRE/ SMOKE BARRIER <br />- — — ; 2601 Westhall Lane <br />\` J r AND DEVICES �-T_♦T TEMPORARY 1 HOUR FIRE Maitland, FL 32751 <br />I ; II I II 2 USA <br />� • - - ; I I I I ,_ , - ' / I, , , 1 , _ i (II 2 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING �� • <br />CONDITIONS PRIOR TO COMMENCING WORK. USE _ .exp.co • <br />I <br />' CARE NOT T DMA WALL AND CEILING MOUNTED � • , - - r - •� � <br />- \ ,, , - II I II - • :; . -• . , 1 .- , I II• r ,, , r, '- O O DAMAGE MOU ED 4 <br />i 1 I <br />., _ , / _ , , -, �,, , Project ect #: 2100505 <br />�I _ _ I:' DEVICES / EQUIPMENT DURING RELOCATION OF LIGHT u , Mi <br />�/ex <br />PARTITIONS: <br />Cert of Auth: 29701 <br />\,--_---- — — BOOM. I 1 P 0 S <br />3. LIGHT OR HALFTONE LINES INDICATE EXISTING TO — — — — — — T ; <br />•, , •_ ,- . •• �_ , ,- - _- - , ' REMAIN - - . - , <br />I I ti I EXISTING/REMAINING <br />2 <br />E TEMPORARY SC I TIONS FOR CUTTING, PATCHING g�_g�� q CCRUB NEW WORK <br />_ AIR / EXIT SIGN I _. AND DEMOLITION. <br />4 SEE SPECIFICA ,� <br />:FF <br />DEMOLISHED <br />5. DASHED BOLD LINES INDICATE EXTENT OF <br />' -ram - ', •• ._ - _ <br />` DEMOLITION INCLUDING THE FOLLOWING: CEILINGS <br />INCLUDING CEILING SUSPENSION SYSTEM & HANGERS <br />B5 (WHERE INDICATED ONLY AND/OR NEEDED FOR % <br />G-010 COMPLETION OF RELOCATING BOOM), MISC. STEEL <br />' (( STICKY MAT I SUSPENDED SUPPORTS OEQUIPMENT, LIGHTR SUSPENDED FIXTURES, DOORS <br />1 L AND FRAMES UNLESS NOTED OTHERWISE IN DOOR RCP SYMBOL LEGEND <br />D SCHEDULE. NOTIFY THE ARCHITECT OF ANY �A �:., �� D <br />t I Y C° DISCREPENCIES. t� I ^ ED <br />' RI-) I I,Y i D""`�FPROJECT FOR <br />i, 6. REMOVE FURRING OR GWB ONLY WHERE i ACOUSTICAL TILE CEILING (24X24) <br />REQUIRED TO COMPLETE CTION. PATCH <br />PROJECT LIMIT LINE AND MATCH WALLS ASREQUOREDTOCOMPLETE AND "/ PROJECT LIMIT LINE ADVENT HEALTH <br />MATCH EXISTING CONDITIONS, UNLESS AN - ACOUSTICAL TILE CEILING (24X48) Z E P H RYH I L LS <br />ALTERNATIVE MATERIAL AND FINISH IS INDICATED. <br />,r <br />7. SEE ROOM FINISH PLANS, MECHANICAL PLANS, <br />AND ELECTRICAL PLANS FOR EXTENT OF CEILING GYPSUM CEILING -PAINTED <br />ALTERATIONS OR CEILING PATCHING IN EXISTING <br />AREAS. <br />8. CONTRACTOR SHALL VERIFY FINISHES NOTED FOR I I FLUORESCENT LIGHT FIXTURE OPERATING ROOM <br />REMOVAL PRIOR TO COMMENCING WORK. TAKE INTO FLUORESCENT LIGHT FIXTURE 5 — CYSTOSCOPY <br />ACCOUNT ANY DISCREPANCIES AND MAKE PROPER <br />PHYSICIANS ADJUSTMENT TO ACCOMPLISH REQUIRED R. `� SICI NS <br />'( CONSTRUCTION & FINISHES. NOTIFY THE ARCHITECT( P INCANDESCENT LIGHT FIXTURE <br />PRIOR TO ANY STRUCTURAL ALTERATIONS. <br />_ E w;= COORDINATE PHASING WITH OWNER. I I�L E " <br />SMOKE DETECTOR <br />9. COORDINATE REMOVAL OF EXISTING EQUIPMENT <br />,H �`�l� , NS) WITH OWNER.PHYSICIANS ❑ SPEAKER <br />;..$r�aG gym, 7050 GALL BLVD. <br />1 10. REFER TO SC DU ES FOR NEW AND TEXISTING EQUIPMENT OR DRAWINGS AND I I ® EXIT LIGHT ZEPHYRH ILLS, FL 33541 <br />RELOCATIONS, ETC. � HVAC SUPPLY DIFFUSER <br />1 2 11. REMOVE CEILINGS ONLY AS REQUIRED FOR NEW 1 2 <br />CONSTRUCTION. REINSTALL, REPLACE OR PATCH AS HVAC RETURN DIFFUSER <br />REQUIRED. 71 <br />�1 PLAN - LEVEL 2 - RCP DEMO C3 PLAN - LEVEL 2 - RCP NEW WORK CEILING ACCESS PANEL <br />1/4 = 1 0 1/4 = 11-0" EZ <br />NOTE: REFER TO MECHANICAL FOR DIFFUSER <br />AND OTHER CEILING MOUNTED DEVISES. C Advirent <br />AHCA CLIENT CODE / FILE NUMBER: 231100046-127-1 <br />PROJECT LIMIT LINE PROJECT LIMIT LINE <br />DEMOLITION SYMBOLS I I RCP GENERAL NOTES <br />3 <br />_ I —T T— TEMPORARY SOUND/DUST CONTROL WALLS: I I 1. REFER TO MECHANICAL DRAWINGS FOR QUANTITY <br />_ TO BE OF 1 HR RATED CONSTRUCTION AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND <br />SIMILIAR TO U465. I I EXHAUST GRILLES. SCRIBE CEILING MATERIALS <br />IN CAREFULLY FOR A TIGHT FIT. <br />TEMPORARY VISQUEEN BARRIER I I I <br />2. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY <br />• • • 'D '*EGRESS ROUTE I AND TYPE OF LIGHTS, SPEAKERS, DETECTORS, 1 04/23/2021 AHCA COMMENTS 1 <br />S�STERILE Sit STEFI1LE POWER OUTLETS, ETC. SCRIBE CEILING MATERIALS <br />' ' • I I <br />CONTRACTOR ACCESS CAREFULLY. WHERE NO DEVICES ARE SHOWN ON MARK DATE DESCRIPTION <br />PLANS, FEILD VERIFY LOCATION & QUANTITY OF PROJECT NUMBER 042-21.177.01 <br />4) <br />EXIT SIGN I I DEVICES IN EXISTING CEILING. THESE DEVICES MAY <br />CYSTO \°' BE RELOCATED OR REINSTALLED. ORIGINAL ISSUE MARCH 11, 2021- <br />0.R.�5 2 <br />TEMPORARY FIRE EXISTING TO REMAIN 3. THE ENTIRE PROJECT HAS EXISTING FIRE PROJECT MANAGER TEC <br />I �l� <br />EXTINGUISHER I SPRINKLER HEADS IN CEILING. SCRIBE CEILING PROJECT DESIGNER n/a <br />I MATERIALS CAREFULLY FOR A TIGHT FIT. <br />PROJECT ARCHITECT THOMAS E. CHAPUIS AR 97109 <br />I I NOTE: I I 4. ALL EXISTING TO REMAIN GRILLES, DIFFUSERS AND g <br />B / TEMPORARY SOUND/DUST CONTROL DOOR(S). LIGHTS ETC. WITHIN SCOPE OF PROJECT TO BE LANDSCAPE ARCHITECT n/a <br />- HARDWARE TO BE 1 HR RATED I I CLEANED. CIVIL ENGINEER n/a <br />- POSITIVE LATCH SET., <br />STRUCTURAL ENGINEER n/a <br />- SOLD CORE DOOR LEAF 45 MINS <br />j — / — — � — — — — � — — — — � — — — � — — MECHANICAL ENGINEER TIMOTHY P. PENNOCK PE 54516 <br />— 3 —C�) O ELECTRICAL ENGINEER CHARLES T. ALEXANDER PE 76422 <br />INTERIOR DESIGNER CDG ARCHITECTURE <br />NEG SCRUB; <br />II EQUIPMENT PLANNER n/a <br />DEMOLITION KEYED NOTES- - - - - <br />DRAWN BY SO <br />OO <br />\— C <br />G-010 EQUIPMENT PATH: <br />T T T—J I O -EQUIPMENT ON -SITE <br />I � STICKY MAT I -COORDINATED PATH WITH FACILITY AND EQUIPMENT I I •' <br />VENDOR FOR INSTALLATION. <br />— 18 _ *� 0 — 0 — I* _ RE S ICTED TEMPORARILY REMOVE EXISTING CEILING MOUNTED :ES 'ILCTED <br />o I 2 EQUIPMENT FOR RELOCATION OF LIGHT BOOM, PATCH AND I r I , F <br />= C RIDOR O REPAIR TO MATCH AND PREPARE AREA TO RECEIVE NEW 01, <br />SCHEDULED FINISHES. • <br />PROJECT LIMIT LINE 3 EXISTING FLOORING TO REMAIN. PATCH AND REPAIR <br />PROJECT LIMIT LINE <br />O AS REQUIRED. <br />I I I I <br />PLANS - DEMO, NEW <br />PHYSICIANS WORK RCP <br />A OFF CE LOUNGE OFF � . <br />A <br />�, y <br />r <br />kEEP I � aLEE <br />i <br />PHYSICIANS PHYSIC._ <br />LOUNGE I I CUNGE I PROJECT <br />JSCALE As indicated <br />r NORTH <br />PLAN - LEVEL 2 - DEMO PLAN - LEVEL 2 - NEW WORK <br />Aml01 <br />5 N A l 1 /4" = 1'4' 1 /4" = V-0" <br />1 2 3 4 5 6 CONTRACT DOCUMENTS <br />