Laserfiche WebLink
L I r e --�' -- _ _ Lnu �nLujlr III'�i! t'ILI'��I glut �� 0111'1'°ILJI IJ! _ <br />I <br />CENTRAL <br />STATION <br />(WALMART <br />1- 800- 530- 9924#1) <br />120V A.C. <br />ELECTRONIC FIRE <br />PROTECTION RISER DIAGRAM. <br />NOT TO SCALE <br />TO CONTINUE N) PS-2 <br />REF. EFP1.---------------------- HS LP-1 <br />D- 2 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />1 <br />I <br />1 <br />1 <br />STOCKROOM <br />FACU <br />EXISTING BOSCH <br />D9412GV4 <br />E E TO EXISTING <br />.._.._.._.._.._.._.._.._..-.._.._.._.._..------ _.._.._.._..-..-.._.._.._.._.._.._.._.._.._.. PT ...... <br />BURGLAR AND <br />FIRE ALARM <br />INITIATING DEVICES <br />I (E) 101 <br />I <br />CUSTOMER <br />SERVICE <br />I <br />I <br />12VDC_.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.. 2 (E) <br />ABOVE <br />D192G (E) SDIX BUS FACU <br />I � <br />COURTESY DESK VESTIBULE-GR <br />I � <br />:DATA.._.._.. FAC (E).._.._.. FAA (E) <br />TO EXISTING':12_.._.._.VDC <br />NOTIFICATION POWER D1256 D1257 <br />SUPPLIES #1-#2 <br />i <br />i <br />i <br />EXISTING CIRCUIT k1_ 2 E) LP1 <br />NPS (E) 75cd 75cd 115cd 115cd 15cd 15cd 15cd <br />120V A.C. EXISTING CIRCUIT #2--------------------------JH]SWPHS_ AL802ULADA E) E O <br />POWER---------------------------------- <br />---------------------- ---------------- <br />-------- <br />-------- <br />------------- <br />SUPPLY <br />1 15cd 75cd 75cd) 15cd 75cd) <br />NEW CIRCUIT3 _____________________ N) N) <br />---------------------------------- LP3: <br />:SCOPE OF WORK <br />75cd 75cd <br />NPS#3 NEW CIRCUIT #4 ` <br />HS N) V N) LP4 <br />--------------------------------------------------------------------�`' O <br />L----------------------------------------------------------------------------------------------------! <br />UPC <br />Ir'------------- <br />I I <br />I 1 <br />I I <br />I j <br />I I <br />I I <br />I j <br />I I <br />EDC #1 <br />NPS 1 (E) <br />NPS 2 <br />I BREAKROOM <br />115cd 1 <br />PS-3 HS (N) -- ----��-- -------------- <br />INSTALL NEW 115CD HORN/STROBE -i <br />LP-3 ------------------------- <br />D- 1 I I INSTALL ONE NEW 75CD CEILING MOUNT <br />I I I <br />I AND RUN WIRE AS SHOWN. I I I HORN/STROBE AND ONE NEW 75CD CEILING <br />I 1 ® I MOUNT STROBE. RUN NEW WIRE AS SHOWN. <br />- <br />I I I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />OHS <br />----wit-------------- <br />PS-2 <br />LP- 1 <br />I <br />D- 1 <br />I <br />I <br />RELOCATE EXISTING NOTIFICATION <br />DEVICE AS NEEDED AND RUN WIRE <br />AS SHOWN. <br />I <br />Lh <br />TO CONTINUE <br />REF. EFP1. <br />TO CONTINUE, <br />REF. EFP1. <br />E <br />d <br />0 <br />> I <br />m � <br />m <br />I <br />m I <br />V) <br />n <br />O a <br />4 N <br />_ I <br />N � <br />00 <br />N r- <br />.�o <br />0C)� <br />N a <br />N <br />0 <br />0 <br />c <br />3 <br />W o <br />> c- <br />Q M <br />I <br />o <br />U) o- <br />Q I <br />o 00 <br />c �0- <br />�o <br />m N <br />O <br />m NI <br />Q <br />L <br />_co <br />N � <br />O <br />00 N <br />� O' <br />N <br />O' <br />o <br />CO <br />LIJQ0 <br />z/ <br />( . <br />m � <br />ENLARGED ELECTRONIC <br />FIRE PROTECTION PLAN <br />0' 816' 24' 32' <br />, r I/ /I r 7 7 7 7 71 <br />SCALE: 1 /8"=l'-O" <br />ENLARGED ELECTRONIC <br />FIRE PROTECTION DEMO PLAN <br />1 /8"=1'-0" <br />� i • <br />SPARK I� I MANAGER <br />ROOM OFFICE <br />MEN <br />FAMIL <br />TOILET <br />MOTHER'S <br />i ROOM <br />15cd <br />---- <br />- - - - - - - - - - ---------------- N) V PS-3I LP-3 <br />D- 4 <br />INSTALL ONE NEW 15CD <br />CEILING MOUNT STROBE AND <br />--, RUN NEW WIRE AS SHOWN. <br />ALARM CALCULATION NOTE <br />A SITE SURVEY OF THE EXISTING FIRE ALARM SYSTEM WAS NOT CONDUCTED BY THE ENGINEER OF RECORD OR HIS <br />REPRESENTATIVE. EXISTING DEVICES, INCLUDING MAKES/MODELS, VOLTAGE DROPS, AND CURRENT REQUIREMENTS, HAVE <br />NOT BEEN VERIFIED. CALCULATIONS SHOWN ARE BASED UPON A PROTOTYPICAL DESIGN AND ARE TO BE CONSIDERED <br />FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE FOR INSTALLATION PER ALL REQUIREMENTS OF NFPA 72, AND <br />SHALL VERIFY THAT THE EXISTING POWER SUPPLY IS ADEQUATE. IF AN ADDITIONAL POWER SUPPLY IS REQUIRED, THE <br />CONTRACTOR SHALL COORDINATE WITH THE ON -SITE WALMART ALARM PROJECT MANAGER PRIOR TO PROCEEDING WITH <br />THE PURCHASE OR INSTALLATION OF THE ADDITIONAL EQUIPMENT. <br />WIRE LEGEND <br />A - --••-••-••-••-••-••- - -••-• - - - - - FIRE ALARM SYSTEM 3pr #18 AWG FPL TWISTED <br />B----------------------------- NOTIFICATION CIRCUIT 1pr #12 AWG FPL ZIP <br />_______--_.....--_--_- EXISTING NOTIFICATION CIRCUIT 1pr #12 AWG <br />C ___________ FPL ZIP <br />D MULTIPLE CABLES <br />PLENUM RATED CABLE FPLP SHALL BE UTILIZED IN PLENUM RATED CEILING AREAS ONLY <br />WP = WEATHERPROOF CABLE SHALL BE PROVIDED AS REQUIRED <br />(+) POSITIVE CIRCUIT POLARITY (-) NEGATIVE CIRCUIT POLARITY <br />OCTAGON T-BAR <br />T-BAR CONDUIT BACK <br />CLIP BOX DROP TILE <br />CEILING GRID <br />O O O <br />DROP CEILING NOTIFICATION <br />TILE DEVICE <br />NOTIFlCATION <br />ACOUSTICAL CEIUNG MOUNTING DETAIL <br />SCALE: NTS <br />4" X 4" <br />SQUARE <br />CONDUIT 7rol <br />DEVICE <br />MOUNTING CEILING <br />HEIGHT 0 0 <br />7- <br />10' MAX A.F.F. <br />FINISH FLOOR <br />GYP C IUNG <br />HORN STROBE MOUNTING DETAIL <br />CLAIMS <br />STORAC <br />ROOM <br />75cd <br />I <br />----�N) HS <br />PS-3 <br />ALCOVE D-5 <br />INSTALL ONE NEW 75CD <br />CEILING MOUNT <br />HORN/STROBE AND RUN NEW <br />WIRE AS SHOWN. <br />CEILING HEIGHT <br />4" <br />ALARM SYMBOLS LEGEND <br />SYMBOL LAN <br />QTY <br />DEVICE DESCRIPTION <br />PLAN <br />SYMBOL <br />QTY <br />DEVICE DESCRIPTION <br />FACU <br />1 <br />EXISTING FIRE ALARM CONTROL <br />PANEL BOSCH D9412GV4 <br />D192G <br />1 <br />EXISTING NAC MODULE <br />BOSCH D192G <br />FAC <br />1 <br />EXISTING CONTROL ANNUNCIATOR <br />NPS <br />2 <br />EXISTING NOTIFICATION POWER <br />SUPPLY ALTRONIX <br />BOSCH D1256 <br />AL1002ULADA n=UNIT NUMBER <br />FAA <br />1 <br />EXISTING ANNUNCIATOR <br />NPSn <br />1 <br />EXISTING NOTIFICATION POWER <br />SUPPLY ALTRONIX <br />BOSCH D1257 <br />AL802ULADA n=UNIT NUMBER <br />115cd <br />HS <br />1 <br />NEW CEILING MOUNT HORN/STROBE <br />SYSTEM SENSOR PC2RL, 115cd <br />END OF LINE RESISTOR/DEVICE <br />75cd <br />HS <br />3 <br />NEW CEILING MOUNT HORN/STROBE <br />O <br />1 <br />EXISTING SMOKE DETECTOR <br />BOSCH D273THE <br />SYSTEM SENSOR PC2RL, 75cd <br />75cd <br />O <br />2 <br />NEW CEILING MOUNT STROBE <br />PT <br />EXISTING PORT MODULE <br />SYSTEM SENSOR SCRL,75cd <br />BOSCH D9127U <br />15cd <br />O1 <br />NEW CEILING MOUNT STROBE <br />SYSTEM SENSOR SCRL,15cd <br />EXISTING MANUAL PULL STATION <br />BOSCH FMM-100 <br />HS P <br />E <br />EXISTING WEATHERPROOF <br />WALL MOUNT STROBE <br />El <br />EXISTING WALL MOUNT STROBE <br />EXISTING CEILING MOUNT <br />HS <br />HORN/STROBE <br />DEVICE <br />ARE <br />MOUNTING <br />DUBOX <br />HEIGHT <br />24'-0" <br />23' MAX <br />FINISH FLOOR TRUSS <br />HORN/STROBE <br />STROBE <br />MOUNTING DETAIL <br />SCALE: NTS <br />EXISTING FIRE ALARM SYSTEM <br />INPUT/OUTPUT MATRIX <br />SYSTEM INPUTS <br />1 <br />FIRE ALARM SYSTEM AC POWER FAILURE <br />2 <br />FIRE ALARM SYSTEM LOW BATTERY <br />3 <br />OPEN CIRCUIT <br />4 <br />GROUND FAULT <br />5 <br />NOTIFICATION APPLIANCE CIRCUIT SHORT <br />6 <br />BUILDING MANUAL PULL STATIONS <br />7 <br />AREA SMOKE DETECTORS <br />8 <br />SPRINKLER WATERFLOW IN BUILDING <br />9 <br />HVAC AIR DUCT SMOKE DETECTORS <br />10 <br />HOOD FIRE SUPPRESSION SYSTEM ALARM <br />11 <br />SPRINKLER TAMPER SWITCH <br />12 <br />BACKFLOW VALVE TAMPER <br />13 <br />FAILURE OF SIGNAL TRANSMISSION <br />14 <br />ACTIVATION OF AP GATE PUSH BUTTON <br />15 <br />DRY SYSTEM HIGH/LOW PRESSURE <br />16 <br />CEILING HEIGHT NOTE <br />STOCKROOM 21'-0" TO 23'-0' <br />SALES 17'-4" TO 17"-9" <br />BREAKROOM 9'-0" <br />MOTHERS ROOM 9'-0" <br />OPTICAL SALES 12'-0" <br />PLAN ABBREVIATIONS <br />(E)-EXISTING TO REMAIN <br />(R)-RELOCATE <br />(N)-NEW <br />SYSTEM OUTPUTS <br />FACP ANNUNCIATION NOTIFICATION REQUIRED FIRE SUPPLEMENT <br />SAFETY CONTROL <br />0 <br />A,0 o� 0 �P <br />0 <br />�O <br />P �v <br />0 <br />�S� C2 <br />00� PJ� 00`r PJ� 00� PJ� <br />DODO©00©00©00©00©" <br />0©© <br />M <br />OMMUMMUMMMUMOMMMMMMM <br />omm000mmammommmmmlmoM <br />MMnaMMMMUMaMMOMMMnMM <br />MMnaMMMOnMaMMMMMMMMM <br />�0000©©o©oo©oo©0000®o <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />12 <br />13 <br />14 <br />15 <br />116 <br />STANDBY <br />TOTAL STANDBY <br />ALARM <br />Device Type QTY <br />CURRENT <br />CURRENT ALARMCURRENT <br />CURRENT <br />AL802UL-ADA 1 <br />0.090 <br />0.090 0.175 <br />0.175 <br />f,a .. , ti .. , .. �, . .a• . - . �C^:s ..... .2 js :....., •:. a���_''��a�� \ � .::,,; �. .. �; .,�,,"' <br />3„��� � „s..4_ ._ i;a..� ,aa�?,;: <br />BOSCH D273THE SMOKE DETECTOR W/EOLR 1 <br />0.015 <br />1 0.015 0.036 <br />0.036 <br />CEILING HORN/STROBE PC2R @ 115cd 2 <br />0.218 <br />0.436 <br />CEILING HORN/STROBE PC2R @ 75cd 1 <br />0.176 <br />0.176 <br />CEILING HORN/STROBE PC2R @ 15cd 3 <br />0.079 <br />0.237 <br />WEATHERPROOF WALL HORN/SyTROBrEe @ 75cd 1 <br />0.176 <br />0.176 <br />j, <br />n <br />CEILING HORN/STROBE PC2RL @ 115cd 1 <br />0.187 <br />0.187 <br />CEILING HORN/STROBE PC2RL @ 75cd 2 <br />0.143 <br />0.286 <br />CEILING STROBE SCRL @ 75cd 1 <br />0.111 <br />0.111 <br />CEILING STROBE SCRL @ 15cd 1 <br />0.041 <br />0.041 <br />CEILING HORN/STROBE PC2RL @ 75cd 1 <br />0.143 <br />0.143 <br />CEILING STROBE SCRL @ 75cd 1 <br />0.111 <br />0.111 <br />TOTAL <br />TOTALS <br />STANDBY <br />0.105 <br />TOTAL ALARM <br />2.115 <br />COMPUTATIONS <br />TOTAL AMPS USED IN STANDBY= <br />0.105 X 24 HOURS= <br />2.520 AH <br />TOTAL AMPS USED IN ALARM= <br />2.115 X 5 MIN= <br />0.176 AH <br />+ 20% CONTINGENCY <br />0.539 AH <br />TOTAL STANDBY BATTY REQUIRNIE NTs= <br />3.235 AH <br />TOTAL BACKUP BATTERY PROVIDES <br />7.000 AH <br />TOTAL STANDBY BACKUP BATTERY REQUIRED= <br />3.235 AH <br />Existing (2) 12VDC, 7.0 Ah batteries for 7.0 Ah at 24VDC <br />TOTAL BACKUP BATTERY RESERVED= <br />3.765 AH <br />VOLTAGE <br />NAC <br />SOURCE <br />TOTAL <br />WIRE LENGTH <br />VOLT <br />I AT LAST <br />CIRCUIT <br />VOLTAGE <br />AMP <br />(FEET) <br />DROP <br />%DROPI <br />DEVICE <br />NPS#3-3 <br />20.4 <br />0.6251 <br />630 <br />1.52 <br />7.45 <br />18.88 <br />NPS#3-4 <br />20.4 <br />0.2541 <br />555 <br />0.54 <br />2.671 <br />19.86 <br />WALMART STORE #0706 <br />7631 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33541 <br />=w <br />0m <br />o0) <br />�Cm <br />A N <br />i <br />Q� <br />�o <br />TZo <br />Co <br />°z <br />0 <br />Z <br />U) <br />w <br />0 <br />` v <br />ID <br />N <br />?� <br />U <br />Boa <br />101, <br />E <br />U) <br />2 <br />I= w <br />ro o <br />W V)i_oa o0w <br />(n tr pNwF-'0 u`Z¢ <br />0 W r'-4 Z) OZ cn lr <br />W N w N Z-Z <br />QQOOOOoaWUv�W0 <br />0' a �zw�NQ�Jw0om <br />-�omF- xo,zcna} <br />o LL-Q'UZ''w w- wW2��>< <br />Z 020< �oprawww <br />zo 9 <br />-0RIiNwoWujCo"z <br />4waF¢o <br />3w wraa¢zzo¢ <br />ZWSzzo~UQI cnwM ZN< <br />=N� wwo: <br />d'Z-HWbwww <br />0_ oo-_wowo= <br />{= inwa�oo�jroirumo�~ <br />f5N Q¢JU-.t Q Q <br />O© <br />0 0 <br />O 0 <br />� <br />� <br />o <br />a <br />O <br />v <br />Ld <br />Q� <br />0 <br />CrD <br />m <br />0 <br />~ <br />(n <br />Cv <br />Cv <br />W <br />N <br />z <br />0 <br />ISSUE BLOCK <br />CHECKED BY: <br />REI <br />DRAWN BY: <br />BRY <br />PROTO: <br />192-SPBR <br />POSSESSION DATE: <br />06/21 /21 <br />DOCUMENT DATE: <br />04/27/21 <br />0 <br />� � e <br />r <br />STA _ SUN 2421 <br />0! 1-0 <br />`Off -L' <br />Ricky N. Terrell, P.E. <br />FL License # 63468 <br />ELECTRONIC <br />FIRE <br />PROTECTION <br />RISER AND <br />CALCULATIONS <br />SHEET: <br />FP2 <br />