A. GENERAL <br />I. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE GOVERNING BUILDING CODES, <br />GOVERNING CODES LISTED SHALL INCLUDE ALL AMENDMENTS AND ADDENDA THAT WERE <br />ADOPTED BY FEDERAL, STATE, AND LOCAL MUNICIPALITIES AT THE DATE OF THE CONTRACTING <br />DOCUMENTS WERE ISSUED. <br />2020 EDITION OF THE INTERNATIONAL BUILDING CODE <br />2. WHERE CONFLICT EXISTS AMONG THE VARIOUS PARTS OF THE STRUCTURALLY AND ARCHITECTURAL <br />CONTRACT DOCUMENTS, THE STRICTEST REQUIREMENTS SHALL GOVERN. <br />3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE WORK SITE. <br />CONTRACTOR SHALL REPORT ANY DISCREPANCIES OR INCONSISTENCIES FROM THE ASSUMED <br />CONDITIONS TO THE ARCHITECT OF RECORD PRIOR TO FABRICATION AND CONSTRUCTION. <br />4. NOTES AND DETAILS SHOWN ON THE PLANS SUPERCEDE GENERAL NOTES. <br />DETAILS LABELED AS "TYPICAL" ON THE DRAWINGS SHALL APPLY TO ALL SITUATIONS OCCURRING <br />ON THE PROJECT THAT ARE THE OF SIMILAR CONDITION. <br />5. DO NOT SCALE DRAWINGS. CONTROLLING DIMENSIONS ARE PROVIDED BY ARCHITECT. <br />fo. GENERAL CONTRACTOR SHALL COMPARE THE ARCHITECTURAL AND STRUCTURAL DRAWINGS AND <br />REPORT ANY DISCREPANCIES BETWEEN EACH DISCIPLINE. ALL KNOWN DISCREPANCIES SHALL BE <br />RESOLVED WITH DIRECTION FROM THE ENGINEER OF RECORD PRIOR TO FABRICATION, CASTING, <br />AND ERECTION OF ANY STRUCTURAL MEMBERS. <br />1. GENERAL CONTRACTOR SHALL OBTAIN ALL CONTRACT DOCUMENTS AND LATEST ADDENDA AND <br />SUBMIT SUCH DOCUMENTS TO ALL SUBCONTRACTORS AND MATERIAL SUPPLIERS PRIOR TO THE <br />SUBMITTAL OF SHOP DRAWINGS, FABRICATION OF ANY STRUCTURAL MEMBER. <br />8. GENERAL CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT AND BRACE <br />THE STRUCTURE DURING CONSTRUCTION. LATERAL BRACING PROVIDED IN THE CONTRACT <br />DOCUMENTS IS BASED ON THE COMPLETED DESIGN IN ITS ENTIRETY. <br />5. CONTRACT DOCUMENTS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. <br />PROCEDURES, TECHNIQUES, MEANS AND METHODS OF CONSTRUCTION ARE THE RESPONSIBILITY OF <br />THE GENERAL CONTRACTOR AND SUBCONTRACTORS. <br />10. PERIODIC SITE OBSERVATIONS BY THE ENGINEER OF RECORD MAY BE PERFORMED TO ASSES THE <br />PROGRESS AND CONFORMANCE OF CONSTRUCTION TO THE CONTRACT DOCUMENTS. SITE VISITS <br />ARE LIMITED TO THE EXTENTS OF THE ITEMS OBSERVED AND DO NOT REPRESENT AN EXHAUSTIVE <br />OR CONTINUOUS OBSERVATION FOR THE QUALITY OF WORK. <br />II. GENERAL CONTRACTOR SHALL INFORM THE STRUCTURAL ENGINEER OF RECORD WHENEVER <br />PENETRATIONS AND OPENINGS ARE REQUIRED THROUGH A STRUCTURAL MEMBER. DO NOT <br />PENETRATE, NOTCH, AND FIELD MODIFY, ETC. ANY STRUCTURAL MEMBER WITHOUT WRITTEN <br />PERMISSION. <br />12. GENERAL CONTRACTOR SHALL COORDINATE CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL <br />DISCIPLINES FOR ANY CONFLICTS WITH STRUCTURAL DRAWINGS. <br />B. DESIGN CRITERIA <br />I. DEAD LOAD MATERIALS ASSUMED IN THE DESIGN ARE SHOWN ON THE ARCHITECTURAL AND <br />STRUCTURAL DRAWINGS. <br />2. LIVE LOADS: <br />3. AN ADDITIONAL 15 PSF PARTITION LOAD SHALL BE INCLUDED WITH ANY LIVE LOAD LESS THAN 80 PSF <br />AND IN AN AREA SUBJECT TO FUTURE CHANGES. <br />LOCATION UNIFORM LOAD (PSF) CONCENTRATED LOADS(#) <br />GARAGE 40 <br />LOBBIES AND FIRST FLOOR CORRIDORS 100 <br />OFFICE 50 <br />ROOF 10 <br />STAIRS AND EXITS 100 <br />LIGHT STORAGE 125 <br />4. WIND LOADS <br />ULTIMATE WIND SPEED <br />131 MPH (3-5EC GUST) <br />NOMINAL WIND SAPPED <br />166 MPH (3-SEC GUST) <br />RISK CATEGORY <br />II <br />.EXPOSURE CATEGORY <br />B <br />INTERNAL PRESSURE COEFF. <br />+l- 6.18 <br />COMPONENTS AND CLADDING <br />SEE DIAGRAM <br />SEISMIC LOADS <br />SEISMIC IMPORTANCE FACTOR <br />MAPPED SPECTRAL RESPONSE ACCELERATIONS <br />SITE CLASS <br />SPECTRAL RESPONSE COEFFICIENTS <br />SEISMIC DESIGN CATEGORY <br />BASIC SEISMIC FORCE RESISTING SYSTEM: <br />DESIGN BASE SHEAR <br />SPECTRAL RESPONSE COEFFICIENTS <br />RESPONSE MODIFICATION FACTOR <br />ANALYSIS PROCEDURE: <br />C. FOUNDATION <br />LE = 1.0 <br />SS =0.058 Sl =0.031 <br />D <br />SDS = 0.062 SDI =0.051 <br />D <br />LIGHT FRAMED WOOD SWATHED WITH WOOD STRUCTURAL PANELS <br />(VS = CS"W) <br />(CS = SDS/(R/LE)) CS=0.00095 <br />R =6 1/2 <br />EQUIVALENT LATERAL FORCE PROCEDURE <br />1. FOUNDATION DESIGN IS BASED THE ON THE MINIMUM ALLOWABLE BEARING PRESSURE ALLOWABLE PER THE ASCE <br />OF THE ADOPTED CITY AND STATE CODE <br />2. ALL RECOMMENDATIONS THEREIN THAT RELATED TO THE WORK SHOWN ON THESE DRAWINGS SHALL BE <br />FOLLOWED. <br />3. THE FOUNDATION SYSTEMS ARE DESIGNED BASED ON THE FOLLOWING CRITERIA CONTINGENT ON THE <br />BUILDING PAD PREPARATION RECOMMENDED IN THE ABOVE GEOTECHINCAL REPORT. <br />SPREAD FOOTINGS <br />TOTAL LOADING 1500 PSF <br />4. PRIOR TO PLACEMENT OF SLAB ON GRADE, THE EXPOSED SUBGRADE SHOULD BE REMOVED AS <br />NEEDED TO INSURE NO SOFT OR WET AREAS EXIST. IF WEAK SPOTS ARE ENCOUNTERED, THE AREA <br />SHOULD BE SCARIFIED A MINIMUM OF fo INCHES, THEN RE COMPACTED TO A MINIMUM -35% OF <br />STANDARD PROCTOR DENSITY AS DETERMINED BY THE ASTM D-698 PROCEDURE, AT OPTIMUM <br />MOISTURE CONTENT (0 TO +3%). <br />5. FOUNDATION SETTLEMENT IS ANTICIPATED THAT SPREAD FOOTINGS DESIGNED USING THE <br />RECOMMENDED ALLOWABLE BEARING CAPACITIES WILL EXPERIENCE DIFFERENTIAL SETTLEMENTS THAT <br />WILL BE WITHIN THE I INCH MAXIMUM THAT THIS TYPE OF STRUCTURE CAN TOLERATE. <br />D. SLAB ON GRADE FOUNDATION <br />1. GENERAL CONTRACTOR SHALL NOTIFY THE GEOTECHNICAL ENGINEER OR OTHER AUTHORIZED <br />INSPECTOR FOR REVIEW OF THE FOUNDATION BEARING SURFACE, INSPECTION OF FOUNDATION <br />INSTALLATION, AND PLACEMENT OF REINFORCING STEEL THE CONTRACTOR SHALL NOT PLACE <br />CONCRETE WITHOUT ENGINEER'S APPROVAL <br />2. GENERAL CONTRACTOR SHALL NOTIFY THE AUTHORIZED INSPECTOR 48 HOURS IN ADVANCE OF ANY <br />MAJOR FOUNDATION POURS. <br />3. FORM EXPOSED FACES OF GRADE BEAMS. <br />4. GRADE BEAM BOTTOM STEEL SHALL BE CHAIRED AT 5 FEET ON CENTER MAXIMUM SPACING. <br />5. GRADE BEAM BOTTOM STEEL REINFORCEMENT SHALL BE SPLICED OVER THE SUPPORTING <br />FOUNDATION ELEMENTS. GRADE BEAM TOP REINFORCEMENT SHALL BE SPLICED AT MID SPAN <br />BETWEEN SUPPORTING FOUNDATION ELEMENTS. <br />6. SLAB ON GRADE REINFORCING SHALL BE CHAIRED TO THE SPECIFIED HEIGHT TO PROVIDE A MINIMUM <br />CLEAR COVER TO GRADE AND MINIMUM COVER TO THE TOP SURFACE. <br />1. VAPOR BARRIER SHALL HAVE NO MORE THAN 0.01 PERMS AS TESTED BEFORE AND AFTER <br />MANDATORY CONDITIONING (ASTM E 1145 SECTION 1.1 AND SUB -PARAGRAPHS 1.1.2-5), MEET OR <br />EXCEED THE REQUIREMENTS OF ASTM E 1145 CLASS A AND BE NO LESS THAN 15 MILS THICK. <br />8. ALL VAPOR RETARDER/BARRIER SEAMS SHALL BE OVERLAPPED A MINIMUM OF 6 INCHES AND <br />TAPED WITH MANUFACTURER'S TAPE. ALL PENETRATIONS, BLOCK -OUTS, AND OPENINGS SHALL BE <br />SEALED USING A COMBINATION OF THE VAPOR BARRIER/RETARDER, MASTIC AND MANUFACTURER'S <br />TAPE. <br />S. THE CONTRACTOR SHALL PERFORM EXCAVATIONS, FOOTING CONSTRUCTION, AND PREPARATION OF <br />THE COMPACTED FILL UNDER THE STRUCTURE IN ACCORDANCE WITH RECOMMENDATIONS CONTAINED <br />IN THE GEOTECHNICAL REPORT. <br />le. EXCAVATIONS FOR FOUNDATIONS SHALL BE CLEANED AND HAND TAMPED TO A UNIFORM SURFACE. <br />FOOTING EXCAVATIONS SHALL HAVE THE SIDES AND BOTTOMS TEMPORARILY LINED WITH 6 MIL <br />VISQUEEN IF PLACEMENT OF CONCRETE DOES NOT OCCUR WITHIN 2 HOURS OF THE EXCAVATION OF THE <br />FOOTING. <br />D. SLAB ON GRADE FOUNDATION (CONT.) <br />11. FOUNDATION CONDITIONS NOTED DURING CONSTRUCTION, WHICH DIFFER FROM THOSE DESCRIBED IN <br />THE GEOTECHNICAL REPORT SHALL BE REPORTED TO THE STRUCTURAL ENGINEER AND/OR THE <br />GEOTECHNICAL ENGINEER BEFORE FURTHER CONSTRUCTION IS ATTEMPTED. <br />12. GENERAL CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER 48 HOURS PRIOR TO PLACEMENT <br />OF CONCRETE IN THE FOUNDATIONS. <br />13. IF THERE IS SEEPAGE IN EXCESS OF ONE INCH (I"), THE FOOTING EXCAVATION SHOULD BE PUMPED <br />DRY. <br />14. ALL BACKFILL SHALL BE PLACED AND COMPACTED IN 8" LIFTS OR AS SPECIFIED IN THE <br />GEOTECHNICAL REPORT. <br />15. FILL SHALL BE CLEAN INACTIVE CLAY NOT SILT OR AS SPECIFIED IN THE GEOTECHNICAL REPORT. <br />1(o. STRUCTURAL FILL UNDER FLOOR SLAB SHALL HAVE A PLASTICITY INDEX LESS THAN 20 OR AS <br />SPECIFIED IN THE SOILS REPORT. FILL SHALL BE COMPACTED IN ACCORDANCE WITH <br />RECOMMENDATIONS CONTAINED IN THE SOILS REPORT. <br />11. ALL GRADE ADJUSTMENTS FOR SLAB -ON -GRADE CONSTRUCTION SHALL BE ACCOMPLISHED WITH <br />SELECT FILL AS SPECIFIED IN THE GEOTECHNICAL REPORT. <br />I8. SLAB -ON -GRADE CONCRETE SHALL BE POURED AGAINST A PREPARED SUBGRADE CONTAINING <br />FREE WATER, ICE, FROST, MUD OR OTHER UNSUITABLE MATERIALS. <br />19. TRENCHES FOR BURIED PLUMBING SHALL NOT RUN ALONG. PLUMBING PENETRATIONS MAY CROSS AT <br />RIGHT ANGLES. TRENCH BACKFILLS SHALL BE THOROUGHLY COMPACTED. <br />20. FORMWORK ERECTION SHALL BE ERECTED IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE <br />GUIDE TO FORMWORK FOR CONCRETE, ACI 341 <br />21. HOT WEATHER CONCRETING PROVISIONS FOR CONSTRUCTION PRACTICES WHEN AMBIENT AIR <br />TEMPERATURE IS ABOVE 90 DEGREES FAHRENHEIT SHALL FOLLOW RECOMMENDATIONS PER <br />AMERICAN CONCRETE INSTITUTE STANDARD SPECIFICATION FOR HOT WEATHER CONCRETING, <br />ACI-305R. <br />A. PROPER ATTENTION SHALL BE GIVEN TO INGREDIENTS, PRODUCTION METHODS, HANDLING, <br />PLACING, PROTECTION, AND CURING TO PREVENT EXCESSIVE CONCRETE TEMPERATURES OR <br />WATER EVAPORATION THAT COULD IMPAIR REQUIRED STRENGTH OR 5ERVICEA51UTY OF THE <br />STRUCTURE. <br />B. FRESH CONCRETE TEMPERATURE SHALL BE MAINTAINED BELOW 95 DEGREES FAHRENHEIT FOR 24 <br />HOURS AFTER PLACEMENT. <br />C. MAXIMUM AMBIENT TEMPERATURE FOR CONCRETE PLACEMENT WITHOUT HOT WEATHER <br />CONCRETING PROVISIONS IS 'Be DEGREES FAHRENHEIT AND COOLING. <br />22. COLD WEATHER CONCRETING PROVISIONS FOR CONSTRUCTION PRACTICES WHEN AMBIENT <br />TEMPERATURE IS BELOW 40 DEGREES FAHRENHEIT SHALL FOLLOW RECOMMENDATIONS PER <br />AMERICAN CONCRETE INSTITUTE STANDARD SPECIFICATION FOR COLD WEATHER CONCRETING, <br />ACI-30foR. <br />A. ADEQUATE EQUIPMENT SHALL BE PROVIDED FOR HEATING CONCRETE MATERIALS AND <br />PROTECTING CONCRETE DURING FREEZING OR NEAR FREEZING WEATHER. <br />B. ALL CONCRETE MATERIALS AND ALL REINFORCEMENT FORMS, FILLERS, AND GROUND WITH WHICH <br />CONCRETE IS TO COME IN CONTACT SHALL BE FREE FROM FROST. FROZEN MATERIALS OR <br />MATERIALS CONTAINING ICE SHALL NOT BE USED. <br />C. CONCRETE SHALL BE MAINTAINED ABOVE 50 DEGREES FAHRENHEIT AND IN A MOIST CONDITION <br />FOR AT LEAST THE FIRST 1 DAYS AFTER PLACEMENT EXCEPT WHEN A CURING ACCELERANT OR <br />METHOD IS USED. <br />D. MINIMUM AMBIENT TEMPERATURE FOR CONCRETE PLACEMENT WITHOUT COLD WEATHER <br />CONCRETING PROVISIONS IS 40 DEGREES FAHRENHEIT AND RISING. <br />E. CONCRETE <br />I. ALL CONCRETE MIX SHALL BE DESIGNED BY A QUALIFIED REGISTERED ENGINEER I LAB CONCRETE <br />MIX DESIGN DATA RESULTS SHALL BE SUBMITTED TO STRUCTURAL ENGINEER FOR REVIEW AND <br />APPROVAL <br />2. CONCRETE MIX DESIGNS SHALL BE DESIGNED FOR THE APPROPRIATE EXPOSURE CATEGORY CLASS <br />PER LATEST EDITION OF AMERICAN CONCRETE INSTITUTE ACI-318. <br />3. CONCRETE FOR SLAB -ON -GRADE, GRADE BEAMS, WALLS, ELEVATED AND FOOTINGS SHALL HAVE <br />NATURAL SAND, FINE AGGREGATE, AND NORMAL WEIGHT COARSE AGGREGATES CONFORMING TO <br />ASTM C33, TYPE I PORTLAND CEMENT CONFORMING TO ASTM Cl50, AND SHALL HAVE A MINIMUM <br />COMPRESSIVE STRENGTH WC) AT 28 DAYS AS FOLLOWS <br />LOCATION: WC) MAX. AGGREGATE SIZE <br />SLAB ON GRADE 3000 PSI 1 12 <br />SHALLOW SPREAD FOOTINGS 3000 PSI 1 1/2" <br />SHALLOW MAT FOUNDATION 3000 PSI 1 1/2" <br />RETAINING WALLS AND WALLS 4000 PSI 1 112" <br />COLUMNS 5000 PSI 1 112" <br />ELEVATED DECK 5000 PSI 1 1/2" <br />SLAB ON METAL DECK 5066 PSI I" <br />4. MAXIMUM SLUMP IN CONCRETE SHALL NOT EXCEED 5" IN FLATWORK AND 6" WHEN PLACED BY PUMP. <br />5. WATER USED IN CONCRETE MIX SHALL BE CLEAN, FRESH, AND POTABLE. <br />6. MAXIMUM WATER TO CEMENTITIOUS MATERIAL RATIO (W1CM) SHALL NOT EXCEED 0.50 <br />1. MAXIMUM COARSE AGGREGATE SIZE FOR LIGHTWEIGHT CONCRETE MIXES SHALL BE 3/8 INCHES. <br />8. FLY ASH MAY BE USED AS A POZZOLAN TO REPLACE A PORTION OF THE PORTLAND CEMENT IN A <br />CONCRETE MIX, SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER. FLY ASH, WHEN USED, <br />SHALL CONFORM TO ASTM C618. CONCRETE MIXES USING FLY ASH SHALL BE PROPORTIONED TO <br />ACCOUNT FOR THE PROPERTIES OF THE SPECIFIC FLY ASH USED AND TO ACCOUNT FOR THE SPECIFIC <br />PROPERTIES OF THE FLY ASH CONCRETE THUS RESULTING. THE RATIO OF THE AMOUNT OF THE FLY <br />ASH TO THE TOTAL AMOUNT OF FLY ASH AND CEMENT IN THE MIX SHALL NOT EXCEED 20 PERCENT. <br />9. CONCRETE SHALL BE PROPORTIONED TO MEET THE REQUIREMENTS OF ACI 318. CONCRETE SHALL BE <br />DESIGNED FOR EXPOSURE CLASS F0, S0, P0, AND CO UNLESS NOTED OTHERWISE. <br />10. SUPER -PLASTICIZERS MAY BE ADDED TO THE CONCRETE MIX TO REDUCE WATER CONTENT WHEN <br />PLACING CONCRETE BY PUMPING. PLASTICIZERS AND OTHER CHEMICAL ADMIXTURES SHALL <br />CONFORM TO ASTM C4S4. <br />11. CONCRETE MIX DESIGN SHALL HAVE A RECORD OF 30 COMPRESSIVE STRENGTH TESTS. RECORDS <br />WITH LESS THAN 30 COMPRESSIVE STRENGTH TESTS ARE ACCEPTABLE ONLY IF A MINIMUM 10 <br />CONSECUTIVE TESTS HAVE BEEN PERFORMED WHICH ENCOMPASS A PERIOD OF TIME MORE THAN 45 <br />DAYS. RECORDS SHALL PROVIDE EVIDENCE THROUGH STANDARD DEVIATION CALCULATION THAT THE <br />CONCRETE MIX DESIGN MEETS AND EXCEEDS THE MINIMUM COMPRESSIVE STRENGTH SPECIFIED. <br />12. CONCRETE FINISHES SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS FOR DESIRED SURFACE <br />FINISH. <br />13, CONCRETE PLACED IN INTERIOR AREAS NOT SUBJECT TO EXPOSURE TO EARTH OR WEATHER SHALL <br />HAVE A SMOOTH TROWEL FINISH UNLESS NOTED OTHERWISE BY ARCHITECT. <br />14. CONCRETE PLACED IN EXTERIOR AREAS SUBJECT TO EXPOSURE TO EARTH OR WEATHER OR <br />VEHICULAR TRAFFIC SHALL HAVE A ROUGH BROOM FINISH UNLESS NOTED OTHERWISE BY ARCHITECT. <br />15. CURING COMPOUND MAY BE USED IN LIEU OF WET CURING. SUBMIT CURING COMPOUND TO ARCHITECT <br />AND ENGINEER FOR REVIEW. CURING COMPOUNDS THAT MAY HAVE CONFLICT WITH THE FINISH SHALL <br />NOT BE USED. <br />1(o. CONCRETE CURING SHALL BE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE, ACI-308. <br />11. SLABS AND ELEVATED DECKS SHALL BE GENERALLY FLAT AND LEVEL AREAS THAT REQUIRE <br />DROPS AND SLOPES SHALL AS SPECIFIED ON ARCHITECT/ENGINEER DRAWINGS. <br />18. ARCHITECTURALLY EXPOSED CONCRETE FINISHES AND STAINS SHALL BE AS DIRECTED BY <br />ARCHITECTURAL SPECIFICATIONS. <br />WOOD <br />I.) ALL JOISTS AND RAFTERS SHALL BE #3 SYP UNLESS OTHERWISE NOTED. MULTIPLE 2 X 12 BEAMS SHALL BE OF #2 <br />SYP. ALL WALL STUDS TO BE STUD GRADE OR # 3 SYP. ATTACH ALL RAFTER ENDS TO EXTERIOR WALL FRAMING <br />WITH SIMPSON HI CONNECTORS. USE 5IMF50N HCP FOR HIP � VALLEY CONNECTORS. IN LIEU OF 3 - SD NAILS AS <br />NOTED IN THE I.R.C., ATTACH CEILING AND FLOOR JOISTS TO TOP PLATES W/ 3 - 12D COMMON NAILS (TOENAILED) <br />AT EACH END WHERE A CONNECTOR TIE IS NOT USED. <br />2.) BOLT HOLES THROUGH WOOD SHALL BE DRILLED 1116" MAXIMUM LARGER THAN THE DIAMETER OF THE BOLTS TO <br />BE INSTALLED. BOLTS THROUGH WOOD SHALL BE FITTED WITH STANDARD WASHERS. <br />3.) WOOD FRAMING MEMBERS AND CONNECTIONS SHALL BE CONSTRUCTED AND NAILED IN ACCORDANCE WITH THE <br />I.R.C. BUILDING CODE, LATEST EDITION, UNLESS OTHERWISE NOTED, DETAILED OR SPECIFIED. <br />4.) WALL STUDS TO BE 2 X 4 OR 2 X 6 STUDS 0 1(o" O.C. ATTACH EACH STUD TO TOP AND SOLE PLATES WITH 2-16D <br />NAILS EACH END. AT EXTERIOR WALLS WITHOUT PLYWOOD SHEATHING ATTACH STUDS TO THE BOTTOM SOLE <br />PLATE WITH AN ADDITIONAL 5IMF50N H3 HURRICANE ANCHOR AT 32" O.G. SEE PLAN NOTES FOR ADDITIONAL <br />CONNECTIONS. <br />5.) JOISTS UNDER NON -LOAD BEARING PARTITIONS SHALL BE DOUBLED. <br />(o.) PROVIDE 5IMF50N GALVANIZED "LU I LUS" STANDARD JOIST HANGERS AT SOLID SAWN FLUSH JOINT <br />CONNECTIONS, AND FOR TRUSSES AT FLUSH BEAM CONNECTIONS, OR USE SIMPSON LBV HANGERS. ALL FLUSH <br />BEAM - TO - BEAM CONNECTIONS ARE TO BE MADE WITH SIMP50N "HGLT � GLT" CONNECTORS, U. N. O. ALL <br />SIMPSON SPECIFICATIONS AND RECOMMENDATIONS ARE TO BE FOLLOWED, UNLESS NOTED OTHERWISE. <br />1.) LET -IN DIAGONAL WOOD FRAME BRACING SHALL BE CONTINUOUS #2 KD I X (o, WELL ANCHORED TO HEAD AND <br />SILL PLATES AND ATTACHED TO EACH WALL STUD ALONG DIAGONAL <br />8.) PLYWOOD OR SHEATHING SHALL BEAR AN AFPA TRADEMARK AND BE STAMPED PERFORMANCE RATED FOR <br />APPLICATION AND EXPOSURE ON PANEL. FACE GRAIN IS TO RUN PERPENDICULAR TO SUPPORT MEMBERS FOR <br />HORIZONTAL (FLOOR AND ROOF) SHEATHING. <br />S.) PROVIDE THE SAME NUMBER OF WALL STUDS UNDER BEAMS AS THE NUMBER OF MEMBER'S IN THE BEAMS <br />UNLESS NOTED OTHERWISE (3 - 2 X 4 STUDS UNDER EACH END OF A BEAM MADE OF 3 - 2 X 10 MEMBERS). STUDS <br />TO BE GLUED AND NAILED TO FUNCTION AS A SINGLE COLUMN. <br />10.) WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE TREATED LUMBER. <br />11.) WOOD COLUMNS AND POSTS SHALL BE FRAMED TO TRUE END BEARINGS, AND SHALL BE POSITIVELY ANCHORED <br />TO FOUNDATION WITH APPROVED POST BASES. SUPPORT COLUMN AND POST SECURELY IN POSITION AND <br />PROTECT BASE FROM. DETERIORATION. COLUMNS AND POSTS OF TREATED WOOD MAY BE PLACED DIRECTLY ON <br />CONCRETE OR MASONRY. USE TREATED WOOD FOR ALL FLOOR JOISTS WHICH ARE EXPOSED OR WITHIN IS" OF <br />THE GROUND, OR IN PERMANENT CONTACT WITH EARTH. <br />12.) JOISTS SHALL BE LATERALLY SUPPORTED AT THE ENDS, AT EACH SUPPORT AND AT 8'-0" O.C. MAXIMUM BY <br />SOLID BLOCKING. WHERE THE ENDS OF JOISTS ARE NAILED TO A FLUSH HEADER, BAND OR RIM JOISTS OR TO AN <br />ADJOINING STUD, END BLOCKING MAY BE OMMITTED, U.N.O. AT SHEARWALLS. SOLID BLOCKING SHALL BE NOT <br />LESS THAN TWO INCHES (2") IN THICKNESS AND SHALL MATCH THE DEPTH OF THE JOIST. <br />13.) AT EXTERIOR SOLE PLATES PROVIDE 5/5" DIA. X 10" LONG ANCHOR BOLTS, WITH 2 X 2 SQUARE WASHERS, AT <br />4'-0" (MAX.) O.G., WITH BOLTS AT 12" MAXIMUM FROM WALL ENDS. BOLTS SHALL BE EMBEDED 1" MINIMUM INTO <br />CONCRETE. AS AN ALTERNATE 5IMP50N "MAS" HOLD - DOWNS MAY BE USED. PLACE (0' FROM WALL ENDS AND <br />SPACE AT 2'-8" O.G. SEE PLANS FOR ANY ADDTIONAL SPACING AND HOLD-DOWN AND ANCHORING <br />REQUIREMENTS. <br />14.) ALL BEAMS MADE UP OF MULTIPLE 2 X JOISTS SHALL BE CONNECTED AS PER THE I.R.C. CODE REQUIREMENTS, <br />OR LOCAL CODE, WHICHEVER IS STRICTER. <br />15.) FLITCH BEAM BOLTS SHALL BE 3/4" DIAMETER, U.N.O., LOCATED 2" FROM STEEL PLATE EDGES AND SHALL BE <br />STAGGERED. PROVIDE TWO (2) STANDARD WASHERS PER BOLT, ONE (1) WASHER INSTALLED ON EACH SIDE OF <br />BEAM. <br />1(o.) FLOOR DECKING TO BE MIN. 3/4" TIG PLYWOOD NAILED TO FLOOR FRAMING WITH IOD NAILS SPACED AT 4" O.C. <br />AT PLYWOOD SHEET EDGES AND 10" O.C. AT INTERIOR SUPPORTS. (8 GAUGE SCREWS 1 1/4" MIN. PENETRATION <br />INTO SUPPORT MEMBER MAY BE USED IN LIEU OF IeD NAILS FOR DECKING ATTACHMENT, SAME SPACING AS <br />NAILS.) <br />11.) IF NOT SPECIFIED BY APPLICABLE BUILDING CODES, WOOD MEMBERS, CONNECTIONS AND CONSTRUCTION SHALL <br />COMPLY WITH AITC TIMPER CONSTRUCTION MANUAL REQUIREMENTS, LATEST EDITION. <br />18.) ALL SIMPSON CONNECTORS USED WITH TREATED WOOD MEMBERS TREATED WITH CHROMATED COPPER <br />ARSENATE (CCA-C) OR DOT SODIUM BORATE (SBX) SHOULD BE COATED WITH STANDARD G90 GALVANIZING <br />AND CONNECTED WITH NAILS, SCREWS, OR BOLTS THAT ARE POST HOT DIP GALVANIZED. ALL SIMPSON <br />CONNECTORS USED WITH WOOD MEMBERS TREATED WITH ALKALINE COPPER QUAT (ACQ-C) AND ACQ-D) OR <br />COPPER AZOLE (CBA-A AND CA-B) OR ANY OTHER "NON -DOT" BORATE SHOULD BE COATED WITH SIMPSON Z <br />MAX (GI85) OR POST HOT DIP GALVANIZED (HDG) AND CONNECTED WITH NAILS, SCREWS, OR BOLTS THAT ARE <br />POST HOT DIP GALVANIZED (HDG) OR ARE STAINLESS STEEL (55T300). WOOD TREATED WITH AMONIACAL <br />COPPER ZINC ARSENATE (ACZA) OR ANY OTHER PRESERVATIVE TREATMENT NOT NOTED ABOVE IS NOT <br />ALLOWED FOR CONSTRUCTION. <br />IS.) FOR ENGINEERED WOOD PRODUCTS NOTED ON PLANS, ALL MANUFACTURER SPECIFICATIONS AND INSTALLATION <br />REQUIREMENTS MUST BE FOLLOWED U.N.O. <br />20.) TEMPORARY BRACING IS STRICTLY THE RESPONSIBILITY OF THE CONTRACTOR. THE STRUCTURAL ELEMENTS OF <br />THIS PROJECT WERE DESIGNED BY THE ENGINEER OF RECORD TO RESIST THE CODE SPECIFIED LOADS THAT <br />COULD OCCUR IN THE FINAL COMPLETED STRUCTURE ONLY, POSSIBLY RELYING UPON OTHER ARCHITECTURAL <br />AND STRUCTURAL ELEMENTS FOR BRACING. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE THE DESIGN AND <br />CONSTRUCTION OF ALL TEMPORARY CONSTRUCTION BRACING NEEDED TO MAINTAIN THE SAFETY AND INTEGRITY <br />OF ALL STRUCTURAL ELEMENTS DURING CONSTRUCTION UNTIL ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS <br />ARE ERECTED, FASTENED AND OTHERWISE COMPLETED AS DETAILED ON THE DESIGN DRAWINGS. <br />N. WOOD TRUSSES <br />I. PLATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE TRUSS PLATE INSTITUTE <br />ANSI/TPI I CURRENT EDITION. <br />2. GENERAL CONTRATOR SHALL PROVIDE TEMPORARY BRACING FOR TRUSS INSTALLATION IN <br />ACCORDANCE WITH BUILDING COMPONENT SAFETY INFORMATION GUIDELINES: SCSI-15, 5CSI-82, 5C5I- <br />53, BCSI-Bl, AND 5C5I-510 GUIDES FOR HANDLING, INSTALLING, RESTRAINING AND BRACING OF <br />TRUSSES. <br />3. GENERAL CONTRACTOR SHALL ENSURE THAT THE BUILDING SUPPORT CONDITIONS ARE OF SUFFICIENT <br />STRENGTH AND 5TA51ITY TO ACCOMODATE THE LOADS APPLIED DURING THE TRUSS INSTALLATION <br />PROCESS. <br />4. TRUSSES SHALL BE PLACED PER THE APPROVED TRUSS LAYOUT. TRUSSES SHALL NOT BE INSTALLED <br />UPSIDE DOWN. <br />5. TOLERANCE FOR OUT OF PLUMB ERECTION IS D/50 WHERE D IS THE DEPTH OF THE TRUSS. <br />TOLERANCE FOR OUT OF PLANE BOWING IS L1200 WHERE L IS THE CLEAR SPAN OF THE TRUSS. <br />6. DO NOT CUT TRUSS MEMBERS. REPORT ANY DAMAGE TO TRUSS MANUFACTURER FOR REPAIR <br />DIRECTIONS. <br />1. MATERIAL STAGING SHALL NOT PLACED ON UNRESTRAINED TRUSSES. STAGED MATERIAL SHALL BE <br />PLACED FLAT AND PERPENDICULAR TO FLOOR TRUSSES TO SPAN ACROSS A MINIMUM OF 3 TRUSSES. <br />SHEATHING MATERIAL SHALL NOT BE PLACED ON EDGE. MAXIMUM STAGED MATERIAL STACK <br />HEIGHTS: <br />A. GYPSUM BOARD SHALL NOT EXCEED 12" <br />B. PLYWOOD OR OSB SHALL NOT EXCEED 16" <br />C. ASPHALT SHINGLES SHALL NOT EXCEED 2 BUNDLES <br />D. CONCRETE BLOCK SHALL NOT EXCEED 8" <br />E. CLAY TILE SHALL NOT EXCEED 4 TILES. <br />8. PLATED WOOD TRUSS PROFILES SHALL BEAR THE SEAL OF A LICENCED PROFESSIONAL ENGINEER IN <br />THE STATE OF WHICH THE PROJECT IS LOCATED. <br />S. FLOOR TRUSSES SHALL BE DESIGNED FOR SUPERIMPOSED LOADS TCDL 15 PSF, BCDL 5P5F, BCLL 0 <br />PSF, AND TCLL PER OCCUPANCY UNLESS NOTED OTHERWISE. <br />10. ROOF TRUSSES SHALL BE DESIGNED FOR SUPERIMPOSED LOADS OF TCDL 15 PSF, BCDL 5 PSF, BCLL <br />0 PSF, AND TCLL OF 20 PSF FOR CONSTRUCTION UNLESS NOTED OTHERWISE. <br />11. TRUSS DEFLECTION SHALL NOT EXCEED I INCH. <br />M. COMPONENTS AND CLADDING PRESSURES. <br />ROOF NET UPLIFT <br />ZONE <br />0-10 $0. FT. <br />20 50. FT. <br />50 50. FT. <br />>I00 60. FT. <br />>500 $0. FT. <br />1 <br />-41 <br />-40 <br />-39 <br />-38 <br />-36 <br />2 <br />-69 <br />-62 <br />-52 <br />-45 <br />-45 <br />3 <br />-104 <br />-86 <br />-63 <br />-45 <br />-45 <br />WALL PRESSURE <br />ZONE <br />0-10 SQ. FT. <br />20 50. FT. <br />50 50. FT. <br />>I00 50. FT. <br />>500 $0. FT. <br />4 <br />38,-41 <br />36,-n <br />34,-31 <br />32,-35 <br />28,-32 <br />5 <br />38,-50 <br />36,-41 <br />34,-43 <br />32,-38 <br />2S,-32 <br />PARAPET PRESSURE <br />ZONE <br />0-10 50. FT. <br />20 SQ. FT. <br />50 50. FT. <br />>I00 60. FT. <br />>500 $0. FT. <br />4 <br />32,-36 <br />30,-34 <br />38,-31 <br />21,-30 <br />23,-26 <br />5 <br />32,-45 <br />31,-42 <br />28,-28 <br />21, -34 <br />23, -26 <br />I. NOTES: (0-10 SQ FT EXAMPLE DENOTES EFFECTIVE WIND AREA <br />2. + AND - SIGNS SIGNIFY PRESSURES ACTING TOWARD OR AWAY FROM SURFACES RESPECTIVELY. <br />ALL VALUES SHOWN ARE IN PSF. <br />3. WIND PRESSURE FOR FFFECTIVE WIND AREAS BETWEEN THE SPECIFIED RANGES MAY BE <br />DETERMINED BY INTERPOLATION, OTHERWISE, USE THE VALUE ASSOCIATED WITH THE LOWER <br />EFFECTIVE AREA. <br />4. A = WIDTH OF EDGE STRIP EQUAL TO 10% OF THE LEAST HORIZONTAL DIMENSION (L OR B) OF 40% <br />OF THE ROOF HEIGHT (H). WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST <br />HORIZONTAL DIMENSION OR 3FT. <br />5. JOIST GIRDERS WITH TRIBUTARY AREAS GREATER THAN 100 SQ. FEET MAY BE DESIGNED USING <br />MWFRS PROVISIONS. DESIGN FOR GROSS UPLIFT PRESSURE 42 PSF (I.OW) <br />6. VALUES SHOWN ARE BASED ON IBC 20121 ASCE 1-10 WIND CALCULATIONS FOR COMPONENTS AND <br />CLADDING AND ARE ULTIMATE VALUES (LRFD). VALUES SHOWN ARE FOR USE IN ASCE 1-10 LOAD <br />COMBINATIONS SHOWN IN SECTION 2.32 (1.0W) <br />1. THE BUILD LAYOUT SHOWN IS INTENDED TO BE SCHEMATIC, APPLY WIND PRESSURED PROVIDE <br />SIMILARLY TO BUILDINGS) AT THIS PROJECT. <br />8. UNLESS OTHERWISE SPECIFIED, ROOF DEAD LOAD TO BE USED FOR NET UPLIFT CALCULATIONS <br />SHALL NOT EXCEED 8 PSF. NET UPLIFT PRESSURE SHALL NOT BE LESS THAN 16 PSF. <br />NO. 6=56 i <br />:•p• ; �: <br />Af <br />0% STATE OF <br />l <<` •;OR10P��,� �D <br />,,,�� �01VAL 110fc� i�L <br />H <br />U <br />Z <br />O w <br />W 0- <br />5; OC <br />w p <br />ir w <br />CO Lu <br />0 :D <br />W W <br />w N <br />o <br />Q N <br />rn <br />am <br />J <br />LL <br />VJ <br />I <br />_j <br />1 <br />TW <br />I..t� <br />Lu <br />N <br />[RE F#: 21-1458-0015 <br />DRN:EV CHK: OC ES: KB <br />GENERAL <br />NOTES <br />SHEET NO. <br />so.1 <br />