My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (107)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (107)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:13:51 AM
Creation date
2/18/2025 4:38:50 PM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Berglund Construction Company
Building Plans - Permit #
2203
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 3 4 5 6 <br />ABBREVIATIONS GENERAL DRAWING NOTES DIMENSIONING: ARCHITECTURAL SYMBOLS PROJECT NARRATIVE <br />AB ANCHOR BOLT G GAS QT QUARRY TILE A. THESE ABBREVIATIONS APPLY TO THE ENTIRE SET OF CONTRACT 1. DIMENSIONS ARE INDICATED TO THE CENETRLINE OF THE THE PROJECT IS A SINGLE PHASE PROJECT WHICH DOES NOT INCLUDE WALL <br />ABS AIR BREAK SWITCH GA GAGE QTY QUANTITY DRAWINGS. STRUCTURAL GRID, FACE OF CONCRETE WALL, NOMINAL COLUMN GRID LINE <br />AC ACRE GAL GALVANIZED QUAL QUALIFICATION FACE OF CMU WALL, FACE OF PARTITION AS SCHEDULED, (EXISTING) DEMOLITION, ONLY MINOR CEILING DEMOLITION AND REWORK FOR NEW <br />LIGHTING AND CYSTOA/C AIR CONDITIONING GB GRAB BAR B. LISTING OF ABBREVIATIONS DOES NOT IMPLY ALL ABBREVIATIONS ARE UNLESS OTHERWISE NOTED. RATING BED INSTALLATION AND CONTROL TABLE IN . <br />ACC ACCESSIBLE GC GENERAL CONTRACTOR R RISER USED IN THE CONTRACT DRAWINGS. <br />COLUMN GRID LINE EXISTING OPERATING ROOM #5. NO STRUCTURAL WORK IN SCOPE. <br />ACOUS ACOUSTIC GDRL GUARD RAIL RA RETURN AIR 2. ALIGNMENT OF PARTITIONS AND FINISHES AS (NEW) <br />ACT ACOUSTICAL CEILING TILE GEN GENERATOR RAID RADIUS C. ABBREVIATIONS SHOWN ON THIS SHEET INCLUDE ALL VARIATIONS OF SCHEDULED SHALL BE STRAIGHT, TRUE & PLAUMB. _ <br />AD ACCESS DOOR GFCI GROUND FAULT CIRCUIT INTERRUPTER RB RESILIENT BASE THE DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING CENTER LINE <br />ADA AMERICANS WITH DISABILITIES ACT GFMU GROUND FACE MASONRY UNIT RCP REFLECTED CEILING PLAN WORD. (FOR EXAMPLE, "DEMO" CAN MEAN DEMOLISH OR DEMOLITION; PRIORITY ORDER. <br />ADJ ADJUSTABLE GL GLASS RD ROOF DRAIN "IN" a. STRUCTURAL DRAWINGS „ DIMENSION LINE TO <br />ADJC ADJACENT GR GRADE RECP RECEPTACLE CAN MEAN INCH OR INCHES; "REINF" CAN MEAN REINFORCE OR b. LARGE SCALE DETAILS 7 - 0 FACE OF STUD, FACE <br />AFF ABOVE FINISHED FLOOR GRID GROUND REF REFRIGERATOR REINFORCING.) c. SMALL SCALE DETAILS OF CONCRETE, <br />AHU AIR HANDLING UNIT GSU GLAZED STRUCTURAL UNIT REINF REINFORCED / REINFORCEMENT d. ENLARGED PLANS AND SECTIONS COLUMN LINE, OR AS <br />E ALT ALTERNATE GW GROUND WATER REG REGISTER D. SCREENING OR SHADING OF WORK IS USED TO INDICATE EXISTING e. FLOOR PLANS NOTED. E <br />AL ALUMINUM GWB GYPSUM WALL BOARD REM REMOVABLE CONDITIONS OR TO DE-EMPHASIZE PROPOSED IMPROVEMENTS TO Ii 7'-0" �I <br />AM ACOUSTIC MATERIAL GYP GYPSUM REQD REQUIRED HIGHLIGHTED SELECTED TRADE WORK. REFER TO CONTEXT OF EACH 3. MINIMUM DIMESIONS FOR ACCESSIBILITY CLEARANCES DIMENSION TO FINISH <br />AMP AMPERE RESIL RESILIENT DRAWING FOR USAGE. AND BUILDING CODE REQUIREMENTS SHALL BE FACE, COUNTERTOP chapuis design group <br />ANO ANODIZED H HIGH REV REVISION MAINTAINED. NOTED. CLEAR, OR AS GENERAL INFORMATION architecture . p a <br />AP ACCESS PANEL HB HOSE BIBB RF RETURN FAN E. SEE PROJECT EQUIPMENT AND MEP SYSTEMS DRAWINGS FOR <br />APPROX APPROXIMATE HC HOLLOW CORE RFG ROOFING SYMBOLS 4. FLOOR ELEVATIONS ARE INDIACTED AT THE FACE OF WALL LEGEND 510 Vonderburg Drive i Suite 216 Brandon, <br />ARCH ARCHITECT, ARCHITECTURAL HD HOT DIP RG RETURN GRILLE AND ABBREVIATIONS SPECIFIC TO THE PROJECT. STRUCTURAL SLAB, UNLESS OTHERWISE NOTED. Florida 33511 i 813.667.2340 <br />EXISTING TO ARR ARRESTOR HDO HIGH -DENSITY OVERLAY PLYWOOD RH RIGHT HAND 5. VERTICAL DIMESIONS ARE INDICATED FROM THE FLOOR �� EXISTING TO BEMAIN PROJECT ADDRESS: <br />ASPH ASPHALT HDRL HANDRAIL RHR RIGHT HAND REVERSE F. TYPICAL OR TYP INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CGDPA - FL # AA-26003049 <br />HDW HARDWARE RL RAIN LEADER CONDITION NOTED. ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS f REMOVED <br />B BASELINE HDWD HARDWOOD RM ROOM NOTED ABOVE FINISH FLOOR - "AFF". I ( EXISTING TO REMAIN 7050 GALL BLVD. <br />BD BOARD HEB HARDWOOD EDGEBANDING RO ROUGH OPENING G. "SIMILAR" OR "SIM" INDICATES COMPLETE SYSTEM AND COMPONENTS NEW CONSTRUCTION ZEPHYRHILLS, FL 33541 <br />BEJ BRICK EXPANSION JOINT HGT HEIGHT RPM REVOLUTIONS PER MINUTE COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 6. CEILING HEIGHTS ARE INDIACTED FROM THE FLOOR <br />BLDG BUILDING HID HIGH INTENSITY DISCHARGE RV ROOF VENT ELEVATION TO FACE OF SUSPENDED ACOUSTIC CEILING ROOM TAG exp U.S. Services Inc. <br />BLKG BLOCKING HM HOLLOW METAL H. "AS REQUIRED" OR "AS REQD" INDICATES CONTRACTOR SHALL PROVIDE GRID OR FACE OF FINSIH MATERIAL FOR OTHER CEILING ROOM NAME SITE WORK / PARKING: <br />BM BEAM HO HOLD OPEN S SOUTH COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS TYPES, UNLESS OTHERWISE NOTED. t: +1.407.660.0088 f: +1.407.660.1655 <br />0 ROOM NUMBER 2601 Westhall Lane <br />BO BOTTOM OF HORIZ HORIZONTAL SA SUPPLY AIR INDICATED IN THE PROJECT DOCUMENTS. 7. IN MANY OF THE INTERIOR SPACES THE ACTUAL ? AREA OR VOLUME NO SITE WORK IS INCLUDED ON THIS PROJECT. Maitland, FL 32751 <br />BOB BOTTOM OF BEAM HP HIGH POINT SAB SOUND ATTENUATION BATT <br />BOF BOTTOM OF FOOTING HIPS HIGH PRESSURE SODIUM SAN SANITARY 1. "ALIGN" INDICATES CONTRACTOR SHALL ACCURATELY PROVIDE FINISH DIMENSIONS MAY BE LESS CRITICAL THAN IF TWO 18" N USA �: <br />BOS BOTTOM OF STEEL/STRUCTURE HR HOUR SC SOLID CORE FACES OF MATERIALS IN STRAIGHT TRUE AND PLUMB RELATION TO ELEMENTS IN THE BUILDING WERE TO BE EQUAL IN THESE I www.exp.com 0V <br />54 <br />BR BOTTOM HSK HOUSEKEEPING SCH BOTTOM REGISTER HVAC HEATING, VENTILATION AND AIR CONDITIONING SCRN SCREEN THE ADJACENT MATERIALS AS NOTED. CASES, THE WORD "EQUAL" OR "EQ" IS USED IN LIEU OF J SYOOR NUMBER Project #: MBOL AND MINIMUM OCCUPANCY CLASSIFICATION: Certof Auth. 2s 01ex THE ACTUAL DIMESION. 0 <br />BRG BEARING HW HOT WATER SD SOAP DISPENSER CLEARANCES <br />BSMT BASEMENT HZ HERTZ SE SOUTHEAST 8. WHEN A ROOM CENTERLINE IS INDICATED ONLY ONE 12" MIN 4" MIN 1-2 - HEALTHCARE <br />SECT SECTION SIDE OF THE ROOMS ELEMENTS MAY BE DIMENSIONED. <br />C CELSIUS ID INSIDE CAB CABINET IF INSIDE FFACEETER SF SGL SINGLE E FOOT /SQUARE FEET MATERIALS LEGEND WALL TYPE TAG <br />9. Ca. PARTITION C NEITO RED ON COLUMNOR STRUCTURAL SYSTEM: <br />CAP CAPACITY IN INCH /INCHES SH SHEET <br />CB CIRCUIT BREAKER INT INTERIOR SHR SHOWER GRID LINES WILL NOT BE DIMESIONED ON FRAME TYPE - <br />CEM CEMENT INSUL INSULATION SHV SHELF / SHELVING SMALL SCALE DRAWINGS BUT WILL BE EXTERIOR & LOUVER EXISTING STRUCTURE TO REMAIN <br />CFCI CONTRACTOR FURNISHED / CONTRACTOR INSTALLED INV INVERT SIM SIMILAR DRAWN ACCORDINGLY, <br />CFMF COLD -FORMED METAL FRAMING SK SINK b CONCRETE (SECTION) COLUMN CENTERLINE O FRAME TYPE -INTERIOR <br />CFOI CONTRACTOR FURNISHED / OWNER INSTALLED JAN JANITOR SL SLOPE <br />CG CORNER GUARD JB JUNCTION BOX SLV SLEEVE <br />C&G CURB AND GUTTER JC JANITOR CLOSET SND SANITARY NAPKIN DISPENSER BUILDING DATA AND AREAS: <br />CH CHILLER JCT JUNCTION SNR SANITARY NAPKIN RECEPTACLE GRANULAR FILL CURTAIN PANEL TYPE <br />PARTITION <br />CHAN CHANNEL JT JOINT SPEC SPECIFICATION P�6� � RENOVATION AREA OF WORK D <br />D Cl CAST IRON JST JOIST SPRINK SPRINKLER <br />CIP CAST IN PLACE SQ SQUARE -OPERATING ROOM #5 = 429.41 SF <br />CIR CIRCULATING K KILO SS STAINLESS STEEL CONCRETE MASONRY UNITS b. PARTITION WITH A FINISHED FACE FLUSH DRAWING REVISION <br />CJ CONTROL JOINT KG KILOGRAM ST STREET WITH FINISH FACE OF COLUMN WILL NOT BE PROJECT FOR <br />CKT CIRCUIT KIT KITCHEN STA STATION DIMSIONED ON SMALL SCALE DRWAINGS OCCUPANCY GROUPS GROUP 1-2; HEALTHCARE <br />CLG CEILING KO KNOCK OUT STC SOUND TRANSMISSION CLASS BUT WILL BE DRAWN ACCORDINGLY. 0 ?? O KEYNOTE ADVENT HEALTH - <br />BRICK TYPE OF CONSTRUCTION FBC TYPE I-B, Z E P H RYH I L L <br />CLR CLEAR KP KICK PLATE STD STANDARD NFPA 220 TYPE II (000) S <br />CM CONSTRUCTION MANAGER KV KILOVOLT STL STEEL <br />CMU CONCRETE MASONRY UNIT KW KILOWATT STOR STORAGE NORTH ARROW <br />CNDS CONDENSATE STRUCT STRUCTURE / STRUCTURAL RIGID INSULATION (SECTION) SPRINKLERS FULLY SPRINKELED <br />CO CLEANOUT L LENGTH/LONG SUP SUPPORT LiffiffiffiH <br />COL COLUMN LAB LABORATORY SUSP SUSPENDED <br />COLUMN CENTERLINE LEVEL DATUM HEIGHT 2 STORY <br />COMM COMMUNICATION LAD LADDER SW SOUTHWEST ACOUSTIC/THERMAL �/ LEVEL NAME <br />CONC CONCRETE LAM LAMINATED /LAMINATION SYM SYMBOL COND CONDUCTOR LAV LAVATORY SYS SYSTEM LEVEL ELEVATION INSULATION (SECTION)OPERATING ROOM <br />CONN CONNECTION LB POUND <br />CONST CONSTRUCTION LCC LEAD COATED COPPER T TREAD PARTITION 5 CYSTOSCOPY <br />CONT CONTINUOUS LF LINEAR FOOT TB TACK BOARD STUD WALL (PLAN & SECTION) <br />CONTR CONTRACTOR LH LEFT HAND T&B TOP AND BOTTOM ? DET IL SECTION <br />POSITION ON SHEET <br />CONV CONVERTER LHR LEFT HAND REVERSE TEL TELEPHONE _77] <br />SHEET NUMBER <br />COORD COORDINATE LIN LINEAR TEMP TEMPORARY EXISTING WALL TO REMAIN c. PARTITION FINISH FACE ON COLUMN OR CODES AND STANDARDS: <br />COP COPPER LL LIVE LOAD TERR TERRAZZO (PLAN & SECTION) GRID LINE WILL NOT BE DIMESIONED ON ! 1 ? ? DETAIL - PLAN <br />CORR CORRIDOR LLH LONG LEG HORIZONTAL T&G TONGUE AND GROOVE — - SMALL SCALE DRWAINGS BUT WILL BE POSITION ON SHEET <br />CPT CARPET LLV LONG LEG VERTICAL 3 WAY THREE WAY — — DRWAN ACCORDINGLY. ? <br />CR CRASH RAIL LNTL LINTEL TH THICK DEMOLISHED WALL J SHEET NUMBER ALL WORK PERTAINING TO AND ALL MATERIALS SUPPLIED FOR <br />CS CONCRETE SEALER/SURFACE LONG LONGITUDINAL THRES THRESHOLD _ _ (PLAN & SECTION) COLUMN CENTERLINE EXECUTING AND COMPLETING THIS CONTRACT SHALL COMPLY WITH 7050 GALL BLVD. <br />CSK COUNTERSUNK LP LOW POINT THRU THROUGH PROVISIONS SPECIFIED IN THE CONTRACT DOCUMENTS AND WITH <br />CSWK CASEWORK LT LIGHT TMPD TEMPERED 0- — — — BUILDING SECTION APPLICABLE LAWS, REGULATIONS, AND ORDINANCES GOVERNING WORK ZEPHYRHILLS, FL 33541 <br />CT CERAMIC TILE LTG LIGHTING TO TOP OF STEEL (SECTION) POSITION ON SHEET INCLUDING, BUT NOT NECESSARILY LIMITED TO THOSE OF THE <br />CTR CENTER LTWT LIGHTWEIGHT TOB TOP OF BEAM PARTITION SHEET NUMBER FOLLOWING: <br />CW COLD WATER LVR LOUVER TOC TABLE OF CONTENTS <br />CWB CAPILLARY WATER BARRIER TOF TOP OF FOOTING FLORIDA BUILDING CODE, 7TH EDITION (2020) - BUILDING <br />CYL CYLINDER M METER TOL TOLERANCE ALUMINUM (SECTION) 10.OPENINGS OCCURING IN PARTITIONS OR WALLS. WALL SECTION FLORIDA BUILDING CODE, 7TH EDITION (2020) - EXISTING BUILDING <br />MACH MACHINE TOP TOP OF PAVING FLORIDA BUILDING CODE, 7TH EDITION (2020) - ACCESSIBILITY <br />D DEEP MAINT MAINTENANCE TOS TOP OF STEEL / STRUCTURE / SLAB a. WHEN ONE JAMB OCCURS AT A COLUMN OR POSITION ON SHEET FLORIDA BUILDING CODE, 7TH EDITION (2020) - TEST PROTOCOLS <br />GRID LINE NO DIMESIONS WILL BE SHOWN — — SHEET NUMBER FLORIDA BUILDING CODE 7TH EDITION (2020 MECHANICAL <br />DB DECIBEL MANUF MANUFACTURER TOW TOP OF WALL WOOD FINISH (SECTION) � ) - <br />DBL DOUBLE MAS MASONRY TRANS TRANSITION ( ON THE SMALL SCALE DRAWINGS. THE FLORIDA BUILDING CODE, 7TH EDITION (2020) - PLUMBING <br />DEG DEGREE MATL MATERIAL TSTAT THERMOSTAT OPENING WIDTH WILL BE GOVERNED BY X FLORIDA BUILDING CODE, 7TH EDITION (2020) - FUEL GAS • <br />DEMO DEMOLISH / DEMOLITION MAX MAXIMUM TV TELEVISION DESIGN CRITERIA OR SCHEDULE. EXTERIOR ELEVATION <br />C DIET DETAIL MB MARKER BOARD TYP TYPICAL 1><1DIMENSIONAL LUMBER CONTINUOUS (SECTION) ADDITIONAL STANDARDS: C Ad,% <br />DF DRINKING FOUNTAIN MDF MEDIUM -DENSITY FIBERBOARD b. WHEN NEITHER JAMB OCCURS AT A COLUMN OR X-XXX POSITION ON SHEET ADDITIONAL DESIGN REQUIREMENTS ARE INCORPORATED N E MEDIUM -DENS OARD G QU O ED BY REFER C nt Health <br />DIA DIAMETER MDO MEDIUM -DENSITY OVERLAY PLYWOOD UC UNDER CABINET GRID LINE THEN ONE JAMB WILL BE SHEET NUMBER IN SPECIAL OCCUPANCY CHAPTERS OF THE FLORIDA BUILDING CODE TO <br />DIFF DIFFUSER MECH MECHANICAL UG UNDERGROUND DIMESIONED. X INCLUDE THE FOLLOWING: <br />DIM DIMENSION IVIED MEDIUM LINO UNLESS NOTED OTHERWISE DIMENSIONAL LUMBER BLOCKING (SECTION) <br />DL DEAD LOAD MEMB MEMBRANE UPS UNINTERRUPTIBLE POWER SUPPLY 11. DOOR LOCATION INTERIOR ELEVATION GUIDELINES FOR THE DESIGN AND CONSTUCTION OF HEALTH CARE <br />DMPR DAMPER MEP MECHANICAL, ELECTRICAL AND PLUMBING UR URINAL FACILITIES, 2018 EDITION AHCA CLIENT CODE I FILE NUMBER: 23/100046-127-1 <br />DOORS ARE LOACTED BY ONE OF THE FOLLOWING: X X-XXX X POSITION ON SHEET <br />DN DOWN MET METAL UV ULTRAVIOLET UL STANDRD 181 (1996) <br />LUMBER FINISH (SECTION) SHEET NUMBER <br />DP DISTRIBUTION PANEL MEZZ MEZZANINE a. ONE JAMB FACE LOCATED BY A PARTITION AT ASTM E (2005) <br />DS DOWNSPOUT MH MANHOLE V VENT X • ASCE 7 (2010 ) <br />DW DOMESTIC WATER MIN MINIMUM, MINUTE VAC VACUUM RIGHT ANGLE. TYPICAL UNLESS INDICATED ON ANSI /AHSRAE/ASHE STANDARD 170 (2008) <br />DWG DRAWING MIR MIRROR VCT VINYL COMPOSITION TILE — EARTHWORK (SECTION) PLAN. VIEW TITLE UL STANDARD 1069, 7TH EDITION (2007) <br />MISC MISCELLANEOUS VENT VENTILATING / VENTILATION — DRAWING NUMBER <br />E EAST MLWK MILLWORK VERT VERTICAL % CENTER FOR MEDICARE / MEDICADE SERVICES (CMS) <br />EA EACH MM MILLIMETER VEST VESTIBULE PARTITION <br />? DRAWING SCALE NFPA 101 LIFE SAFETY 2015 EDITION <br />EB EDGEBANDING MO MASONRY OPENING VIF VERIFY IN FIELD FFPC, 6TH EDITION (2017) <br />EG EXHAUST GRILLE MTD MOUNTED RESONANCE IMAGING VSR VENT STACK LINE TYPE LEGEND DOOR VIEW TITLE W/ REF. FLORIDA STATE FIRE CODES: <br />EIFS EXTERIOR INSULATION FINISHING SYSTEM MTG MOUNTING VTR VENT THRU ROOF DRAWING NUMBER STATE FIRE MARSHAL'S RULE 69A-3.012 F.A.0 (WITH ALL <br />EJ EXPANSION JOINT MULL MULLION VWC VINYL WALL COVERING — HIDDEN /BELOW 4" MIN. REFERENCED SUB CHAPTERS) <br />EL ELEVATION — — ? ? ? DRAWING SCALE FLORIDA FIRE PREVENTION CODE 61 H EDITION (FFPC) AND ALL <br />ELEC ELECTRIC / ELECTRICAL N NORTH, NITROGEN W WEST, WIDE _ REFERENCED PUBLICATIONS <br />— — — — _ — — — <br />ELEV ELEVATOR NA NOT APPLICABLE WA WATT OVERHEAD SHEET NUMBER <br />EMER EMERGENCY NAT NATURAL W/ WITH REFERENCING <br />-- EMI ELECTROMAGNETIC INTERFERENCE NE NORTHEAST W/O WITHOUT NOT IN CONTRACT (EQUIPMENT b. AS DIMENSIONED ON PLAN. SHEET NUMBER <br />/FURNITURE) <br />ENG ENGINEER NEUT NEUTRAL WC WATER CLOSET 12. DIMSENIONS ARE INDICATED. DO NOT SCALE DRAWINGS <br />EOP EDGE OF PAVEMENT NIC NOT IN CONTRACT WD WOOD PROPERTY LINE 0 4'-0" 8'-0" 16'-0" <br />EOS EDGE OF SLAB NO NUMBER WDW WINDOW FOR DIMENSIONS. GRAPHIC SCALE <br />EP ELECTRIC PANEL NOM NOMINAL WLD WELDED LIMIT OF WORK MARK DATE DESCRIPTION <br />EPDM ETHYLENE PROPYLENE DIENE MONOMER NRC NOISE REDUCTION COEFFICIENT WOM WALK OFF MATT <br />EQ EQUAL NTS NOT TO SCALE WP WORK POINT BREAK LINE PROJECT NUMBER 042.21.177.01 <br />EQUIP EQUIPMENT NW NORTHWEST WPFG WATERPROOFING MATCH LINE ORIGINAL ISSUE MAY 05, 2021- <br />ESC ESCALATOR WS WASTE STACK <br />ESMT EASEMENT O OXYGEN WSCT WAINSCOT <br />PROJECT MANAGER <br />EVAP EVAPORATIVE OA OUTSIDE AIR WT WEIGHT <br />EW EACH WAY OC ON CENTER WWF WELDED WIRE FABRIC PROJECT DESIGNER n/a <br />EWC ELECTRIC <br />EXH EXHAUST WATER COOLER OF OUTSIDE ACE OUTSIDE TER XFMR TRANSFORMER DOOR LEGEND PROJECT ARCHITECT THOMAS E. CHAPUIS AR 97109 <br />B EXIST EXISTING OFCI OWNER FURNISHED/CONTRACTOR INSTALLED XPS EXTRUDED POLYSTYRENE FOAM B LANDSCAPE ARCHITECT n/a <br />EXP EXPANSION OFF OFFICE CIVIL ENGINEER n/a <br />EXT EXTERIOR OFOI OWNER FURNISHED/OWNER INSTALLED & AND <br />OH OPPOSITE HAND @ AT STRUCTURAL ENGINEER n/a <br />FA FIRE ALARM OPNG OPENING CENTER LINE TYPICAL DOOR WITH MECHANICAL ENGINEER TIMOTHY P. PENNOCK PE 54516 <br />FABX FIRE ALARM BOX OPP OPPOSITE 0 DIAMETER DOOR FULL -SWING <br />FACP FIRE ALARM CONTROL PANEL OH OVERHEAD ± PLUS OR MINUS F"-,YL HINGE ELECTRICAL ENGINEER CHARLES T. ALEXANDER PE 76422 <br />FCC FIRE COMMAND CENTER # POUND <br />FCU FAN COIL UNIT PART PARTIAL PINTERIOR DESIGNER CDG ARCHITECTURE <br />AIR DOOR PAIR DOOR - <br />FD FLOOR DRAIN PB PANIC BAR UNEVEN LEAF EQUIPMENT PLANNER n/a <br />FDC FIRE DEPARTMENT CONNECTION PERF PERFORATED <br />FDN FOUNDATION PERIM PERIMETER <br />DRAWN BY MM, SO <br />FE FIRE EXTINGUISHER PERP PERPENDICULAR <br />FEC FIRE EXTINGUISHER CABINET Pi PRECAST JOINT DOUBLE DOUBLE <br />FF FINISH FLOOR PL PLATE ACTING DOOR EGRESS <br />F/F FACE TO FACE PLAM PLASTIC LAMINATE <br />DOOR <br />FFE FINISHED FLOOR ELEVATION PUS PLASTER <br />FH FIRE HYDRANT PLBG PLUMBING BI-FOLD DOOR SLIDING <br />FHC FIRE HOSE CABINET PLYWD PLYWOOD DOOR <br />FIG FIGURE PNL PANEL <br />FIN FINISH PNT PAINT r— <br />FJ FELT JOINT PNTD PAINTED <br />FL FLASHING POLY POLYETHYLENE OVERHEAD CASED <br />FLR FLOOR PR PAIR ROLLING OPENING <br />FLUOR FLUORESCENT PRCST PRECAST DOOR <br />FOC FACE OF CONCRETE PREFAB PREFABRICATED <br />FOF FACE OF FINISH PRELIM PRELIMINARY EXISTING DUTCH DOOR <br />FOM FACE OF MASONRY PRESS PRESSURE DOOR <br />FOS FACE OF STUD PRIM PRIMARY <br />FOW FACE OF WALL PT POINT <br />FP FILLER PANEL PTD PAPER TOWEL DISPENSER <br />FPH FROST PROOF HYDRANT PTN PARTITION <br />FIR FRAME PVC POLYVINYL CHLORIDE CODE SUMMARY, <br />FS FULL SIZE PVG PAVING <br />FSTP FIRESTOPPING ABBREVIATIONS A N D <br />FT FOOT /FEET <br />FTG FOOTING <br />FURN FURNITURE <br />A FURR FURRING <br />A SYMBOLS <br />FV FIELD VERIFY <br />FVC FIRE VALVE CABINET <br />FXTR FIXTURE <br />SCALE As indicated <br />1 <br />2 <br />N <br />4 <br />5 <br />G=001 <br />6 CONTRACT DOCUMENTS <br />
The URL can be used to link to this page
Your browser does not support the video tag.